Partial discharge properties of insulating materials for UPS (UPS용 절연재료의 부분방전 특성)

  • 이덕진
    • Journal of the Korea Computer Industry Society
    • /
    • v.4 no.12
    • /
    • pp.1013-1020
    • /
    • 2003
  • In this paper, the discharge properties due to time variation were investigated in order to estimate a electrical performance of the insulator for small transformer. AC 10[kVl applied to specimen was converted to $\pm$5[V] and stored to personal computer through A/D converter. A period of applied wave form and discharge values were divided into 64 parts and discharge values generated during 10 seconds were accumulated by phases. As a result, it was confirmed that count of discharge, total discharge and the variation degree of average discharge were decreased as time elapsed.

  • PDF

Analysis of The Partial Discharge Pattern in XLPE using Statistical Distribution (분포통계를 이용한 XLPE의 부분방전 패턴해석)

  • Kim, Tag-Yong;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.35-40
    • /
    • 2006
  • 최근 전기에너지의 사용비율은 해가 거듭될수록 증가되고 있으며, 경량화 소형화로 인한 전력기기의 스트레스가 증가되었다. 또한 고압송전으로 인해 전기적 사고는 대형사고를 유발하므로 전력기기의 수명예측은 매우 중요한 과제이다. 이에 본 논문에서는 XLPE 절연체의 보이드 유무에 따른 부분방전 패턴을 K-means 분포통계함수를 이용하여 부분방전 패턴의 그룹화를 시도하였다. 또한 전하량과 방전빈도수의 분포를 비교하기 위해 위상-전하랑 및 위상-전하량-빈도수에 의한 그룹의 centroid 이동 변화에 대하여 조사하였다. 그 결과 보이드가 존재하는 경우 전하량의 높은 점에서 중심점을 형성하였고, 방전발생위상의 차이는 크지 않았다. 또한 위상-전하량의 클러스터보다 위상-전하량-빈도수의 클러스터에서 객체간 편차가 더 커짐을 발견하였다.

  • PDF

Evaluation on Insulation Performance of Traction Motors for a Hybrid Vehicle by Partial Discharge Measurement (부분방전 측정에 의한 하이브리드차량 견인전동기의 절연성능평가)

  • Park, Dae-Won;Park, Chan-Yong;Choi, Jae-Sung;Kil, Gyung-Suk;Lee, Kang-Won
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.2
    • /
    • pp.249-253
    • /
    • 2009
  • This paper dealt with the insulation evaluation by a measurement of partial discharge(PD) on traction motors used in a hybrid vehicle. The PD method has been accepted as an effective and a non-destructive. technique to evaluate insulation performance of low-voltage electric and electronic devices. In this paper, the PD measurement system which was manufactured with a coupling network, a low noise amplifier, and an associated electronics is described. The PD measurement system has the frequency bandwidth of $1[MHz]{\sim}30[MHz]$ at -3 [dB] and the stable sensitivity of 19 [mV/pC] for the traction motor. From the experimental results, discharge inception voltage (DIV) and apparent charge (q) were $1,100[V_{rms}]$ and 105 [pC] for the used motor, and $1,400[V_{rms}]$ and 84 [pC] for the new one. By comparing the DIV and q, we could evaluate the insulation condition for the traction motors.

Porous Carbon Aerogel-Silica Gel Composite Electrodes for Capacitive Deionization Process (전기용량적 탈이온 공정을 위한 다공성 탄소에어로젤-실리카젤 복합전극)

  • Yang Chun-Mo;Choi Woon-Hyuk;Cho Byung Won;Han Hak-Soo;Yun Kyung Suk;Cho Won Il
    • Journal of the Korean Electrochemical Society
    • /
    • v.7 no.1
    • /
    • pp.38-43
    • /
    • 2004
  • Porous carbon aerogel-silica gel composite materials were used as the electrodes of capacitive deionization(CDI) process, which were prepared by a paste rolling method. The electrochemical parameters such at current values, coulombs af a function of cycle, and CDI efficiencies were investigated for 10th and 100th cycles in 1,000ppm NaCl solution. Carbon aerogel-silica gel composite electrodes showed good wet-ability and higher mechanical strengths even under the NaCl solutions as well. In our experimented runs, all of the composite electrodes also are showed good cycle-ability without destroy of active material during cycles and decreased manufacturing times by $50\%$. Conclusively, the adding of silica gel powder to carbon aerogel leads to the effective performance of CDI process due to effective utilization of active materials by increasing the wet-ability and mechanical hardness.

Deterioration Diagnosis of Epoxy Mold-type Transformer Using Ultrasonic Waves (초음파를 이용한 에폭시 몰드변압기의 열화 진단)

  • 이상우;김인식;이동인;이광식;이동희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.3
    • /
    • pp.73-81
    • /
    • 1999
  • Measurements of ultrasonic signals caused by partial discharges were perlonnrl by using an ultrasonic measurement technique to diagnose the electrical treeing deterioration in an epoxy mold-type power transformer. We also examined the characteristics of tree growth, partial discharge magnitude and ultrasonic pulse number with the increase of the deterioration time. From these results, it was found that the shape of the tree was a branch-type, and the rates of the tree growth were examined when ac voltages of 16[kV] and 20[kV] were applied Ultrasonic pulse number and discharge magnitude were rapidly increased as the length of the tree grows after the middle stage of the deterioration time, and it appeared that ultrasonic pulse number was proportional to discharge magnitude. Attenuation, time-delaying and directivity characteristics of ultrasonic signals propagated into epoxy resin by using ultrasonic oscillation and receiving systems are also re[prted as a basic data of ultrasonic mesasurements in mold-type power transformer.former.

