• Title/Summary/Keyword: 보강 섬유

Search Result 1,623, Processing Time 0.025 seconds

Unconfined Compressive Strength of Cemented Sand Reinforced with Short Fibers (단섬유를 사용한 시멘트 혼합토의 일축압축강도 특성)

  • Park, Sung-Sik;Kim, Young-Su;Choi, Sun-Gyu;Shin, Shi-Eon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4C
    • /
    • pp.213-220
    • /
    • 2008
  • A study on cemented sand reinforced with short fibers was carried out to improve its unconfined compressive strength and brittle behavior. Nak-dong River sand was mixed with Portland cement and polyvinyl alcohol (PVA) fibers. A PVA fiber widely used for concrete reinforcement is randomly distributed into cemented sand. Nak-dong River sand, cement and fibers with optimum water content were compacted in 5 layers and then cured for 7 days. The effect of fiber reinforcement rather than cementation was emphasized by using a small amount of cement. Weakly cemented sand with a cement/sand ratio less than 8% was fiber-reinforced with different fiber ratios and tested for unconfined compression tests. The effect of fiber ratio and cement ratio on unconfined compressive strength was investigated. Fiber-reinforced cemented sand with 2% cement ratio showed up to six times strength to non-reinforced cemented sand. Because of ductile behavior of fiber-reinforced specimens, an axial strain at peak stress of specimens with 2% cement ratio increases up to 7% as a fiber ratio increases. The effect of 1% fiber addition into 2% cemented sand on friction angle and cohesion was analyzed separately. When the fiber reinforcement is related to friction angle increase, the 8% of applied stress transferred to 1% fibers within specimens.

Tensile Strength of Cement Mortar using Pitch-based Carbon Fiber Derived from Oil Residues (석유피치 재활용 탄소섬유를 혼입한 모르타르의 인장 특성)

  • Rhee, Inkyu;Lee, Jun Seok;Kim, Jin Hee;Kim, Yoong Ahm;Kim, Woo
    • Resources Recycling
    • /
    • v.26 no.6
    • /
    • pp.20-28
    • /
    • 2017
  • The direct tensile strength of the mortar specimen containing pitch-based carbon fiber was ranged between 1/27~1/22 as compared to the average compressive strength of mortar. It was found that the direct tensile strength of the mortar containing the same amount of PAN-based carbon fiber was around 1/15. While the case of the control specimen without the carbon fiber was around 1/29. One the other hands, the flexural tensile strength of the mortar containing pitch-based carbon fibers was about 1/12 as compared to the average compressive strength. In case of the mortar specimen with PAN-based carbon fiber and control mortar were 1/10 and 1/13.5, respectively. The tensile performance of the mortar with pitch-based carbon fiber was found to be intermediate between control mortar and the reinforced mortar incorporated with the PAN-based carbon fiber.

Deformation Analysis of Geosynthetic Reinforced Retaining Wall by Using Temperature Dependent Confined Tension Test Results (온도제어 구속인장시험에 의한 토목섬유 보강토옹벽의 변위해석)

  • 김홍택;방윤경;조용권
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.2
    • /
    • pp.97-106
    • /
    • 2003
  • In this study, the effect of temperature and soil confining stress on geosyntheic stress-strain properties was quantified by performing the temperature dependent confined tension tests for four types of geosynthetic including woven geotextile, composite, geomembrane and geogrid specimen. Temperature instrumentation on the GRS-retaining wall constructed in Jaechon-shi area was also performed to examine the a seasonal temperature variation of geosynthetic reinforcements in the backfill. Based on the test results, a comparison was made between unconfined and confined moduli far each temperature to quantify the soil confinement and temperature effect on stress-strain properties. And it was also proposed that the simple expressions for the secant moduli of geosynthetics as a function of temperature and confining stress on geosynthetics. As a result of the FDM analysis of GRS-retaining wall, the method of considering the effect of temperature and confining stress on geosynthetic reinforcements when performing the FDM analysis of GRS-retaining wall was proposed.

