• Title/Summary/Keyword: 복합재료 바닥판

Search Result 27, Processing Time 0.022 seconds

Flexural Strength of Composite HSB Hybrid Girders in Positive Moment (HSB 강재 적용 강합성 복합단면 거더 정모멘트부의 휨저항강도)

  • Cho, Eun-Young;Shin, Dong-Ku
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.3
    • /
    • pp.385-395
    • /
    • 2011
  • The flexural strength of composite HSB hybrid I-girders under positive moment is investigated by the moment-curvature analysis method to evaluate the applicability of the current AASHTO LRFD design specification to such girders. The hybrid girders are assumed to have the top flange and the web fabricated from HSB600 steel and the bottom flange made of HSB800 steel. More than 6,200-composite I-girder sections that satisfy the section proportion limits of AASHTOL RFD specifications are generatedby the random sampling technique to consider a statistically meaningful wide range of section properties. The flexural capacities of the sections are calculated by the nonlinear moment-curvature analysis in which the HSB600 and HSB800 steels are modeled as an elastoplastic, strain-hardening material and the concrete as CEB-FIP model. The effects of ductility ratio and compressive strength of concrete slab on the flexural strength of composite hybrid girders make of HSB steels are analyzed. Numerical results indicated that the current AASHTO-LRFD equation can be used to calculate the flexural strength of composite hybrid girders fabricated from HSB steel.

Service and Ultimate Load Behavior of Bridge Deck Reinforced with GFRP Rebars (GFRP 보강근으로 보강된 교량 바닥판의 성능과 사용성에 관한 실험연구)

  • Yu, Young Jun;Park, Young Hwan;Park, Ji Sun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5A
    • /
    • pp.719-727
    • /
    • 2008
  • The tensile and bond performance of GFRP rebar are different from those of conventional steel reinforcement. It requires some studies on concrete members reinforced with GFRP reinforcing bars to apply it to concrete structures. GFRP has some advantages such as high specific strength, low weight, non-corrosive nature, and disadvantage of larger deflection due to the lower modulus of elasticity than that of steel. Bridge deck is a preferred structure to apply FRP rebars due to the increase of flexural capacity by arching action. This paper focuses on the behavior of concrete bridge deck reinforced with newly developed GFRP rebars. A total of three real size bridge deck specimens were made and tested. Main variables are the type of reinforcing bar and reinforcement ratio. Static test was performed with the load of DB-24 level until failure. Test results were compared and analyzed with ultimate load, deflection behavior, crack pattern and width.

Flexural Behavior of Bridge Deck Concrete Reinforced with FRP Box and Plate (FRP Box와 판으로 보강된 교량 바닥판 콘크리트의 휨거동)

  • Nam J. H.;Jeong S. K.;Yoon S. J.;Kim B. S.;Cho K. H.
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.04a
    • /
    • pp.13-17
    • /
    • 2004
  • In recent years, the deterioration of reinforced concrete structures has become a serious problem in civil engineering fields. This situation is mainly due to corrosion of steel reinforcing bars embedded in concrete. Recently, there has been a greatly increased demand for the use of FRP (fiber reinforced plastic) in civil engineering field due to their superior mechanical and physical properties. This paper presents an experimental study on the behavior of concrete bridge deck reinforced with FRP Box, FRP Plate, and FRP Re-bar. In tlIe study, mechanical properties of FRP Box, FRP Plate, GFRP Re-bar, and CFRP Grid have been investigated. Full scale one-way deck slab was tested under four point lateral load (equivalent to actual wheel load of DB-24 including impact). Load-deflection and load-strain data were collected through LVDT's and strain gages attached to the specimen.

  • PDF

An Experimental Study of Fatigue and Static Behavior for Composite Deck Member (복합재료 바닥판 부재의 정적 및 피로거동에 관한 실험적 연구)

  • Kim, Young-Chan;Park, Tai-Young;Kim, Doo-Hwan
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.479-482
    • /
    • 2007
  • For making an application in construction parts of the composite material's complicated theory needs to accumulation of data by the help of study and experiment(demonstrate). Thus, this study is conducted research and analysis about the Influence of repeated loading cycles on Strength Ratio of the high quality material which is Carbon/Epoxy Composite Laminates through the test of tensile and fatigue Characteristics, based on it, construction engineers will can apply composite materials to construction technical without difficulty.

  • PDF

Flexural Characteristics of Composite Deck Model Fabricated with VARTM (진공성형제작 복합소재 바닥판 모델의 휨특성분석)

  • 이성우;주성애
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.05a
    • /
    • pp.130-133
    • /
    • 2001
  • Recent days composite bridge deck is gaining attraction due to many advantages such as light weight, high strength, corrosion resistance, and high durability. In this study, composite sandwich deck models of hat, box, and triangular section type were fabricated by VARTM process. For those models, three point flexural test was carried out both in strong and weak axis. The experimental results are compared with each other to determine efficient section type. Also finite element analysis was performed to verify analysis model. It is demonstrated that the results of numerical analysis agree well with experimental results.

