• Title/Summary/Keyword: 방사선 과피폭

Search Result 363, Processing Time 0.025 seconds

A Study on the Distribution of Scatter Ray in Chest Radiography of a Health Examination Bus (건강검진 차량 내 흉부 방사선검사 시 공간산란선 분포 연구)

  • Cho, Ji-Hwan;Jin, Seong-jin;Min, Byeong-In
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.377-383
    • /
    • 2017
  • The purpose of this study was to evaluate the distribution of spatial scatter ray on the chest radiographs of patients on health examination bus. In this paper, we propose a method for minimize unnecessary exposure by measuring the scattered dose after exposure the actual subject and comparing the body mass index (BMI) with the tube current amount mAs. The results of this study showed that the mean BMI of the subjects was $23.31{\pm}3.12$. The mean mAs value was $2.92{\pm}1.19$, which males was higher than females. The mean value of the scatter ray at position 1 in the radiography room was $771.81{\pm}151.15{\mu}Sv/hr$. The mean value of the scatter rays at the position 2 outside the entrance of the radiography room was measured as $53.86{\pm}25.66{\mu}Sv/hr$. As the BMI and mAs was increase the spatial scatter dose was increased at position 1 and position 2 in the photographing room. In order to minimize the exposure dose of scatter ray, radiation workers should shoot the radiation as low as possible within the range that does not impair the quality of the image. It will be necessary to make efforts to not wait for a waiting person near the entrance door of the photographing room.

Reduction of Exposure Dose of Mammography by Comparison of Compression Paddle Material (압박대 재질 비교를 통한 유방촬영의 피폭선량 감소 방안)

  • Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.455-460
    • /
    • 2019
  • This study compared the radiation transmission and image quality of polymethylmethacrylate (PMMA), polycarbonate (PC), and carbon, which are common components of the compression plates currently used during breast imaging. In addition to measuring the transmitted dose and the intensity without the use of a compression paddle, the four different compression paddles were evaluated according to the material and thickness of each paddle. Radiation transmittance, maximum intensity, and plot profile type w ere all evaluated for each material, and for each factor evaluated the follow ing order w as noted, from best to w orst: carbon 4 mm, PMMA 3 mm, PMMA 4 mm, and PC 4 mm. It is necessary to study a variety of materials and thicknesses in order to find the optimal combination of material and thickness, because not only does the material have a large influence in reducing the radiation exposure during mammography, but the thickness of the compression plate also has a great influence.

Evaluation of Radiation Exposure to Medical Staff except Nuclear Medicine Department (핵의학 검사 시행하는 환자에 의한 병원 종사자 피폭선량 평가)

  • Lim, Jung Jin;Kim, Ha Kyoon;Kim, Jong Pil;Jo, Sung Wook;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.32-35
    • /
    • 2016
  • Purpose The goal for this study is to figure out that medical staff except Nuclear Medicine Department could be exposed to radiation from the patients who take Nuclear Medicine examination. Materials and Methods Total 250 patients (Bone scan 100, Myocardial SPECT 100, PET/CT 50) were involved from July to October in 2015, and we measured patient dose rate two times for every patients. First, we checked radiation dose rate right after injecting an isotope (radiopharmaceutical). Secondly, we measured radiation dose rate after each examination. Results In the case of Bone scan, dose rate were $0.0278{\pm}0.0036mSv/h$ after injection and $0.0060{\pm}0.0018mSv/h$ after examination (3 hrs 52 minutes after injection on average). For Myocardial SPECT, dose rate were $0.0245{\pm}0.0027mSv/h$ after injection and $0.0123{\pm}0.0041mSv/h$ after examination (2 hrs 09 minutes after injection on average). Lastly, for PET/CT, dose rate were $0.0439{\pm}0.0087mSv/h$ after examination (68 minutes after injection on average). Conclusion Compared to Nuclear Safety Commission Act, there was no significant harmful effect of the exposure from patients who have been administered radiopharmaceuticals. However, we should strive to keep ALARA(as low as reasonably achievable) principle for radiation protection.

