• Title/Summary/Keyword: 방사왜곡

Search Result 109, Processing Time 0.028 seconds

PIMD Performance Test of Active Baseband Antenna (능동형 기지국안테나의 PIMD 특성분석)

  • Kim, Jae-Hak;Jung, Young-Bae
    • Journal of IKEEE
    • /
    • v.17 no.2
    • /
    • pp.163-167
    • /
    • 2013
  • As the mobile services have been increased, the interference of the neighboring base stations is increased and the PIMD(Passive Inter-Modulation Distortion) has been a main issue for the design of base station antenna systems. In this paper, it is proposed the PIMD test method for the active basestation antenna whose radiators are directly connected with main active parts including amplifiers, and we presents its test results using a developed active basestation antenna. From the results, the active basestation antenna has the better PIMD performance than conventional passive structure by 8.4dB. The proposed PIMD test method can be used to get the accurate PIMD test result because the test environment is very similar with real basestation.

A Study on Radiation Dose and Image Quality using Dual Energy Computed Tomography ECG Gating High Pitch Chest Pain Protocol Mode (이중 에너지 전산화 단층촬영 ECG Gating High Pitch Chest Pain Protocol 모드를 이용한 방사선량과 영상 품질에 관한 연구)

  • Kim, Gyeong-Rip;Sung, Soon-Ki;Kim, Chang-Hyeun;Kwak, Jong-Hyeok
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.7-13
    • /
    • 2022
  • This study compared the aortic root image by using the ECG gating and non-ECG gating methods. We observed the presence or absence of progression of the aortic root image in the images examined by the high pitch (flash) chest pain protocol method and in the patients tested without ECG gating by the conventional method. The AAPM phantom was scanned by using high pitch (flash) chest pain protocol and general chest pain protocol. CTDI values were compared. By ECG gating, the blurring of ascending aorta was significantly reduced compared to the existing non-ECG gating test method, and the image quality of the aortic root was improved. Within the parametar range that did not show differences in noise, uniformity, and high contrast resolution, CTDI values were lower when tested with the high-pitch chest pain protocol. It was found that there is an advantage in dose reduction, and if it is applied and applied to diagnostic fields such as dissection using the dose reduction mode in the cardiac field, it is a very important test for patients who need rapid diagnosis and prompt treatment as well as a dramatic reduction in exposure dose. It is presumed to be a method.

Design of CFL Linearisation Chip for the Mobile Radio Using Ultra-Narrowband Digital Modulation (디지털 초협대역 단말기용 CFL 선형화 칩 설계)

  • Chong Young-Jun;Kang Min-Soo;Yoo Sung-Jin;Chung Tae-Jin;Oh Seung-Hyeub
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.7 s.98
    • /
    • pp.671-680
    • /
    • 2005
  • The CFL linearisation chip which is one of key devices in ultra-narrowband mobile radio transmitter using CQPSK digital modulation method is designed and implemented with $0.35{\mu}m$ CMOS technology. The reduced size and low cost of transmitter are available by the use of direct-conversion and CFL ASIC chip, which improve the power effi챠ency and linearity of transmitting path. In addition, low power operation is possible through CMOS technology The performance test results of transmitter show -25 dBc improvement of IMD level at the 3 kHz frequency offset and then satisfy FCC 47 CFR 90.210 E emission mask in the operation of CFL ASIC chip. At that time, the transmitting power is about PEP(Peak-to-Envelope Power) 5 W. The main parameters to improve the transmitting characteristic and to compensate the distortion in feed back loop such as DC-offset, loop gain and phase value are interfaced with notebook PC to be controlled with S/W.

Study on accuracy of panorama and CBCT through length measurement of wisdom teeth (사랑니 길이 측정을 통한 파노라마와 CBCT의 정확도 연구)

  • Jeong, Cheonsoo;Kim, Chongyeal
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.131-136
    • /
    • 2013
  • Panorama of dental radiation generators can observe the wide anatomical structures of oral and maxillofacial areas but there can be distortion of lengths, angles, or shapes. CBCT can diagnose 3D images and get the ones whose errors by superposition and interference are remarkably smaller between anatomical structures. But the quality of the images by movement of subjects can be lowered as it takes long to diagnose them. And if there are impermeable radiation objects like metal in mouths, impermeable radiation lines can radially appear with the objects as center. This study tries to analyze accuracy of panorama and CBCT and get useful anatomical information in dental treatment by comparing the length of wisdom teeth which were measured by Panorama and CBCT with the teeth which were actually extracted and analyzing distortion of the teeth. The test result could be found that Panorama is expanded by average 7.3% as the errors of Panorama and Digital Vernier Caliper range from 110.7% to 103.9%. The length of wisdom teeth which were measured in CBCT and Digital Vernier Caliper could be found that the error range is 1.3%. And the length of wisdom teeth which were measured in Panorama and Digital Vernier Caliper has found that the error range shows 7.3%. So it could be found that the images of CBCT is about 6% more exact than those of Panorama. It could be found that CBCT shows the more exact images than those of Panorama. But because the examination expenses of CBCT are higher than those of Panorama and exposure dose of CBCT is much more than that of Panorama, it is thought to find proper ways in examination.

