Erosion-Corrosion Behavior of Power Plant Pipe Caused by Hot Feed Water (고온 급수에 의한 파워 플랜트 배관 침식-부식 거동)

  • Bang, Sung-Ho;Lee, Jin-Won;Kim, Tae-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.6
    • /
    • pp.739-745
    • /
    • 2013
  • In this study, we tried to define the erosion-corrosion behavior together with the resulting effects on a pipe that is a part of a feed water circulation system according to the pipe size and hot feed water environment. An erosioncorrosion analysis was performed through the Hayduk and Minhas model based on the chemical reaction between iron and oxygen, an essential corrosive factor. The erosion-corrosion rate against the pipe diameter and feed water temperature was then evaluated by means of finite element analysis using ABAQUS. As shown in the results, the feed water temperature was the main factor influencing the erosion-corrosion rate; in particular, it was expected that the thickness of 316 stainless steel would decrease by $2.59{\mu}m$ every year in a hot water environment at $290^{\circ}C$.

Characteristics for Reinforcement Corrosion and Chloride Ion Diffusion of High Volume Fly Ash Concrete (하이볼륨 플라이애시 콘크리트의 철근부식 및 염소이온 확산 특성)

  • Kwon, Soon-Oh;Bae, Su-Ho;Lee, Hyun-Jin;Jung, Sang-Hwa
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.1
    • /
    • pp.34-39
    • /
    • 2014
  • The purpose of this experimental research is to evaluate the resistance of reinforcement corrosion and chloride ion penetration of high volume fly ash (HVFA) concrete. For this purpose, concrete test specimens were made for various strength level and replacement ratio of fly ash, and then compressive strength and diffusion coefficient for chloride ion of them were measured for 28, 91 and 182 days, respectively. Also, corrosion monitoring by half cell potential method was carried out for the made lollypop concrete test specimens to detect the time of corrosion initiation for reinforcement in concrete. As a result, it was observed from the test results that compressive strength of HVFA concrete was decreased with increasing replacement ratio of fly ash but long-term resistance against reinforcement corrosion and chloride ion penetration of that was increased.

Evaluation of Corrosion Effects on Permanent Ground Anchors (영구 지반앵커에 대한 부식의 영향 평가)

  • Park, Hee-Mun;Park, Seong-Wan
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.2
    • /
    • pp.27-36
    • /
    • 2004
  • The corrosion rate measurement procedure for the permanent ground anchors using polarization resistance measurements and electrochemical impedance spectroscopy is presented in this paper. The polarization resistance measurements were used to determine the correlation between corrosion rate in the steel and soil characteristics. The electrochemical impedance spectroscopy was used to predict the time dependent corrosion reaction and evaluate the different type of coating systems and the effect of cement grouting on the corrosion attack under various conditions. The results indicate that a low pH soil is a good indicator of a corrosive soil. The low pH soil condition (<5) in both clay and sand has a significant effect on the corrosion reaction of steel members in permanent found anchors. In the case of neutral and alkaline conditions beyond pH 6 in clay and sand, no consistent acceleration of corrosion was measured and the corrosion rate was constant regardless of variations of soil pH levels. Laboratory test data for porcelain clay indicate that the change of soil pH level has a small influence on the corrosion reaction in the steel member. The use of cement footing in the bonded length is sufficient to decrease the corrosion rate to a level close to 0.003∼0.01mm/y at the end of the given period. With epoxy and fusion bonded epoxy coating, the steel specimens remained unaffected and retained the original condition. It is suggested that epoxy and fusion bonded epoxy coating can provide effective protection against corrosion for a long time even in aggressive environment.

