• Title/Summary/Keyword: 배열 검사

Search Result 206, Processing Time 0.037 seconds

A Study on Applying Array Probe for Steam Generator Tube Inspection (배열형 탐촉자를 이용한 증기발생기 세관 검사 적용성 검토)

  • Kim, In Chul;Cheon, Keun Young;Lee, Young Ho
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.5 no.1
    • /
    • pp.25-31
    • /
    • 2009
  • Steam Generator(SG) tube is an important component of Nuclear Power Plant(NPP), which comprises of the pressure boundary of primary system. The integrity of SG tube has been confirmed by the eddy current test every outage. In Korea, Bobbin probe and MRPC probe have been generally used for the eddy current test. Meanwhile the usage of Array probe has gradually increased in U.S., Japan and other countries. In this study, we investigated the defect detection capability of the Array probe through its preliminary application to SG tube inspection. The Array probe has the equivalent capability in the defect detection and sizing as the conventional methods. Thus it is desirable that the Array probe is generally applied to SG tube inspection in the domestic NPPs.

  • PDF

A Development of diagonostic technique for generator rotor wedge by phased array UT (발전기 회전자웨지 위상배열 초음파진단 기법)

  • Cho, Yong-Sang;Mun, Kyeong-Hee;Kong, Tae-Shik
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.902-903
    • /
    • 2011
  • 발전설비에 대한 비파괴 검사 기술은 발전소 운전 신뢰성 및 안전성 유지확보 그리고 건전성을 보장하기 위한 필수적인 기술이다. 이 설비 중 터빈, 보일러 등 주요 발전설비에 대한 초음파 검사는 매우 신중하고 정확하게 검사할 필요성이 있으나, 일반적 초음파 검사방법으로는 불가능한 부분이 많고 일부분에 대해서는 이를 외국 제작사 기술용역에 의존하고 있는 실정이다. 특히 발전기 로타 웨지와 같이 재질상 감쇄가 심한 재료에 대해서는 검사 자체가 어렵고, 지금의 초음파 검사 방법으로는 결함의 크기나 형태를 파악하기도 어려워 이에 대한 개선책이 시급한 실정이다. 최근에 개발이 시작된 Phased Array UT분야는 발전설비중 접근자체가 어렵고, 형상이 복잡하여 결함의 탐지 및 평가가 힘든 부분에 적용하면 검사신뢰도 및 신속성을 향상시킬 수 있으며 접근성에 대한 제한 또한 감소시킬 수 있다. 따라서 본 논문은 발전기 부품에 발생하는 일반적인 결함에 대하여 Phased array UT 기술을 도입하여 신호의 특성을 분석하는 결과평가에 도음이 되고자 하였다.

  • PDF

The Implementation of Inspection Information Tube Happing Program for Nuclear Power Plant Facility (원전 설비 검사정보 세관 Mapping프로그램 구현)

  • 신진호;송재주;이봉재
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2001.10b
    • /
    • pp.238-240
    • /
    • 2001
  • 원자력발전소에서는 기기, 배관 및 각종 지지구조물 등 설비에 대하여 시간의 경과에 따른 취약화 정도를 측정하기 위하여 대략 15개월을 주기로 호기별 비파괴검사로 감시 및 평가하는 가동중검사를 실시한다. 증기발생기, 주복수기와 같은 세관으로 구성된 설비는 와전류탐상검사를 수행하여 신호데이터를 취득하고 건전성 여부를 평가한 다음 그 결과를 Optical Disk에 신호데이터와 함께 저장한다. 본 논문에서는 저장된 방대한 양의 검사 결과 파일을 추출하여 데이터베이스로 구축하고, 행열 수량, 모양, 방향 및 열번호 부여방법이 상이한 다양한 배열 형태의 세관 Map을 편집하여 사용자 요구에 따라 검사정보를 색상 Tube로 Mapping 처리하여 세관의 상태, 검사이력, 결함성장률 및 변화추이 분석을 시각적으로 파악할 수 프로그램 구현 사례를 소개한다.

