• Title/Summary/Keyword: 보강상세

Search Result 245, Processing Time 0.027 seconds

Seismic Capacity of Non-seismic Designed RC Framed Building Retrofitted by CBD System (CBD 시스템으로 보강된 비내진 RC 골조의 내진성능 평가)

  • Hur, Moo-Won;Lee, Sang-Hyun;Chun, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.6
    • /
    • pp.625-632
    • /
    • 2015
  • In this study, a comparative analysis have been conducted to examine seismic reinforcement effect of a school building that is designed with a CBD (Channel Beam Damper) system supported by H-frame with existing non-seismic RC frame. As a result of experiment, seismic reinforcement specimen with CBD system showed hysteretic characteristics of a large ellipse with great energy dissipation ability and increased strength and stiffness, while non-seismic design specimen showed rapid reduction in strength and brittle shear failure at top and bottom of the left and right column. In addition, comparing the stiffness reduction between the two specimens, CBD system was effective in preventing the reduction of stiffness. Energy dissipation ability of specimen reinforced by CBD system was about 4.0 times higher than the non-reinforced specimen. Such enhancement in energy dissipation ability could be considered as the result of improved strength and deformation for further application in designing of seismic reinforcement.

Seismic Performance of Steel Coupling Beam and RC Shear Wall under Lateral Cyclic Load (주기하중 하에서 철근 콘크리트 전단벽체와 철골 연결보 접합부의 내진성능)

  • Lim, Woo-Young;Hong, Sung-Gul
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.6
    • /
    • pp.591-602
    • /
    • 2015
  • In this paper, cyclic loading test was performed to evaluate the seismic performance of the steel coupling beam and RC shear wall. The test parameter was reinforcement detail of the shear wall. For the shear wall which was designed in accordance with the current design codes, a premature bearing failure occurred at the face of the wall. On the other hand, the bearing failure of walls was prevented due to the new type of reinforcement details. Test results indicated that the vertical reinforcements were more affected to the shear strength of the coupled shear wall than the horizontal reinforcement. Based on the failure mode, concrete stress distribution above and below flanges of the embedded steel beam was proposed. Assuming proposed concrete stress distribution, load resistance was predicted and it was agree well with test data.

Permeation Grouting Effect for Repair and Reinforcement of Old Dam (노후댐 보수보강을 위한 침투그라우팅 효과 분석)

  • LEE, Dong-Beom;Lim, Heui-Dae;Song, Young-Su
    • The Journal of Engineering Geology
    • /
    • v.28 no.2
    • /
    • pp.277-295
    • /
    • 2018
  • As it has become difficult to secure new water resources through dam construction due to the critical social public opinions on dam construction from 10 years ago, it is necessary to review the existing water resources through the review of existing dams. Accordingly, access methods, such as planning, construction and management, were carried out using technologies already accumulated in relation to the repair and reinforcement of the dam. As a result of the repair and reinforcement, permeation grouting has been performed in many dams, but the establishment of the technology is insufficient so far, and the published paper at home and abroad is extremely rare. In this thesis, low-pressure penetration and grouting reinforcement technologies for the YC dam are analyzed in detail. As a result, penetration grouting has shown that it can be effectively applied to the improvement in the constallability of the core fill-like a YC dam. In addition, the technical details of the experience-proven penetration grouting are given in relation to the injection criteria. It is deemed that the specific analysis data of the Fill Dam penetration grouting technology through this study can be used as useful data for strengthening the repair of Fill Dam and reservoir.

