Experimental and Analytical Study on the Steel Beam bonded with CFRP Strip (레진으로 접착 보강한 강재보의 거동)

  • Sung, Ikhyun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.1
    • /
    • pp.81-88
    • /
    • 2017
  • In this paper, the behaviour of composite steel-CFRP members is studied experimentally and using FE-analysis. The use of advance composite materials in construction for repair and rehabilitation has become a frequent used method in the last decade. FRP composites have many advantages over the traditional technique of steel bonding for a number of reasons: 1. Composites add little or no additional weight to a building, eliminating the need for costly foundation strengthening. 2. FRP composites are very thin (1.2mm to 1.4mm). So there is no loss of floor space and negligible effect over the architectural aspect. 3. FRP composites do not corrode, this makes it long lasting. However, the method is yet to become a mainstream application due to a number of economical and design related issues. Brittle debonding failure, aging effect on bonding, broad based awareness and proper design guidelines are the main concern for future research works. This paper is focused on the ultimate load carrying capacity of the CFRP-strengthened beams and their effect on the deflection and failures modes by varying the amount of CFRP content.

Enhancing the Performance of Polypropylene Fiber Reinforced Cementitious Composite Produced with High Volume Fly Ash (폴리프로필렌 섬유로 보강된 하이볼륨 플라이애시 시멘트 복합재료의 성능 향상 기법)

  • Lee, Bang Yeon;Bang, Jin Wook;Kim, Yun Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.3
    • /
    • pp.118-125
    • /
    • 2013
  • The synthetic fibers including Polyvinyl alcohol and Polyethylene fibers have been successfully used in the manufacture of high ductile fiber reinforced cementitious composites. Polypropylene (PP) fiber has also been used in composites, not for the purpose of achieving a high level of tensile ductility but to improve the fire resistance performance of concrete exposed to high temperatures. This paper discusses the method for enhancing the performance of composites supplemented with PP fiber. Five types of mixture proportions were designed with high volume fly ash for testing the performance of composites. Type I cement and fly ash F were used as binding materials. The water-to-binder ratio was 0.23~0.25, and the amount of PP fiber used was 2 vol%. Polystyrene bead were also used to increase the tensile ductility of composites. A series of experiments including slump, density, compression and uniaxial tension tests were performed to evaluate the performance of cementitious composites supplemented with PP fiber. From the test results, it was exhibited that the performance of composites supplemented with PP fiber can be enhanced by adopting the mechanics and statistics theory.

고체산화물연료전지에 사용되는 밀봉재 개발 및 특성 평가

  • Gwon, Yong-Jin;Choe, Byeong-Hyeon;Ji, Mi-Jeong;Lee, Seo-Hwan;Seol, Gwang-Hui;Nam, San
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2012.05a
    • /
    • pp.95.2-95.2
    • /
    • 2012
  • 고온형 SOFC의 개발에 있어 스택의 신뢰성을 확보하는데 가장 중요한 핵심기술은 스택 구성요소 사이를 접합하는데 필요한 고온형 밀봉재의 개발이다. SOFC 스택에서의 밀봉재는 고체전해질과 접속자 사이에서 음극에 공급되는 연료가스와 양극에 공급되는 공기가 서로 혼합되는 것을 방지하는 역할은 물론 기계적으로 취약한 단전지의 보호 및 스택전체 구조물의 구조적 일체성(Structural integrity)을 부여하는데 주목적이 있다. 현재 기체 기밀성을 유지하기 위한 밀봉재는 크게 유리 및 결정화 유리계, mica및 mica/유리복합재료, 유리/충전재 복합재료 등이 사용되고 있으나 다수의 단위전지로 구성되는 스택 구성에서 스택의 열기계적 안정성 및 장기수명을 보장하기 위해서는 본 연구에서 개발하고자 하는 복합밀봉재가 가장 적합할 것으로 예상되고 있다. 본 연구에서는 SiO-B2O3-RO계에 BaO, SrO를 일정비율로 첨가하여 제작된 유리 frit을 열처리하여 물리화학적 물성변화를 검토하였으며, $750^{\circ}C$ 이하의 연화점을 갖는 유리를 기지상으로 하고 세라믹 보강재를 첨가한 고온형 복합밀봉재를 개발하고 그 물리화학적 안정성, 열기계적 안정성 및 밀봉 특성을 평가하였다.