  • PDF

Analysis of Defect in CANDU Feeder Pipe using Phased Array Ultrasonic Inspection System (냉각재 공급자관 위상배열 검사 적용에 따른 결함 분석)

  • Lee, Sang-Hoon;Jin, Seuk-Hong;Kim, In-chul
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.1
    • /
    • pp.78-82
    • /
    • 2010
  • The feeder pipe of Main Primary Heat Transfer System in Wolsong Nuclear Power Plant was inspected by the Ultrasonic Phase Array technique in 2010. It is the first time to apply this method to the construction at Nuclear Power Plant in Korea. The time required for UT technique is less than RT method. The UT method doesn't need to evacuate personnel who works nearby inspecting area and doesn't need to wait developing of film. For these reasons, the UT method is the fastest method among the volumetric inspections. As a result of the examination, it became clear that main defect of the feeder pipe is the Lack of fusion in the welded area. Moreover, the rate of defect was reduced gradually as improvement of welder's skill. If welding machine has problem, the defect has tended to same pattern(occurred same position in the welding area) but these defects were founded without specific rules. For these reasons, the creation of defect is dependent on the skill of worker not on the automatic welding machine. This evaluation of defect signal and collecting data would be useful to further examination in ISI.

  • PDF

Development of Crack Examination Algorithm Using the Linearly Integrated Hall Sensor Array (선형 홀 센서 배열을 사용한 결함 검사 알고리즘 개발)

  • Kim, Jae-Jun;Kim, Byoung-Soo;Lee, Jin-Yi;Lee, Soon-Geul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.11
    • /
    • pp.30-36
    • /
    • 2010
  • Previous researches show that linearly integrated Hall sensor arrays (LIHaS) can detect cracks in the steel structure fast and effectively This paper proposes an algorithm that estimates the size and shape of cracks for the developed LIHaS. In most nondestructive testing (NDT), just crack existence and location are obtained by processing 1-dimensional data from the sensor that scans the object with relative speed in single direction. The proposed method is composed with two steps. The first step is constructing 2-dimensionally mapped data space by combining the converted position data from the time-based scan data with the position information of sensor arrays those are placed in the vertical direction to the scan direction. The second step is applying designed Laplacian filter and smoothing filter to estimate the size and shape of cracks. The experimental results of express train wheels show that the proposed algorithm is not only more reliable and accurate to detecting cracks but also effective to estimate the size and shape of cracks.

A Study on Multiplication Expression Method by Visual Model (시각적 모델에 따른 곱셈식 표현 방법에 대한 연구)

  • Kim, Juchang;Lee, Kwnagho
    • Education of Primary School Mathematics
    • /
    • v.22 no.1
    • /
    • pp.65-82
    • /
    • 2019
  • In this study, students' multiplication expression method according to visual model was analyzed through paper test and eye tracking test. As a result of the paper-pencil test, students were presented with multiplication formula. In the group model (number of individual pieces in a group) ${\times}$ (number of group) in the array model (column) ${\times}$ (row), but in the array model, the proportion of students who answered the multiplication formula in the (row) ${\times}$ (column). From these results, we derived the appropriate model presentation method for multiplication instruction and the multiplication expression method for visual model.

A Development of an Array Guided Wave Ultrasonic Testing System for pipe inspection (배관 진단을 위한 배열형 유도초음파 검사시스템 개발)

  • Cho, Hyun-Joon;Lee, Dong-Hoon;Kang, To;Park, Jin-Ho;Han, Seong-Jin
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.5
    • /
    • pp.29-35
    • /
    • 2015
  • Pipes, commonly used in energy and petrochemical facilities, have various types of defects induced by diverse factors and this is often issued in NDE society. Ultrasonic guided wave inspection method are normally adopted to insure the healthiness of industry pipes. Recently, ultrasonic guided wave inspection is shifted to adopt arrayed probes and system. And here we developed an array guided wave ultrasonic testing system can adapt arrayed probes and focusing methods. In this paper, an array guided wave ultrasonic testing system is presented including a transmitting focusing technique and flaw signal level enhancement.

