• Title/Summary/Keyword: 방사선 증감제

Search Result 10, Processing Time 0.025 seconds

Hematological Change in Mice Injected with Radiosensitizer and Irradiated with High-dose Radiation (방사선 증감제를 투여한 마우스에 고 에너지 방사선 조사 후 혈액학적 변화에 관한 연구)

  • Ji, Yeon-Sang;Dong, Kyung-Rae;Jung, Myo-Young;Park, Yong-Soon;Dong, Cha-Bun;Ryu, Young-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.357-363
    • /
    • 2009
  • The current population of elderly is increasing and the with an extended average lifespan, the frequency of cancerous occurrences have also increased, with these increases and the increase in radiotherapy for cancer patients, recognitions of harm and importance have become known. This article was known tumor treatment of patients with hematopoietic disorder by doing a comparative study on the changes in blood cells caused by the acute effects of trace dose to high dose of radiation exposed to mice. According to the sensitizer injection may give rise to harm to the components of peripheral blood. This material needs to be considered when for treating tumor patients and the risks of hematopoietic harm and believe that radiation therapy will be reasonable.

A Synthesis of Iron Oxide Based and Gadolinium Oxide Based Radiosensitizer for the Therapeutic Enhancement of Proton Beam Cancer (양성자 빔 암치료효과 개선을 위한 산화철 및 산화가돌리늄 나노입자 기반의 방사선증감제 합성)

  • Kang, Bo Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.325-332
    • /
    • 2014
  • Metallic nanoparticles have attractive properties in biomedical applications such as diagnostics and therapeutics. Cross linked dextran coated iron oxide nanoparticles (SPIONs) and silica coated gadolinium oxide nanoparticles (SPGONs) have been synthesized as a radiosensitizer in the proton beam cancer therapy. The dextran and silicaused for the protective moieties on the SPIONs and SPGONs respectively. Size distributions of synthesized nanoparticles were confirmed 3~5 nm for SPIONs and 30~100 nm for SPGONs by transmission electron microscope (TEM). Cell survival fraction measurement and Western blot assay were performed to evaluate the radiosensitization effects of synthesized radiosensitizer. The calculated radiosensitization of SPIONs and SPGONs at 90 % cell death from the measured cell survival curves were 1.23 and 1.03 respectively. Western blotting results also show the same consistent results that the amount of released cytochrome c from mitochondria was considerably increased for the cancer cells taken up SPIONs.

TRAIL and Effect of Irradiation on Apoptosis of Cancer Cells (TRAIL과 방사선 조사가 암세포의 사멸에 미치는 효과)

  • Lee, Jaeseob;Jang, Seongjoo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.387-393
    • /
    • 2016
  • Tumor using the efficient concomitant radiotherapy and chemotherapy to remove, prior to surgery and, either reduce the size of the tumor after surgery, or was can be made smaller, Or excised tumor, in a way to be removed, most conventional surgical method is surgical excision surgery therapy. And methods reduce or tumor size, or smaller, chemotherapy can kill tumor is administered selectively anticancer agent which increases the radioactive susceptible to tumor cells, sensitive to susceptibility to radiation are those which make it possible to respond to, either TRAIL methods of various biological cytostatic can deform the protein, by deforming the structure of the protein help to cell death it is known. In this paper, the HCT-116 cells thought to be a cancer cell to analyze the interaction of TRAIL and radiation. Experimental results, single use of TRAIL and radiation, results were compared with the control group, it was found to have no significant effect on each cell proliferation and apoptosis. Conversely treated with TRAIL, when treated in parallel radiation, it was possible to know that the HCT-116 cells significantly apoptosis occurs, The proportion of G1 ratio G0 also was found to have increased. TRAIL conclusion is increased apoptosis radiation defensive cells can know that increased radiosensitivity, also possible to alter the cell cycle, reduce cell proliferation ability stepwise it was possible. TRAIL is increased apoptosis, decreased cell proliferative capacity, it is considered to be possible to use as a radiation sensitizer.

