• Title/Summary/Keyword: 본차아

Search Result 110, Processing Time 0.036 seconds

Comparison of the Efficacy of Disinfectants to Control Caseous Lymphadenitis in Korean Black Goat Farms (흑염소의 건락성 림프절염 제어를 위한 소독제 효능 비교)

  • Cho, Hyeunwoo;Kim, Yeona;Jang, Beomsoon;Kim, Chan-Lan;Park, Kun Taek
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.5
    • /
    • pp.317-322
    • /
    • 2022
  • Corynebacterium pseudotuberculosis is the causative agent of caseous lymphadenitis (CLA), a chronic contagious disease in small ruminants. The prevalence of CLA has been reported to be >50% in Korean black goats. CLA is difficult to control due to a lack of efficient vaccines and treatment methods. Effective disinfection of the farm environment may be an alternative strategy for reducing the spread of C. pseudotuberculosis. The objective of this study was to evaluate the efficacy of commercial disinfectants against CLA. The six commercial disinfectants, largely composed of sodium dichloroisocyanurate, sodium hypochlorite, potassium monopersulfate triple salt, quaternary ammonium, citric acid, and copper sulfate, were tested against five different genotypes of C. pseudotuberculosis isolated from goat farms in Korea. Efficacy tests were performed in accordance with the disinfectant efficacy test guidelines recommended by the Animal and Plant Quarantine Agency of Korea with slight modifications. All disinfectants except for copper sulfate exhibited >99.99% killing efficacy under hard water conditions following 30 min of incubation, which is the recommended standard treatment time according to guidelines. The minimum bactericidal treatment time was evaluated by employing treatments for durations of 1, 5, and 15 min. The most effective compounds under hard water conditions were sodium dichloroisocyanurate, potassium monopersulfate triple salt, and sodium hypochlorite, exhibiting >99.99% killing efficacy after 1 min of treatment. In the aqueous solution forms, citric acid and the quaternary ammonium compound were the most effective, but required at least 5 min to kill >99.99% of the bacteria. The current study characterizes the killing efficacy of six commercial disinfectant active compounds against C. pseudotuberculosis. Thus, this study provides essential information regarding the efficacy of the disinfectants used to control CLA in goat farms.

Application of Ceramic MF Membrane at the Slow Sand Filtration Process (완속모래여과 공정에서 세라믹 MF 막의 적용)

  • Choi, Kwang-Hun;Park, Jong-Yul;Kim, Su-Han;Kim, Jeong-Sook;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.12
    • /
    • pp.877-882
    • /
    • 2013
  • The application of ultrafiltration (UF) and microfiltration (MF) membranes has been increased for drinking water purification. The advantages of UF/MF membrane process compared to conventional treatment processes are stable operation under varying feed water quality, smaller construction area, and automatic operation. Most membrane treatment plants are designed with polymeric membranes. Recently, some studies suggested that the process of treating surface water with ceramic membranes is competitive to the application of polymeric membranes. Higher water flux, less frequent cleaning, and much longer lifetime are the advantages of ceramic membrane comparing to polymeric membrane. Therefore, this research focused on the application of ceramic MF membrane pilot plant at the slow sand filtration plant. The ceramic membrane pilot plant has three trains that used raw water and sand filtered water as a feed water, respectively. For optimizing the pilot plant process, the coagulation with PACl coagulant was used as a pretreatment of ceramic membrane process. In addition, CEB (Chemical Enhanced Backwash) process using $H_2SO_4$ and NaOCl was used for 1.5 days, respectively. The experimental results showed that applying the optimum coagulant dose before membrane filtration showed enhancing membrane fluxes for both raw water and sand filtered water. Also, when using raw water as a feed of membrane, minimum fouling rate was 2.173 kPa/cycle with 25 mg/L of PACl and when using sand filtered water, the minimum fouling rate was 0.301 kPa/cycle with 5 mg/L of PACl.

