• Title/Summary/Keyword: 법과실

Search Result 56, Processing Time 0.043 seconds

The Evaluation of Proficiency Test between Radioimmunoassay and Chemiluminescence Immunoassay (방사면역측정법과 화학발광면역측정법간의 숙련도 비교평가)

  • Noh, Gyeong-Woon;Kim, Tae-Hoon;Kim, Ji-Young;Kim, Hyun-Joo;Lee, Ho-Young;Choi, Joon-Young;Lee, Byoeng-Il;Choe, Jae-Gol;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.116-124
    • /
    • 2011
  • Purpose: To establish accurate external quality assurance (EQA) test, cross institutional and modality tests were performed using WHO certificated reference material (CRM) and same pooled patients serum. Materials and Methods: Accuracy and precision were evaluated using CRM and pooled patients' serum for AFP, CEA, PSA, CA 125, CA 19-9, T3, T4, Tg, TSH. To evaluate the accuracy and precision, recover test and coefficient variation were measured. RIA test were performed in major 5 RIA laboratory and EIA (CLIA) test were done in 5 major EIA laboratory. same sample of CRM and pooled serum were delivered to each laboratory. Results: In 2009, mean precision of total tumor marker of RIA was $14.8{\pm}4.2%$ and that of EIA(CLIA) was $19.2{\pm}6.9%$. In 2010, mean precision of 5 tumor marker and T3, T4, Tg, TSH was $13.8{\pm}6.1%$ in RIA and $15.5{\pm}7.7%$ in EIA (CLIA). There was no significant difference between RIA and EIA. In RIA, the coefficient variations (CV) of AFP, CEA, PSA, CA 125, T3, T4, TSH were within 20%. The CV of CA 19-9 was over 20% but there was no significant difference with EIA (CLIA) (p=0.345). In recovery test using CRM, AFP, PSA, T4, TSH showed 92~103% of recovery in RIA. In recovery test using commercial material, CEA, CA 125, CA 19-9 showed relatively lower recovery than CRM but there was no significant difference between RIA and EIA (CLIA). Conclusion: By evaluating the precision and accuracy of each test, EQA test could more accurately measured the quality of each test and performance of laboratory.

  • PDF

Comparison of Results According to Reaction Conditions of Thyroglobulin Test (Thyroglobulin 검사의 반응조건에 따른 결과 비교 분석)

  • Joung, Seung-Hee;Lee, Young-Ji;Moon, Hyung-Ho;Yoo, So-yoen;Kim, Nyun-Ok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.39-43
    • /
    • 2017
  • Purpose Thyroglobulin (Tg) is a biologic marker of differentiated thyroid carcinoma (DTC), produced by normal thyroid tissue or thyroid cancer tissue. Therefore, the Tg values of DTC patients is the most specific indicator for judging whether recurrence occur or whether the remaining thyroid cancer is present. Thyroid cancer is currently the most common cancer in Korea, of which 90% is differentiated thyroid cancer. The number of patients with thyroid disease of this application also increased, and an accurate and prompt results are required. However, the incubation time of the Tg commonly takes about 24 hours in our hospital, and the result reporting time is delayed, and We could not satisfied with the requirements of clinical departments and patients. In order to fulfill these requirements, experiments were conducted by shortening the incubation time between company B's Kit currently in use and company C's Kit used in other hospitals. Through these experiments, we could perform the correlation with the original method and shortening method, and could find the optimum reaction time to satisfy the needs of the departments and the patients, and we will improve the competitiveness with the EIA examination. Materials and Methods In September 2016, we tested 65 patients company B's kit and company C's kit by three incubation ways. First method $37^{\circ}C$ shaking 2hr/2hr, Second method RT shaking 3hr/2hr, Third method 1hr/1hr shaking at $37^{\circ}C$. Fourth method RT shaking 3hr method which is the original method of Company C's Kit. Fifth method, the incubation time was shortened under room temperature shaking 2hr, Sixth method $37^{\circ}C$ shaking 2hr. And we performed and compared the correlation and coefficient of each methods. Results As a result of performing shortening method on company B currently in use, when comparing the Original method of company B kit, First method $37^{\circ}C$ shaking 2hr/2hr was less than Tg 1.0 ng/mL and the ratio of $R^2=0.5906$, above 1.0 ng/mL In the value, $R^2=0.9597$. Second method RT shaking 3hr/2hr was $R^2=0.7262$ less than value of 1.0 ng/mL, $R^2=0.9566$ above than value of 1.0 ng/mL. Third method $37^{\circ}C$ shaking 1hr/1hr was $R^2=0.7728$ less than value of 1.0 ng/mL, $R^2=0.8904$ above than value of 1.0 ng/mL. Forth, Company C's The original method, RT shaking 3hr was $R^2=0.7542$ less than value of 1.0 ng/mL, and $R^2=0.9711$ above than value of 1.0 ng/mL. Fifth method RT shaking 2hr was $R^2=0.5477$ less than value of 1.0 ng/mL, $R^2=0.9231$ above than value of 1.0 ng/mL. Sixth method $37^{\circ}C$ shaking 2hr showed $R^2=0.2848$ less than value of 1.0 ng/mL, $R^2=0.9028$ above than value of 1.0 ng/mL. Conclusion Samples with both values of 1.0 ng/mL or higher in both of the six methods showed relatively high correlation, but the correlation was relatively low less than value of 1.0 ng/mL. Especially, the $37^{\circ}C$ shaking 2hr method of company C showed a sharp fluctuation from the low concentration value of 1.0 ng/mL or less. Therefore, we are planning to continuously test the time, equipment, incubation temperature and so on for the room temperature shaking 2hr method and $37^{\circ}C$ shaking 1hr/1hr of company C which showed a relatively high correlation. After that, we can search for an appropriate shortening method through additional experiments such as recovery test, dilution test, sensitivity test, and provide more accurate and prompt results to the department of medical treatment, It is competitive with EIA test.

