• Title/Summary/Keyword: 부식평가

Search Result 1,170, Processing Time 0.032 seconds

A Study on the Floating Island for Water Quality Improvement of a Reservoir (저수지 수질개선을 위한 인공식물섬 조성에 관한 연구)

  • Lee, Kwang-Sik;Jang, Jeong-Ryeol;Kim, Young-Kyeong;Park, Byung-Heun
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.1
    • /
    • pp.77-82
    • /
    • 1999
  • Three floating islands have been constructed for water quality improvement for a polluted irrigation reservoir. Each floating island consists of 10 segments. Each segment hay an area of $16m^2$(4×4m) and is made of wood frames and floats(polystyrene foam). We planted three species of aquatic macrophytes(Typha angustifolia, Zizania latifolia, and Phragmites australis) in floating island on June, 1998. They grew very well without death. We would like to evaluate Phragmites australis is the most suitable aquatic macrophyte that could be planted in a floating island because it maintained the best balance of its root and shoot among them. During their grown period, net primary productivity of Typha angustifolia was $962gDM/m^2$, Zizania latifolia was $1,115gDM/m^2$, and Phragmites australis was $523gDM/m^2$. From these data, it would be estimated to 5.0Kg uptake of nitrogen by aquatic macrophytes and phosphorus 0.8Kg in 3 floating islands. The floating islands worked well as a habitat of fish and prawns. Many kinds of insect lived on the floating islands. The floating island has not only the function of water quality treatment but also several advantages: improvement of landscape and species diversity; low cost of maintenance; low technology; unnecessary of energy; less susceptible to variations in pollutant loading. It could be evaluated a good measure of water quality improvement for an irrigation reservoir. However, it should be intensively studied to develop more light, strong, durable and low-priced frames for efficient floating islands.

  • PDF

Improvement of Mid-and Low-flow Estimation Using Variable Nonlinear Catchment Wetness Index (비선형 유역습윤지수를 이용한 평갈수기 유출모의개선)

  • Hyun, Sukhoon;Kang, Boosik;Kim, Jin-Gyeom
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.779-789
    • /
    • 2016
  • The effective rainfall is calculated considering the soil moisture. It utilizes observed data directly in order to incorporate the soil moisture into the rainfall-runoff model, or it calculates indirectly within the model. The rainfall-runoff model, IHACRES, used in this study computes the catchment wetness index (CWI) first varying with temperature and utilize it for estimating precipitation loss. The nonlinear relationship between the CWI and the effective rainfall in the Hapcheondam watershed was derived and utilized for the long-term runoff calculation. The effects of variable and constant CWI during calibration and validation were suggested by flow regime. The results show the variable CWI is generally more effective than the constant CWI. The $R^2$ during high flow period shows relatively higher than the ones during normal or low flow period, but the difference between cases of the variable and constant CWI was insignificant. The results indicates that the high flow is relatively less sensitive to the evaporation and soil moisture associated with temperature. On the other hand, the variable CWI gives more desirable results during normal and low flow periods which means that it is crucial to incorporate evaporation and soil moisture depending on temperature into long-term continuous runoff simulation. The NSE tends to decrease during high flow period with high variability which could be natural because NSE index is largely influenced by outliers of underlying variable. Nevertheless overall NSE shows satisfactory range higher than 0.9. The utilization of variable CWI during normal and low flow period would improve the computation of long-term rainfall-runoff simulation.

A Comparative study of roughness of enamel surface to various interdental enamel stripping methods in vitro (치간 법랑질 삭제방법에 따른 치아표면 거칠기에 관한 비교연구)

  • Row, Joon;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.29 no.4 s.75
    • /
    • pp.483-490
    • /
    • 1999
  • Interdental enamel stripping is an usual method for correction of abnormal tooth shape and tooth size discrepancy which is one of the etiologic factors of malocclusion. Clinically it Is useful to correct the minor crowding in anterior teeth and posterior occlusion during finishing stage of orthodontic treatment. But this procedure has risks such as irreversible tooth reduction and remaining roughness of enamel surface can accumulate plaque which can evoke periodontal problem. Even if various methods were introduced to minimize the enamel surface roughness, their evaluation was limited in morphologic differences by scanning electronic microscope(SEM). The purpose of this study was to compare the various interdental enamel stripping method by SEM and to quantify the difference of surface roughness by use of Surfcorder SEF-30D(Kosaka Lab. Ltd.) which can measure the roughness of surface. The stripping methods were divided into mechanical and mechanical-chemical method. Air-rotor stripping and separating strip were used for mechanical stripping and $37\%$ phosphoric acid was used for chemical stripping. The enamel surface roughness after mechanical or mechanical-chemical stripping of interproximal surfaces of premolars which were extracted for orthodontic purpose were measured and compared by means of SEM and $Surfcorder^{\circledR}$, the results were as follows. 1. Enamel surface of primary treated by coarse diamond bur and separating strip groups showed highest value of roughness. 2. To compare the primary treated groups between mechanical and mechanical-chemical method, the latter group showed lower value of roughness remarkably. 3. Mechanical stripping groups which were treated both coarse and fine instrument showed lower value of roughness as much as non treated group. 4. The use of Pumice for final polishing did not show significantly smoothening the stripped enamel surface any more.

