• Title/Summary/Keyword: 보조펌프

Search Result 77, Processing Time 0.026 seconds

Study on Electrically Powered Left Ventricular Circulation Assist Device (좌심실 전동순환 보조장치에 관한 연구)

  • Kim, Myoung-Nam;Lee, Jeong-Woo;Chang, Bong-Hyun;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.51-60
    • /
    • 2000
  • This paper outlines the development of a non-pulsatile axial flow type blood pump control system. By utilizing blood pressure and heart rate, this system can assist the left ventricle in controlling blood pressure and blood volume. The system is comprised of a blood pump, signal sensor, signal interface, and signal-processing component. A control algorithm is also proposed which can control non-pulsatile, continuous blood flow in the human circulatory system. To facilitate the control required for non-pulsatile blood pump in a physiological system, an experimental control rule was developed utilizing ECG and blood pressure data, both of which are easily detectable variables in the body. The system was then tested using a mock-up circulation system and we found that it is possible that this systems could be temporarily used in clinic.

  • PDF

Performance Analysis of Cooling Tower-Assisted Hybrid Ground-Coupled Heat Pump (HGCHP) System (냉각탑 병용 하이브리드 지열 히트펌프 시스템의 성능 분석)

  • Sohn, Byonghu;Lee, Doo-Young;Choi, Jae-Ho;Min, Kyong-Chon
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.1
    • /
    • pp.19-26
    • /
    • 2016
  • This paper presents the measurement and analysis results for the performance of HGCHP system using a cooling tower as a supplemental heat rejector. In order to demonstrate the performance of the hybrid approach, we installed the monitoring equipments including sensors for measuring temperature and power consumption, and measured operation parameters from February 1, 2014 to February 28, 2015. Leaving load temperatures to building showed an average value of $11.7^{\circ}C$ for cooling and $39.5^{\circ}C$ for heating, respectively. From the analysis, the daily PF of hybrid GCHP system varied from 2.6 to 6.6 over the measurement period.

Loop Filter Voltage Variation Compensated PLL with Charge Pump (전하펌프를 이용한 루프 필터 전압변화 보상 위상고정루프)

  • An, Seong-Jin;Choi, Yong-shig
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.10
    • /
    • pp.1935-1940
    • /
    • 2016
  • This paper proposes a phase-locked loop (PLL) to minimize the loop filter output voltage fluctuation by using a comparator including RC time constant circuits. The voltage variation of loop filter is inputted to RC time constant circuits which have two RC time constants, large and small. While a small RC time constant circuit quickly conveys the output voltage variation of loop filter, a large RC time constant circuit conveys slowly the output voltage variation of loop filter and its output looks like constant voltage. The output signal of the comparator controls the sub charge pump and reduces the input voltage variation of voltage-controlled oscillator (VCO). Therefore, the proposed PLL generates a phase noise reduced signal. It has been designed with a 1.8V supply voltage, 0.18um multi - metal and multi - poly layer CMOS process and proved by Hspice simulation.

Study for High Efficiency Heat Pump System Commercialization with Air Heat Source (고효율 공기열원 히트펌프시스템 실용화 연구)

  • Han, Jang-Min;Kim, Young-Taek
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.405-408
    • /
    • 2009
  • 공기열원 히트펌프시스템의 문제점, 즉 열효율, 안정성, 착상에 대한 현황을 파악하고 이를 해결하기 위한 연구를 수행하였다. 열효율과 안정성을 위해 기존 시스템을 보완한 8행정 냉매사이클시스템 개발과 제어시스템의 개발을 통해 히트펌프 시스템의 효율을 2배 정도 증가시키고, 안정성을 높이며, 착상 문제를 최소화할 수 있도록 하였다. 개발된 공기열원 히트펌프시스템의 COP는 평균 5정도이고, 안정적으로 운용되는 외부 온도는 $-10^{\circ}C$에서 $55^{\circ}C$까지이다. 토출되는 온수의 온도는 $50{\sim}60^{\circ}C$정도이다. 평균 제상시간은 1분 이내이다. 앞으로 개발해야 할 문제는 외부 온도 $-10^{\circ}C$ 이하지역에서 보조열원 없이 난방을 할 수 있고 친환경 냉매를 사용하며 COP가 7이상인 고효율 히트펌프시스템를 실용화하는 것이다.

