The system design for contents measurement of density and moisture in compaction

성토의 밀도 및 수분 함량을 측정하기 위한 시스템 설계

  • Published : 2002.12.01

Abstract

In this study, to measure the density and moisture of compaction, it is designed to use the 2 neutron and 5 gamma-ray detectors. Also, it can be know that Co-60 gamma-ray and Cf-252 neutron source are more useful for this system, because discharge of radiation are better than other sources. They are more profitable to improve their accuracy. Especially, to remove the interference of their reciprocal action between neutron and gamma-ray detectors it is designed shield materials with lead between 2 neutron and 5 gamma-ray detectors each other. It is performed the optimal design to shield under the suggested values completely. Because this system will use portable, so decrease of their weight are so important. For this reason, it can be decrease their weight of 5.2[kg] with shield material between each detectors and it can be think mote easy to carry and use on the industrial Spot.

본 연구에서는 다짐 성토의 밀도 및 수분을 측정하기 위해서 중성자 검출기는 2개 그리고 감마선 검출기는 5개를 사용하여 설계하였고, 또한 방사능 대비 방사선 방출수가 다른 선원에 비하여 우수한 Co-60 감마선원과 Cf-252 중성자 선원을 본 시스템에 이용하는 것이 정밀도를 향상시키기 위하여 유리하다는 것을 알 수 있었다. 특히 중성자와 감마선의 상호 반응으로 인한 간섭을 제거하기 위하여 2개의 중성자와 5개의 감마선 검출부 사이에 차폐체인 납을 각각 설치하였으며, 제시된 기준값 이하로 완전히 차폐하기 위한 최적 설계를 수행하였다. 이러한 최적 선계에 의하여 휴대용으로 사용될 본 시스템은 각 검출부 사이에 차폐체를 설치함에 따라 5.2[kg]의 무게를 경감할 수 있었고, 이는 산업 현장에서 쉽게 이동하고 간편하게 사용될 수 있을 것으로 사료된다.