• Title/Summary/Keyword: 방사선 내구성

Search Result 16, Processing Time 0.023 seconds

Radiation Resistance Evaluation of Thin Film Transistors (박막트랜지스터의 방사선 내구성 평가)

  • Seung Ik Jun;Bong Goo Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.625-631
    • /
    • 2023
  • The important requirement of industrial dynamic X-ray detector operating under high tube voltage up to 450 kVp for 24 hours and 7 days is to obtain significantly high radiation resistance. This study presents the radiation resistance characteristics of various thin film transistors (TFTs) with a-Si, poly-Si and IGZO semiconducting layers. IGZO TFT offering dozens of times higher field effect mobility than a-Si TFT was processed with highly hydrogenated plasma in between IGZO semiconducting layer and inter-layered dielectric. The hydrogenated IGZO TFT showed most sustainable radiation resistance up to 10,000Gy accumulated, thus, concluded that it is a sole switching device in X-ray imaging sensor offering dynamic X-ray imaging at high frame rate under extremely severe radiation environment such as automated X-ray inspection.

A Study on Radiation-Shielded Electronics Technology Survey (우주방사선차폐 전자공학기술조사 연구)

  • Hwang, Sun-Tae;Hah, Suck-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.1
    • /
    • pp.45-49
    • /
    • 2001
  • 오늘 날 인공위성을 이용하는 통신, 방송, 기상, 환경모니터링 및 원격탐사 등이 각광을 받고 있는 때에 위성에 설치되는 수많은 전자제품 및 부품들의 우주방사선에 대한 내구성이 매우 중요한 문제로 제기되고 있다. 이러한 관점에서 국내에서는 아직 확보할 수 없는 우주방사선차폐 전자공학기술에 관한 정보자료를 조사 수집하여 기술적으로 직접 활용해야할 필요성이 시급하게 대두되고 있다. 따라서 선진국에서 개발된 우주방사선차폐를 위한 첨단전자공학기술에 관한 기술정보 자료를 체계적으로 서술한다.

  • PDF

Trends of Technologies for High Performance Polymer Barriers against Radiation (고성능 방사선 고분자 차단막 기술동향)

  • Lee, Gi-Bbeum;Park, Sung-Eun;Kim, In-Woo;Jeong, Kwang-Un;Lee, Hong-Ki;Nah, Chang-Woon
    • Elastomers and Composites
    • /
    • v.46 no.2
    • /
    • pp.94-101
    • /
    • 2011
  • The conventional radiation barriers may show some disadvantages such as heavy weight and possibility of poisoning human bodies because they are composed of lead plates or resin plates containing large amounts of lead powders. Another disadvantage may be direct penetration of radiation through small pin holes. In this article, technologies of multi-layered polymer barriers against radiation, which has been extensively focused recently, will be introduced. A new concept of radiation protection as well as improving endurance with employing nano-layered inorganic particles is introduced.

Corrosion-Inhibition and Durability of Polymer-Modified Mortars Using Bisphenol A and F Type Epoxy Resin with Calumite (비스페놀 A 및 F형 에폭시수지와 칼루마이트를 병용한 폴리머 시멘트 모르타르의 방청성 및 내구성)

  • Kim, Joo-Young;Kim, Wan-Ki
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.517-524
    • /
    • 2014
  • Nitrite-Type hydrocalumite (calumite) is a material that can adsorb chloride ions ($Cl^-$) that cause corrosion of reinforce bars and liberate the nitrite ions ($NO_2{^-}$) that inhibit corrosion in reinforced concrete. In this study, polymer-modified mortars using two types of epoxy resin with calumite are prepared with various polymer binder-ratios of 0, 5, 10, 15, 20% and calumite contents of 0, 5%. The specimens are tested for chloride ion penetration, carbonation, drying shrinkage and corrosion inhibition. As a result, the chloride ion penetration and carbonation depth of PMM using epoxy resin somewhat increases with increasing calumite contents, but those remarkably decreases depending on the polymer-binder ratios. The 28-d drying shrinkage shows a tendency to decrease with increasing polymer-binder ratio and calumite content. Unmodified mortars with calumite content of 5% did not satisfy quality requirement by KS. However, it was satisfied with KS requirement by the modification of epoxy resin in cement mortar. On the whole, the carbonation and chloride ion penetration depth of epoxy-modified mortars with calumite is considerably improved with an increase in the polymer-binder ratio regardless of the calumite content, and is remarkably improved over unmodified mortar. And, the replacement of the portland cement with the calumite has a marked effect in the corrosion-inhibiting property of the epoxy-modified mortars.

