• Title/Summary/Keyword: 방사선 노출

Search Result 457, Processing Time 0.027 seconds

Effects of Dose Reduction Fiber Shielding Cloth on Scattering Rays in Off-target Site during Angiography (선량저감섬유(Dose Reduction Fiber) 차폐포의 혈관조영술(Angiography) 시술 시 비 시술 부위의 산란선 차폐 효과)

  • Kim, Yong-Jin;Han, Sang-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.393-400
    • /
    • 2020
  • Unlike conventional radiographic examinations, angiointerventional procedures have a high risk of radiation exposure to patients or operators due to prolonged radiation exposure time. This study was undertaken to examine effects of reducing the radiation risk by applying dose reduction fiber (DRF) shielding cloth during angiography. To investigate the properties of DRF shielding cloth, we measured the scattered radiation below and above a human phantom using a glass dosimeter, at site distances 10 cm away from the irradiated field. The results obtained reveal a 15 ~ 31% reduction of scattered radiation in the irradiation field, and 53 ~ 70% reduced radiation measured after phantom transmission. Taken together, our data indicate that application of DRF shielding cloth for radiation reduction at non-procedural sites during interventional procedure results in reduction of scattered doses to patients and operators, without affecting the medical examinations. We propose the use of DRF shielding during angiointerventional procedures, in order to reduce the risk of radiation exposure of patients and operators.

Development of Radiation Shield with Environmentally-Friendly Materials ; Ⅰ: Comparison and Evaluation of Fiber, Rubber, Silicon in the Radiation Shielding Sheet (친환경 소재의 의료 방사선 차폐 시트 개발 ; I: 섬유, 고무, 실리콘 소재 차폐 시트의 성능 비교평가)

  • Kim, Seon-Chil;Park, Myeong-Hwan
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.121-126
    • /
    • 2010
  • Traditionally, lead has been primarily used to shield the radiation in the hospital, because of its soft texture, durability and cost effectiveness. However, lead can be dangerous because of its toxicity when exposed to the human body, and it is classified as a heavy metal like cadmium, mercury, and arsenic etc. In order to compensate its noxious properties on the human body, researchers are trying to develop a radiation shield which has similar shielding efficiency and can also be manufactured in any form. In this study, sulfuric acid barium was mixed with fiber, rubber, and silicon all of which are harmless to the human body, tested, and evaluated for its ability of medical radiation shield. The result of this study showed that the sheet containing silicon and barium has the strongest shielding abilities.

Assessment of Occupational Dose to the Staff of Interventional Radiology Using Monte Carlo Simulations (몬테카를로 방법을 이용한 중재방사선시술자에 대한 선량평가)

  • Lim, Young-Khi
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.213-217
    • /
    • 2014
  • Medical operations and diagnosis using interventional radiology techniques have been increased. The management and monitoring of occupational radiation exposure to the staff of interventional radiology become important, specially because they stand in close proximity to the patient. The operational radiation protection quantity, Hp(10) which can be obtained from personal dosimeter do not always represent the effective dose to the staff. So, in this study, to estimate the critical organ doses to the staff of interventional radiology, Monte Carlo calculations with mathematical human phantom and dose measurements with personal dosimeters were carried out for the major interventional radiology procedures using C-arm. Results showed that the values of Hp(10) measured by personal dosimeters were higher than critical organ doses which were calculated. And the calculated dose to thyroids was much higher than those of other critical organ doses. For the proper radiation protection of the medical staff of interventional radiology, additional radiation protection for thyroids as well as for whole body shielding like wearing a lead apron should be considered.

