• Title/Summary/Keyword: 배관유동

Search Result 230, Processing Time 0.04 seconds

A Study on On-site Discharge Testing for Carbon Dioxide Fire Extinguishing Systems (이산화탄소 소화설비 현장 방출시험 방법론에 관한 고찰)

  • Park, Jun-Hyun;Kang, Tae-Seok;Kim, Jae-Hwan;Kim, Wee-Kyong
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.26-32
    • /
    • 2015
  • Carbon dioxide principally extinguishes fires by smothering, but an acceptable amount of extinguishing agent is needed. To assure the performance of carbon dioxide systems in Korea, computer programs certified by NEMA are being applied in system design. But the design errors can occur because the geometry of a model test facility is not the same as that of the actual fire area. Since the discharge rate tends to vary considerably with the flow pattern in a pipe, an on-site discharge test is necessary to ensure the performance of the system, especially with low pressure carbon dioxide. Technical standards for carbon dioxide systems do not give detailed guidelines for discharge tests at present. Based on comparative analysis of standards and practical tests, this paper suggests a methodology for on-site discharge tests.

Hight Efficiency Gasification of Biomass and Tar Reduction by Waste Metal (폐금속을 이용한 바이오매스의 고효율 가스화 및 타르 발생량 저감)

  • Sung, Hojin;Horio, Masayuki
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.179.2-179.2
    • /
    • 2011
  • 바이오매스 가스화 프로세스 개발에 있어서 가장 기본적인 해결과제는 고발열량의 합성가스 제조, 냉가스 효율의 향상, 타르 발생량 저감 및 제거이다. 가스화 효율 향상에 대한 연구는 국내외 적으로 많이 이루어지고 있으나, 타르 발생량 저감에 대한 연구는 많이 이루어져 있지 않다. 타르는 분자량이 큰 방향적 탄화수소로 응축되면 점성이 높아 배관폐쇄, 정제설비의 압력손실 증가로 인해 운전정지 및 가스화율 저하의 원인이 된다. 가스화로에서 타르 발생량을 저감시키는 방법 중에는 Ni계 촉매를 이용하는 방법이 있으나, 카본 누적에 의한 활성저하, 알칼리금속에 의한 응집 등의 문제가 발생할 수 있다. 한편 철산화물은 합성가스 중의 C2-C3계의 타르를 분해하는데 효과가 알려져 있다. 따라서 본 연구에서는 적벽돌, 염색슬러지 회재 등에는 철산화물이 다량 함유되어 있는 것에 착안하여 폐기물중의 폐금속을 이용한 바이오매스 가스화에 대한 연구를 수행하였다. 점토광물계 폐기물인 적벽돌 파쇄물($SiO_2$ 67.2%, $Al_2O_3$ 19.7%, $Fe_2O_3$ 8.7%, $K_2O$ 2.0%, $TiO_2$ 1.2%, MgO 0.7%)을 전처리 한 후 유동매체로하여 우드펠렛을 가스화한 결과, 가스 생성량이 증가하고, 타르 및 탄화수소류가 감소하는 경향을 나타내었다. 특히 타르는 후단의 타르 트랩에서 타르가 거의 검출이 되지 않았다. 전처리를 하지 않은 적벽돌 파쇄물은 반응시간이 경과한 후에 가스화율이 증가함에 따라 철화합이 가스화로내에서 환원되어 타르를 분해하는데에는 어느 정도의 반응시간이 필요한 것을 확인하였다.

  • PDF

The Prediction of Stratified Flow Pattern in a Variable Tube Inclinations and Gravity Conditions (다양한 배관 경사각도 및 중력조건에서의 층상류 유동양식 예측)

  • Choi, Bu-Hong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.14 no.4
    • /
    • pp.339-345
    • /
    • 2008
  • The stratified flow can be seen in the oil and gas pipelines as well as pipelines related to ship's fluid machineries. Numerous theories and correlations have also been proposed in the past for the prediction of stratified flow in horizontal or slightly inclined pipe. The previous researches are mostly about the effects of physical properties, viscosity, phases densities and pipe geometries on the stratified flow. Very few study outcomes exist on the effect of gravity magnitude and large slop angle of pipe inclinations on the occurring condition of stratified flow. In this study, therefore, analytical procedures were conducted about the effect of both the change in the gravity magnitude and pipe inclinations on the stratified flow occurring conditions. From the analytical results, it was found that stratified flow occurred at the vertical upward inclination and at very low liquid phase flowrates in 0.17g and 0.33g conditions.

