• Title/Summary/Keyword: 부식촉진실험

Search Result 83, Processing Time 0.027 seconds

Local Corrosion and Fatigue Damages of Steel Plates at the Boundary with Concrete (콘크리트에 접해있는 강재의 국부부식과 피로손상)

  • Kim, In Tae;Kainmua, Shigenobu;Cheung, Jin Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.2
    • /
    • pp.313-321
    • /
    • 2008
  • Recently in Japan, fracturing was observed on the diagonal member of a through truss bridge at the boundary region with the concrete slab. Local corrosion damage where the diagonal member was enclosed in the concrete slab is an important factor in the fracture. In this study, accelerated exposure tests were carried out on concrete-steel model specimens simulating steel members at the boundary with concrete. Fatigue tests were then performed on the corroded model specimens. Accelerated exposure tests of the S6-cycle, which is carried out on the model specimens for 150, 300, 450 and 600 da ys. Their surface geometry was then measured. From the accelerated exposure test results, change in maximum and mean corrosion depths was determined according to the testing periods. The effect of local corrosion on fatigue strength was also presented based on the fatigue test results.

Corrosion Durability Evaluation of Uncoated Structural Steel Using Accelerated Exposure Tests (부식촉진실험을 이용한 강교용 무도장 강재의 부식내구성 평가)

  • Kim, In Tae;Itoh, Yoshito
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.1
    • /
    • pp.79-86
    • /
    • 2007
  • The corrosion durability of steel bridge coatings, such as organic and metallic coatings, is often evaluated by field exposure tests, but such tests take from several years to decades to complete. As a potential method for fast corrosion testing, accelerated exposure tests were considered in this study. The S6-cycle accelerated exposure test, specified in the Japanese Industrial Standards (JIS K5621), was carried out on uncoated structural steels for 30, 60, 90, 120 and 150 days, and the resultant weight loss was determined. The weight loss was compared with that obtained from previous field exposure tests, and acceleration factors of the S6-cycle test to field exposure test sites were determined. The application of the S6-cycle accelerated exposure tests to field environments was presented based on the acceleration factor and the amount of flying salt.

콘크리트에 매입된 철근부식에 대한 전기특성 고찰

  • 최종범;김찬오;손기상
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2001.11a
    • /
    • pp.147-152
    • /
    • 2001
  • 국내외적으로 철근부식에 영향을 받아 콘크리트가 변하는 특성을 실험적으로 연구한 논문이 많이 발표되고 있다. 본 연구에서는 이들 기존 연구에서 시행된 부식촉진방법, 주로 전기적인 방법을 다양한 실험을 통하여 최적방법을 찾고자 하는데 있다. 기존의 연구 중에는 "전위차 부식촉진법을 이용한 철근 콘크리트의 내부식성 예측을 위한 새로운 기법 연구"에서는 20V 직류전원장치를 NaCl용액에 직류회로를 구성한 후 양극과 음극의 전위차를 이용 전류량을 측정한 방법이 있었으며, 철근부식을 일으키는 많은 원인은 염소이온에 의한 것이다. 철근의 부식반응은 전기화학적 반응이다. 부식콘크리크 실험에 많이 이용하고 있는 자연전위법, 분극저항법, 콘크리트저항법들이 있다.(중략)

  • PDF

Corrosion-bond Strength Evaluation in OPC and Slag Concrete using Accelerated Corrosion Test (촉진부식실험을 이용한 OPC 및 슬래그 콘크리트의 부식-부착강도 평가)

  • Sang-Jin Oh;Hyeon-Woo Lee;Seung-Jun Kwon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.12 no.1
    • /
    • pp.1-7
    • /
    • 2024
  • Concrete, as a porous construction material, permits chloride penetration from outside, which yields corrosion in embedded steel. In the study, an accelerated corrosion technique (ICM: Impressed current method) was adopted for rapid corrosion formation with 10 Volt of potential, and corrosion amou nt was controlled u p to 10.0 %. Corrosion amou nt had a linear relationship with cumulative corrosion current and increased with a quadratic function of accelerating period due to cracking. Regarding bond strength test, OPC concrete showed rapid drop of bond strength over 3.0 % of corrosion weight ratio, however slag concrete with 30 % replacement ratio showed a level of 51.4~71.6 % of corrosion ratio to OPC concrete with keeping residual bond strength.