Design of a Dual-Band GPS Array Antenna (이중 대역 GPS 배열 안테나 설계)

  • Kim, Heeyoung;Byun, Gangil;Son, Seok Bo;Choo, Hosung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.7
    • /
    • pp.678-685
    • /
    • 2013
  • In this paper, we propose a design of dual-band patch antennas for Global Positioning System(GPS) applications, and the designed antenna is used as an individual element of GPS arrays. A low distortion and a high isolation of the array are achieved by adjusting rotating angles of each array element. The antenna consists of two radiating patches that operate in the GPS $L_1$ and $L_2$ bands, and the two ports feeding network with a hybrid chip coupler is adopted to achieve a broad circular polarization(CP) bandwidth. The rotating angles of each antenna element are varied with four directions(${\phi}=0^{\circ}$, ${\phi}=90^{\circ}$, ${\phi}=180^{\circ}$, ${\phi}=270^{\circ}$) in order to minimize the pattern distortion and maximize the isolation among array elements. The measurement shows bore-sight gains of 0.3 dBic($L_1$) and -1.0 dBic($L_2$) for the center element. Bore-sight gains of 1.6 dBic($L_1$) and 1.0 dBic($L_2$) are observed for the edge element. This results demonstrate that the proposed antenna is suitable for GPS array applications.

Three-dimensional CT image study on the correction of gonial angle width enlarged on frontal cephalogram (정모두부방사선사진에서 하악골 우각부 영상확대 및 이의 보정에 관한 3차원 CT영상 연구)

  • Hwang, Hyeon-Shik;Eun, Chun-Sun;Hwang, Chung Hyon;Lim, Hoi-Jeong
    • The korean journal of orthodontics
    • /
    • v.35 no.4 s.111
    • /
    • pp.251-261
    • /
    • 2005
  • Enlargement is an inherent property of X-rays which occurs when straight hues diverse from small a focal spot. The purpose of the present study was to evaluate the validity of the correction of gonial angle width enlarged on frontal cephalogram, using frontal and lateral cephalograms taken orthogonally from each other. In 40 adult individuals, frontal and lateral cephalograms were taken at a $90^{\circ}$ angle using the Head Posture Aligner. The angle width was measured on the frontal cephalogram and subsequently. the corrected angle width was calculated using the magnification rate of two cephalograms. Measured and corrected angle widths were compared with the measurement from the 3D CT image. The measurement or the frontal cephalogram showed a 9.10mm of enlargement on average ranging from 7.92 to 11.31mm. Corrected angle width measurement showed a 0.14mm difference with the 3D CT image measurement, which was not statistically significant. The results of the study indicate that actual au91e width can be approached through calculation using frontal and lateral cephalograms taken orthogonally with the help of the Head Posture Aligner The study also showed that the magnitude of correction error did not show a significant correlation with the amount of menton deviation, and it suggests that the present correction method is valid even in individuals with severe facial asymmetry.

A Study of Image Characteristics due to Focus-Grid and Head Phantom Decentering from the Armorphos Silicon Thin Film Transistor Detector the Fixed Focus-Grid is Applied (고정식 초점형 격자가 적용된 비정절 실리콘 평판형 검출기에서 초점-격자와 두부 팬텀의 중심 변위에 의한 화질 특성에 관한 연구)

  • Choi, Jun-Gu;Kim, Byeong-Gi;Cha, Seon-Hwa;Kim, Gyeong-Su
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.1
    • /
    • pp.7-15
    • /
    • 2007
  • This study aim to investigate image characteristics due to focus-grid and head phantom decentering from the armorphos silicon thin film transistor detector the fixed focus-grid is applied, wish to propose right use method of digital medical equipment. Acquired image according to focus-grid and head phantom position decentering using head phantom on armorphos silicon thin film transistor detector the fixed focus-grid is applied. acquired image evaluate pixel value, histogram, plot profile, surface plot using NIB (Image J) image analysis program and compared decentering image with standard image. Mean value and standard deviation value of focus-grid lateral decentering and duplex decentering of focus-grid and head phantom decreased by ratio, consequently increase of horizontality, diagonal decentering. also, deteriorated contrast of image because frequency of high pixel value decreases fairly. according increases decentering, image distortion phenomenon was increase, by next time, pixel mean value of head phantom decentering was no big change but horizontality, diagonal, mean value and standard deviation value of pixel decreased by ratio. Even if increase pixel noise of image because wide latitude and post processing ability of digital detector, radiotechnologist can not recognize. Therefore, radiotechnologist must recognize correctly the photographing factors which increases pixel noise on the grid system installation digital detector and should exam.