  • PDF

Analysis of Dynamic Characteristics of Pneumatic Driving Solenoid Valve (공압구동용 솔레노이드밸브의 동특성 해석)

  • Jang, Je-Sun;Kim, Byung-Hun;Han, Sang-Yeop
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.731-736
    • /
    • 2011
  • A pneumatic driving solenoid valve operates pneumatic control devices by opening/closing operating flow passage when the command is given by control system for the liquid-propellant feeding system of space launch vehicle. The simulation model of pneumatic driving solenoid valve is designed with AMESim to verify the designs and evaluate the dynamic characteristics and pneumatic behaviors of valve. To validate a valve simulation model, the simulation results of their operating durations of valve by AMESim analysis are compared with the results of experiments. In addition, the results of internal flow simulation with FLUENT are utilized to improve the accuracy of valve-modeling. Using the model, we analyze performance of valve; opening/closing pressure, operating time on various design factors; shape of control valve seat, drainage seat, rate of sealing diameter, volume of control cavity. This study will serve as one of reference guides to enhance the developmental efficiency of ventilation-relief valves with the various operating conditions, which shall be used in Korea Space Launch Vehicle-II.

  • PDF

CFD analysis of CO detecting device in household gas boiler (가정용 가스 보일러 CO발생 검지 장치 전산해석)

  • Hwang Jae-Soon;Park Ju-Won;Shin Dong-Hoon;Chung Tae-Yong;Chae Jae-Ou;Choi Kyung-Suhk
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2006.05a
    • /
    • pp.164-169
    • /
    • 2006
  • 본 연구는 가정용 가스 보일러의 배기가스 유동특성을 전산유체역학을 이용하여 정밀 분석하고 CO 검지 장치의 최적화 설계를 결정하는 것을 목적으로, CFD 상용코드 FLUENT 6.2를 이용하였다. 배기가스 포집위치에서 가스 유속의 균일성과 CO농도 검출기에서의 속도가 주요 성능 인자이며 포집기의 위치, 포집구멍의 크기 및 배기가스의 유량을 주요 변수로 선택하였다. 포집기의 위치는 배기부의 상부와 하부인 두가지의 경우이고 두 경우의 배관 높이 차이는 10 mm이다. 포집구멍의 직경 변화는 3 mm, 4 mm 및 5 mm인 세가지 경우이다. 마지막 변수인 배기가스의 유입속도는 20,000 kcal/hr용량의 k사 가스 보일러가 공기비 1.1일 경우에 정상 연소시 0.5 m/s임을 알았고 저부하와 고부하일 경우를 고려해서 0.3 m/s, 0.5 m/s 및 0.7 m/s의 세가지 경우를 변수로 결정하여 총 18가지 형태의 대상을 전산유체 역학을 통해서 분석하였다. 궁극적인 목표였던 배기가스의 균일성은 한가지 경우를 제외 하고는 만족할만한 결과를 얻었기 때문에 CO검지 장치가 위치할 곳에서의 속도 및 포집구멍의 크기가 CO농도 검출기 유속의 주요 인자라 할 수 있다. 결론적으로 포집구멍의 크기가 5 mm인 6가지 경우 중에서 두가지 경우는 검지장치의 유효속도를 초과하였고 포집구멍의 크기가 3 mm인 경우는 검지장치의 유입 속도가 상대적으로 작으므로 포집구멍의 크기는 4 mm가 적합한 것으로 판단하였다.

  • PDF

A Study on the Visualization of Ice-formation Phenomena of Bath Water to Decide Maintenance Period of Gas Heater (가스히터 보수주기 결정을 위한 히터내부 열전달 매체액 결빙현상 가시화에 관한 연구)

  • Lee J. H.;Ha J. M.;Sung W. M.
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.3 s.15
    • /
    • pp.1-8
    • /
    • 2001
  • This study was carried out for the purpose of determination of maintenance period and investigation of weak point due to freeze when the gas heater of KOGAS valve station Is not operated in winter season. 3-dimensional non-linear numerical simulation was conducted in order to predict the time and location which bath water in heater reaches to ice point. FLUENT V 5.0, commercial code, is used for thermal fluid flow analysis. We thought this was problem of heat conduction solving the energy equation and modeled gas heater by using the real geometry and scale for performing the 3-dimensional simulation. It was analyzed complex heat transfer phenomena considering convection due to air on surface, conduction in insulation material, natural convection of liquid in heater and heat loss through the pipe.

