• Title/Summary/Keyword: 변단면률

Search Result 29, Processing Time 0.024 seconds

Layered Section Analysis for PSC Girder with Variable Cross Section Using SI Technique (SI기법을 이용한 변단면 PSC 거더의 층상화 단면해석)

  • Kim, Byeong Hwa;Park, Taehyo;Jeon, Hye-Kwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.6A
    • /
    • pp.581-590
    • /
    • 2010
  • This study introduces a layered sectional analysis for a PSC girder with a vaiable cross section and curved tendons. To consider the shear equilibrium at a concrete layer with curved tendons, the shear stress distribution has been computed at each section. In addition, to improve the convergence to the solution, a system identification technique is newly adopted in the solution process for strain computation. To examine the feasibility of the proposed approach, a static load test has been conducted for a full scale PSC girder with variable cross section. The prediction shows a good agreement with experiment. It is seen that a uniform cross section has the same moment capacity with a variable cross section while the variable cross section has more shear capacity than the uniform cross section. It is also noted that the maximum displacement of a variable cross section is a little smaller than a uniform cross section.

Vibration Analysis of Plates with Openning about Variation Ratio (변단면률의 변화에 대한 개구부를 갖는 판의 진동해석)

  • Kim, Il-Jung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.1177-1180
    • /
    • 2007
  • This paper has the objects of deciding dynamic instability regions of thick plates by finite element method and providing kinematic design data for mats and slabs of building structures. In this paper, dynamic stability analysis of tapered opening thick plate is done by use of Serendipity finite element with 8 nodes considering shearing strain of plate. To verify this finite element method, buckling stress and natural frequencies of thick pate with or without in-plane stress are compared with existing solutions. The results are as follow that this finite element solutions with $4{\times}4$ meshes are shown the error of maximum 0.56% about existing solutions, and obtained dynamic instability graph according with variation of opening positions.

  • PDF

Moment Capacity of Reinforced Concrete Members Strengthened with FRP (FRP 보강 철근콘크리트 부재의 휨모멘트)

  • Cho, Baik-Soon;Kim, Seong-Do;Back, Sung-Yong;Choi, Eun-Soo;Choi, Yong-Ju
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.3
    • /
    • pp.315-323
    • /
    • 2010
  • Five concrete compressive stress-strain models have been analyzed to check the validity of the strength method for determining the nominal moment of strengthened members using commercially available computer language. The results show that the concrete stress-strain models do not influence on the flexural analysis. The moment of a strengthened member obtained from the flexural analysis at concrete compressive strain reaching 0.003 is well agreed with nominal moment using the strength method. The flexural analysis results show that when the steel reinforcement, FRP ratio, FRP failure strain, and concrete failure compressive strain are relatively lower, the strength method overestimates the flexural capacity of the strengthened members.

Evaluation of Leak Rate Through a Crack with Linearly-Varying Sectional Area (선형적으로 변하는 단면적을 가진 균열에서의 누설률 평가)

  • Park, Jai Hak
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.9
    • /
    • pp.821-826
    • /
    • 2016
  • The leak before break (LBB) concept is used in pipe line design for nuclear power plants. For application of the LBB concept, leak rates through cracks should be evaluated accurately. Usually leak late analyses are performed for through-thickness cracks with constant cross-sectional area. However, the cross-sectional area at the inner pipe surface of a crack can be different from that at the outer surface. In this paper, leak rate analyses are performed for the cracks with linearly-varying cross-sectional areas. The effect of varying the cross-sectional area on leak rates was examined. Leak rates were also evaluated for cracks in bi-material pipes. Finally, the effects of crack surface morphology parameters on leak rates were examined.

Design Wind Loads for Catwalk Structures (캣워크 구조물 설계 공기력 산정)