  • PDF

Modified Fold Type Helicone Reflector for Efficient Satellite TT&C Having Variable Coverage Area (가변 커버리지를 갖는 위성 관제용 접이식 헬리콘 반사체 안테나 성능 연구)

  • Lee, Sang-Min;Lee, Woo-Kyung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.9
    • /
    • pp.914-923
    • /
    • 2009
  • Helix antennas have been widely applied to satellite TT&C, data communication and GPS receiver systems onboard military, remote sensing and communication purpose satellites. The helix antennas are known to be convenient to control impedance and radiation coverage characteristics with a maximum directivity in satellite z-axis. Waveguide horn is commonly used for radar system that needs ultra-wideband pulse for exploration ground radar and electromagnetic disability measurement etc. It has high efficiency and low reflection characteristics provided by the low-profile shape and suppressed radiation distortion. In this paper, a waveguide horn structure incorporated with helix antenna design is proposed for satellite applications that require ultra-wideband pulse radar and high rate RF data communication link to ground station over wide coverage area. The main design concern is to synthesize variable beam forming pattern based on modified horn-helix combination helicone structure such that multi-mission antenna is implemented applicable for TT&C, earth observation, high data rate transmission. Waveguide horn helps to reduce the overall antenna structure size by introduction fold type reflector connected to the tapered helix antenna. The next generation KOMPSAT satellite currently under development requires high-performance precision attitude control system. We present an initial design of a hybrid hern-helix antenna structure suitable for efficient RF communication module design of multi-purpose satellite systems.

A Study on the Knowledge and Attitudes Towards Radiation Therapy and Cancer - A Questionnaire Survey of 142 Third Grade Medical Students - (방사선치료와 암에 대한 학생들의 단편적인 견해 - 한 의과대학 의학과 3학년 학생들을 대상으로 -)

  • Oh Yoon-Kyeong;Park Sang-Hag
    • Radiation Oncology Journal
    • /
    • v.17 no.2
    • /
    • pp.166-171
    • /
    • 1999
  • Purpose : To get the data for public information and education of medical students about radiation therapy (RT). Materials and Methods : We evaluated the knowledge and attitudes towards the RT and cancer in the third grade medical students who did not receive a lecture before starting the poly-clinic education about radiation oncology in our medical school, We obtained a total of 142 answers from the students that completed the questionnaire. Results : More than half of the third grade medical students answered 1 question correctly and 5 questions incorrectly among 6 questions about knowledge of RT. Incorrect answers were done about the frequency of RT, hair loss, the period of RT, re-RT, cost of RT, Fifty-six percent of students didn't wish to prolong the survival time from 1 year to 3 years with long courses of chemotherapy and RT. They had bad images about cancer of colorectum, lung, esophagus, liver, breast, cervix which consist of 56.3$\%$ of patients receiving RT. Conclusions : Public information about the basic points of RT should be considered. Also the students showed the pessimism about the anticancer treatments such as chemotherapy and RT, so the exact results and positive aspects of anticancer treatment should be educated more. Especially it is needed to inform the students and the public the positive aspects of RT in some cancers (colorectal, lung, esophageal, hepatic, breast, cervix cancers) which the students had bad images about.

  • PDF

Comparison of the Rate of Error with the Bisecting Angle Technique and the Paralleling Technique (등각촬영법과 평행촬영법에 따른 실책율 비교)

  • Lee, Yeong-Ae;Jo, Min-jung
    • Journal of dental hygiene science
    • /
    • v.4 no.3
    • /
    • pp.97-102
    • /
    • 2004
  • In order to find out the rate of error according to intraoral standard radiographic techniques, this study analyzed 3,251 standard films, and conducted a questionnaire with 120 Daegu Health College students who have used the bisecting angle technique and the paralleling technique. Followed are the results of the study: 1. The rate of error was the highest in canine from both maxilla and mandible when used by the bisecting angle technique. 2. The rate of error was the highest in premolar from both maxilla and mandible when used by the paralleling technique. 3. The technical error was occurred most frequently in elongation. 4. The rate of error and distortion was higher in the bisecting angle technique than in the paralleling technique. 5. The processing error was occurred most frequently in light film. 6. In applying radiographic techniques, the subjects indicated that the vertical angulation of central radiation in the bisecting angle technique and the oral fixation of film holder in the paralleling technique were the most difficult.

  • PDF