  • PDF

Development of Composite Pedestrian Bridge Deck and Its Snap-fit Connection (착탈결구식 복합소재 바닥판의 연결부 거동분석)

  • Lee, Sung-Woo;Jeong, Gyu-Sang
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.11a
    • /
    • pp.280-284
    • /
    • 2005
  • Existing construction materials such as concrete and steel have chronic problems; deterioration and corrosion. Owing to its special features of light weight ‘ high durability, anti-corrosion, composite material used in civil infrastructure can not only solve fundamental problems of deterioration and corrosion, but also reduce both construction and maintenance cost significantly. After the fabrication of deck panel with snap-fit connection by pultrusion through composite design according to stacking sequence of composite laminates and structural analysis, performance of decks will be verified and evaluated by structural tests.

  • PDF

Experimental Investigations on the Flexural Behavior of One-Way Concrete Slabs Reinforced with GFRP Re-Bar Bundle (유리섬유 보강 플래스틱 Re-Bar 다발로 보강된 1방향 콘크리트 슬래브의 휨거동에 관한 실험적 연구)

  • 윤순종;김병석;유성근;정재호;정상균
    • Composites Research
    • /
    • v.16 no.3
    • /
    • pp.32-40
    • /
    • 2003
  • In recent years, the investigation on the development of fiber reinforced plastic(FRP) Re-Bar has been greatly increased due to the attractive physical and mechanical properties of FRP. The primary reason of such a tendency is in the fact that it does not ordinarily cause durability problems such as those associated with steel reinforcement corrosion. This study is an experimental investigation on the flexural behavior of one-way concrete slabs, which can be used to construct bridge deck, reinforced with GFRP Re-Bar bundle. The tensile tests of GFRP Re-Bar produced by domestic industry and third point bending tests of one-way slab specimens reinforced with GFRP Re-Bar bundle are peformed. For all slab specimens, load-deflection relations are predicted by using the ACI committee 440 and the results are compared with experimental ones. In order to establish the design criteria or guidelines of concrete flexural member reinforced with FRP Re-Bar, it is needed to evaluate the serviceability limit state as well as the strength limit state.

Application of GFRP Re-bar in Concrete Bridge Deck Construction (교량 바닥판 콘크리트의 시공을 위한 GFRP근의 활용)

  • 김지홍;주형중;김병석;윤순종
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.04a
    • /
    • pp.152-156
    • /
    • 2003
  • In this paper, we present the results of an experimental research on the load-deflection characteristics of full-scale concrete bridge decks reinforced with GFRP re-bars. Similar researches have been conducted in many countries to extend the service life of concrete bridge decks, which are under harsh environmental condition. Concrete bridge decks are one of the major concerns for the maintenance of bridges. GFRP re-bar available in the domestic construction market was investigated and the concrete deck reinforced with GFRP re-bars was tested under flexure to investigate the applicability of GFRP re-bar on the bridge deck construction.

  • PDF

Interface Horizontal Shear Strength between UHPC Deck and Concrete Girder with Stirrups (스터럽을 이용한 UHPC 바닥판과 콘크리트 거더 연결부의 수평전단강도)

  • Yoo, Dong-Min;Hwang, Hoon-Hee;Kim, Sung-Tae;Park, Sung-Yong
    • Composites Research
    • /
    • v.25 no.5
    • /
    • pp.164-168
    • /
    • 2012
  • The purpose of this experimental research was to evaluate interface shear requirements between UHPC deck and concrete girder with stirrups according to Korean Highway Bridge Design Code and AASHTO LRFD Bridge Design Specifications. The push-out tests are performed to analize the composite behavior in interface of connection. The test results were compared to the values of interface horizontal shear strength predicted by current codes. As the results, it was observed that the test results provided more conservative estimate for horizontal shear strength than the values by current codes equation.

The Minimum Lap-spliced Length of the Reinforcement in the Steam Curing UHPC Bridge Deck Slab Joint (UHPC 바닥판 증기양생 현장이음부의 최소철근겹침이음길이)

  • Hwang, Hoon-Hee;Park, Sung-Yong
    • Composites Research
    • /
    • v.26 no.2
    • /
    • pp.135-140
    • /
    • 2013
  • The static test was performed to verify the effect of the joint in the UHPC bridge deck slab and the minimum lap-spliced length was presented. A total of six test members was fabricated to estimate the static behavior of the steam curing UHPC bridge deck slab joint by the four points bending test method. The lap-spliced joint type was expected to be not only simple but also efficient in UHPC structure because of the high bond stress of UHPC. Test results show that the decrease of maximum flexural strength was about 30% and the minimum lap-spliced length which behaved similar to the continued reinforcement in strength and ductility was 150 mm.