• Title/Summary/Keyword: 변동범위

Search Result 978, Processing Time 0.027 seconds

Accuracy Evaluation of Open-air Compost Volume Calculation Using Unmanned Aerial Vehicle (무인항공기를 이용한 야적퇴비 적재량 산정 정확도 평가)

  • Kim, Heung-Min;Bak, Su-Ho;Yoon, Hong-Joo;Jang, Seon-Woong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.3
    • /
    • pp.541-550
    • /
    • 2021
  • While open-air compost has value as a source of nutrients for crops in agricultural land, it acts as a pollution that adversely affects the environment during rainfall, and management is required. In this study, it was intended to analyze the accuracy of calculating open-air compost volume using fixed-wing UAV (unmanned aerial vehicle) capable of acquiring a wide range of images and automatic path flights and to identify the possibility of utilization. In order to evaluate the accuracy of calculating the three open-air compost volume, ground LiDAR surveys and precision surveys using a rotary UAV were performed. and compared with the open-air compost volume acquired through a fixed-wing UAV. As a result of comparing the calculation of open-air compost volume based on the ground LiDAR, the error rate of the rotary-wing was estimated to be ±5%, and the error rate of fixed-wing was -15 ~ -4%. one of three open-air compost volume calculated by fixed-wing was underestimated as about -15 %, but the deviation of the open-air compost volume was 2.9 m3, which was not significant. In addition, as a result of periodic monitoring of open-air compost using fixed-wing UAV, changes in the volume of open-air compost with time could be confirmed. These results suggested that efficient open-air compost monitoring and non-point pollutants in agricultural for a wide range using fixed-wing UAV is possible.

Reliability and utility of a Dry Test Bench for testing the acoustic output from a ballistic shock wave therapeutic device (탄도형 충격파 치료기의 음향 출력 시험을 위한 Dry Test Bench의 신뢰성 및 유용성)

  • Jeon, Sung Joung;Lee, Min Young;Kwon, Oh Bin;Kim, Jong Min;Choi, Min Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.5
    • /
    • pp.589-600
    • /
    • 2022
  • In order to verify the reliability of Dry Test Bench (DTB) used for testing the output energy from ballistic extracorporeal shock wave therapeutic devices, the measurements with DTB were compared with the acoustic energy measured with a Laser Doppler Vibrometer (LDV) for a commercial ballistic ESWT device. It was shown that the mechanical energy detected with DTB had variability maintained within 5 % at the same output power setting and also had a linear correlation (adj. R2 = 0.991) with the acoustic energy measured with the LDV for the entire output power settings. Using the correlation between the two methods and the correlation on the acoustic energy measured in between air and water with the LDV, the DTB measurement can be used to estimate the energy flux density in water with an average error of 7.85 % for the entire output power settings of the ballistic shock wave generator considered in the experiment. DTB provides information limited to the output mechanical energy and therefore it is not suitable for testing the various acoustic output parameters required in IEC61846 and IEC63045. However, DTB that is simple in measurement principles and easy to use is expected for manufacturers and clinical users to monitor the performance of ballistic Extracorporeal Shock Wave Therapy (ESWT) devices.

Quality of Dry Cement Mortar for Floor Heating Depending on Water-to-Dry Mortar Rutio (난방을 위한 바닥용 건조 시멘트 모르타르의 혼합수량비 변화에 따른 품질 특성)

  • Park, Sang-Jun;Hwang, Yin-Seong;Lee, Gun-Cheol;Kim, Jong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.3
    • /
    • pp.181-188
    • /
    • 2021
  • In this study, the various performance of dry cement mortar for Korean floor heating system depending on water-to-dry mortar ratios (W/DM) applied in project site was evaluated. According to the experiment conducted, the importance of mixing water for dry cement mortar was revealed by resultant performance or quality of the dry cement mortar for floor finishing by changing W/DM controlled in project site by workers. As the general trend, the flow was increased, and the unit volume weight was decreased with increasing W/DM. Additionally, compressive strength and drying shrinkage were significantly influenced by W/DM. Hence, it can be stated that the adding water for dry cement mortar should be managed precisely since excessively increased W/DM for workability improvement can cause performance degradation of floor mortar with the failures such as excessive bleeding, and severe segregation during the fresh state. As a summary of the study, to achieve a desirable performance of dry cement mortar, approximately 20 % of W/DM can be suggested to be managed in project site.