프린팅 월드 1-미국의 UV인쇄

  • Jo, Gap-Jun
    • 프린팅코리아
    • /
    • s.24
    • /
    • pp.152-157
    • /
    • 2004
  • 미국의 매엽 전문 이노새사들이 양질의 품질로 보담하는 UV인쇄에 매료되는 데는 많은 이유가 있다. 먼저, UV인쇄에 사용되는 공식 잉크들은 경화되거나 장기 보존처리를 위해 인쇄물 표면이 UV방사선에 노출되는 결과를 통해 시각적으로는 고광택을 발휘하며 이 외에도 은은한 코팅, 빛나는 색깔, 살아있는 섬세함, 심지어 현재 인기가 오르고 있는 비코팅 매엽 인쇄물까지 잘 표현하고 있다. 물론 여기에는 잉크가 즉시 경화된다는 사실이 전해진다.

  • PDF

인체보호기준에 대한 각국의 동향

  • 백정기
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.2
    • /
    • pp.2-11
    • /
    • 1997
  • 최근 국내에서도 전자파의 인체 영향에 대해 많은 관심이 집중되고 있다. 본 고에서는 전자파(또는 전자계)와 인체와의 기본적인 상호작용 메카니즘, 인체보호기준 설정시 고려되는 일반적인 사항, 인체의 노출 기준치에 대한 이론적인 근거에 대해 살펴보고, 미국, 유럽, 일본, 국제방사선 보호협회 등 서구권 주요국 및 주요 기관의 인체보호기준을 비교, 분석하였다.

  • PDF

A Study on the Health Risk Agents in the Workplace of a General Hospital (한 종합병원 작업환경의 건강저해인자에 관한 조사 연구)

  • Kim, Yang-Ok;Kim, Ki-Soon;Park, Jong;Ryu, So-Yeon;Yang, Hee-Yeon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.1 s.52
    • /
    • pp.1-14
    • /
    • 1996
  • To evaluate the health risk of the workplace environment of a general hospital toward the hospital workers, a questionnaire survey on the perception of risk at the workplace environment and environmental measurements at 27 locations with 240 workers in the hospital were made from October 25th, 1993 to October 30th, 1994. The results were as follows ; 1. By the environmental measurements, 86 workers(36%) were found to be exposed to poor or harmful degree of general illumination, 193 workers(80%) were exposed to poor or harmful local illumination, 34 workers(14%) were exposed to poor or harmful degree of thermal condition and 180 workers(75%) were exposed to poor or harmful noise level, but nobody was exposed to poor or harmful dust and toluene concentration. Also nobody was exposed to poor or harmful level of radiation or anticancer/antibiotic agents. 2. The subjective perceptions on the environmental conditions felt by the workers were different from the objective findings by the environmental measurements. The workers underscored the poor illumination state and overscored the dust concentrations. Also workers oversensitized about the thermal condition, the noise level, the radiation level, the toluene concentration and anticancer/antibiotic agents 3. The sources of noise were the dialogue(179 workers) and the office instruments(131 workers). The sources of dust came from the clothes(108 workers) and the building materials(79 workers). 4. The questionnaire survey showed that the 28 workers were exposed to poor or harmful level of the antibiotics, 10 workers to alkali or acid and 6 workers to drug dust in the pharmacy but the above findings could not be proved by the environmental measurements.

  • PDF

Performance Test for Automatic Exposure Control by Zone System (Zone System을 이용한 자동노출장치의 성능 측정에 관한 실험)

  • Kang, Hee-Doo;Pyo, Chang-Gi;Cha, Jung-Hee;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.21 no.2
    • /
    • pp.57-63
    • /
    • 1998
  • AEC was designed to assist in the production of radiographs of equal density and to aid in the production f consistently high quality radiographs. Many improvements have been made in the AEC and these have helped to increase it's acceptance. Newer system (Falling load) control kVp and mA as well as exposure time. Authors have had experiments about the characteristics of AEC by Zone System. Zone System is the method to detection of photographic image qualify by control the photo print from Fred Archer and Ansel Adams. With the Zone System theory the experiments of density control, characteristics of phantom thickness and reproducibility of occupation rate of contrast media could make quality control of X-ray photography effectively in falling load system.