  • PDF

Fully Automated Liquid Culture System Compared with Lowenstein-Jensen Solid Medium for Rapid Recovery of Mycobacteria in Sputums (완전 자동화된 액체배양법과 기존의 고체배양법을 이용한 객담 내 mycobacterium의 신속검출에 대한 비교)

  • Park, Seung-Kyu;Kim, Seung-Chul;Kim, Deuk-Mi;Lee, Chang-Woon;Kim, Young;Cho, Sang-Nae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.6
    • /
    • pp.635-643
    • /
    • 2002
  • Background : The Aim of this study was to compare the recovery of mycobacteria from sputum samples of pulmonary tuberculosis patients using the MB/BacT rapid culture system(Organon Teknika, USA) with that obtained using Lowenstein-Jensen solid medium. Methods : The two culture systems were compared using sputum samples of 99 pulmonary tuberculosis patients. Culture media were incubated at $35-37^{\circ}C$ for six weeks in the MB/BacT system and for 12 weeks in Lowenstein-Jensen solid medium. Solid media were examined macroscopically once a week, and the MB/BacT system positive vials were unloaded from the machine as soon as possible after positive signal from the connected computer was detected Confirmation of growth for mycobacteria was done by Ziehl-Neelson stained smears. Isolates were identified to differentiate Mycobacterium tuberculosis from mycobacterium other than tuberculosis(MOTT) by phenotypic and molecular methods. Results : Of the sputum samples of the 99 patients, 58 samples were smear positive and 41 in negative smear. Mycobacteria were recovered from 67(67.7%) samples by using both culture systems. The yield with MB/BacT was higher than that with Lowenstein-Jensen [67(67.7%) vs. 52(52.5%), p<0.001]. Moreover, 15(15.2%) samples were positive only in the MB/BacT, whereas none of samples was positive only in Lowenstein-Jensen. In smear-positive and smear-negative samples, the recovery rate with MB/BacT was also higher than that with Lowenstein-Jensen [sputum-positive; 56/58(96.6%) vs. 46/58(79.3%), p=0.005, sputum-negative; 6/41(14.6%) vs. 5/41(12.2%), p<0.001]. The mean times to detection of Mycobacteria were 13.3 and 27.2 days with MB/BacT and Lowenstein-Jensen respectively(p<0.001). Conclusion : This results indicate that the the MB/BacT is more efficient and faster than Lowenstein-Jensen for the recovery of mycobacteria.

Research on the Circumstance for Agricultural Investment of Cambodia (캄보디아 농업투자 환경에 관한 연구)

  • Lee, Kyu-Seong;Bae, Dong-Jin;Kim, Seong-Nam;Kang, Young-Shin
    • Journal of the Korean Society of International Agriculture
    • /
    • v.23 no.5
    • /
    • pp.475-484
    • /
    • 2011
  • International price of cereal has been dramatically increasing for the past few years. This price hike amplified the importance of food self-sufficiency in numerous countries due to the fact that food security is directly proportional to food self-sufficiency. In this study, we conducted a survey to provide useful information of Cambodia's agricultural environment to possible Korean agricultural investors and as to highlight Cambodia as a strong candidate for the establishment of Korea's foreign base for cereal production. The survey conducted includes information regarding Cambodia's agricultural environment and investment circumstances including the political, economical and other contributing factors affecting agricultural investment in Cambodia. Seventy percent of the Cambodia's total population engage in agriculture and this comprises about 30% of the country's GDP. This statistics reflects the possibility of Cambodia's poverty alleviation which proves that agriculture in Cambodia is the driving force for the improvement of the country's economy. In addition, low labor cost, fertile land, abundant water resources, like the Tonle sap lake and the Mekong river, and unreclaimed lands are the strong points that could attract agricultural investors to Cambodia. Poor infrastructure, irrigation systems, law reforms, including social and cultural differences may be the biggest setbacks for the acceleration of Cambodia's agriculture development. However, the Cambodian government is open and willing to make adjustments for Cambodia to be both foreign and domestic agricultural investor-friendly, expecting that it will boost its country's agricultural development. Making the best out of this opportunity, the coordination of KOICA with Korean agricultural investors in building infrastructures and with the help of the KOPIA program for the transfer of agricultural technology will benefit both countries and will play an important role in Cambodia's agriculture.