A Study on the Adequate HD Camera Focal Length in the Broadcasting Studio using LED Video Wall (LED 비디오월을 사용하는 방송환경에서 HD 카메라의 적정 초점거리 연구)

  • Choi, Ki-chang;Kwon, Soon-chul;Lee, Seung-hyun
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.5
    • /
    • pp.713-721
    • /
    • 2022
  • In order to use the LED video wall in the broadcasting studio, there are a few things to be aware of. First, since the pixels are closely arranged, a moire phenomenon may occur due to a short arrangement period, and second, the distance between pixels (pixel pitch) may be recorded on the image sensor of the broadcasting camera. When moire occurs or pixel pitch is observed, viewers feel uncomfortable. Moire effect can be reduced by adjusting the shooting distance or angle of the camera, but in order to prevent the pixel pitch from being recorded on the image sensor, secure a sufficient distance between the LED video wall and camera. even when the distance secured, the zoom lens used in the broadcasting studio must be operated by appropriately changing the magnification. If the focal length is changed by changing the magnification to obtain a desired angle of view, the pixel pitch may be unintentionally recorded. In this study we propose the range that the pixel pitch is not observed while changing the magnification ratio of the zoom lens when the distance from the video wall is sufficiently secured. The content was played back on the LED video wall and the LED video wall was recorded on the server using an HD camera equipped with a B4 mount zoom lens

Paleostress Inferred from Calcite Twins in the Pungchon Limestone, Joseon Supergroup (조선누층군 풍촌석회암 방해석 쌍정에서 유추된 고응력장)

  • Kang, Seong-Seung;Jang, Bo-An
    • The Journal of Engineering Geology
    • /
    • v.32 no.1
    • /
    • pp.13-26
    • /
    • 2022
  • Calcite twins were analyzed in six oriented samples of the Pungchon limestone, Joseon Supergroup, to reconstruct the paleostress field. The orientations of c-axis of calcite and e twin plane were measured along with the average thickness and numbers of twins, and the widths of calcite grains. Twin strain, mean width, and intensity of twinning, and the relative magnitude and orientations of principal stresses were calculated using Calcite Strain Gauge program. Twin strain, mean width, and intensity of twinning showed ranges of 1.09-15.36%, 0.53-3.72 ㎛ and 21.0-53.1 twim/mm, respectively. Metamorphic temperatures calculated from the twins were 170-200℃, indicating that the twins developed after the Pungchon limestone was uplifted to at least half of the maximum burial depth. Results for five of the samples indicate that the calcite twins formed during two events with principal stress axes of different orientations, while the remaining sample recorded only one event that produced calcite twins. The axis of maximum compressive stress was oriented mainly WNW-ESE to ENE-WSW, and to a lesser degree NW-SE and NE-SW. Comparison of paleostress orientations measured here and in other studies indicates that most twins were produced during the Songrim orogeny. However, the Daebo orogeny and the Bulguksa orogeny also produced calcite twins in the Punchon limestone.

The Relationship among Dynamic Capability, Technology Commercialization Competence, Innovation Performance, and Competitive Advantage (수출벤처기업의 동태적 역량이 기술사업화역량, 혁신성과 및 경쟁우위에 미치는 영향)

  • Hwang, Kyung-Yun;Sung, Eul-Hyun
    • Korea Trade Review
    • /
    • v.41 no.2
    • /
    • pp.159-183
    • /
    • 2016
  • This study focuses on export venture firms in Daedeok Innopolis and examines the structural relationships among dynamic capability, technology commercialization competence, innovation performance, and competitive advantage. In particular, this study attempts to analyze dynamic capabilities that may affect technology commercialization competence, innovation performance, and competitive advantage. The development of the research model takes on a dynamic-capability view and is based on empirical studies regarding competitive advantage. A survey of 103 export venture firms was conducted from January 5, 2015, to February 4, 2015. A partial least squares structural equation model is used to test the relationships between constructs set in the study. The results of the study show that the dynamic capability of an export venture firm has a significant positive influence on the firm's technology commercialization competence, innovation performance, and competitive advantage. The study also finds evidence that the export venture firm's technology commercialization competence directly affects its innovation performance and competitive advantage. In addition, the findings indicate that the innovation performance of an export venture firm has a significant positive impact on the firm's competitive advantage. Overall, these findings contribute to a better understanding of the contexts in which dynamic capability represents a specific capability for export venture firms.

