• Title/Summary/Keyword: 방사선 밀도

Search Result 280, Processing Time 0.034 seconds

Analysis of the Relationship between Abdominal Ultrasound Based Kidney Stones, Obesity and Metabolic Syndrome (복부 초음파 검사 기반 신장결석과 비만 및 대사증후군 관련성 분석)

  • Kim, Ju Hee;Jang, Hyon Chol;Cho, Pyong Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.495-502
    • /
    • 2020
  • Kidney stones are a common disease with an annual prevalence of about 30,000 people in Korea, and are deeply related to an increase in chronic kidney disease, high blood pressure, coronary artery disease, metabolic syndrome, type 2 diabetes, hyperlipidemia, and abdominal obesity. Therefore, in this study, 135 examinees who visited a general hospital in Dalseong-gun from May 2019 to June 2020 for a medical examination were examined. The relationship between kidney stones and factors related to obesity and metabolic syndrome were found in abdominal ultrasound. I tried to find out the relevance. As a result of the study, the risk of kidney stones in the abnormal group was increased by 4.255 times compared to the normal group in total cholesterol factor, and the risk of kidney stones in the abnormal group was increased by 2.072 times compared to the normal group in the low-density lipoprotein cholesterol factor. Total cholesterol factor and low-density lipoprotein cholesterol It was found that the factor affects the prevalence of kidney stones and metabolic syndrome. Since the risk of kidney stones is related to total cholesterol and low-density lipoprotein cholesterol factors, active attention should be paid to preventive purposes through health check-ups.

Evaluation of Corrected Dose with Inhomogeneous Tissue by using CT Image (CT 영상을 이용한 불균질 조직의 선량보정 평가)

  • Kim, Gha-Jung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.75-80
    • /
    • 2006
  • Purpose: In radiation therapy, precise calculation of dose toward malignant tumors or normal tissue would be a critical factor in determining whether the treatment would be successful. The Radiation Treatment Planning (RTP) system is one of most effective methods to make it effective to the correction of dose due to CT number through converting linear attenuation coefficient to density of the inhomogeneous tissue by means of CT based reconstruction. Materials and Methods: In this study, we carried out the measurement of CT number and calculation of mass density by using RTP system and the homemade inhomogeneous tissue Phantom and the values were obtained with reference to water. Moreover, we intended to investigate the effectiveness and accuracy for the correction of inhomogeneous tissue by the CT number through comparing the measured dose (nC) and calculated dose (Percentage Depth Dose, PDD) used CT image during radiation exposure with RTP. Results: The difference in mass density between the calculated tissue equivalent material and the true value was ranged from $0.005g/cm^3\;to\;0.069g/cm^3$. A relative error between PDD of RTP and calculated dose obtained by radiation therapy of machine ranged from -2.8 to +1.06%(effective range within 3%). Conclusion: In conclusion, we confirmed the effectiveness of correction for the inhomogeneous tissues through CT images. These results would be one of good information on the basic outline of Quality Assurance (QA) in RTP system.

  • PDF

Verification of the Protective Effect of Functional Shielding Cream for the Prevention of X-ray Low-dose Exposure (X-ray 저선량 피폭방지를 위한 기능성 차폐크림의 방어 효과 검증)

  • Seon-Chil Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.497-506
    • /
    • 2023
  • In the case of radiation workers in medical institutions, radiation exposure is made for patient protection and accurate procedures, so they have a problem of low dose exposure. Low-dose radiation exposure occurs mainly in parts of the body other than the Apron area, and the most frequent place is the skin of the back of the hand. In particular, since the medical personnel's hands require senses and fine movements during the procedure, they are defenseless in the radiation exposure area and are at risk of exposure. It can solve the problem of shielding such as lead gloves, and it is difficult to use by suggesting the activity of the hand during the procedure. To solve this problem, a shielding cream capable of obtaining a functional radiation protection effect was developed and its shielding performance was compared with lead equivalent of 0.1 mmPb. In the process of manufacturing shielding cream, the shielding performance was improved by adding a defoaming process to reduce air holes to increase the density of the cream. Therefore, the shielding cream using barium sulfate as the main material has a lower shielding rate than the lead plate, and in the realm of effective energy, it is 59%, At high effective energy, a difference of about 37% was shown, indicating that there is a functional radiation protection effect. The advantage is that it can be used directly on the skin, and it is considered that it can be used before wearing surgical gloves and has a permanent protective effect.