  • PDF

The Protective Effects of Black Garlic Extract for Blood and Intestinal Mucosa to Irradiation (방사선 조사 시 혈구 및 장점막에 대한 흑마늘 추출물의 보호효과)

  • Jung, Do-Young;Choi, Junhyeok;Kim, Joongsun;Choi, Hyeongseok;Bae, Minji;Park, Wonsuk;Min, Byungin
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.19-26
    • /
    • 2016
  • The radiation has been utilized in a number of fields, even though the use of plenty cause a variety of side effects. This study was confirmed for radiation protective effects of aged garlic to contribute to the prevention of disasters that are radiation exposure. We studied the Complete Blood cell Count(CBC) and the small intestine after feeding aged garlic extract into Sprague Dawley Rat which irradiated X-ray beam 7 and 13 Gy. Garlic extract was administered to the results in the experimental group showed a notable difference in the CBC of platelets (p<0.05), red blood cells (p<0.05) and early damaged white blood cells (p<0.05). In addition, it was confirmed that experimental group's small intestine crypt is more survival than irradiation group significantly. And experimental group has small intestine villi length almost similar to the normal group. result of the aged garlic study will be able to be of great benefit for the radiation relevant emergency management.

Research on the Actual Condition of Mammograpgy and Space Scattered Dose in Mammography Room (유방촬영의 실태와 유방촬영실의 공간산란선량에 관한 조사 연구)

  • Lee, In-Ja;Park, Kye-Yeon;Kim, Sung-Soo
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.21-28
    • /
    • 2006
  • I made inquires about mammographic equipments and circumstances of mammography rooms in the 64 medical facilities in areas of Seoul and Kyong Gi Do. Moreover I had experments about exposure dose with patients and radiologic technologists. so there is the data indicated follows. 1. There are inclined to improve in quality and function of mammographic equipments, it has been proven that s/f system exchanged to DR system. 2. It is certain that the number of examinations are becoming increasingly significant. 3. The Space Scattered Dose of mammography rooms are much more larger than portable equipments. 4. I worry about the affection of expose dose about Space Scattered Dose of mammography room. 5. There is need of study how to cope with the situation about increasing exposure dose of radiologic technologists in small space and numeruous number of examinations.

  • PDF

Terms Standardization between the Rules of Diagnosis Radiation Equipment Safety Management and Atomic Energy Law : Problems and Suggestions (진단용 방사선발생장치의 안전관리에 관한 규칙과 원자력법의 용어통일 개선 방향)

  • Kim, Hwa-Gon;Kang, Se-Sik;Kim, Chang-Soo;Park, Cheol-Seo
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.39-46
    • /
    • 2006
  • The rules and terms are described different meaning, in this results the research is accomplished for preventing practical workers from confusion. Atomic law are kept up modification and development in our situation by the ICRP's recommendation, on the other hand, the rules of diagnosis radiation equipment safety managements are modified partial, then resulted in confusion. The study was comparison between the rules of diagnosis radiation equipment safety management and atomic energy law, and the modification items obtained were as follows. 1. With each other different the terms and units are used. With the exception of special terms for affairs usage, it is needless to say that common term uniformity is standardized. The standardization of rules and guidance have not need to confusion radiological practical workers. 2. The following is omitted. 1) The radiation protection against tile patient and the hospital visitor. 2) Radiation dose limit of the woman patient who is in the process of becoming pregnant. 3) Radiation dose limit of the person who is not regarded as madical madical exposure. 4) The control of the exposure of pregnant of women at work.

  • PDF

Evaluation of Patient Exposure Dose during Cardiac Electrophysiology Study under Various Conditions (심장 전기생리학 검사 시 조건 변화에 따른 환자 피폭 선량 평가)

  • Seong-Bhin Koh;Sung-Min Ahn
    • Journal of radiological science and technology
    • /
    • v.46 no.6
    • /
    • pp.501-508
    • /
    • 2023
  • This study used a adult absorption dose phantom (CIRS model 701-G, USA) made of human equivalent material and the vascular imaging equipment Allura Xper FD 20 (Philips, Netherlands). Optically stimulated luminescent dosimeters (OSLD) were inserted into the anatomical positions corresponding to each organ, and the exposure dose was measured. Dose area product (DAP) and air kerma (AK) measured by the dose meter in the equipment were compared. Continuous imaging was performed at two angles for a total of 20 minutes, with a frame per seconds of 3.75 and 7.5 fps and an FOV of 42 cm, 37 cm, and 31 cm, respectively, under the conditions of fluoflavor I, II, and III, each selected for 5 repetitions. This study was found that selecting a lower fps was the most effective way to reduce patient exposure dose, and adjusting the fluoflavor was a good alternative method for reducing patient exposure dose at high fps. Therefore the method of condition change with the greatest dose reduction effect is to set the minimum FPS and can reduce patient exposure dose according to geometric conditions and fluoflavor characteristics.