Comparison of Characteristics on Electrolyzed Water Manufactured by Various Electrolytic Factors (전해인자에 따른 전기분해수의 특성 비교)

  • Kim, Myung-Ho;Jeong, Jin-Woong;Cho, Young-Je
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.416-422
    • /
    • 2004
  • Efficacy of surface sterilization and physicochemical properties of electrolyzed water manufactured depending on electrolyte, materials, and type of electrolytic diaphragm used were investigated. Physical properties of electrolyzed water manufactured from diaphragm system showed the highest effectiveness under at distance between diaphragms of 1.0 mm and 20% NaCl supplying rate of 6 mL/min. ORP, HClO (should defined) content, and pH at above conditions were 1,170 mV, 100 ppm, and 2.5, respectively. Two-stage electrolyzed system was more effective than one-stage one. Electrolyzed water manufactured from non-diaphragm system at 4 mL/min supplying rate of 20% NaCl was similar to the most effective diaphragm system, whereas ORP, HClO content, and pH were 800 mV, 200 ppm, and 9, respectively. Sealed electrolyzed water could be preserved more than one month at room temperature with ORPs of 750 and 1,150 mV in non-diaphragm and diaphragm systems, respectively, and at HClO content of 100 ppm. Physicochemical properties of electrolyzed water manufactured from electrolytic diaphragm of $IrO_{2}$ and Pt+Ir were more effective than that of Pt. ORP and HClO contents of electrolyzed water manufactured from various electrolytes were high in order of NaCl>KCl>$CaCl_{2}$, whereas no differences were observed among electrolytes in sterilization efficacy. Twelve kinds of microorganisms tested (initial total count, $10^{5}-10^{6}CFU/mL$) were sterilized within 1-2 min by electrolyzed water.

Effect of Electrolyzed Water and Citric acid On Quality Enhancement and Microbial Inhibition in Head Lettuce (전해수와 구연산을 이용한 양상치의 품질 향상 및 미생물 저감화 효과)

  • Jin, Yong-Guo;Kim, Tae-Woong;Ding, Tian;Oh, Deog-Hwan
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.5
    • /
    • pp.578-586
    • /
    • 2009
  • This study was conducted to determine the effects of alkaline electrolyzed water (AIEW), acidic electrolyzed water (AcEW), 1% citric acid, and 100 ppm sodium hypochlorite, either alone or in combination with citric acid, in reducing the populations of spoilage bacteria and foodborne pathogens (Listeria monocytogenes and Escherichia coli O157:H7) on lettuce at various exposure times (3, 5, and 10 min) with different dipping temperatures (1, 20, 40, and $50^{\circ}C$). In addition, the inhibitory effect of alkaline electrolyzed water combined with citric acid on the browning reaction during storage at $4^{\circ}C$ for 15 days was investigated. Compared to the untreated control, electrolyzed water more effectively reduced the number of total bacteria, mold, and yeast than 100 ppm sodium hypochlorite under the same treatment conditions. All treatments exposed for 5 min significantly reduced the numbers of total bacteria, yeast, and mold on head lettuce. The inactivation effect of each treatment on head lettuce was enhanced as the dipping temperature increased from 1 to $50^{\circ}C$, but there was no significantly difference at temperatures greater than $40^{\circ}C$ (p<0.05). The total counts of yeast and mold in head lettuce were completely eliminated when a combination of 1% citric acid and AlEW treatment was used at temperatures greater than $40^{\circ}C$. However, decreased reduction in L. monocytogenes (2.81 log CFU/g), and E. coli O157:H7 (2.93 log CFU/g) on head lettuce was observed under these treatment conditions. In addition, enhanced anti-browning effect was observed when the samples were subjected to both 1% citric acid and AlEW treatment at temperatures greater than $40^{\circ}C$ compared to when single treatments alone were used. Thus, this combined treatment might be considered a potentially beneficial sanitizing method for improving the quality and safety of head lettuce.

Study on Reduction of Microbial Contamination on Daruma by Combination Treatment of Strong Acidic Hypochlorous Water and Ultrasonic Waves (강산성차아염소산수와 초음파를 병용처리한 조미오징어 반가공품의 미생물 오염도 저감화에 관한 연구)

