• Title/Summary/Keyword: 벽식 구조

Search Result 155, Processing Time 0.036 seconds

System dentification of Apartment Buildings with Wall-Slab configuration using Modal Analysis (모드해석을 통한 벽식구조 아파트건물의 System Identification)

  • 장극관;천영수
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.4
    • /
    • pp.191-197
    • /
    • 1998
  • This paper described the dynamic characteristics of 20-story apartment buildings from the results of full-scale measurements and analysis. The natural frequencies and mode shapes are quantified by measuring and analyzing ambient vibrations of the structure and compared with the results from dynamic analysis. Comparison with computed mode shapes and frequencies shows good agreement with the experimental results. It proved that it is important to estimate coupling beam and soil parameters through a comparison of the measured results with calculated results.

  • PDF

A Study on the Development of Samsung Composite Shear Wall System (삼성의 벽식 구조 복합화 공법)

  • Park, Joon-Sung;Kim, Yeon-Kyeong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.2 no.2
    • /
    • pp.175-180
    • /
    • 2002
  • "Samsung Composite Shear Wall System" has its basis on "Samung Able System". "Samsung Able System" has some problems not only in the connection structure but also in waterproofing and soundproofing. We developed "Samsung Composite Shear Wall System" in order to solve these matters and expand PC system. "Samsung Composite Shear Wall System" is the compromise and complement of all the merits of full PC, half PC and in-situ concrete system.

Seismic Performance Evaluation of Damaged Apartment building (손상된 벽식 아파트 구조의 내진성능평가)

  • 김동영;장극관;서대원;천영수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.431-436
    • /
    • 2002
  • The purpose of this study is to evaluate resistance capacity of the damaged wall structural system against earthquake ground accelerations. Two lumped damage models(5 story, 12 story) are investigated by nonlinear time history analysis. As a result of analyses, the effect of stiffness degradation due to structural damages might change the interstorydrift of the structure. Therefore the increasing interstorydrift of damaged structures might be applied to evaluate the seismic performance of damaged structures.

  • PDF

Measurement of First Natural Frequency in Apartments with Shear Wall (벽식구조 아파트의 고유진동수 측정에 관한 연구)

  • 김하근;김흥식;천영수;김명준
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.1065-1069
    • /
    • 2001
  • This study aims to suggest the basic data for structural safety assessment and design considering building dynamic characteristics. For this purpose, ambient vibration measurement was practiced after studying international standards dealing with vibration measurements such as ISO, DIN and so on. Various types of situation and condition which help search the building natural frequencies through the field measurements were proposed.

  • PDF

Study of Inelastic Responses of a 1:12 Scale 10-Story R.C. Frame-Wall Structure (1:12축소 10층 R.C. 골조-벽식 구조의 비선형 거동 연구)

  • 이한선;김상호;유은진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.867-872
    • /
    • 2000
  • A 1:12 scale 10-story RC building structure was constructed and the experiment was performed. The test results are presented and compared with the results of the analysis conducted with DRAIN-2DX. It is concluded that some local deformations cannot be described reasonably with the wall model using only Plastic Hinge Beam-Column Element(TYPE02) in DRAIN-2DX whereas the strength and stiffness of the whole structure can be predicted with high reliability.

Displacement Based Seismic Design of Asymmetric-Plan Wall Structures (비대칭 벽식구조의 변위에 근거한 내진설계)

  • 조봉호;홍성걸
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.09a
    • /
    • pp.251-259
    • /
    • 2001
  • 본 논문은 직접 변위 설계법의 기본개념을 이용하여 비대칭 평면을 갖는 벽 식구조의 변위에 근거한 내진설계방법을 제안한다. 제안된 설계방법은 구조시스템의 각 벽체의 강도비와 강성비 및 목적 설계 변위를 결정하고, 직접 변위 설계법에 따라 설계하중은 구하는 과정으로 이루어진다. 탄성 영역에서는 강성 편심을, 비탄성 영역에서는 강도 편심을 주요한 설계변수로 사용하였다 성능에 기초한 내진설계의 개념에 따라 비대칭 평면을 갖는 구조물이 요구되는 성능 수준을 효과적으로 만족할 수 있도록 본 논문은 시스템의 비틀림 미케니즘과 각 벽체의 변형능력을 고려하였다. 제안된 설계방법을 이용하여 중진과 강진 지역에 대해 예제 구조물의 설계하중을 구하고, 최적의 설계방법을 제안하였다.