Seismic Retrofit of Existing RC Structure Using Hysteretic Dampers (이력댐퍼를 이용한 기존 RC구조물의 내진보강)

  • Choe, Seon-Yeong
    • Computational Structural Engineering
    • /
    • v.26 no.2
    • /
    • pp.37-42
    • /
    • 2013
  • 준공 후 상당한 시간이 지나 내진설계가 되지 않았거나 내진상세가 이루어지지 않은 건물의 부족한 내진성능을 보완하기 위한 방법의 하나로 좌굴이 제한된 가새형 댐퍼를 적용할 수 있다. 이 방법을 적용할 경우, 기존 내진보강법의 불확실성을 줄일 수 있었음에도 불구하고, 댐퍼의 설계과정이 복잡하여 실무에 적용하기 어려웠다. 그러나 본 원고에서는 강성과 강도개념을 적용한 댐퍼의 설계법을 적용함으로써, 실무에서 쉽게 적용할 수 있도록 하였다. 준공된 지 16년이 지난 비틀림 비정형 건물에 대한 내진성능을 평가한 후, 가새형 댐퍼로 보강한 결과는 다음과 같다. (1) 일방향해석결과 나타난 골조별 하중-지붕변위의 관계를 이용하여, 연약골조의 강성을 강한 골조의 강성과 일치시키고, 이 강성비로부터 댐퍼가 부담하는 최적의 내력비율을 정하여 내진보강을 수행한 결과, 가새를 설치한 방향으로는 가새형댐퍼가 비틀림 방지와 연성증대효과를 구조물에 부여하여 성능이 획기적으로 증가하였다. 또한, 그 가새의 직각방향 하중에 대해서도 가새를 설치함으로써 비틀림 강성이 증가하고, 가새와 코어벽체가 인장과 압축으로 횡력에 저항하여 횡저항 성능이 증가하였다. (2) 내진성능이 부족한 비틀림 비정형 건물의 내진성능을 증진시키기 위해 가새형 댐퍼를 적용함에 있어, 댐퍼의 강성을 이용하여 구조체의 비틀림 거동을 최소화하고, 연성을 증진시키는 방법을 체택할 경우, 실무자들이 보다 쉽게 적용할 수 있으면서 그 효과도 상당히 클 것으로 기대된다.

Behaviors According to the Reinforcing Method of the Support Diaphragm Manhole in Steel Box Girder Bridge (강박스거더 지점부 다이아프램 맨홀의 보강방법에 따른 거동)

  • Lee, Seong Haeng;Kim, Kyoung Nam;Jung, Kyoung Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.6 s.79
    • /
    • pp.649-660
    • /
    • 2005
  • Since the diaphragm manhole of steel box girder bridges is designed generally from experience, it has become the primary factor in the excessive cost of steel bridge construction. For the economical and efficient manufacture of diaphragm manholes, it is necessary to study the exact behavior of the diaphragm manhole in a steel box girder bridge. In this study, both an experimental test and a structural analysis are performed to verify the behavior of the diaphragm manhole in a steel box girder bridge. A detailed structural analysis was performed according to various diaphragm manhole shapes, and in conclusion, the suitable reinforcement method for the support of diaphragm manholes in steel box bridges is presented.

Seismic Performance Evaluation of Nonseismic Neighborhood Living Facilities Considering Deterioration (비내진 근린생활시설의 노후도를 고려한 내진성능평가)

  • Lee, Young Cheon;Jeoung, Chae Myeoung;Lee, Eun Jin;Kim, Myung Hoon;Choi, Ki Bong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.1
    • /
    • pp.55-63
    • /
    • 2013
  • In this study, seismic performance was evaluated considering the deterioration level for the low-rise and moderate buildings with non-seismic details which are most common in Korea. Evaluation results showed that the deterioration condition is relatively good even after 24 years of construction but the seismic performance did not satisfy the protection index in the first and second evaluation. In case of the third evaluation, the goal performance was satisfied based on the interstory drift ratio but reinforcement is found to be necessary. Seismic performance was evaluated after the target buildings were reinforced in the walls, bracing, and damper. Results showed the interstory drift ratio drastically reduced regardless of reinforcement methods and satisfied the level of immediate occupancy. In case of wall reinforcement, however, base shear increased more than double which requires review on the existing foundation.