  • Chung, Won-Hee;Ko, Jun-Soo;Shin, Il-Shik
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.2
    • /
    • pp.166-172
    • /
    • 2015
  • This study was performed to develop treatment method for reducing microbial contamination on Daruma (a semi-processed product of seasoned and dried squid) by combination of strong acidic hypochlorous water (SAHW) and ultrasonic waves (UW). The available chlorine concentration, oxidation reduction potential (ORP) and pH of SAHW were $69.67{\pm}0.58ppm$, $1071.33{\pm}4.16mV$ and 2.79, respectively. The 1.49 log CFU/g of viable cell count and 1.32 log CFU/g of Staphylococcus aureus was reduced, and Escherichia coli was reduced below detection limit when the Daruma was treated with 20 times (w/v) of sodium hypochlorite solution (SHS) for 120 min. The 3.62 log CFU/g of viable cell count and 3.22 log CFU/g of Staphylococcus aureus was reduced, and Escherichia coli was reduced below detection limit when the Daruma was treated with 20 times (w/v) of SAHW for 120 min. The antibacterial effects of SAHW were stronger than those of SHS at same available chroline concentration. SAHW treatment after washing strongly alkalic electrolyzed water (SAEW) showed better bactericidal effects than SAHW treatment only. The 4.0 log CFU/g of viable cell count was reduced, S. aureus was reduced below regulation limit (Log 2.0 CFU/g), and E. coli was reduced below detection limit when the Daruma was treated with 20 times (w/v) of SAHW for 90 min after washing with 20 times (w/v) of SAEW for 60 min. The viable cell number was reduced below detection limit and S. aureus was reduced below regulation limit when the Daruma was treated with 20 times (w/v) of SAHW for 60 min in ultrasonic washer. E. coli was reduced below detection limit when the Daruma was treated with 20 times (w/v) of SAHW for 10 min in ultrasonic washer. These results suggest that combination of SAHW and UW may be a good technique to reduce the microbial contamination in daruma.

THE COMPARISON OF DIFFERENT CANAL IRRIGATION METHODS TO PREVENT REACTION PRECIPITATE BETWEEN SODIUM HYPOCHLORITE AND CHLORHEXIDINE (차아염소산나트륨과 클로르헥시딘의 반응침전물 형성방지를 위한 여러 가지 근관세척 방법의 비교)

  • Choi, Moon-Sun;Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.2
    • /
    • pp.80-87
    • /
    • 2010
  • The purpose of this study was to compare the different canal irrigation methods to prevent the formation of precipitate between sodium hypochlorite (NaOCl) and chlorhexidine (CHX). Extracted 50 human single-rooted teeth were used. The root canals were instrumented using NiTi rotary file (Profile .04/#40) with 2.5% NaOCl and 17% EDTA as irrigants. Teeth were randomly divided into four experimental groups and one control group as follows; Control group: 2.5% NaOCl only, Group 1: 2.5% NaOCl + 2% CHX, Group 2: 2.5% NaOCl + paper points + 2% CHX, Group 3: 2.5% NaOCl + preparation with one large sized-file + 2% CHX, Group 4: 2.5% NaOCl +95% alcohol+ 2% CHX. The teeth were split in bucco-lingual aspect and the specimens were observed using Field Emission Scanning Electron Microscope. The percentages of remaining debris and patent dentinal tubules were determined. Statistical analysis was performed with one-way analysis of variance (ANOVA). Energy Dispersive x-ray Spectroscopy was used for analyzing the occluded materials in dentinal tubule for elementary analysis. There were no significant differences in percentage of remaining debris and patent tubules between all experimental groups at all levels (p > .05). In elementary analysis, the most occluded materials in dentinal tubule were dentin debris. NaOCl/CHX precipitate was detected in one tooth specimen of Group 1. In conclusion, there were no significant precipitate on root canal, but suspected material was detected on Group 1. The irrigation system used in this study could be prevent the precipitate formation.

Cleaning Methods to Effectively Remove Peanut Allergens from Food Facilities or Utensil Surfaces (식품 시설 또는 조리도구 표면에서 땅콩 알레르겐을 효과적으로 제거하는 세척 방법)

  • Sol-A Kim;Jeong-Eun Lee;Jaemin Shin;Won-Bo Shim
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.4
    • /
    • pp.228-235
    • /
    • 2023
  • Peanut is a well-known food allergen that causes adverse reactions ranging from mild urticaria to life-threatening anaphylaxis. Consumers suffering from peanut allergies should thus avoid consuming undeclared peanuts in processed foods. Therefore, effective cleaning methods are needed to remove food allergens from manufacturing facilities. To address this, wet cleaning methods with washing water at different temperatures, abstergents (peracetic acid, sodium bicarbonate, dilute sodium hypochlorite, detergent), and cleaning tools (brush, sponge, paper towel, and cotton) were investigated to remove peanuts from materials used in food manufacture, including plastics, wood, glass, and stainless steel. Peanut butter was coated on the surface of the glass, wood, stainless steel, and plastic for 30 min and cleaned using wet cleaning. The peanut residue on the cleaned surfaces was swabbed and determined using an optimized enzyme-linked immunosorbent assay (ELISA). Cleaning using a brush and hot water above 50℃ showed an effective reduction of peanut residue from the surface. However, removing peanuts from wooden surfaces was complicated. These results provide information for selecting appropriate materials in food manufacturing facilities and cleaning methods to remove food allergens. Additionally, the cleaning methods developed in this study can be applied to further research on removing other food allergens.

