• Title/Summary/Keyword: 방전관

Search Result 198, Processing Time 0.028 seconds

Improvement of Electrical Discharge Drilling (방전드릴링의 가공특성 향상)

  • Song, Ki-Young;Chung, Do-Kwan;Park, Min-Soo;Chu, Chong-Nam
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.10
    • /
    • pp.45-51
    • /
    • 2010
  • Electrical discharge drilling (ED-drilling) is a widespread machining method used to bore small holes with a high aspect ratio. This paper presents additional methods by which ED-drilling can improve machining speed, tool wear, and machined surface quality. Firstly, for high machining speed, and low tool wear, a new-type electrode that was ground on one side or both sides of the cylindrical electrodes was suggested to expel debris. The debris which is generated during the machining process can cause sludge deposition and secondary discharge problems: major reasons to decrease machining speed. This new-type electrode also reduced tool wear that was due to the decrease of unstable discharge in a machining gap by helping to expel waste water and debris from the gap. Secondly, to improve the machined surface roughness, an electrolyzation process was included after drilling. This process made the machined surface smooth by means of an electrochemical reaction between an electrode and a workpiece. In this study, the machining speed, electrode wear, and surface roughness were improved by the newtype electrode and the electrolytic process.

Micro Hole Machining by EDM Using Insulated Tool Combined with Ultrasonic Vibration of Dielectric Fluid (가공액의 초음파 진동 및 절연 공구를 이용한 미세방전가공)

  • Park, Min-Soo;Chung, Do-Kwan;Lee, Kang-Hee;Chu, Chong-Nam
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.2
    • /
    • pp.180-186
    • /
    • 2011
  • This paper describes a micro electrical discharge machining (MEDM) technique that uses an insulated tool in combination with ultrasonic vibration to drill micro holes. As the machining depth becomes deeper, the dispersion of debris and circulation of the dielectric fluid are difficult to occur. Consequently, machining becomes unstable in the machining region and unnecessary electrochemical dissolution and secondary discharge sparking occur at the tool side face. To reduce the amount of unnecessary side machining, an insulated tool was used. Ultrasonic vibration was applied to the MEDM work fluid to better remove debris. Through these methods, a $1000\;{\mu}m$ thick stainless steel plate was machined by using a $73\;{\mu}m$ diameter electrode. The diameters of the hole entrance and exit were $96\;{\mu}m$ and $88\;{\mu}m$, respectively. It took only 351s to completely drill one hole.

Micromachining Using Hybrid of Laser Beam and Electrical Discharge Machining (레이저 빔 가공과 방전 가공을 이용한 복합 미세 가공)

  • Kim, San-Ha;Chung, Do-Kwan;Kim, Bo-Hyun;Oh, Kwang-Hwan;Jeong, Sung-Ho;Chu, Chong-Nam
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.10
    • /
    • pp.108-115
    • /
    • 2009
  • Although nanosecond pulsed laser drilling and milling are rapid and non-wear processes in micromachining, the quality cannot meet the precision standard due to the recast layer and heat affected zone. On the other hand, electrical discharge machining (EDM) is a well-known high precision machining process in micro scale; however, the low material removal rate (MRR) and tool wear remain as drawbacks. In this paper, hybrid process of laser beam machining (LBM) using nanosecond pulsed laser and micro EDM was studied for micro drilling and milling. While the quality of the micro structure fabricated by this hybrid process remains as high as direct EDM, the machining time and tool wear can be reduced. In addition, variable depth of layer was introduced as an effective method improving efficiency of hybrid milling.

Development of an Electronic Ballast for 70W Ceramic Discharge Metal Halide Lamps with Step Down Converter (강압형 컨버터를 이용한 70W CDM 램프용 전자식 안정기의 개발)

  • 김일권;길경석;김진모
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.435-439
    • /
    • 2002
  • This paper describes a design and fabrication of an electronic ballast for 70[W] ceramic discharge metal halide lamps. The proposed ballast is composed of a rectifier, an active power factor correction circuit (PFC), a half-bridge inverter, a LC resonant circuit and a microprocessor. The developed ballast also includes a specially designed time circuit which provides reignition of lamps. Running frequency of the ballast is set at 40[kHz] to avoid acoustic-resonance and flickering. From the experimental results, input power factor and efficiency of the ballast are estimated 99.8[%] and 93.1[%)] respectively.

  • PDF

Removal characteristic of Escherichia coli for Discharge tube with globular $SiO_2$ (구형 $SiO_2$를 갖는 방전관의 수중 세균제거특성)

  • Lee, Dong-Hoon;Park, Hong-Jae;Park, Jae-Youn
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.546-549
    • /
    • 2003
  • This paper was shown removal characteristic of escherichia coli for discharge tube with globular $SiO_2$. At the result of the removal characteristic experiments of escherichia coli using the discharge tube with globular $SiO_2$, because the electric field is also increased when input voltage is increased, the removal characteristic of escherichia coli was appeared relation connection to input voltage. If a passing number of test water in discharge tube is increased, the removal ratio of escherichia coli is increased because passing number of electric field section is increased. When diameter of globular $SiO_2$ is increased, the removal time of escherichia coli is to be decreased because dielectric polalization of globular dielectric($SiO_2$), Also, the removal ratio of escherichia coli of the discharge tube with globular dielectric($SiO_2$) is appeared higher than the removal ratio of the discharge tube without globular dielectric($SiO_2$).