  • PDF

The efficacy of denture cleansing agents: A scanning electron microscopic study (수종 의치세정제의 세척 효과에 관한 주사전자현미경적 비교 연구)

  • Yun, Bo-Hyeok;Yun, Mi-Jung;Hur, Jung-Bo;Jeon, Young-Chan;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.1
    • /
    • pp.57-64
    • /
    • 2011
  • Purpose: The purpose of this study was to compare the cleansing performance of a distilled water, a diluted solution of sodium hypochlorite as a household bleaching cleanser and three alkaline peroxide cleansers in vivo plaque deposits by using scanning electron microscope. Materials and methods: Five individuals were selected from department of the prosthodontics in Pusan National University Hospital, and each of them was inserted with specimens for plaque accumulation in their temporary dentures for 48 hours. The specimens were removed and cleaned by each cleansing agents for 8 hours. Scanning electron micrographs were made from the specimens at a magnification of ${\times}2,000$. A panel of ten persons with a dental or paradental background, but not directly involved in the study, was selected to analyze the photomicrographs to determine which denture cleanser was more effective in removing plaque. Results: Diluted solution of sodium hypochlorite was the most effective at removing plaque following $Polident^{(R)}$, $Cleadent^{(R)}e$, $Bonyplus^{(R)}$ and distilled water in order. But there was no significant difference of cleansing efficacy between diluted solution of sodium hypochlorite and $Polident^{(R)}$, $Polident^{(R)}$ and $Cleadent^{(R)}e$, $Cleadent^{(R)}e$ and $Bonyplus^{(R)}$, respectively (P > .05). Alkaline peroxide cleansers by themselves cannot adequately remove accumulated plaque deposits, especially if the deposits are heavy. Corrosion could be seen on the surface of non-precious alloy specimens immersed in diluted solution of sodium hypochlorite. Conclusion: It is recommended to use of alkaline peroxide type cleansers with brushing whenever possible, since denture cleanliness is often poor due to the relative inefficiency of these cleansers.

A study for detection of melt flow zone about polyethylene butt fusion joints (폴리에틸렌 배관 버트융착부 열용융거리 측정에 대한 연구)

  • Kil, Seonghee;Kim, Younggu;Jo, NYoungdo;Lee, Yeonjae
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.103-109
    • /
    • 2016
  • Polyethylene pipes has useful benefits which are anti-corrosive and flexible material, so it is used to gas pipes but also class 3 water pipes of nuclear power plant, process pipes of petrochemical plant and chemical plant. So the usage of polyethylene pipes is widely increased. But it has been limited for the usage of polyethylene, because it can not be directly detected to fusion joints by using non destructive evaluation. Polyethylene pipes are connected by two methods, one is butt fusion and the other is electrofusion. Butt fusion is widely used to connecting the pipes. It is proposed to method for determining the reliability of joints in this study that is detection of the melt flow zone at fusion joints. In this study, middle density polyethylene is used, outside diameter of the test specimen is 225mm and thickness is 20.5mm. Speed of ultrasonic of this test specimen is 2,200m/s. Test specimens were fabricated by varying the heating time which means from 0% to 130% applying time through heating plate to polyethylene for detecting melt flow zone. Also 4 additional test specimens were made, one was made that not scrapping attached surface of pipes but applying 100% of the proper heating time and the others were made to include of soil, gravel and vinly tape paper at fusion joints, that were also applied 100% of proper heating time. Ultrasonic testing to measure the melt flow zone of 20 test specimens was conducted by using 3.5MHz and 5.0MHz ultrasonic probes and melt flow zone measuring was conducted to three times at different point to one specimen. To differentiate the melt flow zone signal, post image processing was equally conducted to all test results and image levels, contrast, sharpen, threshold were adopted to all teat results and the test results were displayed gray scale. From the results, for the shorter heating times the reflection area of multiple echo have been increased, so the data was obtained from the position where it can be eliminated as much as possible. At 80% of proper heating time(168 sec.), the signal of melt flow zone was obtained clearly, so measuring could be conducted. From 7% of proper heating time(15 sec.) to shorter heating times. we could not obtain the signal because test specimen was not fused. From the result, we can verify that measuring of melt flow zone by using phased array ultrasonic imaging method is possible. And we can verify to complete and incomplete butt fusion by measuring the melt flow zone.

