• Title/Summary/Keyword: 방열핀

Search Result 59, Processing Time 0.034 seconds

Study on Thermal Efficiency according to Configuration Change and Contact Resistance of Solar Collector with Single Evacuated Tube-type (단일진공관 태양열집열기의 형상변화 및 접촉저항에 따른 집열효율 연구)

  • Choi, Bo-Won;Yang, Young-Joon
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.189-195
    • /
    • 2014
  • The use of solar energy among renewable energy tends to increase because of its infinity and cleanness of resources. Even though the consumption rate of solar energy in our country is still low, however, in recent years, the research for solar energy have been widely conducted due to policy support of government. This study was performed to investigate the efficiency of heat collection using solar collector with single evacuated tube-type. As the results, the temperature of radiation fin for solar collector with single evacuated tube-type was lower in spite of high temperature of heat pipe compared that of double evacuated tube-type. In order to increase the efficiency of heat collection, it was confirmed that the loss of heat collection due to contact resistance as well as performance improvement for solar collector should be decreased.

Perfonnance Evaluation of Swaged- and Extruded-type Heat Sinks Used in Inverter for Solar Power Generation (태양광 발전용 인버터 방열에 사용되는 압입형 및 압출형 히트싱크의 방열 성능 평가)

  • Kim, Jung Hyun;Lee, Gyo Woo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.10
    • /
    • pp.933-940
    • /
    • 2013
  • In this study, we evaluated the heat release performance of two extruded-type and two swaged-type heat sinks used in an inverter for solar power generation. The number of fins and heat transfer areas of the two swaged-type heat sinks, namely S-62 and S-98, are 62 and 98 and $2.8m^2$ and $5.3m^2$, respectively. Those for the two extruded-type heat sinks, namely, E-38 and E-47, are 38 and 47 and $1.8m^2$ and $1.9m^2$, respectively. The heat release fractions of S-62 and S-98 were measured as 82.7 % and 86.3 %, respectively. Those of E-38 and E47 were measured to be 79.6 % and 81.6 %, respectively. In this experiment, despite the mass flow rates of air entering the heat sinks being almost the same, the heat release fractions increased with heat transfer area. Furthermore, despite S-62's heat transfer area being 47.4 % higher than that of E-47, its heat release fraction was higher by only 1.3 %. We believe that this indicates the better heat transfer property of the extruded-type heat sink. S-98's heat release is only 4.4 % higher than that of S-62, but its heat transfer area is 89.3 % higher; this suggests that its heat transfer area need to be optimized.

Analysis and Dynamic Modeling of a High-speed Tube Expander (고속 Tube Expander의 동적 모델링 및 해석)

  • 김재량;정원지;김수태;최욱환
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.401-411
    • /
    • 2003
  • Tube expanding process is for combining a heat-sink plate with hair-pins (Cu-tube) through plastic deformation. The two parts, i. e. , heat-sink plate and hair-pins are they components of a heat-exchanger for an air conditioner. This paper presents the analysis and dynamic modeling of a high-speed tube expander which integrates transfer of parts, fixing of parts, and tube expanding into one process. The 3-dimensional modeling of all the parts for the tube-expander was constructed using CATIA$\circledR$. then the CATIA$\circledR$ models are transferred into visuaINastran$\circledR$ to execute the 3-dimensional animation for checking prescribed cycle-time. The technique presented in this paper has been shown to be effective as a priori tool for verifying the design of a high-speed tube expander.

  • PDF

Thermal Analysis of Vegetable Insulation Oil for Hermetically Sealed Wind Turbine Transformer (풍력발전기용 밀폐형 변압기의 식물성 절연유에 대한 열적특성 연구)

  • Lee, Sung-Won;Lee, Joon-Yeob;Kim, Jun-Su;Woo, Jae-Hi;Kim, Dong-Hae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.1
    • /
    • pp.97-102
    • /
    • 2012
  • A hermetically sealed oil transformer is designed by applying expanding function of the tank due to the volume changes of the insulation oil according to the temperature rises. When the insulation oil expands, an increase in the volume of the corrugated fin prevents a pressure rise of the transformer. For a wind turbine transformer, a vegetable-oil-immersed transformer has the advantages of excellent biodegradation and fire-resistant properties like an exceptionally high fire point. When vegetable oil is substituted for mineral oil, however, the maximum winding temperature rises because of the decrease in the internal circulation flow rate resulting from the variations of the oil's physical characteristics, such as density and viscosity. The purpose of this study is to develop a hermetically sealed vegetable oil transformer that can be applied in a wind turbine and to analyze the thermal stability of the active part of the transformer to deal with pressure variations due to the temperature changes. In addition, thermal tests for the vegetable oil transformer have been performed, and the measured values are compared with the analysis results.