Evaluation of Shear Performance of Reinforced Concrete Beams for Varying Reinforcement Details of Web Opening (유공부 보강상세에 따른 철근콘크리트 유공 보의 전단 성능 평가)

  • Kim, Min-Jun;Lee, Bum-Sik;Kim, Dong-Whan;Kim, Hyeong-Gook;Lee, Yong-Jun;Kim, Kil-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.4
    • /
    • pp.19-26
    • /
    • 2018
  • This study evaluates the shear performance of reinforced concrete members with web opening reinforcement. A total of 4 reinforced concrete members with or without openings were cast then tested. The main variables investigated were with or without of web openings and with or without of web opening reinforcement, respectively. The proposed web opening reinforcement was a rectangle and rhombus-shaped spiral considering of construct ability. Test result showed that the proposed web reinforcement had improved shear capacity and ductility of the specimens. It was found that the web opening reinforcement proposed in this study had a positive effect on the shear strength and crack control of RC beams with web openings. In addition, it was confirmed that the analytical results by the current design codes underestimates the test results of the specimens with the proposed web opening reinforcement.

Numerical Analysis for Optimum Reinforcement Length Ratio of Reinforced Earth Retaining Wall (보강토옹벽의 최적 보강길이비 산정을 위한 수치해석적 연구)

  • Park, Choonsik;Ahn, Woojong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.12
    • /
    • pp.5-14
    • /
    • 2018
  • Recently, method of reinforced earth retaining wall have been proposed according to the material of facing, geosynthetic, construction method, and facing slope. However, the regulations such as the design method and detailed review items according to each construction method are not clear, and collapse due to heavy rainfall frequently occurs. In this study, to obtain a more stable technical approach in the design of reinforced earth retaining wall, the combination of the pullout failure of reinforced earth retaining wall and the optimal reinforcement ratio of height using reinforced earth retaining wall using a single strength reinforcement is assumed, optimum design of stiffener, optimal design of superimposed wall and optimum length ratio of reinforcement material of geosynthetics are proposed through safety factor according to reinforcement length ratio (L/H).

Concrete Shear Strength of FRP Reinforced Concrete Beam (FRP 보강근을 사용한 콘크리트 보의 콘크리트 전단강도)

  • Cho, Jae Min;Jang, Hee Suk;Kim, Myung Sik;Kim, Chung Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.3A
    • /
    • pp.259-266
    • /
    • 2009
  • This study is to develop equations that consider the elastic modulus ratio of FRP bar and steel reinforcement, shear span to depth ratio, and flexural reinforcement ratio of FRP bar, to determine concrete shear strength of FRP reinforced concrete beams without shear reinforcement. As experimental parameters, 2 types of FRP bar, 3 types of shear span to depth ratio, and 3 types of flexural reinforcement were used. Experimental results for two of shear span to depth ratio were quoted from previous study to evaluate effect of shear span to depth ratio in more detail. Shear strength correction factors needed for evaluating concrete shear strength were proposed from regression analysis using above experimental results. Equations suggested from this study and other codes were examined and compared with 31 experimental results available in the literature. From this comparison, it could be known that the equation suggested from this study gives the most approaching result to experimental results.

Evaluation of the Effective Width and Flexural Strength of the T-Stalled Walls (T형 벽체의 유효 폭 및 휨강도 평가)

  • 양지수;이리형
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.796-803
    • /
    • 2002
  • T-shaped walls have different strength, stiffness and ductility in the two opposite directions parallel to the web when subjected to horizontal in-plane loads. When the flange is in tension, the extent that the flange reinforcement contributes to the flexural strength will be subjected to shear-lag effect. Because of this shear-lag effect, the flange may not participate fully in the action with the web, and the effective flange width is needed for predicting the actual strength and stiffness of structures. The objective of this paper is to evaluate the effective flange width and actual strength of the T-shaped wall with Korean code specified detailing of the wall web. Three specimens were tested with cyclic lateral loading applied at top of the wall. A constant axial load of approximately 0.1f$\_$ck/$.$A$\_$g/ is maintained during the testing. Test results show that the effective flange width increases with increasing drift level, such that the entire overhanging flange of h/3 is effective at the maximum strength level. Therefore, the use of PCI or KBC(Korean Building Code) value of h/10 is unconservative with respect to detailing at the wall web boundary.