• Title/Summary/Keyword: 변형센서

Search Result 558, Processing Time 0.031 seconds

Monitoring of Early-age Behavior of Concrete Retaining Wall by FBG Sensors (FBG센서를 이용한 콘크리트옹벽 초기재령 특성 모니터링 연구)

  • Jang, Il-Young;Yun, Ying-Wei;Kim, Young-Gune
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.89-90
    • /
    • 2009
  • FBG temperature sensor and strain sensor has been used to monitoring shrinkage and temperature of concrete retaining wall in construction site in its casting early age. The test results indicate that this monitoring method is a practical method for monitoring concrete at very early age. The monitoring technique used in this research could be extended to monitor shrinkage and temperature for mass concrete structure.

  • PDF

Design of Six-Component F/T Sensor with Flexible Fixed Ends (유연한 고정단을 가진 6축 F/T 센서의 설계)

  • Lee, Bong-Hee;Joo, Jin-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.6
    • /
    • pp.771-780
    • /
    • 2010
  • This paper describes the design process of a six-component force/torque (F/T) sensor. The new six-component F/T sensor having leaf spring ends has been developed using a cross beam structure as the basic sensing element. Fundamental strain analysis of both ends fixed beam having a leaf spring structure is performed by finite element analysis. In order to obtain similar output sensing strains from the six component loads and minimize coupling strains, the optimal location of strain gages is determined and the strain gages are connected so that the bridge circuits with four strain gages would be balanced. Using leaf spring ends instead of rigid fixed ends, remarkable increment in output sensing strain can be achieved for two component forces. Several modifications in design result in a similar sensing strain of approximately $400\;{\mu}m/m$ for the six-component forces and moments, and a reduced coupling strain of $0\;{\mu}m/m$ between the forces and moments.

A Study on Field Application of a Deformable Rod Sensor to Large Diameter Drilled Shafts (대구경 현장타설말뚝에 대한 변형봉 센서의 현장적용성에 관한 연구)

  • 정성기;김상일;정성교;최용규;이민희
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.15-22
    • /
    • 2003
  • In the conventional load transfer analysis for a steel pipe drilled shaft, it was assumed that the concrete's strain is the same as the measured steel's strain and the elastic modulus of the steel and the concrete calculated by the formular as prescribed by specification is used in the calculation of pile axial load. But, the pile axial load calculation by conventional method differed to some extent from the actual pile load. So, the behavior of a steel pipe drilled shaft could not be analyzed exactly. Thus, the necessity to measure the strain for each pile component was proposed. In this study, a new approach for load transfer measurement of large diameter drilled shafts was suggested ; the strain of each pile component(i. e., steel and concrete) was measured by DRS(Deformable Rod Sensor), the elastic modulus was determined by the uniaxial compression test for concrete specimens made at test site and a value of elastic modulus was evaluated as average tangential modulus corresponding to the stress level of the (0.2-0.6)$f_{ck}$. Field application was confirmed by the results of load transfer measurement tests for 3 drilled shafts. The errors for calculated pile head load were -11 ∼16% and 3.4% separately.

Measuring Deformation of Cable in the Tensegrity Structure by Optical FBG Sensor (FBG센서를 이용한 텐서그리티 구조의 변형 계측)

  • Lee, Seung-Jae;Lee, Chang-Woo;Ju, Gi-Su
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.189-194
    • /
    • 2008
  • The main object of this paper is that it's possible to monitoring the deformation of cable in the tensegrity structure. always monitoring system of Fiber Bragg Grating(FBG)Sensor is described. The measurement of parts on the cable is very important. We make an experiment with measuring deformation of cable in the tensegrity structure to the pressure conditions. In the result of experiment, the fiber sensors showed good response to the pressure conditions. Therefore, We could calculate the deformation of cable structure and be possible health monitoring of the tensegrity structure.

  • PDF

Temperature Compensation Technique for Steel Sleeve Packaged FBG Strain Sensor in Structural Monitoring (Steel Sleeve Packaged FBG 변형률센서를 이용한 구조물 모니터링에서의 온도보정 기술)

  • Jang, Il-Young;Yun, Ying-Wei;Ryu, Jeong-Su;Park, Jin-Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.805-808
    • /
    • 2008
  • Due to the fact that bare FBG sensors are very fragile, bare FBG sensor is not properly applied in practical infrastructures as it is not suitable to the rudeness of construction. Therefore packaged FBG sensors are developed for construction application. Since FBG senses strain and temperature simultaneously, temperature compensation for FBG strain sensors is indispensable. In this paper, temperature compensation techniques for steel sleeve packaged FBG sensors are brought forward. And its application on monitoring concrete beam was carried to test the feasibility of the temperature compensation technique. Temperature compensation technique used in this paper is feasible to be extended to structure health monitoring in civil engineering especially in large infrastructures etc.

  • PDF

FBG Sensor Demodulation Using a Double-Pass Mach-Zhender Interferometer (더블패스 마하젠더 간섭계를 이용한 광섬유 격자 센서의 파장복조)

  • Park, Hyoung-Jun;Song, Min-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.4
    • /
    • pp.285-290
    • /
    • 2007
  • A wavelength-demodulation algorithm for FBG sensor is proposed by using a double-pass Mach-Zehnder interferometer. Zero-crossing points of double-passed interference signal are used to trigger the accurate $90^{\circ}C$ phase difference positions in the sensor signal, which is an essential condition in the subsequent arctangent and phase unwrapping signal processing. With the proposed method, we could efficiently measure various measurands, such as dynamic-, static-strain, and temperature, and ${\sim}8pm$ of wavelength resolution was obtained.