  • PDF

Distributional Characteristics of Escherichia coli at Nakdong River Mouth and Busan Coastal Area (낙동강 하구와 부산연안해역에서 대장균의 해역별 분포특성)

  • Baek, Seung Ho;Lee, Min Ji;Yoon, Dongyoung
    • Journal of Marine Life Science
    • /
    • v.1 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • In order to assess seasonal and geographical characteristics of pollutant Escherichia coli, we investigated its distribution in Nakdong River mouth and Busan coastal water from February 2013 to November 2015. The coastal area was divided into five different zones (I-V) based on the pollutant level and geographical characteristics. During the study periods, water temperature and salinity varied from 7.50 to 27.64℃ and 16.82 to 34.82 psu, respectively. The annual water temperature variation was characterized in temperate zone. The salinity was significantly (p<0.05) decreased in zone IV and zone III after heavy rain during summer season in 2014, resulting led to elevated E. coli biomass. The highest colony formation of E. coli was recorded at 6,000 cfu l-1 during autumn at station 1 (zone I). On the other hands, during all seasons of 2015, E. coli abundances were kept to be low level in zone III. The E. coli was not significantly (p>0.05) correlated with water temperature. However, the salinity was significantly (r=-0.53, p<0.05) correlated with the E. coli, implying that salinity plays a crucial role in the proliferation of E. coli. Consequently, E. coli in western Busan coastal water might have been significantly promoted by pollutant sources from Nakdong Rive discharge during the spring and summer rainy seasons depending on annual rainfall variations. On the other hands, E. coli in station 1 (i.e., Suyeong Bay) was obviously high due to influences of discharge water from municipal wastewater treatment plant. However, there was no clear seasonality of E. coli.

Numerical modeling of tidal discharge through a permeable dyke from varying surface gradients (내·외 수위차를 이용한 투수성 제체의 조류량 모델링)

  • Hong, Seong Soo;Kim, Tae In;Nguyen, Thao Thi Hoang;Gu, Jeong Bon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.219-219
    • /
    • 2021
  • 서해안 중부 아산만 안쪽에 위치하는 평택·당진항에서 장래 개발 예정인 면적 6.9km2의 내항2공구 수역은 내항2공구 외곽호안 - 내항가호안 - 내항2공구 중앙 분리호안으로 둘러싸여 있으며, 투수성 제체인 내항가호안 사석 공극을 통하여 해수가 유통되어 조석 현상이 나타나고 있다. 2020년 8~9월의 2개월간 내항2공구 외곽호안 내·외측에서 조석 관측 결과, 2공구 수역의 최대 조차는 1.97m로서 외측 해역 최대 조차 9.79m의 20.1%이고 내·외측의 순간 수위차는 최대 5.82m에 달한다. 내항가호안은 내항2공구 개발이 거의 완료되는 시기까지 유지될 예정이므로 2공구 개발에 따른 내측 조차와 내·외측 수위차의 변화를 정확하게 예측하는 것은 내항가호안 제체 안전에 매우 중요하다. 이 연구의 목적은 장래 개발단계별 변화 예측에 앞서, 관측이 이루어진 2개월간의 실시간 내측 조석과 내·외측 수위차 시계열을 Delft3D-Flow를 이용하여 기 구축된 아산만 수치모델에서 재현하는 것이다. 내항가호안 제체 통과 유량은 내·외측 수위차에 비례하는 것으로 가정하고, 수위차 - 유량 관계식을 도출하였다. 수위차는 평택 조위관측소와 내항2공구 수역의 1분 간격 관측 조위로부터 산출하였고, 제체 통과 유량은 내측 조위(z, 평택항 DL 기준, m) - 수용적(V, 106m3) 관계식으로 계산하였다. 내측 조위 - 수용적 관계식은 수심측량 성과로부터 V = 0.28z2 + 3.73z + 2.96 (r2=1.00)으로 얻어졌다. 다양한 함수식의 적합성을 검토한 결과, 다음과 같은 수위차(𝚫z, m) - 제체 통과 유량(Q, m3/s) 관계식을 도출하였다. [내항가호안 내측으로 유입시] $Q_{IN}=\{\begin{array}{lll}{\exp}\{0.54\;{\ln}({\Delta}z)+6.00\}&&\text{; }{\Delta}z{\leq}1.8\\219.82{\Delta}z+158.56&&\text{; }{\Delta}z>1.8\end{array}\;\;(r^2=0.86)$ [내항가호안 외측으로 유출시] QOUT = -exp{0.44 ln(-𝚫z) + 5.70} (r2=0.59) 매 𝚫t 마다 제체 통과 유량을 계산하는 알고리즘을 Delft3D 소스 코드에 추가하고, 8개 분조 합성조석(M2, S2, K1, O1, N2, K2, P1, Q1)을 외력조건으로 설정하여 2개월간 조석 수치모델링을 수행하였다. 내항2공구 수역의 매 시별 조위 관측치와 모델치를 비교한 결과, 오차는 -0.37~0.37m의 범위이고, 오차 평균은 0.02m, 절대오차 평균은 0.08m로 상당히 정확하게 실시간 조위 변동을 모의하였다. 보정·검정된 이 모델을 이용하여 향후 내항2공구 개발에 따른 내측 조석과 내·외측 수위차 변화에 대한 예측모의를 진행할 예정이다.

