• Title/Summary/Keyword: 방사선 피폭관리

Search Result 238, Processing Time 0.03 seconds

Evaluation of Effective Dose with National Diagnostic Reference Level using Monte-Carlo Simulation (몬테카를로 시뮬레이션을 이용한 국내 일반엑스선검사 진단참고수준의 유효선량 평가)

  • Lee, Seung-Youl;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.1041-1047
    • /
    • 2021
  • In this study, the effective dose for frequently general radiography among the diagnostic reference level (DRL) for examinations provided by the government in Korea was evaluated using the Monte Carlo N-Particle eXtended (MCNPX) simulation tool. We were selected to evaluate for a total of 5 examination sites which included head anterior-posterior, chest (posterior-anterior, lateral), abdomen anterior-posterior and pelvis anterior-posterior. Physical conditions such as tube voltage and tube current used in MCNPX simulation were used in domestic conditions of the Korea Disease Control and Prevention Agency (KDCA). To evaluate domestic medical radiation exposure, we used the HDRK-Man computerized human phantom manufactured based on the international standard ICRP 103 that was applied to the MCNPX simulation. The phantom could represent the standard body shape of Koreans. As a results, the effective dose corresponding to the DRL based on adult males of head anterior-posterior position was 0.086 mSv, chest posterior-anterior position was 0.05 mSv, chest lateral was 0.354 mSv, abdomen anterior-posterior position was 0.548 mSv, and pelvis anterior-posterior position was 0.451 mSv.

A Study on the Analysis of Risk Factors and Correlations of Coronary Artery Disease of the Examinee taking Coronary Computed Tomography Angiography in a Comprehensive Health Improvement Center (종합검진 수검자의 관상동맥 전산화단층 혈관조영술 검사에서 관상동맥질환의 위험요인과 관련성 분석)

  • Choi, Min-Gyeong;Gwak, Jong-Hyeok;Kim, Gwang;Lee, Sam-Yol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.1005-1014
    • /
    • 2019
  • The purpose of this study is to evaluate the usefulness of coronary computed tomography angiography of coronary artery disease for the purpose fo health screening according to gender and age. In addition the association between hematological factors (Glucose, total cholesterol, visceral fat, body mass index, triglycerides, high density lipoprotein (HDL), low density lipoprotein (LDL)) and coronary artery disease is investigated. A retrospective analysis of coronary computed tomography angiography with 299 subjects showed that the detection rate of coronary artery disease was higher in men over 50 years of age and it was statistically significant. In particular, the prevalence rate of men (37.9%) was about 2 times higher than that of women (17.0%). Glucose and HDL as hematological factors associated with coronary artery disease were statistically significant. The prevention and management of coronary artery disease seems to require the control of glucose and high density lipoprotein (HDL). Although it is not statistically significant with other hematological factors, the need for management of coronary artery disease was identified. the coronary computed tomography angiography of coronary artery has higher radiation doses than other CT scans. Therefore, for the purpose of screening, coronary computed tomography angiography should be considered in consideration of the sex and age of the examinee, and detection of coronary artery disease through other non-invasive tests should be prioritized over coronary computed tomography angiography.

Study on Radioactive Material Management Plan and Environmental Analysis of Water (I) Study of Radioactive Substances in Water Management and Analysis to Eat of the US Environmental Protection Agency (Envirionmental Protection Agency) (물 환경의 방사성 물질 관리 방안과 분석법에 관한 연구 (I) 미국환경보호청(Envirionmental Protection Agency)의 먹는 물 방사성물질 관리와 분석법에 관한 고찰)