새로 개발된 Cement

  • 한국양회공업협회
    • Cement
    • /
    • s.59
    • /
    • pp.26-38
    • /
    • 1975
  • 본고는 일본 소야전Cement Co.의 중앙연구소주임연구원으로 있는 Hiroshi Uckikawa 박사가 일본의 Ceramics-Japan지(''74.10)에 기고한 것을 번역한 것으로서 그 내용에 의한 목차는 다음과 같다. 즉 근년에 개발된 새로운 cement로서는 1. 속경성 cement 2) 초속경 cement(jet cement, regulated set cement) 2) Alumina cement 3) 초조강 cement 4) 급경 cement 2. 고강도 cement 3. 내구성 cement 1) 내유산균 cement 2) 내화 cement (1) alumina cement 계 (2) barium, strontium 계 cement (3) 인산 aluminium 계 cement 3) 방사선차폐용 cement 4. 팽창 cement 1) alumine 산, 유산 calcium 수화물의 생성에 의한 것 2) 수산화 calcium의 생성에 의한 것 3) 기타 5. 시공성을 개선한 cement (예: 유정용 cement, 도장용 cement) 등이 있다. 머지 않아 우리나라에서도 cement 품종의 다양화가 필연적인 문제로 대두될 것을 생각하여 본번역문이 다소나마 도움이 되기를 바란다.

  • PDF

Heteroepitaxial Growth of ZnO Thin Films by PLD (레이저증착법을 이용한 ZnO 이종에피탁시 박막성장)

  • 박재영;이병택;김상섭;이재목;제정호
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.113-113
    • /
    • 2003
  • ZnO 박막은 p형 도핑방법이 점차 알려 지면서 최근 차세대 발광소자 재료로서 주목을 받고 있으며, 우수한 전자 이동도, 우수한 홀 이동도, 발광 스펙트럼(PL) 피크의 날카로움, 높은 free exciton binding energy, 방사선 노출에 대한 큰 내구성, 습식 식각이 가능, 동종 기판 사용이 가능함으로써 박막의 품질을 개선할 수 있고 제조공정을 간소화할 수 있는 등의 장점을 지니고 있어 이에 관련된 많은 연구들이 진행되고 있다. 특히 ZnO 박막을 차세대 발광소자로 응용하기 위해서는 고품질의 에피탁시 박막을 성장시켜야 하며 이를 위하여 MBE, MOCVD, PLD법 등 다양한 에피탁시 박막증착이 시도되고 있다. 또한 보다 양질의 ZnO 박막을 성장시키기 위해 적절한 단결정 기판 및 버퍼층의 탐색과 각 기판에 따른 ZnO 박막의 물성평가 작업도 진행되고 있다.

  • PDF

Design of Radiation Hardened Shift Register and SEU Measurement and Evaluation using The Proton (내방사선용 Shift Register의 제작 및 양성자를 이용한 SEU 측정 평가)

  • Kang, Geun Hun;Roh, Young Tak;Lee, Hee Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.8
    • /
    • pp.121-127
    • /
    • 2013
  • Memory devices including SRAM and DRAM are very susceptible to high energy radiation particles in the space. Abnormal operation of the devices is caused by SEE or TID. This paper presents a method to estimate proton SEU cross section representing the susceptibility of the latch circuit that the unit cell of the SRAM and proposes a new latch circuit to mitigate the SEU. 50b shift register was fabricated by using the conventional latch and the proposed latch in $0.35{\mu}m$ process. Irradiation experiment was conducted at KIRAMS by using 43MeV proton beam. It was found that the proposed latch-shift register is not affected by the radiation environment compared to the conventional latch-shift register.

