• Title/Summary/Keyword: 보상전압

Search Result 899, Processing Time 0.028 seconds

A New AMOLED Pixel Circuit Compensating for Threshold Voltage Shift of OTFT (유기 박막 트랜지스터의 문턱전압 변화를 보상하기 위한 새로운 구조의 AMOLED 화소 회로에 관한 연구)

  • Choi, Jong-Chan;Shin, A-Ram;Lee, Jae-In;Yoon, Bong-No;Sung, Man-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.95-96
    • /
    • 2008
  • A new voltage-driven pixel circuit using soluble-processed organic thin film transistors (OTFTs) for an active matrix organic light emitting diode (AMOLED) is proposed. The proposed circuit is composed of four switching TFTs, one driving TFT and one storage capacitor. The proposed circuit can compensate for the degradation of OLED current caused by the threshold voltage shift of the OTFT. The simulation results show that the variation of OLED current corresponding to a 3V threshold voltage shift is decreased by 30% compared to the conventional 2TlC structure.

  • PDF

Design and testing of bipolar pulsed power supply with high efficiency for mineral exploration (광물 탐사를 위한 고효율 양극성 펄스전원장치 설계 및 실험)

  • Bae, Jung-Soo;Kim, Shin;Yu, Chan-Hun;Kim, Hyoung-Suk;Kim, Jong-Soo;Jang, Sung-Roc
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.48-50
    • /
    • 2018
  • 본 논문은 광물 탐사용 25kW 양극성 펄스전원장치에 대해 기술한다. 고효율 LCC 공진형 컨버터와 풀 브리지 기반 바이폴라 펄스 스위칭부로 구성된 500V, 12.5A 단위 모듈을 설계한다. LCC 공진형 컨버터는 도전 손실을 줄이기 위해 사다리꼴 모양의 공진 전류를 갖도록 하고, 높은 전력 밀도를 달성하기 위해 변압기의 누설 인덕턴스를 공진 인덕턴스로 활용한다. 또한, 반복적인 짧은 펄스 기반으로 설계된 게이트 구동 회로는 DC에서 8kHz의 주파수 범위를 동작시키고 게이트 변압기의 사이즈를 줄이기 위해 제안된다. 개발된 양극성 펄스전원장치는 4개의 모듈이 직병렬로 결선되어 부하 조건에 따라 Grounded dipole mode (2kV, 12.5A) 또는 Loop mode (500V, 50A)로 동작한다. 네 모듈의 출력 전압 밸런싱을 충족시키기 위해 LCC 공진형 컨버터의 변압기에 보상권선이 감긴다. 본 논문에서는 양극성 펄스전원 장치의 상세설계에 대해 기술하고, 시뮬레이션 및 실험 결과를 통해 이를 검증한다.

  • PDF

A Study on Current Harmonics Reduction and Unbalanced Source Voltage Compensation Using Series Active Power Filter and Parallel Passive Filter (직렬 능동전력필터와 병렬 수동필터를 이용한 고조파 전류 저감 및 불평형 전원 전압 보상에 관한 연구)

  • Oh, Jae-Hoon;Ko, Su-Hyun;Han, Yoon-Seok;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.196-199
    • /
    • 2001
  • This paper deals with current harmonics and unbalanced source voltages compensation using combined filter system. Filter system consists of a series active filter and parallel passive filters. Passive filters were a traditional method to compensate current harmonics, so those were installed in power system widely. The active filter can be a substitution to improve filtering characteristics and complement drawbacks of the passive filter. The combined system of the active power filter and passive filter can has a better compensation performances and economical goods. The series type active power filter injects compensation voltage into power system by transformers. It's compensation principle is able to applicate for voltage compensation. A new control algorithm for series active filter to compensate current harmonics and unbalanced source voltages is proposed. In the proposed algorithm, a compensation voltage for harmonic reduction is calculated directly by instantaneous reactive power theory, and a compensation voltage for unbalanced source voltage is calculated in based on a synchronous reference frame. By experiments, we show validity of proposed compensation method.

  • PDF

Active and Reactive Power Control of the Battery Energy Storage System interconnected with Power Distribution System (배전계통에 연계된 전지전력저장시스템의 유.무효전력 제어)

  • 김재철;문선호;최준호;김응상
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.127-133
    • /
    • 1999
  • Ths paper deals with the active and reactive power control of Battery Energy Storage System (BESS) during its interconnection operation to power distribution system When an interconnection operation of BESS to power distribution system, it is well suited for peak load shaving and distribution voltage compensation by controlling the real and reactive power. Equivalent mxiel of the distribution system and the BESS is derived and power flow equations are presented to control the real and reactive power of BESS. In this paper, to control the active and reactive power of BESS, $P-\delta$ and Q-V control method and ntJIrerical description is presented. To verify the proposed control method, using PSCAD/EMTDC program simulates the active and reactive power control of BESS.f BESS.