  • Her, Jae;Kim, Jung-Min;Min, Hye-Lim;Han, Seong-Gyu;Lim, Hyun-Jong;Jo, Han-Byeol;Noh, Young-Hoon;Lee, Ho-Sun;Park, Min-Suk
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.163-170
    • /
    • 2015
  • The interest of the people in the radioactive contamination of the water has increased significantly and the study about analysis and management of radioactive materials are being actively conducted. And monitoring spots have been expanded to the range of public water as well as drinking water by publishing the rule of drinking water quality standards and examination in the Environmental Enforcement Ordinance No. 553 of Korea. In this study, US EPA was investigated as the foreign advanced cases and the way that is appropriate for the Korea was sought by analyzing investigate radionuclide, interval and management. As a result, in the selection part of investigate radionuclide, geological survey, status of nuclear power plants and the presence of the use of artificial radionuclides of the Korea should be investigated and additionally after the selection of a few radionuclides, the systems should be extended to cover all possible radionuclides by considering radioactive pollution levels in humans may be exposed due to the annual drinking water. In the part of the investigate interval, the concept(MCL, DL) should be set up for preventing concentration detection of above MCL and it needs to the maintenance and management. For example, when the concentration is more than MCL, it should be investigated on a quarterly and when the concentration is lower than MCL, it should be investigated to each different interval and management. And the US EPA divided the management area and make the roadmap for managing drinking water. The each classified area has been organized to match the state budget and labor force and the individual data have been managed effectively by HPGe, the NaI, TLD and so on.

A Study on Mice Exposure Dose for Low-dose Gamma-irradiation Using Glass Dosimeter (유리선량계를 이용한 저선량 방사선의 마우스 피폭선량 연구)

  • Noh, Sung Jin;Kim, Hyo Jin;Kim, Hyun;Jeong, Dong Hyeok;Son, Tae Gen;Kim, Jung Ki;Yang, Kwangmo;Nam, Sang-Hee;Kang, Yeong-Rok
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.4
    • /
    • pp.202-210
    • /
    • 2015
  • The low dose radiation is done for a long period, thus researchers have to know the exact dose distribution for the irradiated mouse. This research has been conducted in order to find out methods in transmitting an exact dose to mouse in a mouse irradiation experiment carried out using $^{137}Cs$ irradiation equipment installed in the DIRAMS (Dongnam Institution of Radiological & Medical Sciences) research center. We developed a single mouse housing cage and shelf with adjustable geometric factors such as distance and angle from collimator. The measurement of irradiated dose showed a maximal 42% difference of absorbed dose from the desired dose in the conventional irradiation system, whereas only 6% difference of the absorbed dose was measured in the self-developed mouse apartment system. In addition, multi mice housing showed much difference of the absorbed dose in between head and body, compared to single mouse housing in the conventional irradiation system. This research may allow further research about biological effect assessment for the low dose irradiation using the self-developed mouse apartment to provide more exact doses which it tries to transmit, and to have more reliability for the biological analysis results.

Evaluation and Verification of the Attenuation Rate of Lead Sheets by Tube Voltage for Reference to Radiation Shielding Facilities (방사선 방어시설 구축 시 활용 가능한 관전압별 납 시트 차폐율 성능평가 및 실측 검증)

  • Ki-Yoon Lee;Kyung-Hwan Jung;Dong-Hee Han;Jang-Oh Kim;Man-Seok Han;Jong-Won Gil;Cheol-Ha Baek
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.489-495
    • /
    • 2023
  • Radiation shielding facilities are constructed in locations where diagnostic radiation generators are installed, with the aim of preventing exposure for patients and radiation workers. The purpose of this study is seek to compare and validate the trend of attenuation thickness of lead, the primary material in these radiation shielding facilities, at different maximum tube voltages by Monte Carlo simulations and measurement. We employed the Monte Carlo N-Particle 6 simulation code. Within this simulation, we set a lead shielding arrangement, where the distance between the source and the lead sheet was set at 100 cm and the field of view was set at 10 × 10 cm2. Additionally, we varied the tube voltages to encompass 80, 100, 120, and 140 kVp. We calculated energy spectra for each respective tube voltage and applied them in the simulations. Lead thicknesses corresponding to attenuation rates of 50, 70, 90, and 95% were determined for tube voltages of 80, 100, 120, and 140 kVp. For 80 kVp, the calculated thicknesses for these attenuation rates were 0.03, 0.08, 0.21, and 0.33 mm, respectively. For 100 kVp, the values were 0.05, 0.12, 0.30, and 0.50 mm. Similarly, for 120 kVp, they were 0.06, 0.14, 0.38, and 0.56 mm. Lastly, at 140 kVp, the corresponding thicknesses were 0.08, 0.16, 0.42, and 0.61 mm. Measurements were conducted to validate the calculated lead thicknesses. The radiation generator employed was the GE Healthcare Discovery XR 656, and the dosimeter used was the IBA MagicMax. The experimental results showed that at 80 kVp, the attenuation rates for different thicknesses were 43.56, 70.33, 89.85, and 93.05%, respectively. Similarly, at 100 kVp, the rates were 52.49, 72.26, 86.31, and 92.17%. For 120 kVp, the attenuation rates were 48.26, 71.18, 87.30, and 91.56%. Lastly, at 140 kVp, they were measured 50.45, 68.75, 89.95, and 91.65%. Upon comparing the simulation and experimental results, it was confirmed that the differences between the two values were within an average of approximately 3%. These research findings serve to validate the reliability of Monte Carlo simulations and could be employed as fundamental data for future radiation shielding facility construction.