Evaluation on the Stability of Solidified Waste Forms (방사성고화체의 물리화학적 안정성 평가)

  • 유영걸;김기홍;홍권표;정의영;고덕준
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.60-70
    • /
    • 2003
  • The stability of various waste forms to meet waste acceptance criteria was evaluated by using standard test methods of U.S.A and France. Compressive strength of waste forms were above 176.03 kgf/$\textrm{cm}^2$(cement), 15 kgf/$\textrm{cm}^2$(paraffin). In the thermal cycling test, there were no any change in their feature and volume, the loss of weight was 6.15% on the average. In the immersion test for 120 days, the loss of weight of paraffin waste form was 8.85-5.14% pH=3.83. The G-Value of $H_2$ and $CH_4$ in paraffin wax at $10^8rads$ rads of exposure dose were 2.65, 0.016.

  • PDF

Design of accelerated life test on temperature stress of piezoelectric sensor for monitoring high-level nuclear waste repository (고준위방사성폐기물 처분장 모니터링용 피에조센서의 온도 스트레스에 관한 가속수명시험 설계)

  • Hwang, Hyun-Joong;Park, Changhee;Hong, Chang-Ho;Kim, Jin-Seop;Cho, Gye-Chun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.451-464
    • /
    • 2022
  • The high-level nuclear waste repository is a deep geological disposal system exposed to complex environmental conditions such as high temperature, radiation, and ground-water due to handling spent nuclear fuel. Continuous exposure can lead to cracking and deterioration of the structure over time. On the other hand, the high-level nuclear waste repository requires an ultra-long life expectancy. Thus long-term structural health monitoring is essential. Various sensors such as an accelerometer, earth pressure gauge, and displacement meter can be used to monitor the health of a structure, and a piezoelectric sensor is generally used. Therefore, it is necessary to develop a highly durable sensor based on the durability assessment of the piezoelectric sensor. This study designed an accelerated life test for durability assessment and life prediction of the piezoelectric sensor. Based on the literature review, the number of accelerated stress levels for a single stress factor, and the number of samples for each level were selected. The failure mode and mechanism of the piezoelectric sensor that can occur in the environmental conditions of the high-level waste repository were analyzed. In addition, two methods were proposed to investigate the maximum harsh condition for the temperature stress factor. The reliable operating limit of the piezoelectric sensor was derived, and a reasonable accelerated stress level was set for the accelerated life test. The suggested methods contain economical and practical ideas and can be widely used in designing accelerated life tests of piezoelectric sensors.

Development of Environmental Safety Real-Time Monitoring System by Living Area (생활권역별 환경안전 실시간 모니터링 시스템의 개발)

  • Lee, Joo-Hyun;Kim, Joo-Ho;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.1088-1091
    • /
    • 2019
  • In this paper, a real-time monitoring system for environmental safety by living area is proposed. The proposed system is designed to measure radiation, fine dust and basic living information (temperature) using fixed and mobile measuring equipment, and constitutes a web database that stores data received from the equipment. It also develops web programs for displaying received data on PCs and mobile phones. The results of testing the performance of the system by an authorized testing agency showed that the radiation measurement range was measured in the range of $10{\mu}Sv/h$ to 10mSv/h, which is comparable to the world's highest level, and that the accuracy was measured between ${\pm}6.7$ and ${\pm}8.7$ percent of the measurement uncertainty was measured and normal operation at or below the international standard of ${\pm}15$ percent. In addition, the temperature test was conducted on a section of $-20^{\circ}C$ to $50^{\circ}C$ and normal operation was confirmed in response to the temperature change. Stability of radiated electromagnetic waves was ensured by a suitable judgment. The product's testing in general and high and low temperature environments for about four months after the prototype was made confirmed to be more than five years of durability. The measurement range and accuracy of fine dust sensors are compared with those of companies that measure the air environment, and the performance level is similar through the air quality measurement register.