Static and Fatigue Flexural Tests of Ductile High-performance Fiber Reinforced Cementitious Composites (고인성 섬유보강 콘크리트의 정적 및 피로 휨시험)

  • Shin, Kyung-Joon;Lee, Do-Keun;Lee, Kyoung-Chan;Kim, Sung-Il
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.4
    • /
    • pp.602-608
    • /
    • 2021
  • Recently, research and development has been conducted to impart high performance and functionality to concrete materials by mixing various reinforcing materials into the matrix. Ductile fiber reinforced concrete using a large amount of fibers shows a distributed multiple cracking behavior, and various studies are being conducted on this material. However, research is focused on static behavioral analysis but studies on cyclic behaviors are not sufficient. In this study, beams were made of ductile fiber reinforced concrete with various fiber contents, and static and fatigue flexural tests were performed. As a result, the effect of fiber content on the flexural behavior was analyzed. Also, the applied load level and fatigue life relationship of ductile fiber reinforced concrete was proposed. Concrete with high ductile property could be achieved with a fiber content of 2%. When 0.5% fiber was more added, the maximum flexural strength was similar, but the flexural toughness is nearly doubled. On the other hand, there was no significant difference in the fatigue life of these two mixtures.

Theoretical Analysis of Soil Arching in Geosynthetic-Reinforced and Pile-Supported Embankment Systems (토목섬유보강 성토지지말뚝시스템의 지반아칭에 관한 이론해석)

  • Hong, Won-Pyo;Lee, Jae-Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.2C
    • /
    • pp.133-141
    • /
    • 2008
  • Theoretical analysis are developed to estimate the load transfer by soil arching in geosynthetic-reinforced and pile-supported(GRPS) embankment systems. According to the results of analyses, the efficiency of embankment pile systems increases when the geosynthetics are installed with piles. Especially the increment of efficiency is more remarkable in the low embankment height, where soil arching can not be fully developed. The factors affecting the load transfer in GRPS embankment systems are the pile spacing, the height and properties of embankments, and the strength of geosynthetics. The efficiency decreases with increasing the pile spacing, while it increases with the height and internal friction angle of embankment fills, and the strength of geosynthetics. These results of analyses show the proposed analysis method is resonable to estimate the soil arching in GRPS embankment systems.

Performance Evaluation of Organic and Inorganic Fiber Reinforced Concrete in Tunnel Lining Structure (유·무기 섬유 혼입 터널 라이닝 콘크리트 부재의 성능 평가)

  • Lee, Jong-Eun;Kim, Tae-Won;Kim, Su-Man;Jeon, Joong-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.3 s.55
    • /
    • pp.110-118
    • /
    • 2009
  • The tunnel structure is widely used for transportation in the mountain area. To reduce the duration of construction and thus the expense, a tunnel excavation is often performed simultaneously with a tunnel lining in in-situ. However, cracking of the tunnel lining may occur arising from the vibrating impact in the excavation process. The present study concerns the role of steel fiber and nylon fibers in tunnel lining concrete to reduce the vibrating impact. As a result it was found that both the nylon fiber and steel fiber improved the durability and physical properties of concrete.

A Study on Fiber Reinforced Cement using PVA and Carbon Fiber (PVA와 탄소섬유를 이용한 섬유강화시멘트에 관한 연구)

  • 김민영;이준석;김종원;이동률
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2003.10b
    • /
    • pp.67-69
    • /
    • 2003
  • 콘크리트는 경제성과 압축강도, 내구성 및 강성 등의 우수한 물성을 가지고 있으나 인장, 휨 및 충격강도가 낮고 에너지 흡수능력이 작아 취성적이며 균열에 대한 저항성이 작은 단점을 가지고 있다. 이러한 단점을 개선하기 위해서 각종 섬유를 콘크리트에 분산시켜 만든 섬유보강시멘트(FRC : Fiber Reinforced Cement)의 개발 및 이용이 활발히 진행되고 있다. PVA 섬유는 우수한 선형성, 입체구조의 간략함과 규칙성, 고결정성 그리고 우수한 접착성을 가지며, 유기 고분자로는 유일하게 PH 13.5이상의 격렬한 알칼리 조건에서도 거의 손상되지 않는 우수한 내알칼리성을 가지고 있다. (중략)

  • PDF

Evaluation of Flexural Performance of Eco-Friendly Alkali-Activated Slag Fiber Reinforced Concrete Beams Using Sodium Activator (나트륨계 알칼리 활성화제를 사용한 친환경 알카리활성 슬래그 섬유보강콘크리트 보의 휨성능 평가)