Application and Comparative Analysis of River Discharge Estimation Methods Using Surface Velocity (표면유속을 이용한 하천 유량산정방법의 적용 및 비교 분석)

  • Jae Hyun, Song;Seok Geun Park;Chi Young Kim;Hung Soo Kim
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.2
    • /
    • pp.15-32
    • /
    • 2023
  • There are some difficulties such as safety problem and need of manpower in measuring discharge by submerging the instruments because of many floating debris and very fast flow in the river during the flood season. As an alternative, microwave water surface current meters have been increasingly used these days, which are easy to measure the discharge in the field without contacting the water surface directly. But it is also hard to apply the method in the sudden and rapidly changing field conditions. Therefore, the estimation of the discharge using the surface velocity in flood conditions requires a theoretical and economical approach. In this study, the measurements from microwave water surface current meter and rating curve were collected and then analyzed by the discharge estimation method using the surface velocity. Generally, the measured and converted discharge are analyzed to be similar in all methods at a hydraulic radius of 3 m or over or a mean velocity of 2 ㎧ or more. Besides, the study computed the discharge by the index velocity method and the velocity profile method with the maximum surface velocity in the section where the maximum velocity occurs at the high water level range of the rating curve among the target locations. As a result, the mean relative error with the converted discharge was within 10%. That is, in flood season, the discharge estimation method using one maximum surface velocity measurement, index velocity method, and velocity profile method can be applied to develop high-level extrapolation, therefore, it is judged that the reliability for the range of extrapolation estimation could be improved. Therefore, the discharge estimation method using the surface velocity is expected to become a fast and efficient discharge measurement method during the flood season.

The Ultimate Bearing Capacity and Estimation Method of Rigid Pile for Port Structures under Lateral Load (횡하중이 작용하는 항만구조물에서 짧은말뚝의 극한지지력 및 평가방법)

  • Kim, Byung-Il;Han, Sang-Jae;Kim, Jong-Seok;Kim, Do-Hyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.1
    • /
    • pp.75-91
    • /
    • 2014
  • In this study the analysis is performed for influencing factors on the behavior of rigid piles (short pile) by research papers and case study. The results indicated that the point of virtual fixity should be calculated considering the relative stiffness of soil and pile, and Chang (1937) and P-Y method estimated the similar fixity. The values of ultimate resistances of a vertical pile to a lateral load are different for laboratory and field tests in cohesive soils and its ultimate values in laboratory tests are underestimated and in field tests are under or overestimated. The estimated resistance by Hansen (1961)'s method is similar to the value of field tests. The horizontal resistances to laterally loaded pile in cohesionless soils are overestimated in laboratory tests and generally overestimated in field tests. The ultimate resistances by Zhang (2005)'s method, used to the empirical distribution of the resistance, are similar to the test results. In the paper the calculating method and distribution of the ultimate resistance in cohesive soils are proposed. The estimated value by the proposed method is closer to the test results than any other method of calculating ultimate resistance of the piles embedded into cohesive soils.

Antioxidative Activity of Zinc-Enriched Saccharomyces cerevisiae FF-10 in In vitro Model Systems (아연-고함유 효모 Saccharomyces cerevisiae FF-10 세포액의 항산화효과)

  • Cha, Jae-Young;Park, Bo-Kyung;Ahn, Hee-Young;Eom, Kyung-Eun;Jun, Bang-Sil;Cho, Young-Su
    • Journal of Life Science
    • /
    • v.19 no.2
    • /
    • pp.179-184
    • /
    • 2009
  • Zinc is an essential trace element for human and plays an important biological role in antioxidant properties. We have been reported that zinc-enriched S. cerevisiae FF-10 contained 392 mg% in the YM basal and 3,193 mg% in the YM optimal medium. Antioxidative activity of FF-10 was tested in vitro models by DPPH (${\alpha},{\alpha}'$-diphenyl-${\beta}$-picrylhydrazyl) radical scavenging activity and lipid peroxidation using linoleic acid (LA) and rat liver homogenate. DPPH radical scavenging activity was higher in the cell-free extract of FF-10 cultured in the YM optimal medium (YMOM) than that in the YM basal medium (YMBM). The inhibition activity of lipid peroxidation using rat liver homogenate was shown in the following order: BHT > YMOM > YMBM and these values were dose dependently. The lipid peroxidation of the control mixture by ferric thiocyanate and TBA methods using LA was increased rapidly as typical peroxidation curve of LA from one day and the antioxidation activity of the cell free extracts by cultivating FF-10 in the YMOM were higher than that of the YMBM. Result of this study indicate that the cell-free extracts containing a high intercellular zinc of S. cerevisiae FF-10 cultured in YMOM showed strong antioxidation capacities in DPPH radical scavenging activity and lipid peroxidation using LA and rat liver homogenate.