Impact assesment of zooplankton by turbine of tidal power plant in Uldolmok waterway, Korea (울돌목 해역에서 조류발전 시설 터빈 가동에 따른 동물플랑크톤의 피해 영향)

  • Yoo Jeong-kyu;Nam Eun-jung;Myung Chul-soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.507-511
    • /
    • 2005
  • 울돌목은 조류발전의 세계적인 최적지로 꼽히고 있으며 서해와 남해의 점이 지대로서 조류에 의해 해양 생물 군집의 대량 이동이 빈번한 곳이라 할 수 있다. 조류 발전 시설인 터빈의 가동은 물리적인 충격에 의해 해양 생물의 생태-생리 반응에 영향을 미칠 가능성이 있다. 네트를 이용한 1차 조사에서 터빈 가동에 의한 동물플랑크톤의 순 사망률은 $44.3\%$로 나타났다. 1차 조사 이 후 다이아프램 펌프를 이용한 조사 결과 중 출현 개체수가 높았던 조사에서 전체 동물플랑크톤의 순 사망률은 각각 $7.3\%,\;5.8\%$를 나타내었고, 요각류는 각각 $4.4\%,\;5.2\%$를 나타냈다. 물리적인 충격을 인위적으로 가한 실험에서 스트레스를 받은 요각류 Acartia hongi의 알 생산은 스트레스를 받지 않은 것보다 $1.8\~2.3$배 낮은 경향을 보였다. 본 조사에서 동물플랑크톤이 낮은 사망률을 보골 이유는 작은 크기의 생물이 우점하였기 때문이며 조사 결과에서 몸체가 비교적 단단하고 크기가 작은 요각류는 상대적으로 약한 부유유생보다 높은 생존율을 보였다. 울돌목 조사 해역에서 출현한 동물플랑크톤은 크기가 작아 터빈의 물리적인 충격에 의한 사망률은 낮을 수 있으나 순간적으로 강한 스트레스를 받는다면 재생산을 포함한 생리활동이 저하될 수 있음을 보였다. 네트 및 펌프를 이용한 조사 결과에서 네트에 의한 채집은 터빈의 영향뿐만 아니라 빠른 유속으로 인하여 네트가 받는 압력에 의해 생물체가 손상되는 양상이 높아 사망률이 높았던 것으로 보인다. 그러나 다이아프램 펌프는 생물 채집 시 오류를 최소화하는 장점은 있으나 채집의 장시간에 비해 매우 적은 생물량이 채집되는 단점을 보였다TEX>$96.5\%$에 미달하는 문제는 식물성 원료유로 제조한 고순도 바이오디젤과 혼합 사용하거나 감압 증류 공정을 통해 고농도의 폐식용유 바이오디젤을 제조하여 해결 가능하다. 대전시 신성동 소재의 음식점에서 수거한 폐식용유를 원료로 하여 생산한 바이오디젤의 차량 배출가스 실증 테스트 결과 경유 차량의 주 오염물질인 PM과 Soot 및 기타 오염물질의 배출량은 감소하였으나 NOx의 배출량은 약간 증가하는 것으로 나타났다구와 이해를 바탕으로 보존대책이 마련되어야 한다.되었다. 이런 모든 시편들을 각 탈염방법에 따라 탈염처리한 후 XRD와 SEM-EDS으로 분석한 결과 인철광과 침철광은 어떠한 변화도 보이지 않았고, 다만 적금광으로 동정된 시편만이 잔존하지 않았다. 철기 제작별 $Cl^-$ 이온 추출량과 탈염효과에 대한 비교 실험은 이온 크로마토그래피 분석 결과와 마찬가지로 단조 철제유물이 주조 철제보다 $Cl^-$ 이온을 많이 가지고 있었으며, 탈염 처리 후에는 $Cl^-$ 이온은 전혀 발견되지 않았다. 이상의 결과 $K_2CO_3$와 Sodium 용액은 탈염처리에서 가장 적합한 탈염처리 용액으로 알수가 있었으며 특히 어떠한 탈염 용액으로 유물을 처리한다 해도 철제유물에 생성된 부식물은 제거되지 않는다는 것을 알게 되었다. 따라서 보존처리자는 유물 표면의 부식 상태만을 보고 처리하기 보다는 철기제작물로 고려하여 처리하는 것이 필요하다. 또한 금속에 부식을 야기시키는 $Cl^-$ 이온과 부식물을 완전하게 제거하여 탈염처리를 하는 것이 유물 부식을 최대한 지연시킬 수 있는 것이라 생각된다.TEX>$88\%$)였다.(P=0.063). 결론: 본