  • PDF

Effects of Gamma Irradiation on Array Type Fiber Bragg Grating Sensors (배열형 FBG 센서의 감마선 영향)

  • Kim, Jong-Yeol;Lee, Nam-Ho;Jung, Hyun-Kyu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.937-939
    • /
    • 2016
  • In this study, we studied the gamma-radiation effect of fiber Bragg gratings (FBGs) manufactured by array sensors. The array FBGs were fabricated in a different Bragg wavelength using the same commercial Ge-doped fiber and exposed to gamma-radiation up to a dose of about 100 kGy at the dose rate of 113 Gy/min. It was analyzed radiation effects by measuring the radiation-induced change in the temperature sensitivity coefficient and Bragg wavelength shift after irradiation.

  • PDF

Preliminary Study on Applicability of Accumulate Personal Neutron Dosimeter for Cosmic-ray Exposure of Aviators (운항승무원의 우주방사선 피폭 평가에 있어 누적형 개인 중성자 선량계의 적용가능성 예비 연구)

  • Kim, Hyeong-Jin;Chang, Byung-Uck;Byun, Jong-In;Song, Myeong Han;Kim, Jung-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.1
    • /
    • pp.44-51
    • /
    • 2013
  • ICRP recommended that cosmic ray exposure to the pilot and cabin crew would be considered as an occupational exposure due to their relatively high exposure. Since 2012 with the Act No. 10908 (Natural radiation management), the guideline of cosmic ray exposure to the pilot was established in Korea. The applicability of the solid-state nuclear track detector for personal dose assessment of pilot and cabin crew was evaluated. Dose linearity and angle dependence of dosimeters to the neutron were evaluated by $^{252}Cf$ neutron emitting source. The track density has a good agreement with the dose ($r^2$=0.99) and highly dependent on the degree of an angular of the dosimeter to the neutron source. In addition, the dosimeters (SSNTD) were exposed to cosmic ray in an aircraft during its cruising for more than two months in collaboration with Airline Pilots Association of Korea. Although the correlation between the track density from aircraft cruising altitude and expected neutron dose is low, however RSNS dosimeter could be used for personal neutron dosimeter. For application of RSNS as a personal dosimeter for pilot and cabin crew, additional studies are required.

Evaluation of Image Quality and Stability of Radiation Output according to Change in Tube Voltage and Sensitivity when Abdomen and Pelvis Examination of Digital Radiography (DR) (디지털 방사선 시스템(DR)의 복부와 골반부 검사 시 관전압과 감도 변화에 따른 영상 화질과 방사선 출력의 안정성 평가)

  • Hwang, Jun-Ho;Yang, Hyung-Jin;Choi, Ji-An;Lee, Kyung-Bae
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.12
    • /
    • pp.517-526
    • /
    • 2019
  • The purpose of this study is to find the optimal method for clinical application by analyzing image quality and radiation output according to parameter combination when using the Automatic Exposure Control (AEC). The experimental method combines 70, 81 kVp with sensitivity S200, S400, S800 and S1000 of the Automatic Exposure Control for Entrance Surface Dose (ESD), current volume, Signal to Noise Ratio (SNR), Contrast to Noise Ratio (CNR), Time-to-Radiation Dose Curve in abdomen and pelvis. And then, image quality and radiation output stability were evaluated. As a results, Entrance Surface Dose, current volume, Signal to Noise Ratio, Contrast to Noise Ratio decreased as the tube voltage and sensitivity were set higher. In addition, the higher tube voltage and sensitivity, the Time-to-Radiation Dose Curve showed a poor output stability. In conclusion, the higher the combination of tube voltage and sensitivity in the use of Automatic Exposure Control, the more problems can be seen in image quality and stability of the radiation output. Therefore, a relatively low combination of tube voltage and sensitivity showed that the image quality and radiation output stability could be optimized by minimizing the error range that would occur when the detector recognized a combination of parameters.