  • PDF

Problems and Countermeasures in Installation of Down Conductor Systems (인하도선시스템 시설에서의 문제점과 대책)

  • 이복희;이동문;강성만;엄주홍;정동철;이승칠;안창환
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.4
    • /
    • pp.38-45
    • /
    • 2002
  • This paper describes the technical issues of the domestic standard and guideline for lightning protection systems in order to propose the countermeasures in damage of computer and electronic equipments due to lightning surges. The relationship between the current flow in the down conductor and the current flow in the steel conduit surrounding the down conductor was investigated as a function of the installation method of down conductors. Also the experiments were conducted to evaluate the influences of the skin effect on the down conductor systems. As a result, when the down conductor were bonded to the steel conduit, the down conductor and the steel conduit act as one conductor, so much mure lightning current flows in the steel conduit than in the copper down conductor because of the skin effect and choking effect. Therefore to reduce the adverse effects such as the electrostatic induction and side flashes caused by the potential rise of down conductors due to lightning currents, it is extremely effective to bond the down conductor to the steel conduit and steel frame of structures.

The Output Characteristics of Flashlamp Pumped Ti:sapphire Laser Enhanced by Energy Transfer Dye (에너지 전환 방식에 의한 섬광관 펌핑 Ti$^{3+}$ : Sapphire 레이저의 발진특성)

  • 김희경
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.442-446
    • /
    • 1993
  • A flashlamp pumped Ti: sapphire laser was designed and fabricated in the laboratory. In order to find out the optimum pumping condition, three kinds of discharge circuits of which the pulse width are 10${\mu}s$, 45${\mu}s$, 65${\mu}s$ were designed. The fluorescent energy converter LD-490 of which the fluorescence spectra is coincident to the absorption band of Ti: sapphire was used to improve the laser efficiency. The laser output characteristics for three different concentrations of LD-490 and for three different pumping pulse widths were measured. As a result, the shorter the flashlamp pulse width, the higher the overall efficiency was achieved. When pumping light pulsewidth was 10${\mu}s$, the best efficiency was obtained at the concentration 1.0${\times}10^{-3}$mol/l of LD-490 dye. At lower concentrations the efficiencies were decreased.

  • PDF

Monostatic RCS Measurement for Dielectric Barrier Discharge Plasma (유전체 장벽 방전 플라즈마의 Monostatic 레이다 단면적 측정)

  • Lee, Hyunjae;Jung, Inkyun;Ha, Jungje;Shin, Woongjae;Yang, Jin Mo;Lee, Yongshik;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.3
    • /
    • pp.246-252
    • /
    • 2016
  • In this paper, reduction of monostatic RCS by DBD plasma is measured. For the calibration of monostatic RCS, S-parameters of two metallic plate in different sizes are used and the result is within 0.4 dB error. Metallic plate is put behind DBD plasma generator for measuring reduction of monostatic RCS by DBD plasma. To prevent arc discharge between metallic plate and DBD plasma generator, measurement is progressed spacing the interval between metallic plate and DBD plasma generator. As a result, maximum reduction of monostatic RCS is about 3 dB at 7.4 GHz.

Characteristics of Sparkover Discharge in Flowing Air with the variation of Reynolds Number (Reynolds Number를 변수로한 유동공기의 방전특성)

  • 김영헌;이광식;이동인
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.5 no.2
    • /
    • pp.37-48
    • /
    • 1991
  • This paper shows the characteristics of sparkover discharge in flowing air ranging from O(Reynolds number, Re) to $10.52{\times}10^4$(Re). Also, we investigated changes of discharge pattern for constant input power by adjustment of the Reynolds number. Flowing air duct of this investigation is a circular tube. The flow at the experimented positions' section is described as fully development laminar flow. The important results obtained from this study are as follows. The sparkover discharge path of flowing air can be analyzed by the theories of flow field for air. The sparkover voltage shows nearly the maximum value when the Reynolds number of flowing air ranges $3{\times}10^4$ to $4{\times}10^4$The maximum sparkover voltages of flowing air are about 6.3[kV] higher than those of static air. The discharge pattern can be controlled by adjustment of the Reynolds number.

  • PDF

Decolorization of Azo Dyeing Wastewater Using Underwater Dielectric Barrier Discharge Plasma (수중 유전체장벽방전 플라즈마를 이용한 아조 염색폐수 색도제거)

  • Jo, Jin Oh;Lee, Sang Baek;Mok, Young Sun
    • Applied Chemistry for Engineering
    • /
    • v.24 no.5
    • /
    • pp.544-550
    • /
    • 2013
  • This work investigated the environmental application of an underwater dielectric barrier discharge plasma reactor consisting of a porous hydrophobic ceramic tube to the decolorization of an azo dyeing wastewater. The reactive species generated by the plasma are mostly short-lived, which also need to be transferred to the wastewater right after the formation. Moreover, the gas-liquid interfacial area should be as large as possible to increase the decolorization rate. The arrangement of the present wastewater treatment system capable of immediately dispersing the plasmatic gas as tiny bubbles makes it possible to effectively decolorize the dyeing wastewater alongside consuming less amount of electrical energy. The effect of discharge power, gas flow rate, dissolved anion and initial dye concentration on the decolorization was examined with dry air for the creation of plasma and amaranth as an azo dye. At a gas flow rate of $1.5Lmin^{-1}$, the good contact between the plasmatic gas and the wastewater was achieved, resulting in rapid decolorization. For an initial dye concentration of $40.2{\mu}molL^{-1}$ (volume : 0.8 L; discharge power : 3.37 W), it took about 25 min to attain a decolorization efficiency of above 99%. Besides, the decolorization rate increased with decreasing the initial dye concentration or increasing the discharge power. The presence of chlorine anion appeared to slightly enhance the decolorization rate, whereas the effect of dissolved nitrate anion was negligible.