• Title/Summary/Keyword: 보강 웨브

Search Result 42, Processing Time 0.019 seconds

A Study for an Evaluation of Flexural Strength of Plate Girders Reinforced with One Line of Longitudinal Stiffeners (수평보강재로 1단 보강된 플레이트거더의 휨강도 평가 방안 연구)

  • Kim, Byung Jun;Park, Yong Myung;Mykyta, Kovalenko;Cho, Kwang Il
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.4
    • /
    • pp.281-289
    • /
    • 2017
  • The current AASHTO LRFD and Eurocode 3 specifications have been found to underestimate the flexural strength of longitudinally reinforced plate girders. This is because the web-flange interaction is not considered appropriately when a web is reinforced. The buckling strength of compression flange increases due to the improved rotational restraint to the compression flange. Also, the compression flange and the longitudinal stiffener could constrain the web rotation, so that a certain area of the web reaches yield strength. In this study, a model for evaluating the flexural strength is proposed for plate girders reinforced with one line of longitudinal stiffeners, considering the increase of the buckling strength of the compression flange and the actual stress distribution of the web. The flexural strengths of the conventional steel(SM490) and the high-strength steel(HSB800) plate girders were evaluated from the nonlinear analysis and the applicability of the proposed model was analyzed.

The behavior of branch-rotated and chord web-stiffened T-joints in Cold-formed Square Hollow Sections (지관이 회전되고 주관 웨브 보강한 각형강관 T형 접합부의 거동에 관한 연구)

  • Park, Keum Sung;Bae, Kyu Woong;Jeong, Sang Min;Kang, SeokGyu;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.6 s.67
    • /
    • pp.673-681
    • /
    • 2003
  • This paper describes the experiment that determines the ultimate strength of new uniplanar T-joints made of cold-formed square hollow sections. The new T-joint focused on the configuration of a branch member that is oriented 45 degrees to the plane of the truss and welded to the chord member whose web is stiffened with plate. The strength and failure mode are examined using the existing strength formula for the branch-rotated T-joint $(16.7{\leq}2{\gamma}(B/T){\leq}33.3$ and $0.63{\leq}{\beta}(b1/B){\leq}0.7)$. The test result shows that the capacity of the stiffened joint increases with thicker stiffening plate. The failure mode of the specimen $(2{\gamma}=33.3)$ is stiffened with plate changes from M2 (flange failure) to M3 (combined failure). On the other hand, the failure mode of the specimen $(2{\gamma}=16.7)$ is stiffened with plate changes from M1 ( web failure) to M2 (flange failure)

Shear Strength of Plate Girder (플레이트거더의 전단내력)

  • Choi, Chui-Kyung;Kim, Kyu-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.2
    • /
    • pp.169-176
    • /
    • 2003
  • In the design of plate girder web panels, it is required to evaluate accurately the elastic buckling strength under shear, whether or not the post-buckling strength is accounted for. Currently, elastic shear buckling coefficient of web panels stiffened by transverse intermediate stiffeners are determined by assuming conservatively that web panels are simply supported at the juncture between the flange and web. Although the notion of the real boundary condition at the juncture of the web and the flanges to be somewhere between simple and fixed has been recognized from early days, the boundary condition has been conservatively assumed, mainly due to lack of means to evaluate it in a rational manner. In this paper, a series of numerical analyses and experiments is carried out to provide a simple equation with some parameters especially the flange-web thickness ratio.

Numerical Study on Required Stiffness of Longitudinal Stiffener in Plate Girders (플레이트 거더의 수평보강재 필요 강성에 관한 해석적 연구)

  • Lee, Kun Joon;Park, Yong Myung;Kim, Byeong Jun;Park, Chan Hee
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.1
    • /
    • pp.43-52
    • /
    • 2016
  • A numerical study on required stiffness of the longitudinal stiffener in the webs stiffened with flat plate at one-side of the web was conducted. The longitudinal stiffeners are commonly placed around 0.2D, i.e., 1/5 the web depth due to fabrication convenience although most plate girders for bridges are unsymmetric section. Considering asymmetry of section, aspect ratio of web and the rigidity ratio of longitudinal stiffener(${\gamma}^*$), eigenvalue analysis were performed to evaluate the buckling strength for the webs with a stiffener located at 0.16D~0.24D. Based on the parametric analysis, the required stiffness of the longitudinal stiffener to satisfy the buckling strength specified in AASHTO LRFD specifications was presented.

An Experimental Study on the Fire Resistance behaviour of Asymmetric Slimfloor Beam According to Cross Section Shape Variation (비대칭 H형강 합성보의 단면형상변화에 따른 온도특성 및 화재거동에 관한 실험적 연구)

  • Kim, Hyung-Jun;Kim, Heung-Youl;Lee, Jae-Sung;Kwon, Ki-Hyuck;Yeo, In-Hwan
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.23-30
    • /
    • 2012
  • The temperature development of a structural element is dependent on section factor, which is estimated as a ratio of the fire-exposed perimeter to the cross-section area. Hence, with the higher section factor, the faster temperature development of the section os observed. Composite beam member, partially embedded asymmetry H beam, has a good fire resistance to the cross-section. The study was intended to conduct with change with section factor. The experimental result of section type which the Slim Beam Floor is bottom flange reinforced method.