Development of Vapor Oil for Radiator Ein Press (방열핀 프레스용 베이퍼 오일 개발)

  • 전성철;조정희
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.129-133
    • /
    • 2000
  • Vapor oil fer radiator fm press in heat exchangers of air conditioners is carefully considered as the cooling performance can be affected by the residual vapor oil on the surface of radiator fin after fin press working. In this work, vapor oil for radiator fin press was developed in consideration of several properties such as physical characteristics, the rate of volatility, hazardous properties and material compatibility. In addition, it was confirmed that radiator fin press workability adopting the vapor oil and the cooling performance of air conditioner using the radiator fin were good.

  • PDF

A Basic Study on Air Flow Characteristics in Louvered Fins (루버 핀을 지나는 공기의 유동특성에 대한 기초적 연구)

  • 강창수;최태민
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.5
    • /
    • pp.1276-1293
    • /
    • 1993
  • A numerical and experimental flow visualization study of the louvered fin array, commonly used in a compact heat exchanger was performed. The flow structure which was obtained by using a finite difference method, was compared with an experimental result. The experimental flow visualization was performed by using a dye injection technique with 13:1 scale model. The effects of Reynolds number and fin geometries on flow structure and heat transfer were examined.

Heat Transfer Enhancement by Fins in a Latent Heat Storage System Using Phase Change Material (상변화물질을 이용한 축열시스템에서 핀에 의한 열전달 촉진 연구)

  • 한승구;한귀영
    • Journal of Energy Engineering
    • /
    • v.5 no.2
    • /
    • pp.115-122
    • /
    • 1996
  • Heat transfer characteristics of low temperature latent heat storage systems have been examined for the circular finned and unfinned tubes using Na$_2$B$_4$O$\_$7/10H$_2$O as a phase change material. In order to reduce the supercooling of PCM, 3 wt% of Na$_2$B$_4$O$\_$7/10H$_2$O was added as the nucleating agent and 2.2 wt% of acrylic acid sodium sulfate was used as the thickener. The heat storage vessel has dimension of 530 mm height, 74 mm 1.D. and inner heat transfer tube is 480 mm height and 13.5 mm O.D. Water was employed as the heat transfer fluid. During the heat recovery experiment, the heat recovery rate was affected by the flow rates and inlet temperature of heat transfer fluid. The enhancement of heat transfer by fins over the unfinned tube system was found to be negligible in the thin finned tube systems, whereas the heat transfer coefficient in the thick finned tube system is approximately 60% higher than that in the unfinned lobe system. The experimentally determined heat transfer coefficient for the unfinned tube and thick finned tube systems are 150-260 W/㎡$^{\circ}C$ and 230-530 W/㎡$^{\circ}C$, respectively. The fin efficiency based on the heat transfer coefficient and area increased by fins was found to be 0.05 and 0.26 for the thin and the thick finned tube systems.

  • PDF

The study of thermal properties of graphene/Cu foam hybrid structures (그래핀/구리폼과 그래파이트 하이브리드 구조체의 열전도 특성 연구)

  • Kim, Hee Jin;Kim, Hyeungkeun;Kim, Yena;Lee, Woo Sung;Yoon, Dae Ho;Yang, Woo Seok
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.23 no.5
    • /
    • pp.235-240
    • /
    • 2013
  • Pure-carbon materials such as graphite, graphene, carbon nanotubes, and diamond have very high thermal conductivities. The reported thermal conductivity of graphene is in the range 3000~5000W/m-K at room temperature. Here, we developed graphene/cu foam hybrid type heat spreader to obtain higher thermal conductivity than Cu foam. Hybrid materials were characterized using optical microscopy (OM), scanning electron microscopy (SEM) and thermal conductivity measurement system; LFA (Laser Flash Analysis @ LFA 447, NETZSCH). We suggest that excellent thermal properties of graphene/cu foam hybrid structures are beneficial for all proposed electrical applications and can lead to a thermal management application.