Rapidly and Accurately Processing of Low Melting Block for Shielding of Radiotherapy (방사선(放射線) 치료(治療)의 신속정확(迅速正確)을 위한 저온용융(低溫熔融) 차폐물(遮蔽物)의 제작(製作)과 응용(應用))

  • Chu, S.S.;Lee, D.H.;Park, C.Y.
    • Journal of Radiation Protection and Research
    • /
    • v.4 no.1
    • /
    • pp.14-20
    • /
    • 1979
  • For accurate and easily shielding irregular shaped organ, its minimized penumbra region and a low melting point alloy 'Lead Y' and synchronizing instrument have been developed. The 'Lead Y' is the quaternary eutectic alloy and it is composed of Lead 30.0% Tin 11.5% Bismuth 48 5% Cadmium 10.0% The density of its at $22^{\circ}C$ is $9.8g/cm^3$ and the melting temperature has $40^{\circ}C\;to\;68^{\circ}C$. The thickness of 'Lead Y' for perfect shielding of Co-60 gamma ray and LINAC 10MeV x-ray is 6cm and 7cm respectively. The 'Lead Y' shielding block is casted directly on the styrofoam from which is cut with hot wire of synchronizer device. The special features and advantages of the Lead Y shielding block could be summarized as follows; 1. The shielding block for radiotherapy is rapidly processed only with boiling water and styrofoam. 2. It is not injure one's health and not danger of a fire, because of not generating of any metals vapor and evil smelling. 3. It is very effective to minimize secondary penumbra for the protection of healthy tissue from unnecessary ionizing radiation regardless of the magnification source to skin distance. 4. The HVL of the Lead Y is 1.2cm for Co-60 gamma ray and it's shielding effect is almost same as the pure lead block. 5. The hardness of Lead Y is 1.5 times higher than lead block. 6. It's reavailability is higher than lead block and then one block of Lead Y is reavailable about 30 to 40 times. 7. It is usefull for shielding of x-ray, gamma ray, beta-ray, electron and neutron radiation. 8. The materials for Lead Y are easy to acquire with reasonable price and tractable.

  • PDF

Design of Neutron Shielder for Reducing Background of Low Level Gamma Ray Spectrometer (극저준위 감마선 분광시스템의 백그라운드 저감화를 위한 중성자 차폐체 설계)

  • Kim, Tae-Wook;Park, Jong-Mook;Park, Jong-Gil;Shin, Sang-Woon;Jun, Jae-Shik
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.2
    • /
    • pp.67-71
    • /
    • 2001
  • In order to shield the neutrons affecting the background of Low Level Gamma Ray Spectrometer, a neutron shielder was designed. The method used in this study for neutron shielding was the deceleration of fast neutrons by high density polyethylene(HDPE) and the absorption of those slowing-down neutrons by $B_4C$. The calculation results of neutron Interaction in HDPE using Monte Carlo simulation code MCNP4B showed that the thermal-neutron flux was maximum at 10 cm thickness of HDPE. The results also showed that 95% of the thermal neutrons were absorbed by 2 mm thickness of $B_4C$ absorber Consisted of 30 w% $B_4C$ and 70 w% polymer. The results of the Monte Carlo calculation were in good agreement with the experimental value obtained by a neutron shielding apparatus designed for this purpose.

  • PDF

The system design for contents measurement of density and moisture in compaction (성토의 밀도 및 수분 함량을 측정하기 위한 시스템 설계)

  • 김기준
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.7 no.4
    • /
    • pp.37-45
    • /
    • 2002
  • In this study, to measure the density and moisture of compaction, it is designed to use the 2 neutron and 5 gamma-ray detectors. Also, it can be know that Co-60 gamma-ray and Cf-252 neutron source are more useful for this system, because discharge of radiation are better than other sources. They are more profitable to improve their accuracy. Especially, to remove the interference of their reciprocal action between neutron and gamma-ray detectors it is designed shield materials with lead between 2 neutron and 5 gamma-ray detectors each other. It is performed the optimal design to shield under the suggested values completely. Because this system will use portable, so decrease of their weight are so important. For this reason, it can be decrease their weight of 5.2[kg] with shield material between each detectors and it can be think mote easy to carry and use on the industrial Spot.

  • PDF

Analysis of Attenuation Differences According to Radiolucent and Radiopague Materials : Based on DECT (Dual Energy Computed Tomography) (방사선 투과 및 불투과성 물질에 따른 감약 차이의 분석 : DECT 검사 중심으로)

  • Jang, Hyon-Chol;Kim, Yoon-Shin;Kim, Hyeon-Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1584-1589
    • /
    • 2014
  • This study analyzed CT values of radiolucent and radiopaque materials by energy region after selecting radiolucent and radiopaque materials at random using GE's DECT((Dual Energy Com-puted Tomography) at S University Hospital located in Gyeonggi-province from July through August in 2013. Besides, it drew out the most analogous energy region to the value of 120kVp CT, which is applied to existing SECT(Single Energy Computed Tomography), by utilizing the analysis method of CT values and tried to find out the most useful and appropriate materials when contrast was applied within visible area in clinical application. As a result, there was little decrease of CT value after 90KeV in the case of materials with low density and high moisture content such as normal saline, methyl-cellulose and gels used in ultra-sonic waves test; energy does not influence much on materials with extremely low or high density such as air and contrast medium; methyl-cellulose and gels used in ultra-sonic waves test are considered to be the most useful materials for clinical applications.