A Study on Segmentation Process of the K1 Reactor Vessel and Internals (K1 원자로 및 내부구조물 절단해체 공정에 대한 연구)

  • Hwang, Young Hwan;Hwang, Seokju;Hong, Sunghoon;Park, Kwang Soo;Kim, Nam-Kyun;Jung, Deok Woon;Kim, Cheon-Woo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.4
    • /
    • pp.437-445
    • /
    • 2019
  • After the permanent shutdown of K1 in 2017, decommissioning processes have attracted great attention. According to the current decommissioning roadmap, the dismantling of the activated components of K1 may start in 2026, following the removal of its spent fuel. Since the reactor vessel (RV) and reactor vessel internal (RVI) of K1 contain massive components and are relatively highly activated, their decommissioning process should be conducted carefully in terms of radiological and industrial safety. For achieving maximum efficiency of nuclear waste management processes for K1, we present activation analysis of the segmentation process and waste classification of the RV and RVI components of K1. For RVI, the active fuel regions and some parts of the upper and lower active regions are classified as intermediate-level waste (ILW), while other components are classified as low-level waste (LLW). Due to the RVI's complex structure and high activation, we suggest various underwater segmentation techniques which are expected to reduce radiation exposure and generate approximately nine ILW and nineteen very low level waste (VLLW)/LLW packages. For RV, the active fuel region and other components are classified as LLW, VLLW, and clearance waste (CW). In this case, we suggest in-situ remote segmentation in air, which is expected to generate approximately forty-two VLLW/LLW packages.

Evaluation of the Accuracy for Respiratory-gated RapidArc (RapidArc를 이용한 호흡연동 회전세기조절방사선치료 할 때 전달선량의 정확성 평가)

  • Sung, Jiwon;Yoon, Myonggeun;Chung, Weon Kuu;Bae, Sun Hyun;Shin, Dong Oh;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.127-132
    • /
    • 2013
  • The position of the internal organs can change continually and periodically inside the body due to the respiration. To reduce the respiration induced uncertainty of dose localization, one can use a respiratory gated radiotherapy where a radiation beam is exposed during the specific time of period. The main disadvantage of this method is that it usually requests a long treatment time, the massive effort during the treatment and the limitation of the patient selection. In this sense, the combination of the real-time position management (RPM) system and the volumetric intensity modulated radiotherapy (RapidArc) is promising since it provides a short treatment time compared with the conventional respiratory gated treatments. In this study, we evaluated the accuracy of the respiratory gated RapidArc treatment. Total sic patient cases were used for this study and each case was planned by RapidArc technique using varian ECLIPSE v8.6 planning machine. For the Quality Assurance (QA), a MatriXX detector and I'mRT software were used. The results show that more than 97% of area gives the gamma value less than one with 3% dose and 3 mm distance to agreement condition, which indicates the measured dose is well matched with the treatment plan's dose distribution for the gated RapidArc treatment cases.

Comparative Analysis of Medical Terminology Among Korea, China, and Japan in the Field of Cardiopulmonary Bypass (한.중.일 의학용어 비교 분석 - 심폐바이패스 영역를 중심으로 -)