Studies on the Changes of Lipid Constituents during Gulbi Processing (굴비제조중 지방질성분 변화에 관한 연구)

  • Park, Young-Hee;Song, Eun;Shin, Mal-Shick;Jhon, Deok-Young;Hong, Youn-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.485-491
    • /
    • 1986
  • Gulbi were made by salting fresh Yellow corvenia (Pseudosciaena manchurica) in three ways; the dry salting method with bay-salt, the dry salting method with purified salt or the abdominal brine injection method with purified salt. Half of the sample was dried by controlling temperature and relative humidity and the other part was dried under the natural condition. The moisture content of the samples were decreased more rapidly by the controlled system than by the natural condition. The lipid content and the iodine values of the muscle and skin of the Gulbi were decreased slowly with laps of drying period. The peroxide values of the sample were increased to its peak after 10 days of drying, and were decreased rapidly thereafter. Both acid values and the thiobarbituric acid values were increased. The deterioration of lipids during Gulbi processing was not notable depending on the salting method, but the natural drying condition affected more severely in their deterioration.

  • PDF

Evaluation of Automated ESR Measuring System, $SEDIsystem^{TM}$ ($SEDIsystem^{TM}$을 이용한 적혈구 침강속도 측정의 평가)

  • Lee, Jung-Ee;Kim, Kyung-Dong;Lee, Chae-Hoon;Kim, Chung-Sook
    • Journal of Yeungnam Medical Science
    • /
    • v.13 no.1
    • /
    • pp.110-115
    • /
    • 1996
  • The ESR is one of the oldest laboratory test still in use. Although it lacks specificity in diagnosis, it can be effective for monitoring disease activity and following-up. The Westergren method is used for reference method, however coefficient of variation has been described 0.8% to 22.9% according to the literature. Since the ESR was invented in 1921, measurement technique has developed and automated measurement is introduced. We analyzed one hundred forty-three patient samples using $SEDIsystem^{TM}$ automated ESR measuring system and compared with modified Westergren and Wintrobe methods. Comparison between $SEDIsystem^{TM}$ and modified Westergren for ESR measurement yields the following regression equation; y = 0.863x - 1.69 (r=0.830), $SEDIsystem^{TM}$ and Wintrobe y = 1.14x - 14.7 (r=0.789), respectively. We repeated measurement to evaluate reliability, results are not significant in statistically. In conclusion, $SEDIsystem^{TM}$ automated ESR measurement correlated with modified Westergren and Wintrobe methods, reveal reliable results after 4 hours and can report rapidly for large samples. Thus, these results indicate that $SEDIsystem^{TM}$ automated ESR measurement may be useful tool for clinical practice.

  • PDF

An experimental study on the dynamic teeth movement of 3 types of the insertion method of Precision-TPA for derotating the posterior teeth (Precision-TPA를 이용한 구치부 회전시 근심 및 원심삽입법에 따른 동적인 치아이동 양상에 관한 실험 연구)

  • Yang, Sung-Jae;Jung, Seong-Gweon;Row, Joon;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.29 no.4 s.75
    • /
    • pp.425-433
    • /
    • 1999
  • Dr. Youn-Sic Chun and coworkers invented the new machine for getting information about the relative effectiveness of the orthodontic appliances and we named it Calorific machine. The author and colleagues used this machine to compare with tooth moving mechanism by 3 types of the insertion method of precision-TPA for derotating the posterior teeth. We measured the distance of tooth movement and found out the rotational center on the occlusal X-ray film and the tooth movement on the occlusogram and then processed paired t-test by SAS program, The results were as follows : 1. In the intermolar width, the mesial insertion method showed the loss oi distance, and the other methods(-distal insertion method, mesial expansion method-) showed the increase of distance. 2. In the arch length, the distal insertion method was exhibited as most recommandable way for increasing the arch length .3. The rotation center of the mesial insertion method for derotating the molar, was located between mesial pit and central pit of the lower End molar. And, in the distal insertion method, it was located between distal pit and distolingual cusp, and in the mesial expansion method was located at distal pit.

  • PDF