A Study on the Visualization of Ice-formation Phenomena of Bath Water to Decide Maintenance Period of Gas Heater

가스히터 보수주기 결정을 위한 히터내부 열전달 매체액 결빙현상 가시화에 관한 연구

  • Lee J. H. (LNG Technology Research Center, R & D Division, Korea Gas Corporation) ;
  • Ha J. M. (LNG Technology Research Center, R & D Division, Korea Gas Corporation) ;
  • Sung W. M. (Dept. of Geoenvironmental System Engineering, Hanyang University)
  • 이정환 (한국가스공사 연구개발원) ;
  • 하종만 (한국가스공사 연구개발원) ;
  • 성원모 (한양대학교 지구환경시스템공학과)
  • Published : 2001.09.01

Abstract

This study was carried out for the purpose of determination of maintenance period and investigation of weak point due to freeze when the gas heater of KOGAS valve station Is not operated in winter season. 3-dimensional non-linear numerical simulation was conducted in order to predict the time and location which bath water in heater reaches to ice point. FLUENT V 5.0, commercial code, is used for thermal fluid flow analysis. We thought this was problem of heat conduction solving the energy equation and modeled gas heater by using the real geometry and scale for performing the 3-dimensional simulation. It was analyzed complex heat transfer phenomena considering convection due to air on surface, conduction in insulation material, natural convection of liquid in heater and heat loss through the pipe.

본 연구는 한국가스공사에서 운영중인 천연가스 공급관리소의 가스히터를 대상으로 겨울철 히터 가동 중단시, 가스히터 내부의 열전달 매체액 (Bath Water)이 빙점에 도달하는 시간을 계산하여 보수주기에 대한 결정 및 동파 취약 부위에 대한 영향을 판단하기 위해 가스히터의 체적을 고려한 비선형 3차원 전산모사를 수행하였다. 이용된 시뮬레이터는 미국 FLUENT사의 FLUENT V 5.0으로서 열유체 유동해석 범용 Code이다. 본 문제는 열전도에 관한 문제로 에너지 방정식을 푸는 방식으로 진행되지만 가스히터의 체적을 고려한 3차원 계산을 수행하기 위해 현장의 가스히터 형상 및 축적을 거의 유사하게 모델링하였고 표면에서 공기에 의한 대류 (Convection)문제와 단열재 사이의 전달 (Conduction)문제, 히터내부 액체의 자연대류 (Natural Convection) 그리고 배관을 통한 열손실의 문제를 고려한 복합적인 열전달 현상을 분석하였다.

Keywords