  • PDF

Behaviour of Shear Wall Structures with Energy Dissipation Device in Coupling Beam (연결보에 감쇠장치를 적용한 전단벽식 구조물의 거동특성)

  • Kim, Jin-Sang;Yoon, Tae-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.3
    • /
    • pp.21-30
    • /
    • 2018
  • Building structures of apartment in korea conventionally adopt shear walls using coupling beams as seismic force-resisting systems. Energy dissipating devices employed the building structures are used instead of the coupling beams in order to increase the seismic performances by providing additional damping and stiffness. This study aims to introduce energy dissipating devices which are preferred in structural system and aims to investigate structural behaviors of shear wall structures employing such devices instead of coupling beams. In order for achieve research objectives, Finite Element Analysis and Nonlinear analysis was carry out. Finite Element Analysis results was correspond with experimental results and this is indicated that the device can provide sufficient additional damping and stiffness into shear wall structures. Throughout nonlinear static analyses, examples structures with the devices can enhance seismic performance of building structures due to their sufficient energy dissipating capacities. Especially, strength and ductility capacities were significantly improved when it is compared with the performance of building structures without the devices. Throughout nonlinear dynamic analyses, it was observed that structural damages can be mitigated due to reduced seismic demands for seismic force-resisting systems. It is especially noted due to the fact that story drifts, accelerations, shear demands are reduced by 15~18%, 20~28% and 15~20%, respectively.

Elasto-plastic Earthquake Response Analysis of Beam-Shear Wall Structural System (보-전단벽식 구조 시스템의 탄소성 지진응답 해석)

  • 정명채;이정원
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.1
    • /
    • pp.57-67
    • /
    • 1997
  • The objective of present paper is to investigate elasto-plastic behaviour and estimate the resistance capacity of a beam-shear wall structural system against earthquake ground accleration exciations. Pushover analysis is adopted to estimate inttiate and post stiffnesses and yielding point for inelastic response analysis in LPM (Lumped Parameter Mass) model, and modified Clough model is used as the hysteresis rule of each story. Three earthquake waves are used in the analysis but their peak ground accelerations are changed to be 0.12g, 0.24g. It is assumed that the earthquakes act in the longigtudianl direction of a 25 Story apartment building which consists of two some unit plan. The distribution of story ratio and ductility ratio are estimated and discussed within Korean, Japanese code and UBC.

  • PDF

An Economic Analysis of Steel Framed Modular Housing: Compared with Case of Urban Type Living Housing of Wall-slab (강재 프레임 주택형 모듈러의 경제성 분석: 벽식구조인 도시생활형주택과의 사례비교를 통해)

  • Bang, Jong-Dae;Chun, Chu-Young;Park, Ji-Young;Kim, Jong-Yeob;Kim, Gap-Deug;Chun, Young-Soo
    • Land and Housing Review
    • /
    • v.5 no.4
    • /
    • pp.305-314
    • /
    • 2014
  • The technology-intensive unit modular method of factory production method is attracting attention by the limit of the labor-intensive and field centered wet construction method. In recent years, the unit modular method has been applied to the construction of schoolhouse and BOQ(bachelor offices' quarters), dormitories, etc. But the modular method still is not used in housing construction by the lack of verification of resident performance and construction cost. Therefore, this study analyzed the economics of modular house to vitalize the constructed residential building by modular method and to develop the modular method. According to the study results, the construction cost of the modular house was analysed more about 6.2% expensive than that of the existing housing. However, if the construction duration of modular house is shortened or the productivity of modular house is increased, the construction cost of modular house will be similar to the that of the existing house.

An Experimental Study on the Vertical Vibration Transfer according to Shear Wall Building Structures due to Exciting Vibration Forces (전단벽식 건축구조물의 수직진동 전달특성에 관한 실험연구)

  • Chun Ho-Min
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.159-166
    • /
    • 2005
  • The vibration on building structures due to exciting vibration forces has been studied only for the vibration level on existing buildings. Recently, several researches have been performed on the prediction of vertical vibration on structures by using an analytical method. However, these studies have been focused on mainly the vibration analysis through analytical modeling of structures. This study aims to investigate the characteristics of vertical vibration transfer in terms of the directions of transfer(upward transfer and downward transfer) on the shear wall building structures due to 2 type vibration forces. In order to examine the characteristics of vertical vibration transfer, the mode analysis and the impact experiment were conducted several times on one building structure. The results of this study suggest that the characteristics of vertical vibration transfer are different in terms of the directions of transfer.

  • PDF