Improvement of Genetic Algorithm for Evaluating X-ray Reflectivity on Multilayer Mirror (다층박막 거울의 반사율 평가를 위한 유전 알고리즘의 개선)

  • Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.69-75
    • /
    • 2020
  • Multilayer mirrors have widely been used not only in the industry but also in the medical field. X-ray reflectivity was measured by X-ray diffractometer to evaluate the performance of W/C multilayer mirror with 40 layers. Genetic algorithm are used to obtain thickness, density, and interfacial roughness for each of the 40 layers. The existing uniform random selection causes a problem that the solution does not converge or the error increases even if it convergence. To reduce the time to calculate the fitness of the genetic algorithm, the genetic algorithm was written in C/C++ parallel programming. The genetic algorithm showed excellent scalability of linear time increase with increasing number of generation and population. The genetic algorithm was selected with uniform and Gaussian randomness of 1:1 to improve the convergence of solution. The improved genetic algorithm can be applied to characterize each layer of a sample with more than a few tens of layers, such as a multilayer mirror.

In vivo Radioprotective Effects of Basic Fibroblast Growth Factor in C3H Mice (Basic Fibroblast Growth Factor (bFGF)의 방사선보호작용에 대한 실험적 연구)

  • Kim, Yeon-Shil;Yoon, Sei-Chul
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.253-263
    • /
    • 2002
  • Purpose : In order to understand in vivo radiation damage modifying of bFGF on jejunal mucosa, bone marrow and the effect of bFGF on the growth of transplanted mouse sarcoma 180 tumor in mice. Materials and Methods : Mice were treated with $6\;{\mu}g$ of bFGF at 24 hours and 4 hours before exposing to 600 cGy, 800 cGy and 1,000 cGy total body irradiation (TBI), and then exposed to 3,000 cGy local radiation therapy on the tumor bearing thigh. Survival and tumor growth curve were plotted in radiation alone group and combined group of bFGF and irradiation (RT). Histologic examination was performed in another experimental group. Experimental groups consisted of normal control, tumor control, RT (radiation therapy) alone, $6\;{\mu}g$ bFGF alone, combined group of $3\;{\mu}g$ bFGF and irradiation (RT), combined group of $6\;{\mu}g$ bFGF and irradiation (RT). Histologic examination was peformed with H-E staining in marrow, jejunal mucosa, lung and sarcoma 180 bearing tumor. Radiation induced apoptosis was determined in each group with the DNA terminal transferase nick-end labeling method ($ApopTag^{\circledR}$ S7100-kit, Intergen Co.) Results : The results were as follows 1) $6\;{\mu}g$ bFGF given before TBI significantly improved the survival of lethally irradiated mice. bFGF would protect against lethal bone marrow syndrome. 2) $6\;{\mu}g$ bFGF treated group showed a significant higher crypt depth and microvilli length than RT alone group (p<0.05). 3) The bone marrow of bFGF treated group showed less hypocellularity than radiation alone group on day 7 and 14 after TBI (p<0.05), and this protective effect was more evident in $6\;{\mu}g$ bFGF treated group than that of $3\;{\mu}g$ bFGF treated group. 4) bFGF protected against early radiation induced apoptosis in intestinal crypt cell but might have had no antiapoptotic effect in bone marrow stem cell and pulmonary endothelial cells. 5) There was no significant differences in tumor growth rate between tumor control and bFGF alone groups (p>0.05). 6) There were no significant differences in histopathologic findings of lung and mouse sarcoma 180 tumor between radiation alone group and bFGF treated group. Conclusions : Our results suggest that bFGF protects small bowel and bone marrow from acute radiation damage without promoting the inoculated tumor growth in C3H mice. Improved recovery of early responding normal tissue and reduced number of radiation induced apoptosis may be possible mechanism of radioprotective effect of bFGF.

Comparative Analysis of Medical Terminology Among Korea, China, and Japan in the Field of Cardiopulmonary Bypass (한.중.일 의학용어 비교 분석 - 심폐바이패스 영역를 중심으로 -)

  • Kim, Won-Gon
    • Journal of Chest Surgery
    • /
    • v.40 no.3 s.272
    • /
    • pp.159-167
    • /
    • 2007
  • Background: Vocabularies originating from Chinese characters constitute an important common factor in the medical terminologies used 3 eastern Asian countries; Korea, China and Japan. This study was performed to comparatively analyze the medical terminologies of these 3 countries in the field of cardiopulmonary bypass (CPB) and; thereby, facilitate further understanding among the 3 medical societies. Material and Method: A total of 129 English terms (core 85 and related 44) in the field of CPB were selected and translated into each country's official terminology, with help from Seoul National University Hospital (Korea), Tokyo Michi Memorial Hospital(Japan), and Yanbian Welfare Hospital and Harbin Children Hospital (China). Dictionaries and CPB textbooks were also cited. In addition to the official terminology used in each country, the frequency of use of English terms in a clinical setting was also analyzed. Result and Conclusion: Among the 129 terms, 28 (21.7%) were identical between the 3 countries, as based on the Chinese characters. 86 terms were identical between only two countries, mostly between Korea and Japan. As a result, the identity rate in CPB terminology between Korea and Japan was 86.8%; whereas, between Korea and China and between Japan and China the rates were both 24.8%. The frequency of use of English terms in clinical practices was much higher in Korea and Japan than in China. Despite some inherent limitations involved in the analysis, this study can be a meaningful foundation in facilitating mutual understanding between the medical societies of these 3 eastern Asian countries.