A Study on the Cross Talk Level in a Medical Piezoelectric Ultrasonic Array Transducer (의료용 압전 초음파 배열 변환기의 음향간섭 레벨에 관한 연구)

  • Kim Young-Shin;Roh Yongrae
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.349-352
    • /
    • 2002
  • 초음파 진단용으로 널리 사용되는 1차원 배열 압전형 초음파 변환기는 변환기내의 인접한 소자들간의 간섭에 의해 그 특성에 많은 영향을 받는다. 특히 각 소자 사이에 위치한 커프 및 음향 벽의 형상은 변환기 내 음향 간섭에 매우 큰 영향을 미친다. 그러므로 본 연구에서는 일반적으로 복부진단용으로 사용되는 압전형 1차원 배열 의료용 초음파 변환기에서 커프 및 음향 벽의 형상에 따른 음향간섭 레벨의 변화 경향을 유한 요소 해석법을 이용하여 분석하였다. 해석 결과를 바탕으로 소자간 음향간섭을 일으키는 원인을 규명하고, 나아가 음향 간섭레벨을 최소화하기 위한 구조적 방안을 도출하였다. 이러한 연구 결과는 향후 진단용 초음파 변환기의 최적 설계를 위해 중요한 자료가 될 것이며, 의료 치료용, 비파괴 검사용, 그리고 수중 초음파 변환기에도 적용이 가능할 것이다.

  • PDF

A Case of Transcortical Sensory Aphasia Assessed with Analysing the Patient's Speech at the Series of Pictures (이야기배열그림 발화분석을 통해 살펴본 초피질감각실어증환자 치료경과 1례(例))

  • Yoo, Gyung;Kim, Lak-Hyung;Jeong, Eun-Hee
    • Journal of Oriental Neuropsychiatry
    • /
    • v.16 no.2
    • /
    • pp.251-257
    • /
    • 2005
  • In this case study, We treated a transcortical aphasia patient with herbal medicine, acupunture and language therapy. We assessed the progress of the patient with Western Aphaia Battery(K-WAB), Boston Naming Test(BNT) and analysed the patient's speech at the series of pictures. The score of K-WAB and K-BNT was improved, the rate of statement at the theme of the picture was improved and the neologistic and verbal paraphasia was reduced. We think that the analysing the speech of the patient at the series of pictures to evaluate the practical problem of the patient would be useful. Further study is necessary about the utility of this assessment tools.

  • PDF

Nondestructive Inspection of Steel Structures Using Phased Array Ultrasonic Technique (위상배열 초음파기법을 이용한 강구조물의 비파괴 탐상)

  • Shin, Hyeon-Jae;Song, Sung-Jin;Jang, You-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.6
    • /
    • pp.538-544
    • /
    • 2000
  • A phased array ultrasonic nondestructive inspection system is being developed to obtain images of the interior of steel structures by modifying a medical ultrasound imaging system. The medical system consists of 64 individual transceiver channels that can drive 128 array elements. Several modifications of the system were required mainly due to the change of sound speed. It was necessary to fabricate array transducers for steel structure and to obtain A-scan signal that is necessary for the nondestructive testing. Boundary diffraction wave model was used for the prediction of radiation beam field from array transducers, which provided guidelines to design array transducers. And a RF data acquisition board was fabricated for the A-scan signal acquisition along a selected un line within an image. For the proper beam forming in the transmission and reception for steel structure, delay time was controlled. To demonstrate the performance of the developed system and fabricated transducers, images of artificial specimens and A-scan signals for selected scan lines were obtained in a real time fashion.

  • PDF