Screening of the Optimum Filter Media in the Constructed Wetland Systems through Phosphorus Adsorption Capacities (인의 흡착능 평가를 통한 인공습지 하수처리 시스템의 여재 선발)

  • Lee, Hong-Jae;Seo, Dong-Cheol;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.22 no.2
    • /
    • pp.148-152
    • /
    • 2003
  • The phosphorus(P) adsorption capacities of various filter media were investigated in relation to the size and types of fitter media to screen the optimum condition. The objective of this study was to evaluate the constructed wetland longevity by improving P adsorption capacity. The maximum P adsorption capacities of filter media A($4{\sim}10\;mm$), B($2{\sim}4\;mm$) and C($0.1{\sim}2\;mm$) were 8, 10 and 22 mg/kg, respectively, showing those increased as the filter media size decreased. Among the experimental media, the optimum filter media size was $0.1{\sim}2\;mm$. When the filter Medium was supplemented with organic materials which were piled up and decayed in the constructed wetland, the P adsorption capacity was significantly enhanced Under the conditions of optimum fitter media size, the respective Maximum P adsorption capacities of filter media C when supplemented with Ca, Mg, Al and Fe were higher than that of filter media C. However the addition of Ca, Mg, Al and Fe to constructed wetland were not recommended because of the possibility of their secondary pollution. The maximum P adsorption capacity of filter media C was 22 mg/kg, but this was increased to 36 mg/kg when filter media C was supplemented with 2% oyster shell.

Optimal Application Rate of Mixed Expeller Cake and Rice Straw and Impacts on Physical Properties of Soil in Organic Cultivation of Tomato (토마토 유기재배에서 혼합유박과 볏짚의 적정시용량 및 토양 물리성에 미치는 영향)

  • Lim, Tae-Jun;Park, Jin-Myeon;Lee, Seong-Eun;Jung, Hyun-Cheol;Jeon, Sang-Ho;Hong, Soon-Dal
    • Korean Journal of Environmental Agriculture
    • /
    • v.30 no.2
    • /
    • pp.105-110
    • /
    • 2011
  • BACKGROUND: In this study, 5 different treatments such as non-treatment, mixed expeller cake 1.0 N (standard nitrogen fertilizer), rice straw, rice straw+mixed expeller cake 0.5 N, rice straw+mixed expeller cake 1.0 N were performed over 4 cropping seasons over 2 years in order to identify the optimal application rate of mixture of rice straw and mixed expeller cake, organic source in organic cultivation of tomatoes. METHODS AND RESULTS: There was no difference in all treatments in case of 200 mg/kg in the nitrate nitrogen content in soil prior to the first cropping season test under the criteria for nitrogen nutrient based on yield of crops, cultivation without fertilizers seems possible. But in the second cropping season, no treatment and rice straw showed the reduction of yield and in the third cropping season, rice-straw+mixed expeller cake 0.5 N treatment showed the significant difference. The content of nitrate nitrogen in soil prior to cropping seasons was evaluated in 160 mg/kg and standard fertilization such as mixed expeller cake, source of nitrogen, are needed due to the deficiency of nitrogen. In terms of application of organic resources, rice straw showed the effects of improvements on physical properties of soil such as bulk density, cation exchange capacity and humus contents, but the mixed expeller cake did not show any significant differences in improvements on physical properties of soil. CONCLUSION(s): Fertilizer management in organic cultivation of tomatoes is thought to produce the reliable quantity of crops as well as keep the high quality of soils by using the optimal application rate of mixed expeller cake according to the contents of nitrate nitrogen in soil and rice straw which improves the physical properties of soil.

Effect of universal primer on shear bond strength between resin cement and restorative materials (다용도 프라이머가 레진 시멘트와 수복재의 전단 결합 강도에 미치는 영향)

  • Kim, Na-Hong;Shim, June-Sung;Moon, Hong-Suk;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.112-118
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate the difference in shear bonding strength between resin cements to dental materials when a universal primer (Monobond plus) was applied in place of a conventional primer. Materials and methods: Four groups of testing materials: gold alloy (Argedent Euro, n = 16), non precious metal (T-4, n = 20), zirconia (Cercon, n = 20) and glass ceramic (IPS e.max press, n = 20), were fabricated into discs, which were embedded in an acrylic resin matrix. The gold alloy specimens were airborne-particle abraded, 8 of the specimens were coated with Metal primer II, while the remaining 8 specimens were coated with Monobond plus. The non precious and zirconia specimen were airborne-particle abraded then, the control group received Alloy primer coating, while the other was coated with Monobond plus. Glass ceramic specimens were etched. 10 specimens were coated with Monobond-S and the remaining specimens were coated using Monobond plus. On top of the surface, Multilink N was polymerized in a disc shape. All of the specimens were thermal cycled before the shear bonding strength was measured. Statistical analysis was done with Two sample $t$-test or Mann-Whitney U test (${\alpha}$=.05). Results: There were no significant differences in bonding strength depending on the type of primer used in the gold alloy and glass ceramic groups ($P$>.05), however, the bonding strengths of resin cements to non precious metal and zirconia groups, were significantly higher when the alloy primer was used ($P$<.05). Conclusion: Within the limitations of this study, improvement of universal primers which can be applied to all types of restorations is recommended to precious metals and zirconia ceramics. But, the bond strengths of non precious metals and zirconia ceramics were significantly lower when compared to a 10-MDP primer. More research is needed to apply universal primers to all types of restorations.