Hematological change in mice injected with radiosensitizer and irradiated with high-dose radiation (증감약제를 투여한 마우스에 고에너지 방사선 조사 후 혈액학적 변화에 관한 연구)

  • Jung, Myo-Young;Ji, Yeon-Sang;Dong, Kyung-Rae
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1136-1140
    • /
    • 2009
  • The current population of elderly is increasing and the with an extended average lifespan, the frequency of cancerous occurrences have also increased, with these increases and the increase in radiotherapy for cancer patients, recognitions of harm and importance have become known. This article was known tumor treatment of patients with hematopoietic disorder by doing a comparative study on the changes in blood cells caused by the acute effects of trace dose to high dose of radiation exposed to mice. According to the sensitizer injection may give rise to harm to the components of peripheral blood. This material needs to be considered when for treating tumor patients and the risks of hematopoietic harm and believe that radiation therapy will be reasonable.

  • PDF

Streptococcal Toxic Shock Syndrome Occurred during Postoperative Radiotherapy in a Cancer Patient with Preexisting Lymphedema and Chronic Illness -Case Report- (수술 후 림프부종과 만성질환을 동반한 종양 환자에서 방사선치료 기간 동안 발생한 연쇄구균독소충격증후군 예)

  • Jang, Ji-Young;Oh, Yoon-Kyeong;Kim, Dong-Min
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.317-321
    • /
    • 2006
  • A case is reported of a man with malignant fibrous histiocytoma (MFH) in right thigh who developed streptococcal toxic shock syndrome (STSS) during postoperative radiotherapy. Before radiotherapy, a patient complained wax and wane lymphedema following wide excision of tumor mass which was confirmed as MFH. He took some nonsteroidal antiinflammatory drug (NSAID) for about one month. He suffered preexisting hepatitis C virus (HCV) infection, diabetes and well-controlled hypertension. The patient received conventional radiotherapy to right thigh with a total dose of 32.4 Gy at 1.8 Gy per day. At last radiotherapy fraction, cutaneous erythematous inflammation was suddenly developed at his affected thigh. At that time, he also complained of oliguria, fever and chills. The patient was consulted to internal medicine for adequate evaluation and management. The patient was diagnosed as suggested septic shock and admitted without delay. At admission, he showed hypotension, oliguria, constipation, abnormal renal and liver function. As a result of blood culture, Streptococcus pyogenes was detected. The patient was diagnosed to STSS. He was treated with adequate intravenous antibiotics and fluid support. STSS is one of oncologic emergencies and requires immediate medical intervention to prevent loss of life. In this patient, underlying HCV infection, postoperative lymphedema, prolonged NSAID medication, and radiotherapy may have been multiple precipitating factors of STSS.

Efficacy of Small Bowel Displacement System in Post-Operative Pelvic Radiation Therapy of Rectal Cancer (소장 용적 측정을 통한 직장암의 수술 후 방사선치료 시 사용하는 소장 전위 장치(Small Bowel Displacement System : SBDS) 의 효용성 검토)

  • Ahn Yong Chan;Lim Do Hoon;Kim Moon Kyung;Wu Hong Gyun;Kim Dae Yong;Huh Seung Jae
    • Radiation Oncology Journal
    • /
    • v.16 no.1
    • /
    • pp.63-69
    • /
    • 1998
  • Purpose : This study is to evaluate the efficacy of small bowel displacement system(SBDS) in post-operative pelvic radiation therapy(RT) of rectal cancer patients by measurement of small bowel volume included in the radiation fields receiving therapeutic dose. Materials and Method : Ten consecutive new rectal cancer patients referred to the department of Radiation Oncology of Samsung Medical Center in May of 1997 were included in this study. All patients were asked to drink $Castrographin^(R)$ before simulation and were laid prone for conventional simulation and CT scans with and without SBDS. The volume of opacified small bowel on CT scans, which was to be included in the radiation fields receiving therapeutic dose, was measured using Picture archiving and communication system (PACS). Results : The average small bowel volumes with and without SBDS were 176.0ml(5.2-415.6ml) and 185.1ml(54.5-434.2ml), respectively The changes of small bowel volume with SBDS compared to those without SBDS were more than $10\%$ decrease in three, less than 10% decrease in two, less than $10\%$ increase in three, and more than $10\%$ increase in two patients. Conclusion : No significant advantage of using SBDS in post-operative pelvic RT for rectal cancer patients has been shown by small bowel volume measurement using CT scan considering additional effort and time needed for simulation and treatment setup.