  • Ha, Gee-Joo;Yi, Dong-Ryul;Ha, Jae-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.2
    • /
    • pp.170-178
    • /
    • 2015
  • In this study, it was developed eco-friendly alkali-activated slag fiber reinforced concrete using ground granulated blast furnace slag, alkali activator (water glass, sodium hydroxides), and steel fiber. Eight reinforced concrete beam using alkali-activated slag concrete were constructed and tested under monotonic loading. The major variables were mixture ratio of alkali activator, mixed/without of steel fiber. Experimental programs were carried out to improve and evaluate the flexural performance of such test specimens, such as the load-displacement, the failure mode, the maximum load carrying capacity, and ductility capacity. All the specimens were modeled in scale-down size. The reinforced concrete beams using the eco-friendly alkali-activated slag fiber reinforced concrete was failed by the flexure or flexure-shear in general. In addition, the maximum strength increased with the adding the mol of sodium hydroxide, and the specimen reinforced the steel fiber showed the value of maximum strength which is increased by 15.8% through 25.9%. It is thought that eco-friendly alkali-activated slag fiber reinforced concrete can be used with construction material and product to replace normal concrete. If there is applied to structures such as precast concrete member and production of 2nd concrete product, it could be improved the productivity and reduction of construction duration etc.

Influence of Constitute Factor on the Compressive Strength of Ultra-High Strength Steel Fiber Reinforced Cementitious Composites (초고강도 강섬유 보강 시멘트 복합체의 구성인자가 압축강도에 미치는 영향)

  • Park Jung-Jun;Koh Kyung-Taek;Kang Su-Tae;Kim Sung-Wook
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.1 s.85
    • /
    • pp.35-41
    • /
    • 2005
  • Recently, various fiber reinforced cementitious composites are used in order to solve problems of concrete as the brittleness breaking. Especially, in U.S.A., Europe, and Japan, ultra-high strength steel fiber reinforced cementitious composites(ultra-high strength SFRCC) with compressive strength in excess of 100 MPa were developed. However few studies have been investigated on the high-strength SFRCC in Korea. Therefore, in this paper, to make ultra-high strength SFRCC with the range of compressive strength 180MPa, it was investigated the constitute factors of ultra-high strength SFRCC influenced on the compressive strength. The experimental variables were water-binder ratio, replacement of silica fume, size and proportion of sand, type and replacement of filling powder, and using of steel fiber in ultra-high strength SFRCC. As a result, in water-binder ratio 0.20, we could make ultra-high strength SFRCC with compressive strength of 180MPa through using of silica fume, quartz sand with below 0.5mm filling powder and steel fiber.

Delamination Detection of Retrofitted Concrete Using Horn Antenna (Horn Antenna를 이용한 콘크리트 보강재의 박리탐사 실험)

  • Rhim, Hong-Chul;Cho, Young-Sik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.5
    • /
    • pp.409-416
    • /
    • 2007
  • In accordance with the increased usage of reinforcing materials such as carbon fibers and glass fibers, delamination detection between concrete and the reinforcing material is needed as such delaminations may be a major cause for strength reduction or failure of a structure. In this work, 15 GHz center frequency with 10 GHz band width horn antenna was used to detect delamination between concrete and carbon fibers or glass fibers. The specimens measured $600\;(length)\;{\times}\;600\;(width)\;{\times}\;100\;(thickness)\;mm$, and glass fibers and carbon fibers with a thickness of 1.5 mm were attached on the specimens' surfaces using epoxy. In addition, artificial delaminations of size $50\;(length)\;{\times}\;50\;(width)\;mm$ were placed in the middle of the specimen with thickness of 2, 4, 6 mm respectively together with a 2 mm delamination projecting upwards from the surface of the concrete. Therefore a total of 8 specimens were used, 4 specimens for glass fiber reinforced concrete and 4 for carbon fiber reinforced concrete, containing delaminations as described above. The experiment results were derived by using the difference of area under the curved graph. According to experimental results artifical delaminations were identified in both fiber reinforced and carbon reinforced specimens and these results could contribute to further development of delamination detection technology.