  • PDF

A 0.13-μm CMOS RF Front-End Transmitter For LTE-Advanced Systems (LTE-Advanced 표준을 지원하는 0.13-μm CMOS RF Front-end transmitter 설계)

  • Kim, Jong-Myeong;Kim, Chang-Wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.5
    • /
    • pp.1009-1014
    • /
    • 2012
  • This paper has proposed a 2,500 MHz ~ 2,570 MHz 0.13-${\mu}m$ CMOS RF front-end transmitter for LTE-Advanced systems. The proposed RF front-end transmitter is composed of a quadrature up-conversion mixer and a driver amplifier. The measurement results show the maximum output power level is +6 dBm and the suppression ratio for the image sideband and LO leakage are better than -40 dBc respectively. The fabricated chip consumes 36 mA from a 1.2 V supply voltage.

Performance Improvement of Reduced Order Extended Luenberger Observer(ROELO) based Sensorless Vector Control Fed by Matrix Converter With Non-linearity Modeling (비선형모델을 이용한 matrix convertor로 구동되는 축소차원 확장 루엔버거 관측기기반의 유도전동기 센서리스 벡터제어의 성능개선)

  • Lee Kyo-Beum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.4
    • /
    • pp.363-372
    • /
    • 2005
  • This paper presents an improved sensorless vector control system for high performance induction motor drives fed by a matrix converter with non-linearity compensation. The nonlinear voltage distortion that is caused by commutation delay and on-state voltage drop in switching devices is corrected by a new matrix converter model. A Reduced Order Extended Luenberger Observer (ROELO) is employed to bring better response in the whole speed operation range and a method to select the observer gain is presented. Experimental results are shown to illustrate the performance of the proposed system.

Maximum Modulation Index of VSC HVDC based on MMC Considering Compensation Signals and AC Network Conditions (전력계통 전압 변동과 순환 전류 보상 성분을 고려한 MMC 기반 VSC-HVDC의 최대 변조 지수 선정에 관한 연구)

  • Kim, Chan-Ki;Belayneh, Negesse Belete;Park, Chang-Hwan;Kim, Jang-Mok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.1
    • /
    • pp.61-67
    • /
    • 2020
  • This study deals with the modulation index (MI) of a voltage source converter (VSC) HVDC system based on a modular multilevel converter (MMC). In the two-level converter, the purpose of the MI is to maximize the achievable AC voltage of the converter from a fixed DC voltage. Unlike that in a two-level converter, the MI in the MMC topology plays a role in making the converter a voltage source using a capacitor. The circulating current in the MMC distorts the AC voltage reference, and the distortion affects the MI. In addition, the AC network conditions, such as AC voltage variation and reactive power, affect the MI. Therefore, the MI should be optimized with consideration of internal and external factors. This study proposes a method to optimize the MI of an MMC HVDC system.

A study on the compensation of misfiring by the method of ramp address voltage in AC PDP (AC PDP의 경사형 Address 전압 인가 방식에 의한 오방전 보상에 관한 연구)

  • Kim, J.Y.;Lee, S.J.;Kwon, B.D.;Kim, D.H.;Lee, H.J.;Park, J.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.149-152
    • /
    • 2002
  • If the ambient temperature rises for AC PDP, some of the discharge cells are turned off because of the misfiring during address period. Particularly, the misfiring of the 'last scan line is more serious than that of the first. In order to compensate the misfiring in such that case, different addressing voltage is applied at each cell such as progressively increasing pulse voltage instead of constant one. As a result, the addressing time and discharge charge of the last scan line have become similar to those of the first scan line and the phenomenon of misfiring has disappeared.

  • PDF

Analysis on Current Limiting and Voltage Sag Compensating Characteristics of a SFCL using Magnetic Coupling of Parallel Connected Two Coils (병렬연결된 두 코일의 자기결합을 이용한 초전도 전류제한기의 전류제한 및 전압강하 보상 특성 분석)

  • Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.2
    • /
    • pp.159-163
    • /
    • 2010
  • The superconducting fault current limiter (SFCL) plays a role in compensating the voltage sag of the sound feeder adjacent to the fault feeder as well as the fault current limiting operation of the fault feeder. Especially, the SFCL using magnetic coupling of two coils with parallel connection has different voltage sag compensating and current limiting characteristics due to the winding direction and the inductance ratio of two coils. In this paper, the current limiting and the voltage sag compensating characteristics of a SFCL using magnetic coupling of parallel connected two coils were analyzed. Through the analysis on the experimental results considering the winding direction of two coils, the SFCL designed with the additive polarity winding was shown to have the higher limited fault current than the SFCL designed with the subtractive polarity winding. In addition, it could be confirmed that the higher fault current limitation of the SFCL could be contributed to the higher load voltage sag compensation.

A PC-based instrumental system for fast measurement and analysis of power losses in DC-DC converter (DC-DC 컨버터의 고속 손실측정과 분석을 위한 PC 기반 계측시스템)

  • 안태영;주정규
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.6
    • /
    • pp.569-575
    • /
    • 2003
  • This paper present a new fully-automated PC-based instrumental system that could quickly measure and analyze the efficiency of switching power supplies for the entire operating range. In the proposed system, we applied an Indirect method for high-voltage low-current measurements and a direct method for low-voltage high-current measurements, in order to obtain a high accuracy with minimum equipment requirement. Compared to the conventional methods, the newly proposed system offers more accurate and much faster real-time assessment of the efficiency with minimum measurement error. The performance and accuracy of the proposed system are verified using a 50 W switching power supply intended for telecommunication applications.