  • PDF

Pretreatment characteristics of adolescents with Class II malocclusion treated by maxillary second molar extraction (상악 제2대구치를 발거하고 치료한 성장기 II급 부정교합 환자의 치료전 특성)

  • Kim, Jae-Hyung;Kim, Joeng-Il;Lim, Yong-Kyu;Lee, Dong-Yul
    • The korean journal of orthodontics
    • /
    • v.35 no.3 s.110
    • /
    • pp.182-195
    • /
    • 2005
  • The purpose of this retrospective study was to estimate the pretreatment characteristics of growing patients with Class II malocclusion. who had been treated with maxillary second molar extractions The sample comprised of 51 subjects; 18 subjects were classified into the molar extraction group, and 33 subjects were treated without extraction and classified into the nonextraction group. Pretreatment lateral cephalograms were calculated and analyzed by independent t-test and stepwise discriminant analysis. In measurements for skeletal pattern, no anteroposterior measurements and proportions of various vertical dimensions were significantly different. and only some measurements such as $AB-MP(^{\circ)$, Na-We(mm), AVD (mm) were significantly different between the two treatment groups (p<0.05). In measurements for dentoalveolar pattern. some measurements, which were related to the position and angulation of the upper and lower permanent first molars, and the angulation of the upper third molars, were significantly different between the two treatment groups In particular, the maxillary second molar extraction group exhibited more mesial angulation of maxillary first molar to the occlusal plane.

Radiotherapic Valuation of Paraffin Wax for Patients with Oral Cancer (구강암 환자 치료시 치과용 기초상 왁스(Paraffin Wax)의 유용성 평가)

  • Na, Kyoung-Su;Seo, Seuk-Jin;Lee, Je-Hee;Yoo, Sook-Heun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.41-49
    • /
    • 2011
  • Purpose: This study is designed to investigate radiotherapic valuation of Paraffin Wax, which is newly formed for this study and generally utilized in dentistry, and Mouth Piece and Putty impression, which are commonly used in radiotherapy, for oral cavity as a compensator. Materials and Methods: Each compensator was formed by $10{\times}10{\times}1cm$ and measured radiation dose attenuation ratio with reference of water phantom which is made of tissue-equivalent materials. Two patients with oral cancer underwent DRR (Digitally Reconstructed Radiogrph) of Offline Review Program of Aria System and Portal vision for 5 times for each material to evaluate reproducibility by each filling materials. Moreover, MU (monitor unit) changes by dose absorption were considered in the case of inevitable implication of an filling materials in the range for radiotherapy. Results: Radiation dose attenuation ratios were shown -0.7~+3.7% for Mouth Piece, +0.21~+0.39% for Paraffin Wax and -2.71~-1.76% for Putty impression. Error ranges of reproducibility of positions were measured ${\pm}3mm$ for Mouth Piece, ${\pm}2mm$ for Paraffin Wax and ${\pm}2mm$ mm for Putty impression. Difference of prescription MU from dose absorption with an filling material increased +7.8% (250 MU) in Putty impression and -0.9% (230 MU) in Paraffin Wax as converted into a percentage from the standard phantom, Water 232 MU. Conclusion: Dose reduction of boundary between cavity and tissue was observed for Mouth Piece. Mouth Piece also had low reproducibility of positions as it had no reflection of anatomy of oral cavity even though it was a proper material to separate Maxilla and Mandible during therapy. On the other hand, Putty impression was a suitable material to correctly re-position oral cavity as before. However, it risked normal tissues getting unnecessary over irradiation and it caused radiation dose decrease by -2.5% for 1cm volume in comparison of it of water phantom. Dose reduction in Paraffin Wax, Fat Tissue-Equivalent Material, was smaller than other impressions and position reproducibility of it was remarkable as it was possible to make an anatomy reflected impression. It was also well fitted to oral cavity to transfer radiation dose planned in radiotherapy. Thus, Paraffin Wax will be an ideal material in radiotherapy for patients with oral cancer.