  • Lee, Han Kyu;Kim, Jong Hwa;Lee, Seung-Ho;Kwon, Soon-Duck
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.71-71
    • /
    • 2011
  • 캣워크는 현수교의 주케이블을 가설을 위해 일시적으로 설치하는 공중작업발판으로 주케이블 가설장비와 작업원 등의 하중을 지지한다. 캣워크는 유연한 구조물로서 풍하중에 상당한 변형이 발생한다. 하지만, 국내외를 막론하고 캣워크의 내풍안정성에 대한 연구는 별로 이루어지지 않았다. 거기에 더하여 캣워크에 작용하는 정적 공기력에 대한 정보도 부족하며, 현재 캣워크 단면에 대한 적절한 풍하중을 산정하지 못하고 경험적인 설계가 이루어지고 있다. 따라서 캣워크의 효율적인 내풍설계를 위하여 풍동실험을 통한 충실률과 공기력계수와의 관계를 알아보는 것이 필요하다. 이를 위하여 축척 1/4인 모형을 사용한 풍동실험을 통하여 메쉬망의 크기를 변화시키면서 충실률에 따른 공기력계수를 측정하고 설계식을 제안하고자 한다. 캣워크는 로프와 아울러 가는 철망으로 아래와 양 옆이 막혀 있다. 즉 바람을 직접 받는 부분인 철망은 가는 원형단면으로 구성되어 있다. 원형 단면의 경우에 레이놀즈 수에 따라 항력계수가 크게 변하는 것으로 알려져 있다. 그러나 가는 원형 단면으로 둘러싸인 캣워크의 항력계수에 레이놀즈 수가 미치는 영향에 대해서는 연구된 바가 없다. 본 연구에서는 캣워크의 공기력계수에 미치는 레이놀즈 수에 대한 영향을 파악하고자 1/4모형과 1/14모형을 제작하여 최대풍속 30m/s까지 변화시켜가면서 공기력계수를 측정하였다. 이때 레이놀즈 수는 최대 20배까지 차이가 나므로 만약 공기력계수가 레이놀즈 수의 영향을 받는다면 확실히 그 영향을 파악할 수 있다. 본 연구에서는 풍동실험을 통해 충실률과 공기력계수와의 관계과 레이놀즈 수의 영향을 살펴보았으며, 정적공기력 계수의 설계식을 제안하였다. 본 연구를 통하여 얻은 결과를 정리하면 다음과 같다. 1. 축척 1/14 및 1/4 모형을 사용하여 다양한 풍속에서 공기력계수를 측정한 결과, 캣워크에 작용하는 정적 공기력계수는 레이놀즈 수의 영향을 받지 않는 것으로 나타났다. 따라서 향후 새로운 형식의 캣워크에 대한 풍동실험을 수행할 경우에 축척에 상관없이 풍동실험 결과를 사용할 수 있을 것으로 판단된다. 2. 풍동실험 결과, 캣워크에 작용하는 정적 공기력계수 중 항력계수와 피칭모멘트계수는 측면 충실률에 따라 달라지고, 영각에 대한 양력계수의 기울기는 하부 충실률의 영향을 받는 것으로 나타났다. 그리고 주케이블이 캣워크 내부에 위치하고 있어도 캣워크의 정적 공기력계수에는 큰 영향을 미치지 않은 것으로 측정되었다. 이를 정리하여 캣워크 충실률에 따른 정적 공기력계수의 추정식을 제안하였다.

  • PDF

Flexural Analysis of Reinforced Concrete Members Strengthened with FRP Systems Based on Strength Method (FRP 시스템으로 보강한 철근콘크리트 부재의 휨 해석)

  • Cho, Baik-Soon;Kim, Seong-Do;Cheung, Jin-Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.2
    • /
    • pp.175-186
    • /
    • 2006
  • Strength method for determining nominal moment capacity of reinforced concrete members is also assumed to be suitable for strengthened members with FRP system. If the internal tensile forces of the strengthened member from steel and FRP is insufficient, the FRP system strain might become greater than its ultimate tensile strain which makes the strength method a contradiction and unapplicable. The experimental results of 27 strengthened beams with carbon fiber sheets which have relatively lower tensile forces from steel and FRP show that not only concrete compressive strain is lower than 0.003 but also measured ultimate moment was lower than nominal moment using the strength method.

Free Vibration Analysis of Stiffened Tapered Thick Plates with Concentrated Masses (집중질량을 갖는 변단면 보강 후판의 자유진동해석)

  • Lee, Yong-Soo;Kim, Il-Jung;Oh, Soog-Kyoung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.8
    • /
    • pp.828-837
    • /
    • 2009
  • Recently, as high-rise buildings increase steeply, sub-structures of them are often supported on elastic foundation(in a case of pasternak foundation or winkler foundation). And there are many machines in sub-structures of buildings and slabs of sub-structures are affected by vibration which they make. This paper deals with vibration of plates on elastic foundation. Machines on plates are considered as concentrated mass. This paper has the object of investigating natural frequencies of tapered thick plate on pasternak foundation by means of finite element method and providing kinetic design data for mat of building structures. Free vibration analysis that tapered thick plate with Concentrated Masses in this paper. Finite element analysis of rectangular plate is done by use of rectangular finite element with 8-nodes. In order to analysis plate which is supported on pasternak foundation. The Winkler parameter is varied with 10, $10^2$, $10^3$ and the shear foundation parameter is 5, 10. This paper is analyzed varying thickness by taper ratio. The taper ratio is applied as 0.0, 0.25, 0.5, 0.75, 1.0. And the Concentrated Mass is applied as P1, Pc, P2 respectively.