A Study on the properties of flexural behavior according to reinforcing method of Composite Beams of different types of structure (이질 구조부 보강방법에 따른 혼합구조보의 휨거동 특성에 관한 연구)

  • Lim, Byung Ho;Park, Jung Min;Kim, Wha Jung
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.4
    • /
    • pp.419-431
    • /
    • 2001
  • This study was to investigate structural behavior of composite structure beams composed of end-RC. center-Steel according to respective reinforcing method for connection zone composed of different materials (SRC) while attaching main bars on steel-flange by welding. The main reinforcing methods are as follows ; non-reinforcing, vertical shear reinforcing (type-stirrup), inclined reinforcing(type-x), horizontal reinforcing(type-web, 0.3L), double horizontal reinforcing (type-web, 0.3L), vertical reinforcing (type-flange, 0.3L). Consequently, It showed little difference in structural properties like ductility and strength according to the attaching method of main bars. For Maximizing the structural properties of composite beam, the most effective methods were vertical reinforcing one and double horizontal reinforcing one.

  • PDF

An Experimental Study for Flexural Failure Behavior of Composite Beam with Cast-in-place High Strength Concrete and GFRP Plank Using As a Permanent Formwork and Tensile Reinforcement (유리섬유강화폴리머 판을 영구거푸집 및 인장 보강재로 활용한 현장타설 고강도콘크리트 합성보의 휨 파괴거동에 관한 실험적 연구)

  • Um, Chan Hee;Yoo, Seung Woon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.1015-1024
    • /
    • 2015
  • An experiment of composite beam was performed which utilized glass fiber reinforced polymer (GFRP) plank as the permanent formwork with cast-in-place high strength concrete. This research analyzed the flexural failure behavior of composite beam by setting the sand coated at GFRP bottom surface, the perforation and interval of the GFRP plank web, and the width of the top flange as the experimental variables. As a result of the experiments for effectiveness of sand attachment in case of not perforated web, approximately 43% higher ultimate load value was obtained when the sand was coated than not coated case. For effectiveness of perforation and interval of gap, approximately 23% higher maximum load value was seen when interval of the perforation gap was 3 times and the fine aggregate was not coated, and approximately 11% higher value was observed when the perforation gap was 5 times on the coated specimen. For effectiveness of top flange breadth, the ultimate load value was approximately 12% higher in case of 20mm than 40mm width.

Evaluation of the Effective Width and Flexural Strength of the T-Stalled Walls (T형 벽체의 유효 폭 및 휨강도 평가)

  • 양지수;이리형
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.796-803
    • /
    • 2002
  • T-shaped walls have different strength, stiffness and ductility in the two opposite directions parallel to the web when subjected to horizontal in-plane loads. When the flange is in tension, the extent that the flange reinforcement contributes to the flexural strength will be subjected to shear-lag effect. Because of this shear-lag effect, the flange may not participate fully in the action with the web, and the effective flange width is needed for predicting the actual strength and stiffness of structures. The objective of this paper is to evaluate the effective flange width and actual strength of the T-shaped wall with Korean code specified detailing of the wall web. Three specimens were tested with cyclic lateral loading applied at top of the wall. A constant axial load of approximately 0.1f$\_$ck/$.$A$\_$g/ is maintained during the testing. Test results show that the effective flange width increases with increasing drift level, such that the entire overhanging flange of h/3 is effective at the maximum strength level. Therefore, the use of PCI or KBC(Korean Building Code) value of h/10 is unconservative with respect to detailing at the wall web boundary.

Experimental Study on Flexural Structural Performance of Sinusoidal Corrugated Girder (파형 웨브주름 보의 휨성능에 관한 실험적 연구)

  • Kim, Jong Sung;Chae, Il Soo
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.6
    • /
    • pp.503-511
    • /
    • 2015
  • In long span steel structure, the plate girder reinforced with stiffeners are commonly used. When choosing the cross section with deep depth of girder as well as narrow width, however, out of plane buckling can be a problem due to web slenderness. In an effort to solve this issue, current study determined the applicability of using corrugated web girder with deep depth as bending member, which is generally being utilized in both factory and warehouse nationwide. To accomplish this, we performed the loading test of H-shaped beam with sinusoidal corrugated web. Corrugated web CP-2.3 specimen exhibited 12% less maximal bending strength but CP-3.2 specimen exerted 24% increase in strength compared to plate web P-4.5. this result indicates that corrugated web provides enough strength even with unfavorable width-thickness ratio of plate. And bending as well as shear strength estimated by the Eurocode (EN 1993-1-5) were compared with both bending strength by loading test and shear strength estimated by KBC2009. In case of eurocode, increase in plate thickness did not help in bending performance improvement. moreover, shear performance was sensitive to the thickness of the web folds and the shape of the web plate.

Optimum Structural Design of Sinusoidal Corrugated Web Beam Using Real-valued Genetic Algorithm (실변수 유전자 알고리즘을 이용한 사인형 주름 웨브 보의 최적구조설계)

  • Shon, Su-Deok;Lee, Seung-Jae
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.5
    • /
    • pp.581-593
    • /
    • 2011
  • The underlying advantages of using thin-walled corrugatedwebs instead of plate girders with stiffeners are the elimination of instability problems associated with buckling of the thin-walled flat plate, and elimination of the need for transverse stiffeners, which alsoresults in economic advantages. This paper focuses on two aspects related to the structural design technique forsinusoidal corrugated web steel beams, and the optimum design of the beams using real-value genetic algorithms. The structural design process and design variables used in this optimization werecomposed with EN 1993-1-5, DASt-R015 standard and Pasternak et al. (2004), and the valid design capacity of shear buckling of the standards were compared. For the optimum structural design, the objective function, presented as the fullweight of the sinusoidal corrugated web beams, and the slenderness, member forces, and maximum deflection of the beam, were considered constraints. Finally, the simple beam under the uniform load was adopted as a numerical example, and the effective probability parameters of the genetic operators were considered to find the global minimum point.