  • PDF

Determination of itraconazole in human plasma by high performance liquid chromatography (HPLC/UV를 이용한 혈장 중 이트라코나졸의 분석)

  • Jang, Hae Jong;Lee, Ye Rie;Lee, Kyung Ryul;Han, Sang-Beom;Kang, Seung Woo;Lee, Hee Joo
    • Analytical Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.239-243
    • /
    • 2006
  • This method is used for the determination of itraconazole in human plasma by liquid-liquid extraction and high performance liquid chromatography. Felodipine was used as an internal standard. After extraction of the plasma with diethyl ether, the centrifuged upper layer was then transferred. The supernantant was evaporated and then reconsituted with mobile phase. The mobile phase was composed of 10 mM ammonium acetate adjusted to pH 7 by phosphoric acid with a flow rate of 0.2 mL/min. A C18 reversed-phase column with a pre-column was used as the analytial column. Linear detection responses were obtained for itraconzole concentration range for 2~1,000 ng/mL. The correlation coefficient of linear regression($R^2$) was 0.9991, limit of quantification (LOQ) was 2 ng/mL, reproducibility was less than 10.8 %, and accuracy was 97.2~108.2%. This method has been successfully applied to the pharmacokinetic study of itraconazole in human plasma.

Determination of lercanidipine in human plasma by LC-MS/MS (LC-MS/MS를 이용한 혈장 중 레르카니디핀의 분석)

  • Jang, Moon-Sun;La, Sookie;Chang, Kyu Young;Kang, Seung Woo;Han, Sang Beom;Lee, Kyung Ryul;Lee, Hee Joo
    • Analytical Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.34-40
    • /
    • 2008
  • Liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the quantitative determination of lercanidipine in human plasma. After addition of internal standard (amlodipine), plasma was precipitated with acetonitrile and the supernatant was evaporated. The residues were dissolved in 50 % acetonitrile and analyzed by LC-MS/MS. Using MS/MS with multiple reaction monitoring(MRM) mode, lercanindipine were selectively detected without severe interference from human plasma. The standard calibration curve for lercanidipine was linear (r = 0.9994) over the concentration range 0.05-20.0 ng/mL in human plasma. The intra- and inter-day precision over the concentration range of lercanidipine was lower than 11.7 % (correlation of variance, CV), and accuracy was between 94.4-114.8 %. This method has been successfully applied to the pharmacokinetic study of lercanidipine in human plasma.