  • PDF

Numerical Analysis of Flow Rate Distribution of Diffusers with Various Shapes (다양한 디퓨저 형상의 유량 분배 특성에 관한 수치해석 연구)

  • Kim, Myoung Soo;Kim, Hoo Bae;Choi, Hyoung Gwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.9
    • /
    • pp.789-795
    • /
    • 2014
  • In this study, the distribution characteristics of diffusers with various shapes that are installed in an open-type thermal storage system are numerically investigated. Four diffusers are designed to distribute a working fluid evenly through the holes on bifurcated pipes. Three-dimensional steady simulations of incompressible laminar flow are conducted using commercial software (ANSYS-FLUENT). The simulation results show that both the bidirectional header-type diffuser and the H-type diffuser distribute the working fluid evenly whereas both the unidirectional and the bidirectional diffusers distribute the working fluid unevenly. The results also show that the H-type diffuser requires a higher head of pump than the bidirectional header-type diffuser. Therefore, the bidirectional header-type diffuser is recommended for use because it enables even distribution of the working fluid and requires a low head of pump.

Assessment of CFD Estimation Capability for the Local Loss Coefficients of Sudden Contraction and Expansion (급격 확대 및 축소관의 압력손실계수에 대한 전산유체역학 해석의 예측성능 평가)

  • Kim, Hyun-Jung;Park, Jong-Pil
    • Applied Chemistry for Engineering
    • /
    • v.21 no.3
    • /
    • pp.258-264
    • /
    • 2010
  • Most of fluid systems, such as P&ID in ships, power plants, and chemical plants, consist of various components. The components such as bends, tees, sudden-expansions, sudden-contractions, and orifices contribute to overall pressure loss of the system. The local pressure losses across such components are determined using a pressure loss coefficient, k-factor, in lumped parameter models. In many engineering problems Idelchik's k-factor models have been used to estimate them. The present work compares the k-factor based on CFD calculation against Idelchik's model in order to confirm whether a commercial CFD package can be used for pressure loss coefficient estimation of complex geometries. The results show that RSM is the best appropriate for evaluating pressure loss coefficient. Commercial CFD package can be used as a tool evaluating k-factor even though the accuracy is influenced by a turbulence model.

Limit Loads for Circular Wall-Thinned Feeder Pipes Subjected to Bending and Internal Pressure. (원형 감육이 발생한 중수로 피더관의 한계하중 평가)

  • Je, Jin-Ho;Lee, Kuk-Hee;Chung, Ha-Joo;Kim, Jong-Sung;Kim, Yun-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.11
    • /
    • pp.1675-1680
    • /
    • 2010
  • Flow Accelerated Corrosion (FAC) occurring during in-service conditions results in localized wall-thinning in the feeder pipes of CANDU. The wall-thinning of the feeder pipes is the main degradation mechanisms affecting the integrity of piping systems. In this paper, we assess the integrity of wall-thinned feeder pipes by limit load analysis. The limit loads for wall-thinning feeder pipes subjected to in-plane bending and internal pressure were determined on the basis of finte element limit analyses. The limit loads are determined from the results of limit analyses of elasticperfectly-plastic materials using the large geometry change. Closed-form approximations of limit load solutions for wall-thinning feeder pipes subjected to in-plane bending and pressure are proposed.

Study on the Pressure Loss of Hoses in a Fire Hose Reel Hydrant (호스릴옥내소화전 호스에 대한 압력손실에 관한 연구)

  • Whang, Young-Kwon;Lee, Seung-Chul
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.63-67
    • /
    • 2019
  • In this study, the pressure loss of a fire hose reel hydrant was examined and the effects of each factor on the pressure loss were analyzed. First, in the pressure loss experiment according to the length of the reel hose, the pressure loss increased with increasing length of the reel hose; it was approximately 38.86% based on a 25 m hose. Second, the pressure loss of the reel hose per unit length was estimated to be $.13{\sim}.15kgf/cm^2$. Third, in the pressure loss experiment according to the change in the flow rate, the result was similar to the relation, flow rate - pressure loss (${\Delta}P{\sim}Q^2$), in the piping flow. These results provide basic data on the evaluation of fire pump pressure and the performance-based fire-protecting design of fire hose reel hydrants used in buildings.