Motion Analysis of Light Buoys Combined with 7 Nautical Mile Self-Contained Lantern (7마일 등명기를 결합한 경량화 등부표의 운동 해석)

  • Son, Bo-Hun;Ko, Seok-Won;Yang, Jae-Hyoung;Jeong, Se-Min
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.5
    • /
    • pp.628-636
    • /
    • 2018
  • Because large buoys are mainly made of steel, they are heavy and vulnerable to corrosion by sea water. This makes buoy installation and maintenance difficult. Moreover, vessel collision accidents with buoys and damage to vessels due to the material of buoys (e.g., steel) are reported every year. Recently, light buoys adopting eco-friendly and lightweight materials have come into the spotlight in order to solve the previously-mentioned problems. In Korea, a new lightweight buoy with a 7-Nautical Mile lantern adopting expanded polypropylene (EPP) and aluminum to create a buoyant body and tower structure, respectively, was developed in 2017. When these light buoys are operated in the ocean, the visibility and angle of light from the lantern installed on the light buoys changes, which may cause them to function improperly. Therefore, research on the performance of light buoys is needed since the weight distribution and motion characteristics of these new buoys differ from conventional models. In this study, stability estimation and motion analyses for newly-developed buoys under various environmental conditions considering a mooring line were carried out using ANSYS AQWA. Numerical simulations for the estimation of wind and current loads were performed using commercial CFD software, Siemens STAR-CCM+, to increase the accuracy of motion analysis. By comparing the estimated maximum significant motions of the light buoys, it was found that waves and currents were more influential in the motion of the buoys. And, the estimated motions of the buoys became larger as the sea state became worser, which might be the reason that the peak frequencies of the wave spectra got closer to those of the buoys.

INFLUENCE OF LIGHT IRRADIATION OVER SELF-PRIMING ADHESIVE ON DENTIN BONDING (상아질접착제에 대한 광조사가 접착에 미치는 영향)

  • 류현욱;김기옥;김성교
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.5
    • /
    • pp.409-417
    • /
    • 2001
  • The purpose of this study was to investigate the influence of light irradiation over self-priming adhesive on dentin bonding. After acid etching the exposed dentin, a self-priming adhesive (Prime&Bond$^{\circledR}$NT dental adhesive system Dentsply DeTrey, GmbH, Konstanz, Germany) was applied and light irradiation was done for 20 sec with regular intensity (600 mW/$\textrm{cm}^2$) in group I and for 3 sec with ultra-high intensity (1930 mW/$\textrm{cm}^2$) in group III. No light irradiation was done over self-priming adhesive in groups II and IV. Composite resin was added on the self-priming adhesive and irradiated for 40 sec with regular intensity (600 mW/$\textrm{cm}^2$) in groups I and II and for 3 sec with ultra-high intensity (1930 mW/$\textrm{cm}^2$) in groups III and IV. To see the effect of light curing time on dentin bonding, another 3 group specimens were prepared. Without light-irradiation over self-priming adhesive, added composite resin was irradiated for 3, 6, or 12 sec with ultra-high intensity light. After bonded specimens were stored in 37$^{\circ}C$ distilled water for 24 hours, shear bond strength were measured using a universal testing machine (4202, Instron, Instron Co., U.S.A.) and fractured surfaces were examined under a stereomicroscope (SZ-PT Olympus, Japan). Statistical analysis were done with one-way, two-way ANOVA and chi-square test. The results were as follows : 1. The shear bond strengths from the groups irradiated over self-priming adhesive were significantly higher than those from the groups without irradiation (p<0.05). 2. There was no significant shear bond strength difference between regular intensity light irradiation groups and ultra-high intensity ones (p>0.05). 3. There was no significant shear bond strength difference among various irradiation time groups with ultra-high intensity ones (p>0.05). 4. In stereomicroscopic examination of fractured surfaces, adhesive-cohesive mixed failure mode was mostly seen in all groups, and there was no significant difference in failure mode among groups (p>0.05).

  • PDF