  • PDF

Effect of a Booster Inducer on the Suction Performance of Turbopumps (보조 인듀서가 터보펌프의 흡입성능에 미치는 영향)

  • Choi, Chang-Ho;Hong, Soon-Sam;Kim, Jin-Han
    • The KSFM Journal of Fluid Machinery
    • /
    • v.8 no.3 s.30
    • /
    • pp.42-47
    • /
    • 2005
  • Effects of a booster inducer on the suction performance of turbopumps are investigated in this paper. To see the effect of the booster inducer, suction performance tests are conducted with and without the booster inducer for three turbopumps. It is shown that the booster inducer can enhance the suction performance of turbopumps when the tip clearance of the main inducers are relatively large. Numerical analysis are also carried out to see the effects of the booster inducer on the performance of the main inducer. The booster inducer is shown to increase the static pressure at the inlet of the main inducer and prevent growing of inlet back flows which are believed to have deleterious effects on the suction performance of the inducer.

Effect of a booster inducer on the suction performance of turbopumps (보조 인듀서가 터보펌프의 흡입성능에 미치는 영향)

  • Choi, Chang-Ho;Hong, Soon-Sam;Kim, Jinhan
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.552-557
    • /
    • 2004
  • Effects of a booster inducer on the suction performance of turbopumps are investigated in this paper. To see the effect of the booster inducer, suction performance tests are conducted with and without the booster inducer for three turbopumps. It is shown that the booster inducer can enhance the suction performance of turbopumps when the tip clearance of the main inducers are relatively large. Numerical analysis are also carried out to see the effects of the booster inducer on the performance of the main inducer. The booster inducer is shown to increase the static pressure at the inlet of the main inducer and prevent growing of inlet back flows which are believed to have deleterious effects on the suction performance of the inducer.

  • PDF

CCDP Evaluation of the Eire Areas in NPP Applying CEAST Model (II) (화재모델 CFAST를 이용한 원전 화재구역의 CCDP평가(II))

  • Lee Yoon-Hwan;Yang Joon-Eon;Kim Jong-Hoon;Kim Woon-Byung
    • Fire Science and Engineering
    • /
    • v.19 no.3 s.59
    • /
    • pp.20-27
    • /
    • 2005
  • This paper evaluates the fire safety level of eight pump rooms in the nuclear power plant using a fire model, CFAST We estimate the Conditional Core Damage Probability (CCDP) of each room based on the analyzed results of CFAST Eight rooms located on the primary auxiliary building of the nuclear power plant are high pressure safety injection pump room A/B, low pressure safety injection pump room Am. containment sprdy pump room A/B, and motor-driven auxiliary feed water pump room A/B. The upper layer gas temperature of each room is estimated and the integrity of cable is reviewed. Based on the results, the integrity of the cable located at the upper part of compartment is maintained without thermal damage. The Conditional Core Damage Probability Is reduced to half of the old values. Accordingly, the fire safety assessment for eight pump rooms using the fire model will be capable of reducing the uncertainty and to develop a more realistic model.

A Study on Efficient Capacity Control of a Marine Pump with the Variation of Sea Water Temperature (선박용 펌프의 해수온도 변화에 따른 효율적인 유량제어에 관한 연구)

  • Choi, Sang-Bom;Im, Myeong-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.6
    • /
    • pp.788-793
    • /
    • 2014
  • In this study, the electrical power consumption saving effect is studied through installing an inverter which is able to control the R.P.M. of marine sea water pump by effective flow control. The study looks at how sea water pump's flow control influences on the system without the Marine Growths Protection System(MGPS). Auxiliary sea water pump and refrigerator sea water pump in training ships, which are always operated not only in harbor but also in navigation, was used in the experiment and the experiment was conducted by dividing into harbor and navigation. As a result of research, in the case the sea water temperature is under $18^{\circ}C$, the operation was possible with a 58.3 % decrease in pump R.P.M. and electric power consumption was saved by 50 %. In spite of the sea water temperature increasing upto $34^{\circ}C$, pump R.P.M. at 91.6 % was sufficient to operate with a 20 % electric power consumption saving effect. In the pipelines without MGPS, lowering R.P.M. along with lowering pressure results in the attachment of various marine growths.

Simulation of Design Factor Effects on Performance of Vacuum System (진공시스템 성능에 대한 설계인자 영향 전산모사)

  • Kim, Hyung-Taek;Jeong, Kwang-Pil
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.6
    • /
    • pp.405-413
    • /
    • 2007
  • Effect of design factors on the performance of vacuum system was simulated for optimum design of system. In this investigation, the feasibility of modelling mechanism for $VacSim^{Multi}$ simulator was proposed. Simulation results of pumping design factor showed the possibilities of simulation fore-study for the detailed design factors. Simulation of roughing pump presented the expected pumping behaviors based on the specifications of commercial pump. Application of booster pump exhibited the high pumping efficiency for middle vacuum range. Combinations of optimum backing pump for diffusion and turbo vacuum system were obtained. And, the characteristics of process application of both systems were also acquired.