  • PDF

Structural Behavior of the Reinforced Concrete Filled GFRP Tube (GFRP 보강 철근콘크리트 합성부재의 구조적 거동)

  • Lee, Seung-Sik;Joo, Hyung-Joong;Kang, In-Kyu;Yoon, Soon-Jong
    • Composites Research
    • /
    • v.23 no.4
    • /
    • pp.44-51
    • /
    • 2010
  • Recently, to solve the problems associated with the neutralization and corrosion of reinforced concrete compression members, the structural configurations such as CFFT (Concrete Filled GFRP Tube) and RCFFT (Reinforced Concrete Filled GFRR Tube) have been developed and applied to main members of civil engineering structure. These members can increase structural performance in terms of structural stability, ductility as well as chemical resistance compared with conventional concrete structural members. Many researches in numerous institutions to predict the load carrying capacity of the concrete compression member strengthened with FRP materials have been conducted and they have been suggested an equation for the prediction of the load carrying capacity of the members. Through the review of the research results, it was found that their results are similar each other. Moreover, it was also found that the results are not directly applicable to our specimens since the results are largely depended upon the member configurations. Also, since the accurate design criteria for the RC members strengthened with FRP such as RCFFT have not been established properly, relevant theoretical and experimental investigations must be conducted for the application to the practical structures. In this study, structural behavior of RCFFT was evaluated through compressive and quasi-static flexural tests in order to formulate design criteria for the structural design. In addition, the RCFFT members were also investigated to examine their confinement effect and the equations capable of estimating the compressive ultimate strength and flexural stiffness of the RCFFT members were proposed.

Experimental Study on Blast Resistance Improvement of RC Panels by FRP Retrofitting (철근콘크리트 패널의 FRP 보강에 의한 방폭 성능 향상에 관한 실험 연구)

  • Ha, Ju-Hyung;Yi, Na-Hyun;Kim, Sung-Bae;Choi, Jong-Kwon;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.1
    • /
    • pp.93-102
    • /
    • 2010
  • Recently, FRP usage for strengthening RC structures in civil engineering has been increasing. Especially, the use of FRP to strengthen structures against blast loading is growing rapidly. To estimate FRP retrofitting effect under blast loading, blast tests with nine $1,000{\times}1,000{\times}150\;mm$ RC panel specimens, which were retrofitted with carbon fiber reinforced polymer (CFRP), Polyurea, CFRP with Poly-urea and basalt fiber reinforced polymer (BFRP) have been carried out. The applied blast load was generated by the detonation of 15.88 kg ANFO explosive charge at 1.5 m standoff distance. The data acquisitions not only included blast waves of incident pressure, reflected pressure, and impulse, but also included central deflection and strains at steel, concrete, and FRP surfaces. The failure mode of each specimen was observed and compared with a control specimen. From the test results, the blast resistance of each retrofit material was determined. The test results of each retrofit material will provide the basic information for preliminary selection of retrofit material to achieve the target retrofit performance and protection level.

SOFC 밀봉재로서 $SiO_2-B_2O_3-RO$계에서 RO 변화에 따른 밀봉특성

  • Gwon, Yong-Jin;Choe, Byeong-Hyeon;Ji, Mi-Jeong;An, Yong-Tae;Seol, Gwang-Hui;Nam, San
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.10a
    • /
    • pp.33.2-33.2
    • /
    • 2011
  • 고온형 SOFC의 개발에 있어 스택의 신뢰성을 확보하는데 가장 중요한 핵심기술은 스택 구성요소 사이를 접합하는데 필요한 고온형 밀봉재의 개발이다. SOFC 스택에서의 밀봉재는 고체전해질과 접속자 사이에서 음극에 공급되는 연료가스와 양극에 공급되는 공기가 서로 혼합되는 것을 방지하는 역할은 물론 기계적으로 취약한 단전지의 보호 및 스택전체 구조물의 구조적 일체성(Structural integrity)을 부여하는데 주목적이 있다. 현재 기체 기밀성을 유지하기 위한 밀봉재는 크게 유리 및 결정화 유리계, mica및 mica/유리복합재료, 유리/충전재 복합재료 등이 사용되고 있으나 다수의 단위전지로 구성되는 스택 구성에서 스택의 열기계적 안정성 및 장기수명을 보장하기 위해서는 본 연구에서 개발하고자 하는 복합밀봉재가 가장 적합할 것으로 예상되고 있다. 본 연구에서는 $SiO_2-B_2O_3-RO$계에 BaO, SrO를 일정비율로 첨가하여 제작된 유리 frit을 열처리하여 물리화학적 물성변화를 검토하였으며, $700^{\circ}C$ 이하의 연화점을 갖는 유리를 기지상으로 하고 세라믹 보강재를 첨가한 고온형 복합밀봉재를 개발하고 그 물리화학적 안정성, 열기계적 안정성 및 밀봉 특성을 평가하였다.