A New Method on the Prediction of Corrosion Resistance of Reinforced Concrete Using Accelerated Potentiometric Corrosion Method (전위차 부식촉진법을 이용한 철근 콘크리트의 내부식성 예측을 위한 새로운 기법 연구)

  • 오병환;조윤구;차수원;정원기
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.5
    • /
    • pp.201-209
    • /
    • 1996
  • Recently, large scale concrete structures exposed to severe environment are increasingly built in various locations. The corrosion may severely affect the durability and service life of such a concrete structure. It is, therefore, necessary to develop durable concrete to enhance the corrosion resistance. The corrosion resistance of concrete can be identified through accelerated corrosion test. The purpose of the present paper is, therefore, to devise a reasonable and accurate method to predict the amount of corrosion of reinforcing steels. The proposed method which is basically based on the concept of Faraday's Law, determines the corroded amount of a rebar according to accelerated corrosion time. The corrosion is accelerated by employing the potentiometric corrosion test arrangement. The effects of admixtures in concrete including fly ash and silica fume have been also studied to explore the relative corrosion resistance of concrete.

A Study of Accelerated Corrosion Test and Chloride Penetration Analysis with Artificial Seawater Immersion Condition (인공해수 침지조건에 따른 부식촉진시험과 염화물침투해석에 대한 연구)

  • Park, Sang-Soon;Jeong, Ji-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.1
    • /
    • pp.93-100
    • /
    • 2014
  • Steel reinforcement buried in concrete structure in submerged zone does not easily become corroded due to lack of dissolved oxygen. For that reason, accelerated corrosion test in submerged state is performed with an electrochemical method, which is not suitable for actual corrosion mechanism and makes it difficult to find relevance with long-term behavior. In this study, accelerated corrosion test was performed with the temperature and chloride concentration as main variables in order to establish a method for accelerated corrosion test in submerged zone. Corrosion was determined by the result of reinforcement corrosion monitoring based on galvanic potential measurement and half-cell potential method. The accelerated corrosion test result showed that temperature had the most dominant influence. To determine the chloride content, chloride concentration by depth in the test sample was measured. With the same conditions, chloride penetration interpretation was performed by DuCOM, a FEM durability interpretation program. Also, a test was performed to measure dissolved oxygen according to soaking conditions of artificial seawater, which was used for verifying the validity of the accelerated corrosion test result.

HCP Evaluation Considering Property of Cement Mortar and Steel Corrosion (건조 상태의 시멘트 모르타르 특성과 철근 부식량을 고려한 HCP 평가)

  • Ryu, Hwa-Sung;Yoon, Yong-Sik;Kwon, Seung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.2
    • /
    • pp.113-120
    • /
    • 2017
  • HCP(Half Cell Potential) method has been widely used since it is recognized as a efficient NDT(Non Destructive Technique) for corrosion detection. This work is for an evaluation of relation between corrosion amount and measured HCP in dried condition through ICM(Impressed Current Method) for accelerating corrosion. For the work, cement mortar specimens with three w/c ratios and four cover depths are prepared, and corrosion test based on ICM is performed for 6 hours, 18 hour, and 42 hours with constant 20V of electrical charge, respectively. From the test, corrosion amount increases with reduced cover depth, increasing w/c ratio, and extended corrosion period, where corrosion amount is evaluated to linearly increases with measured HCP in dried condition. In order to evaluate corrosion amount through measured HCP, the measured HCP level is firstly determined and then corrosion amount is to be compared with measured HCP, which is evaluated to be more reasonable with higher C.O.V.