Economic Evaluations for the Carbon Dioxide-involved Production of High-value Chemicals (이산화탄소를 활용한 고부가화합물 제조기술의 경제성 평가연구)

  • Lee, Ji Hyun;Lee, Dong Woog;Gyu, Jang Se;Kwak, No-Sang;Lee, In Young;Jang, Kyung Ryoung;Choi, Jong Shin;Shim, Jae-Goo
    • Korean Chemical Engineering Research
    • /
    • v.52 no.3
    • /
    • pp.347-354
    • /
    • 2014
  • Economic evaluation of the manufacturing technology of high-value chemicals through the carbonation reaction of carbon dioxide contained in the flue gas was performed, and analysis of the IRR (Internal Rate of Return) and whole profit along the production plan of the final product was conducted. Through a carbonation reaction with sodium hydroxide that is generated from electrolysis and by using carbon dioxide in the combustion gas that is generated in the power plant, it is possible to get a high value products such as sodium bicarbonate compound and also to reduce the carbon dioxide emission simultaneously. The IRR (Internal Rate of Return) and NPV (Net Present Value) methods were used for the economic evaluation of the process which could handle carbon dioxide of 100 tons per day in the period of the 20 years of plant operation. The results of economic evaluation showed that the IRR of baseline case of technology was 67.2% and the profit that obtained during the whole operation period (20 years) was 346,922 million won based on NPV value. When considering ETS due to the emissions trading enforcement that will be activated in 2015, the NPV was improved to a 6,000 million won. Based on this results, it could be concluded that this $CO_2$ carbonation technology is an cost-effective technology option for the reduction of greenhouse gas.

Efficacy of Electrolyzed Water and Aqueous Chlorine Dioxide for Reducing Pathogenic Microorganism on Chinese Cabbage (전기분해수 및 이산화염소수 처리에 따른 배추의 미생물 제어 효과)

  • Park, Seong-Soon;Sung, Jung-Min;Jeong, Jin-Woong;Park, Kee-Jai;Lim, Jeong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.2
    • /
    • pp.240-246
    • /
    • 2012
  • This study evaluated the efficacy of strong acidic electrolyzed water (SAcEW), low alkaline electrolyzed water (LAlEW) and aqueous chlorine dioxide (ACD) for reducing pathogenic bacteria($Escherichia$ $coli$, $Bacillus$ $cereus$, $Salmonella$ Typhimurium, $Stapylococcus$ $aureus$) on Chinese cabbage. Artificially inoculated Chinese cabbage was immersed for 1, 5 and 10 min with TW, NaClO, EW and ACD. Generally, leaves showed more effective reduction than stems. Regarding the inhibitory effect, ACD treatment showed the highest effects rather than other treatments. When Chinese cabbage was immersed for 3 min in sterilized water, it was reduced to a minimum of 1.33 log CFU/g at LAlEW and a maximum of 4.70 log CFU/g at ACD. Compared to NaClO, ACD and LAlEW which showed a reduction of 3.2 log CFU/g ($Sal.$ Typhimurium) and 2.7 log CFU/g($B.$ $cereus$), respectively. Furthermore, the others had similar inhibitory effects compared to NaClO.

A Comparison on the Identification of Landslide Hazard using Geomorphological Characteristics (지형특성을 활용한 산사태 위험도 판단을 위한 비교)

  • Cha, Areum
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.6
    • /
    • pp.67-73
    • /
    • 2014
  • Landslide disasters including debris flows are the one of the most frequent natural disasters in Korea, and losses of lives and property damages due to these catastrophic events have been increased every year. Various mitigation programs and related policies have been conducted in order to respond and prepare landslide disasters. Most landslide reduction programs are, however, focused on recovery actions after the disasters and lead to unrealistic consequences to the affected people and their properties. The main objective of this study, therefore, is to evaluate the landslide hazard based on the identification of geomorphological features, which is for the preparedness of the landslide disasters. Two methodologies, SINMAP and vector dispersion analyses are used to simulate those characteristics where landslides are actually located. Results showed that both methods well discriminate geomorphic features between stable and unstable domains. This proves that geomorphological characteristics well describe a relationship with the existing landslide hazard. SINMAP analysis which is based on the consecutive model considering external factors like infiltration is well identify the landslide hazard especially for debris flow type landslides rather than vector dispersion focusing on a specific area. Combining with other methods focusing specific characteristics of geomorphological feature, accurate landslide hazard assessments are implemented.