  • PDF

Corrosion Resistance of Cr-bearing Rebar to Macrocell Corrosion Caused by Concrete with Crack (피복 콘크리트의 균열 발생에 기인한 매크로셀 부식 환경하에서의 Cr강방식철근의 방식성)

  • Tae, Sung-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.4
    • /
    • pp.79-86
    • /
    • 2006
  • This study was investigated to corrosion resistance of Cr-bearing rebars to macrocell corrosion caused by concrete with crack. Ten types of steel bars having different Cr contents were embedded in concretes with imitation crack. The corrosion resistance of the Cr-bearing rebar was examined by measuring half-cell potential, macrocell corrosion current, corrosion area and weight loss up to 105 cycles of salt spray testing. The results revealed that the Cr content required for corrosion resistance in a macrocell corrosion environment caused by chloride ion gap of $3kg/m^3$ was 9% or more. The corrosion-resisting performance of Cr-bearing rebar was particularly noticeable with a Cr content of 11% or more.

An Evaluation on the Mechanical Performance of a Corroded Rebar as the Corrosion Pattern of Rebar in Concrete (콘크리트중에서의 철근부식형태에 따른 부식철근의 역학적 특성에 관한 연구)

  • Kim, Hyung-Rae
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.393-396
    • /
    • 2008
  • The purpose of this paper is to find out quantitatively the relationship between the surface shape and the mechanical properties of corroded reinforcement. Three-dimensional measurements were carried out on the surface shape of variously corroded reinforcements and parameters expressing the characteristics of the shape, which included the maximum decrement of sectional area of reinforcement, its distribution along the axis. It was investigated that which parameters could correspond to the mechanical properties of corroded reinforcement and it was confirmed that the maximum decrement of sectional area of reinforcement could express the mechanical properties most appropriately. Finally, this paper proposes a constitutive model of corroded reinforcement for analyzing the structural behavior of reinforced concrete structures considering the localized corrosion of by finite element method.

  • PDF

원전 출력감발 운전에 따른 방사성 부식생성물 거동 분석

  • 성기방
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11a
    • /
    • pp.103-109
    • /
    • 1996
  • 고리 원자력 1호기 14주기(‘95년도) 운전기간 중 증기발생기 세관 열전달 용량 저하로 전출력 운전 기간동안 정격출력보다 15% 감발 운전한 경험이 있었는데, 이 기간중 냉각재내 방사성 부식생성물(CRUD) 농도가 약 80% 감소됨을 발견하였다. 이때 출력감소 비율보다 많은 CRUD 감소현상 규명을 위해 냉각재 수질관리인자와 EPRI 피복재 부식모델인 PFCC코드를 사용한 피 복재 산화물 두께변화 등을 비교한 결과, 운전중 용출되는 방사성 부식생성물은 핵연료 표면의 피복재 산화물에 흡착된 Co핵종이 피복재 산화물 이탈시 함께 거동하는 것으로 확인되었으며, 피복재 산화물 이탈은 산화막 두께 및 열유속에 주로 의존함이 밝혀졌다. 따라서 냉각재내에서 방사성 부식 생성물의 생성률 저감을 위해서는 정상운전시 핵연료 표면의 산화막 증가를 억제할 수 있는 수질 조건을 도출하고 그에따른 운전을 통해 원전 작업자의 방사선 피폭량 저감 및 방사성폐기물의 발생을 줄일 수 있을 것으로 여겨진다.

  • PDF

A Study on the Characteristics for AC Corrosion of Gas Pipelines (가스배관의 교류부식 특성에 관한 연구)

  • Bae Jeong-Hyo,;Ha Tae-Hyun,;Lee Hyun-Goo,;Kim Dae-Kyeong,
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.3 s.15
    • /
    • pp.29-35
    • /
    • 2001
  • Direct current corrosion have being investigated by lots of scientists but alternating current corrosion was ignored because the corrosion rate by AC was very small. Recently however, AC corrosion accidents have been reported in many other countries. So the study of AC corrosion is to be necessary In these days. In this paper, several experiments which intentionally imposed the AC or DC to the specimens also imposed AC and DC at the same time was carried out in the laboratory to examine the AC corrosion characteristics and in addition applied the same way in the field. Moreover, while the field investigations of the abnormal corrosion failures, It was the AC that caused one of corrosion failures.