A Study on the Exposure Parameter and the Patient Dose for Digital Radiography System in Dae Goo (디지털 방사선의학에서의 조사선량 설정과 인지에 대한 실태 - 대구 경북지역을 중심으로 -)

  • Jo, Gwang-Ho;Kang, Yeong-Han;Kim, Bu-Sun
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.177-182
    • /
    • 2008
  • Digital imaging for general rediography has many advantages over the film/screen systems, including a wider dynamic range and the ability to manipulate the images produced. The wider range means that acceptable images may by acquired at a range of dose levels, and therefore repeat exposures can be reduced. Digital imaging can result in the over use of radiation, however, because there is a tendency can be reduced. Digital imaging can result in the over use of radiation, however, because there is a tendency for images to be acquired at too high a dose. We investigated the actual exposure dose conditions on general radiography and a questionnaire survey was conducted with radiotechnologiest at medical institutions using digital radiology system. As a results, the dose of exposure was not controlled with patient's figure and dose optimization but was controlled by worker's convenience and image quality. Radio-technologiests often set up the exposure dose regardless of patient figure and body part to be examined. Many organizations, such as the International Commission on Radiological Protection, recommend to keep the dose as low as possible. In addition, they strongly recommend to keep the optimal but minimal dosage by proper training programs and constant quality control, including frequent patient dose evaluations and education.

  • PDF

Analysis of Radiation/Radioactivity-Related Knowledge, Perception and Behaviors of Radiological Technologists (방사선사의 방사선/능에 대한 지식, 인식, 행위 분석)

  • Kim, Jung-Hoon;Ko, Seong-Jin;Kang, Se-Sik;Choi, Seok-Yoon;Kim, Chang-Soo
    • Journal of radiological science and technology
    • /
    • v.34 no.2
    • /
    • pp.123-129
    • /
    • 2011
  • This study aimed at 1) investigating the perception, knowledge and behaviors of radiological technologists on radiation defence and 2) preparing plans to reduce the unnecessary radiation dose on practician, patients and their caretakers. For data collection, a structured questionnaire was used to survey 225 radiological technologists living in downtown Busan. To analyze the collected data, SPSS/PC+ Win 13 version was used. For verification of differences between groups, one-way ANOVA was conducted. In addition, multiple regression analysis was conducted to analyze the impact of general variables (knowledge, education, age and length of service) in radiation safety management perspective. No differences were found in terms of the knowledge on radiation/radioactivity according to educational background, age and length of service. In the perspective of radiation safety management, the highest figures were found among those in their 40s and higher and those with the education of college graduation and higher. As for the correlation between radiation safety management and knowledge on radiation/radioactivity, positive correlations were found in all cases. In addition, analysis on the impact of general variables in radiation safety management perspective indicated that the perception on radiation safety management was higher as the level of knowledge on radiation/radioactivity was higher. The correct radiation/radioactivity management through practician training was necessary to reduce radiation dose on radiological technologists and patients.

General Radiography Usage and Exposure Dose of Korean Elderly: Based on Data from Aged Patients in 2016 (한국 노인의 일반촬영 이용량 및 피폭선량: 2016년 고령환자데이터 기반)

  • Gil, Jong-Won;Yoo, Se-Jong;Lee, Won-Jeong
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.495-502
    • /
    • 2021
  • This study aims to provide basic data for elderly health insurance policy and medical radiation safety management by analyzing the general radiography usage and exposure dose of the elderly in Korea. The effective dose for each general radiography was calculated using the ALARA-GR program for 260 general radiography codes selected from 'National Health Insurance Care Benefit Cost'. The usage of general radiography was analyzed in the 2016 elderly patient data of the Health Insurance Review and Assessment Service, and the effective dose for each general radiography was applied. The general radiography usage and exposure dose per person aged 65 years and over was 6.47 cases and 0.56 mSv. Females showed higher value than males as 7.15 cases and 0.66 mSv(p<.001). By age, those between 75 and 79 showed the highest number as 6.97 cases and 0.62 mSv(p<.001). Those who were supported by Medical Aid showed higher value than those who were insured by National Health Insurance as 8.82 cases and 0.76 mSv(p<.001). In addition, the ratio by radiography was in the order of Chest 20.85%, Knee Joint 15.58%, and L-spine 14.67%, and the exposure dose was L-spine 29.40%, Chest 15.82%, Abdomen 7.97%, and Entire Spine 7.20%. General radiography, which is widely used due to the high frequency of diseases in the elderly population should be taken into consideration when establishing health insurance policies. In addition, it is necessary to check whether the general radiography with high exposure dose is performed as a routine examination without considering medical necessity.