Vibration Analysis of Thick Plates with Concentrated Mass on Elastic Foundation (탄성지지된 집중질량을 갖는 변단면 후판의 진동해석)

  • Kim, Il-Jung;Oh, Soog-Kyoung;Lee, Yong-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.6 s.111
    • /
    • pp.609-618
    • /
    • 2006
  • This study is undertaken for the vibration analysis of tapered thick plate with concentrated mass on elastic foundation. The boundary condition of the plate is analyzed with the 4-sides simply supported and 4-fixed basis. This study find out the frequency following the change in size for each foundational variable on Pasternak foundation, one of the two-parameter elastic foundation parameter that considered the shear layer to the Winkler foundation parameter. The concentrated mass is applied with the consideration of mass of the entire plate, and the change of frequency is studies on each location with the consideration of reacting for the three locations for concentrated mass. And, in order to find out the change of frequency on the thickness of the plate, it considered tapered ratio that linearly changes depending on the length of the plate with the thickness of the plate in x-direction, and the tapered ratio has changes with 4 types ($\alpha$=0.25, 0, 5, 0.75, and 1.0). For the interpretation, the program using finite element method (F.E.M.) is used and the element coordination is used the 8-node serendipity element. Therefore, the purpose of this study is to find out the characteristics of plate vibration under the mechanica vibration or external vibration factor to facilitate as the basic data of the design to secure the stability.

Evaluation of Axial Strains of Reinforced Concrete Columns (철근콘크리트 기둥의 축방향 변형률 평가)

  • Lee, Jung-Yoon;Kim, Min-Ok;Kim, Hyung-Beom
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.1
    • /
    • pp.19-28
    • /
    • 2013
  • The longitudinal axial strain in the plastic hinge region of reinforced concrete (RC) columns influences on the structural behavior of RC structures subjected to reversed cyclic loading. This strain decreases the effective compressive strength of concrete and increases the lateral displacements between stories by causing the elongation of member length. This paper investigated the effects of the axial force on the elongation of a RC member by using a sectional analysis of RC members. The analytical and experimental results indicated that the axial force decreased the axial strain in the plastic hinge region of RC columns. In this study, a model was proposed to predict the axial strain of RC columns. The proposed model considering the effects of axial force ratio consisted of three path types ; Path 1-loading region, Path 2-unloading region, and Path 3-reversing cyclic loading region. The axal strains predicted by the proposed model were compared with the test results of RC columns with various axial force ratios, and agreed reasonably with the observed longitudinal strains.

Restraint Coefficient of Long-Term Deformation and loss Rate of Pre-Compression for Concrete (콘크리트 장기변형의 구속계수와 선압축력의 손실률)

  • 연정흠;주낙친
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.4
    • /
    • pp.521-529
    • /
    • 2002
  • A restraint coefficient for creep and dry shrinkage deformation of concrete in a composite section was derived to calculate the residual stress, and an equation for the loss rate of the pre-compression force was proposed. The derived restraint coefficient was computed by using the transformed section properties for the age-adjusted effective modulus of elasticity. The long-term behavior of complicate composite sections could be analyzed easily with the restraint coefficient. The articles of the current design code was examined for PSC and steel composite sections. The dry shrinkage strains of $150 ~ 200$\times$10^{-6}$ for the computations of the statically indeterminate force and the expansion joint could be under-estimated for less restrained sections such as the reinforced concrete. The dry shrinkage strain of $180$\times$10^{-6}$ for the computation of residual stress in the steel composite section was unreasonably less value. The loss rate of 16.3% of the design code for the PSC composite section in this study was conservative for the long-term deformation of the ACI 205 but could not be used safely for that of the Eurocode 2. For pre-compressed concrete slab in the steel composite section, the loss rate of prestressed force with low strength reinforcement was much larger than that with high strength tendon. The loss rate of concrete pre-compression increased, while that of pre-tension decreased due to the restraint of the steel girder.