  • PDF

Shape Design and Performance Evaluation of FRP Box-type Stiffener For the Application of RC Structure (철근콘크리트용 FRP Box 휨 보강재의 형상 설계 및 거동 평가)

  • Kwon, Min-Ho;Jung, Woo-Young;Spacone, Enrico
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.4 no.1
    • /
    • pp.40-46
    • /
    • 2013
  • This paper presents the design, fabrication and performance of a reinforced concrete beam strengthened by GFRP box plate and its possibility for structural rehabilitations. The load capacity, ductility and failure mode of reinforced concrete structures strengthened by FRP box plate were investigated and compared with traditional FRP plate strengthening method. This is intended to assess the feasibility of using FRP box plate for repair and strengthening of damaged RC beams. A series of four-point bending tests were conducted on RC beams with or without strengthening FRP systems the influence of concrete cover thickness on the performance of overall stiffness of the structure. The parameters obtained by the experimental studies were the stiffness, strength, crack width and pattern, failure mode, respectively. The test yielded complete load-deflection curves from which the increase in load capacity and the failure mode was evaluated.

A study on the acoustic emission characteristics of laminated composite structures (복합재료 적층 구조물의 음향방출 특성 연구)

  • 박재성;김광수;이호성
    • Composites Research
    • /
    • v.16 no.6
    • /
    • pp.16-22
    • /
    • 2003
  • This paper studied the AE(acoustic emission) characteristics of the laminated composite structures. The composite stiffened panels under the compressive loading emitted various AE signals when they buckled or changed the buckling modes. In addition, the failure initiated and propagation generated a lot of complex signals. From the continuous signal generation. we identified when the failures initiated and whether they propagated or not. The single lap joint of laminated plates under tensional load also generated AE signals when bonding region failed. The first failure occurrence and its propagation are monitored by generated AE signals. The characteristics of AE signals used in this analysis are cumulative hits, hit distribution, peak frequency of generated AE waveform and amplitude of signals. The analysis of AE signals shows that continuous increment of cumulative hits can be regarded as damage propagation and three dominant peak frequencies can correspond to typical failure modes in the laminated composites.

Manufacturing of Hybrid Metal Matrix Composites used $Al_2O_3$ Short Fiber and $Al_2O_3$-TiC Composite Powder Synthesized by SHS Process (SHS법에 의해 제조된 $Al_2O_3$-TiC복합분말과 $Al_2O_3$단섬유를 강화재로 사용한 하이브리드 금속기 복합재료의 제조)

  • Kim, Dong-Hyeon;Maeng, Deok-Yeong;Lee, Jong-Hyeon;Won, Chang-Whan
    • Korean Journal of Materials Research
    • /
    • v.9 no.3
    • /
    • pp.315-321
    • /
    • 1999
  • Metal matrix composites have been extensively studied because of their excellent characteristics for structural application. $Al_2O_3$ and SiC have been used as a common reinforcement owing to their good mechanical properties. However the manufacturing cost of these ceramic reinforcement is expensive, so the use of the composites has been restricted to special purposes. In this study, we tested the application possibility as a reinforcement of $Al_2O_3$-TiC powder synthesized by SHS(Self-propagating High-temperature Synthesis) process to Al alloy matrix composite. Also, $Al_2O_3$ short fibers were added with the synthesized powders in order to apply to the Al matrix hybrid composites. Squeeze infiltration casting process was used to make the composite with 25vol% of reinforcement. Microstructure and crystal structure were examined by SEM, OM and XRD, also the mechanical properties were studied by the compressive test and wear test.

  • PDF

Impact and Bending Characteristics of Dual Band Composite Antennas (복합 구조 이중대역 안테나의 충격 및 굽힘 특성)

  • Shin, Dong-Sik;Kim, Jin-Yul;Park, Wee-Sang;Hwang, Woon-Bong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.2
    • /
    • pp.35-40
    • /
    • 2011
  • We have studied the impact and bending characteristics of a dual band antenna (1.575, 2.645 GHz) with composite sandwich construction. Mechanical performance of the antenna can be improved by reinforcing the antenna by sandwiching the planar antenna with layers of carbon fiber-reinforced plastic(CFRP) and glass fiber-reinforced plastic(GFRP) using an adhesive film. According to the ASTM D7137, ASTM C393 and MIL-STD401B, impact and bending test were performed and the S-parameters and gains of the antenna were measured in order to verify electrical and mechanical performance. The maximum contact load and the bending load of the antenna are 4 kN and 400 N and gains of the antenna are 6 dBi and 4.6 dBi in the GPS and DMB bands, respectively. The proposed antenna structure can be applied to surfaces of vehicles.