  • PDF

The Study of Technical Error Analysis on BMD Using DEXA (이중 에너지 X선 흡수 계측법을 이용한 BMD 검사 시 발생할 수 있는 기술적인 오류 분석)

  • Kang, Yeong-Han;Jo, Gwang-Ho
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.229-236
    • /
    • 2006
  • Purpose: This study was conducted to search for the type of technical error in DEXA(dual-energy X-ray absorptiometry) and the effect of error to measurement of BMD. Materials and Methods: The changes of BMD($g/cm^2$, T-score) by patients information(Age, Weight, Height, Manopause age) input error and Confirming ROI error were investigated. Using spine phantom, we canned 10 times by age(5, 10), weight(10, 20 kg), height(5, 10 cm), manopause age(5, 10) increase & decrease respectively. Scanning region(L-spine, femur, Forearm) of 10 patients was calculated by changing ROI respectively. Analysis of difference for mean(precision 1%) were carried out. Results: The error of patient information(Age, Weight, Height, Manopause age) was not changed differently. In confirming ROI, the BMD and T-score of L-spine involving T-12 was decreased to $0.063\;g/cm^2$, 0.3 and involving L-5 increased to $0.077\;g/cm^2$, 0.5. In narrowing 1 cm of vertical line of ROI, the BMD and T-score decreased to $0.006\;g/cm^2$, 0.1 and in 2 cm, $0.021\;g/cm^2$, 0.15, each. In hip ROI, Upper and left shift(0.5 cm) of line was not influenced BMD and T-score. In 0.5 cm lower shift(lesser trochanter below), the BMD and T-score increased $0.031\;g/cm^2$, 0.3 and in 1 cm $0.094\;g/cm^2$, 0.65, each. In forearm ROI, the BMD and T-score decreased $0.042\;g/cm^2$, 0.9 involving 1 cm lower wrist. And expanding 1 cm of vertical line, the BMD and T-score decreased $0.008\;g/cm^2$, 0.1 and in 2 cm, $0.021\;g/cm^2$, 0.3, each. The L-spine, hip, forearm ROI error was changed differently. Conclusion: There are so many kinds of technical error in BMD processing. Errors according to age, weight, height, manopause age did not influent to $BMD(g/cm^2)$ and T-score. There are mean differences BMD and T-score in confirming ROI. For the precision exam, in L-spine processing, L1-4 have to confirmed without shift of ROI vertical line. In hip processing, the ROI have to included greater trochanter, femur head and lesser trochanter. In forearm processing, the ROI have to included wrist, radius and ulnar.

  • PDF

Effects of $^{60}Co-gamma$ Radiation on Ricebran Oil (미강유에 대한 코발트 60-감마선의 영향에 관한 연구)

  • Han, Deok-Bong;Suck, Han-Gyun;Yoo, Young-Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.129-135
    • /
    • 1973
  • The accumulation of peroxides, acid values, and carbonyl values during irradiation and post-irradiation storage of the ricebran oil has been studied. The rice bran oils were irradiated two doses of 2 and 7 megarads (300 rads/sec) at $23^{\circ}C$ atmospheric circumstance. The acid values, peroxide values and carbonyl values were measured at regular intervals of one week during the storage at $5^{\circ}C$ and $25^{\circ}C$. 1) During the storage, the acid values of the irradiated rice bran oils increased or decreased insignificantly regardless of the addition of antioxidants and storage temperature. 2) The peroxide values were not increased continuously but increased zigzag. The result was indicated that the composition and decomposition of peroxides occurred continuously throughout the storage. 3) As the peroxide values increased, carbonyl values decreased and changed quite differently, but, especially in 7th week, they were constant or insignificant. 4) Dibutylhydroxytoluene is more effective than caffeic acid in retarding the formation of peroxides during irradiation of rice bran oils and post-irradiation storage. The effect of antioxidant is more efficient at 2 megarads than at 7 megarads irradiation. When we store the rice bran oil, the addition of antioxidants of post-irradiation is more desirable than that of preirradiation. 5) In spite of changing conditions such as storage temperature and addition of antioxidants, the peroxide values of rice bran oils irradiated at 2 megarads were always greater than those at 7 megarads during the storage. Peroxide values of samples at high temperature $(25^{\circ}C)$ storage increased as twice as those of low temperature $(5^{\circ}C)$ storage samples. At low temperature, peroxide values in the first week increased twice during the period of 8th weeks storage, but those did from three to four times at higher temperature in the same period Therefore, the low temperature storage is recommandable too.

  • PDF