Evaluate the Concrete mix by Type Accelerated Corrosion Test and Chloride Penetration Analysis with Artificial Seawater Cyclic Wet and Dry Condition (인공해수 건습반복조건에 따른 콘크리트배합별 부식촉진시험법과 염화물 침투해석평가)

  • Park, Sang-Soon;Kim, Min-Wook
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.3
    • /
    • pp.211-218
    • /
    • 2013
  • Cyclic wet and dry conditions in the marine environment structures corrosion is known to be the fastest rising. For that reason, accelerated corrosion test methods for the reproduction of tidal environment has been actively conducted. However, many studies have estimated threshold value for steel corrosion or concentrated in chloride penetration analysis. In this study, cyclic wet and dry conditions to reproduce the structure of the environment in accelerated corrosion and chloride penetration test analysis was performed. Corrosion was determined by the result of reinforcement corrosion monitoring based on galvanic potential measurement and half-cell potential method. Accelerated corrosion test results for each formulation was different corrosion periods, the order OPC> FA> BS> High-strength concrete. FEM durability interpretation program DuCOM was conducted under the same conditions as in accelerated corrosion test. The experimental RCPT tests demonstrated the validity of the result.

Suggestion of Deterioration Curve for New-type Coating on Atmospheric Environment by Acceleration Corrosion Test (부식촉진 실험을 통한 대기환경에서 신설 도장계의 노화곡선 제안)

  • Jeong, Young-Soo;Kim, Min-Jeong;Jeon, Seok-Hyeon;Ahn, Jin-Hee;Kim, In-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.2
    • /
    • pp.75-83
    • /
    • 2019
  • In this study, to propose the deterioration curves of urethane, ceramic, polysiloxane and fluorocarbon coating for the steel bridge, an accelerated corrosion tests were carried out. The each coating system wes applied on the top of the specimens, and circular initial defects were introduced with different diameters with 0.5, 1.0, 3.0, 5.0 mm. An accelerated corrosion test condition was used to simulate severe corrosive environment depending on ISO 20340. The deterioration curve of each coating type was evaluated based on deteriorated area from the circular defects. In order to evaluate the coating service life of installed steel bridge using deterioration curve, the acceleration coefficient was calculated at correlation between ISO 20340 and corrosivity categories by ISO 9223 based on field corrosion rate. From test results, the propagation rate of coating deterioration area was different to diameter of circular defects. In case of urethane coating, the coating service lifes of 3% deterioration area was evaluated in 31.8, 15.8, 9.9 and 3.9 years with C2, C3, C4 and C5 category.

A Study on the Change of the Corrosion Products by the Activity of Iron Reducing Bacteria for Corrosion Carbon Steel (부식철편에 있어서 철환원능력을 갖춘 세균의 활동에 의한 부식생성물의 변화)

  • Lee, So-Yeon;Matsui, Toshiya;Yoshikawa, Hideki
    • Journal of Conservation Science
    • /
    • v.26 no.4
    • /
    • pp.407-416
    • /
    • 2010
  • Bacteria with ability for iron reduction in the soil can use corrosion products of iron remains as energy source. The activities of this bacteria cause the change of corrosion products. As a result, it can be difficult to identify corrosion products promoting corrosion of iron remains. The purpose of this study, is to investigate the change in corrosion products that bacteria causes and to improve understanding about the corrosion of iron remains. To simulate corroded condition of excavated iron remains, carbon steel corroded by solution of NaCl and $Na_2SO_4$ was prepared. Then the prepared carbon steel was immersed in a liquid medium with bacteria. The incubation period was 42days. After experiment, the carbon steel was analyzed by SEM-EDS, X-ray diffraction method. The result is that the carbon was changed to green because of activity of bacteria and that the plate crystal and lozenge crystal were generated on the corrosion specimen. Also, we confirmed that the activities of bacteria differenciated colors and forms of corrosion products.