  • Kim, Won-Gon
    • Journal of Chest Surgery
    • /
    • v.40 no.3 s.272
    • /
    • pp.159-167
    • /
    • 2007
  • Background: Vocabularies originating from Chinese characters constitute an important common factor in the medical terminologies used 3 eastern Asian countries; Korea, China and Japan. This study was performed to comparatively analyze the medical terminologies of these 3 countries in the field of cardiopulmonary bypass (CPB) and; thereby, facilitate further understanding among the 3 medical societies. Material and Method: A total of 129 English terms (core 85 and related 44) in the field of CPB were selected and translated into each country's official terminology, with help from Seoul National University Hospital (Korea), Tokyo Michi Memorial Hospital(Japan), and Yanbian Welfare Hospital and Harbin Children Hospital (China). Dictionaries and CPB textbooks were also cited. In addition to the official terminology used in each country, the frequency of use of English terms in a clinical setting was also analyzed. Result and Conclusion: Among the 129 terms, 28 (21.7%) were identical between the 3 countries, as based on the Chinese characters. 86 terms were identical between only two countries, mostly between Korea and Japan. As a result, the identity rate in CPB terminology between Korea and Japan was 86.8%; whereas, between Korea and China and between Japan and China the rates were both 24.8%. The frequency of use of English terms in clinical practices was much higher in Korea and Japan than in China. Despite some inherent limitations involved in the analysis, this study can be a meaningful foundation in facilitating mutual understanding between the medical societies of these 3 eastern Asian countries.

Comparative Study on Biological Effects of Gamma-Radiation and Bisphenol A with Tradescantia Micronucleus Assay (자주달개비 미세핵 분석법을 이용한 비스페놀 에이 및 감마선의 생물학적 영향 비교 연구)

  • 신해식;송희섭;현성희;이진홍;김진규
    • Korean Journal of Environmental Biology
    • /
    • v.20 no.2
    • /
    • pp.158-164
    • /
    • 2002
  • Some of synthetic chemicals can net as an endocrine disrupting substance in higher animals. Dioxins, DDT, PCBs and bisphenol A (BPA) are classified into endocrine disruptors and aye under a strict control in many countries. This research was designed to compare the clastogenic effects of BPA to those of ionizng radiation to establish the relaltive effectiveness of BPA by means of Tradescantia micronucleus assay. For the uptake of the BPA through the stems, groups of fresh cuttings of Tradescantia BNL 4430 weve placed in BPA solutions of 0 to 4 $\mu$M for 6 hours under continuous aeration. The other groups of the cuttings were irradiated with 0 to 0.5 Gy of gamma- rays. The frequencies of micronucleus showed a positive dose- response relationship in the range of 0 to 0.5 Gy, and a clear concentration-response relationship in the experimental range of BPA concentrations. By comparing the two experimental results, it is possible to estimate the BPA concentration and its equivalent radiation dose for a fixed value of MCN frequency. BPA of $ll.8\mu{M}$ can give rise to 53.3 MCN/100 tetrads, which is the same frequency induced by 25 cGy of gamma- rays. It is of biological importance that clinical symptoms start to develop after a whole body exposure to radiation higher than 25 cGy. The results indicate that the pollen mother cells are an excellent biological end- point for toxicity test of suspected endocrine disrupting chemicals such as bisphenol A, cotylphenol and nonylphenol.

A Study for Effects of Image Quality due to Scatter Ray produced by Increasing of Tube Voltage (관전압 증가에 기인한 산란선 발생의 화질 영향 연구)

  • Park, Ji-Koon;Jun, Je-Hoon;Yang, Sung-Woo;Kim, Kyo-Tae;Choi, Il-Hong;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.663-669
    • /
    • 2017
  • In diagnostic medical imaging, it is essential to reduce the scattered radiation for the high medical image quality and low patient dose. Therefore, in this study, the influence of the scattered radiation on medical images was analyzed as the tube voltage increases. For this purpose, ANSI chest phantom was used to measure the scattering ratio, and the scattering effect on the image quality was investigated by RMS evaluation, RSD and NPS analysis. It was found that the scattering ratio with increasing x-ray tube voltage gradually increased to 48.8% at 73 kV tube voltage and to 80.1% at 93 kV tube voltage. As a result of RMS analysis for evaluating the image quality, RMS value according to increase of tube voltage was increased, resulting in low image quality. Also, the NPS value at 2.5 lp/mm spatial frequency was increased by 20% when the tube voltage was increased by 93 kV compared to the tube voltage of 73 kV. From this study, it can be seen that the scattering radiation have a significant effect on the image quality according to the increase of x-ray tube voltage. The results of this study can be used as basic data for the improvement of medical imaging quality.