Recent Research Trend in Soft Tactile Sensor for Electronic Skin (전자피부(E-Skin)용 유연 촉각센서 연구동향)

  • Jee, Eunsong;Kim, Joo Sung;Kim, Do Hwan
    • Prospectives of Industrial Chemistry
    • /
    • v.21 no.1
    • /
    • pp.3-18
    • /
    • 2018
  • 전자피부(Electronic skin)는 외부 환경과의 상호작용하는 인간 피부의 기능을 대체하여 외부 자극 신호를 전기적 신호로 변환하는 센서들로 이루어진 인공피부로써, 최근 인간과 전자기기 간의 인터페이스에 대한 관심이 급증하면서 이에 대한 많은 연구들이 진행되고 있다. 그중에서도 피부의 주된 기능인 외부 물리적 자극을 인지하는 촉각을 모방하는 촉각센서는 많은 발전을 거쳐 왔으며, 한계를 극복하고자 다양한 연구들이 진행되고 있다. 촉각센서는 압력, 인장, 굽힘과 같은 물리적 자극에 반응하며, 물리적 자극 신호를 아날로그 및 디지털 신호로 변환하여 인지하는 연구들이 폭넓게 개발되고 있다. 또한, 소자의 구조에 따라 물리적 자극을 전달하는 다양한 변환 방식들이 있으며, 최근에는 각 신호 변환 방식의 민감도, 반응속도, 자극 인지 범위 등의 한계점을 극복하고, 소재의 기계적 물성을 향상시키기 위해 소재의 변형을 주거나 생체의 기관 구조 및 외부 자극 인지 원리 등을 모사한 연구들이 많은 관심을 받고 있다. 본 기고에서는 이러한 촉각센서의 물리적 자극 신호 변환 방식과 소재 변형 및 생체 모사를 통한 다양한 연구들을 소개하고자 하며, 이를 통하여 촉각센서의 나아갈 방향을 제시하고자 한다.

Load Transfer Characteristics of the 7-wire strand using FBG Sensor Embedded Smart Tendon (FBG센서가 내장된 스마트 텐던을 이용한 7연 강연선의 인발 하중전이 특성)

  • Kim, Young-Sang;Suh, Dong-Nam;Kim, Jae-Min;Sung, Hyun-Jong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.5
    • /
    • pp.79-86
    • /
    • 2009
  • With the substantial increase of the size of structure, the management of excavation becomes more difficult. Therefore, massive collapses which are related to retaining wall recently increase. However, since the study on measuring and monitoring the pre-stressing force of anchor is insufficient, behavior of anchor may not be predicted and monitored appropriately by the existing strain gauge and load cell type monitoring system. FBG Sensor, which is smaller than strain gauge and has better durability and does not have a noise from electromagnetic waves, is adapted to measure the strain and pre-stressing force of 7-wire strand, so called smart tendon. A series of pullout tests were performed to verify the feasibility of smart tendon and find out the load transfer mechanism around the steel wire tendon fixed to rock with grout. Distribution of measured strains and estimated shear stresses are compared with those predicted by theoretical solutions. It was found that developed smart tendon can be used effectively for measuring strain of 7-wire strand anchor and theoretical solutions underestimate the magnitude of shear stress and load transfer depth.

A Numerical Study on the Strain Based Monitoring Method for Lateral Structural Response of Buildings using FBG Sensors (FBG를 이용한 변형률 기반 건물의 횡방향 구조반응 모니터링 기법에 관한 해석적 연구)

  • Choi, Se Woon;Park, Keunhyoung;Kim, Yousok;Park, Hyo Seon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.4
    • /
    • pp.263-269
    • /
    • 2013
  • In this study, the strain based monitoring method to evaluate the lateral structural response of buildings is presented and an applicability of the proposed method is confirmed through the numerical study. It is assumed that the fiber Bragg grating(FBG) strain sensor is employed to measure the strain response of members due to the excellent properties such as multiplexing, and higher sampling frequency. These properties of FBG sensors is proper for buildings the a lot of sensors are required to monitor the reponses of those. FBG sensors measure the strain response of vertical members and are employed to calculate the curvatures of members using the measured strain responses. Then the lateral displacement, and lateral acceleration is evaluated based on the curvatures of vertical members. Additionally, these dynamic responses of buildings are used to evaluate the dynamic properties of buildings such as the natural frequencies and mode shapes using the frequency domain decomposition(FDD) method. Through the application of nine-story steel moment frame example structure, it is confirmed that the proposed method is appropriate to evaluate the lateral structural responses and dynamic properties of buildings.

Robust Beamforming Method by Linear Array Shape Estimation using Kanlman Filter (칼만필터 선배열 형상 추정에 의한 견실한 빔형성 기법 연구)

  • 한정우
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1996.06a
    • /
    • pp.18-21
    • /
    • 1996
  • 예인형 선배열 소나에서 기존의 선배열 빔형성 기법을 적용하면 예인함 기동시 선배열 형상 변형에 의해 심각한 성능 저하 현상이 나타난다. 이러한 문제 해결을 위해 센서배열 변형을 고려한 견실한 빔형성 기법은 선배열 형상 추정을 위해 칼만필터를 이용한 형상 추정기법을 이용하고, 변형보상 빔형성을 위해 선배열 세그먼트 기울기 추정값을 이용하는 변형보상 빔형성 알고리즘을 제안하였다. 제안된 기법을 기존의 빔형성 기법을 적용하여 시뮬레이션에 의해 제안된 기법의 보상성능을 입증 하였다.

  • PDF