  • PDF

Residual life and probability of pipe breakage according to pipe corrosion (상수도관의 부식에 따른 잔존수명 및 파괴확률)

  • Lee, Jae Hyeon;Kim, Hyeong Gi;Kwon, Hyuk Jae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.420-420
    • /
    • 2021
  • 상수도관은 시간이 경과됨에 따라 부식이 발생하고 이로 인해 관의 두께 및 강도가 감소하여 점차 상수도관의 기능을 상실하게 된다. 이러한 노후 상수도관은 누수, 적수 등 수자원에 막대한 경제적인 손실을 발생시키고 사람들에게 많은 불편을 끼친다. 현재 우리나라도 전체 상수도관 중 노후 상수도관이 많은 부분을 차지하고 있기 때문에 교체나 개선이 시급한 실정이다. 하지만 전체 상수도관을 교체하는 것은 막대한 예산이 필요하기 때문에 현실적으로 어려운 문제이다. 따라서 상수도관의 노후도 분석을 통하여 상수관망의 최적 교체 우선순위를 판단하고 교체를 실시하는 것이 필요하다. 본 연구에서는 노후도 분석에 중요한 관의 부식깊이와 잔존수명을 예측하고 신뢰성해석을 통해 파괴확률을 산정하였다. 이를 위해 Romanoff(1957)와 환경부(2002)에서 실측한 상수관의 관종에 따른 관두께 변화를 적용하여 해석하였다. 실측 자료를 통해 부식깊이, 잔존수명 예측 모델을 수립하였으며 이에 따른 관의 파괴확률을 산정하였다. Romanoff(1957)의 혼합강관과 주철관에 대한 실측 자료를 사용하여 상수관의 사용연수가 10년, 20년, 30년 경과됨에 따른 부식깊이와 관파괴확률을 산정하였다. 혼합강관의 경우 사용연수에 따른 부식깊이는 0.57mm, 0.92mm, 1.21mm으로 산정되었으며, 주철관의 경우 0.16mm, 0.24mm, 0.31mm으로 산정되었다. 또한 신뢰성모형을 직경 300mm관에 적용한 결과 최대 상수도압 15kg/cm2에서 혼합강관의 사용연수에 따른 파괴확률은 3.36%, 4.65%, 6.18%로 나타났으며 주철관은 1.36%, 2.50%, 2.68%로 나타났다. 환경부(2002)의 주철관에 대한 부식 실측 자료를 통해 상수관의 사용연수 10년, 20년, 30년 경과에 따른 부식깊이와 관파괴확률을 산정하였으며 초기 관두께 측정 자료를 통해 잔존수명도 예측하였다. 부식깊이는 1.02mm, 1.25mm, 1.41mm으로 산정되었으며, 파괴확률은 5.15%, 6.30%, 7.35%로 산정되었다. 그리고 잔존수명의 경우 부식률이 20%일 때, 잔존수명은 약 30년으로 산정되었다.

  • PDF

Corrosion-bond Strength Evaluation in OPC and Slag Concrete using Accelerated Corrosion Test (촉진부식실험을 이용한 OPC 및 슬래그 콘크리트의 부식-부착강도 평가)

  • Sang-Jin Oh;Hyeon-Woo Lee;Seung-Jun Kwon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.12 no.1
    • /
    • pp.1-7
    • /
    • 2024
  • Concrete, as a porous construction material, permits chloride penetration from outside, which yields corrosion in embedded steel. In the study, an accelerated corrosion technique (ICM: Impressed current method) was adopted for rapid corrosion formation with 10 Volt of potential, and corrosion amou nt was controlled u p to 10.0 %. Corrosion amou nt had a linear relationship with cumulative corrosion current and increased with a quadratic function of accelerating period due to cracking. Regarding bond strength test, OPC concrete showed rapid drop of bond strength over 3.0 % of corrosion weight ratio, however slag concrete with 30 % replacement ratio showed a level of 51.4~71.6 % of corrosion ratio to OPC concrete with keeping residual bond strength.