  • PDF

정지궤도 위성용 ESD 시험 장비 개발

  • Jang, Gyeong-Deok;Kim, Tae-Yun;Jang, Jae-Ung;Mun, Gwi-Won
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.195.2-195.2
    • /
    • 2012
  • 궤도상에서 지구의 대기는 태양의 복사에너지에 의하여 양이온과 음이온으로 이온화된 자유 전자로 존재하게 되는데 이러한 상태를 플라즈마 환경이라고 부른다. 인공위성이 궤도에서 운용될 때, 플라즈마 환경에서의 강한 에너지를 가진 전하들은 위성을 투과하여 위성 내부에 축적될 수 있다. 이러한 전하들은 고립되어 있는 전도체의 끝에 모이게 되고, 전하량이 breakdown 레벨에 이르게 되면 아크 방전이 일어나게 된다. 방전에 의한 전류가 민감한 회로에 들어가게 되면 오동작이나 기능손상을 일으킬 수 있다. 보통 저궤도 위성이 놓이게 되는 낮은 고도와 경사각에서 플라즈마는 밀도가 높고 낮은 에너지를 가지는 반면, 정지궤도 위성이 놓이게 되는 높은 고도의 플라즈마는 낮은 밀도와 지구자기 폭풍 등에 기인하여 높은 에너지를 갖는다. 따라서 정지궤도 인공위성의 경우 ESD의 영향을 좀 더 면밀하게 검토하고 검증할 필요가 있다. 본 논문에서는 정지궤도 위성용 ESD 시험장비의 개발결과에 대하여 논의한다. 시험장비는 ESD 건과 Spark gap, 몇몇의 저항 및 캐패시터로 구성된다. 정지궤도 상에서의 ESD 방전 전류를 모사하는 파형을 구현하기 위한 방법과 결과를 소개하였다.

  • PDF

XLPE Diagnostics according to Analysis of Discharge Number (방전발생 빈도해석을 통한 XLPE 절연진단)

  • Kim, Tag-Yong;Shin, Jong-Yeol;Lee, Soo-Woon;Hong, Jin-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.89-91
    • /
    • 2004
  • 본 논문은 XLPE 절연재료의 보이드에 따른 방전빈도를 와이블 함수로 조사하였으며, 또한 방전빈도와 결함에 대한 상관관계를 와이블 해석을 이용한 진단시스템을 제안하고 있다. 인가전압은 교류 60[Hz]를 방전개시전압을 기점으로 1[1kV]씩 승압하였으며, 전하량이 512[pC]이상이 발생하면 검출한도를 초과하므로 실험을 멈추었다. 그 결과 보이드 시료에서 큰 형태파라메터값을 나타냄을 확인하였다.

  • PDF

A Study on Calibration Signal for Test of The Partial Discharge Measurement (부분방전 측정 시험을 위한 기준신호에 관한 연구)

  • Lee, Yong-Sung;Lee, Kyoung-Yong;Choi, Yong-Sung;Lee, Chang-Su;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.110-111
    • /
    • 2004
  • 본 논문은 부분방전 검출 시험 전에 수행하는 Calibration 신호 주입 및 검출 방법에 대한 연구이다. 사용된 시료는 지중케이블의 절연층으로 사용되는 XLPE 시트와 XLPE케이블이다. 실험방법은 50kV 내전압기(750-2CTS, Hipotronics)로부터 공급된 Calibration 신호를 Lemke (LDP-5, LDIC), 오실로스코프 (TDS-3012, Tektronix)와 주파수 분석기 (8563E, HP)를 사용하여 측정하였다. 시험에 사용된 센서로는 자체 제작한 박전극센서, UHF 센서 그리고 Lemke UHF 센서를 사용하였다. 위 방법을 통해 신호의 형태와 인가 전하량에 따른 Calibration 파형과 전하량 변화를 비교하였다. 실험결과 Calibration 신호 주입시 시험 환경 및 센서에 따라 Calibration 신호와 주입방법의 차이가 발생하였다.

  • PDF

The Detection of Calibration Signal for Test of the Partial Discharge Measurement (부분방전 측정 시험을 위한 기준 신호 검출)

  • Lee, Yong-Sung;Lee, Kyoung-Yong;Choi, Yong-Sung;Lee, Chang-Su;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.316-318
    • /
    • 2004
  • 본 논문은 부분방전검출 시험 전에 수행하는 Calibration 신호 주입 및 검출 방법에 대한 연구이다. 사용된 시료는 활선상의 배전용 XLPE 케이블이다. 실험방법은 50kV 내전압기 (750-2CTS, Hipotronics)로부터 공급된 Calibration 신호를 Lemke (LDP-5, LDIC), 오실로스코프 (TDS-3012, Tektronix)와 주파수 분석기 (8563E, HP)를 사용하여 측정하였다. 마지막으로 시험에 사용된 센서는 안테나 특성의 UHF 센서와 고주파 특성의 HFCT 센서이다. 실험결과, Calibration 신호 주입 시 시험 환경 및 센서에 따라 Calibration 신호와 주입방법의 차이가 발생하였다. 따라서 신호의 형태와 인가 전하량에 따른 Calibration 파형과 전하량 변화를 알 수 있었다.

  • PDF