• Title/Summary/Keyword: 방사선학적 중재적 시술

Search Result 10, Processing Time 0.029 seconds

Efficacy of a Protective Grass Shield in Reduction of Radiation Exposure Dose During Interventional Radiology (방사선학적 중재적 시술시 납유리의 방사선 방어효과에 관한 연구)

  • Jang, Young-Ill;Song, Jong-Nam;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.303-308
    • /
    • 2011
  • Background/Aims : The increasing use of diagnostic and therapeutic interventional radiology calls for greater consideration of radiation exposure risk to radiologist and radiological technician, and emphasizes the proper system of radiation protection. This study was designed to assess the effect of a protective grass shield. Methods : A protective grass was following data depth, 0.8 cm; width, 100 cm; length, 100 cm, lead equivalent, 1.6 mmPb. The protective shield was located between the patient and the radiologist. Thirty patients (13 male and 17 female) undergoing interventional radiology between September 2010 and December 2010 were selected for this study. The dose of radiation exposure was recorded with or without the protective grass shield at the level of the head, chest, and pelvis. The measurement was made at 50 cm and 150 cm from the radiation source. Results : The mean patient age was 69 years. The mean patient height and weight was $159.7{\pm}6.7$ cm and $60.3{\pm}5.9$ kg, respectively. The mean body mass index (BMI) was $20.5{\pm}3.0$ kg/m2. radiologists received $1530.2{\pm}550.0$ mR/hr without the protective lead shield. At the same distance, radiation exposure was significantly reduced to $50.3{\pm}85.2$ mR/hr with the protective lead shield (p-value<0.0001). The radiation exposure to radiologist and radiological technician was significantly reduced by the use of a protective lead shield (p value <0.0001). The amount of radiation exposure during interventional radiology was related to the patient' BMI (r=0.749, p=0.001). Conclusions : This protective shield grass is effective in protecting radiologist and radiological technician from radiation exposure.

Effects of Single Vessel PCI (Percutaneous Coronary Intervention) using DCR (Dynamic Coronary Road map) on Fluoroscopy Time and Patient Radiation (동적 심혈관 로드맵을 이용한 중재적 시술이 투시 시간 및 환자 피폭에 미치는 영향)

  • Jong-Gil Kwak;Young-Hyun Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.551-556
    • /
    • 2023
  • Angiography equipment is used to evaluate and treat coronary artery disease. As a common feature of equipment, radiation is used, and function development for dose reduction is being carried out by each company. Therefore, the difference depending on whether DCR installed in angiography equipment is used is analyzed from a radiological point of view to prove the effect. Among 431 patients who underwent coronary artery intervention from March 2021 to February 2023, 250 patients with retrospective data were selected. And than among the 250 subjects obtained, 91 patients used the cardiovascular roadmap function during single-vessel intervention, and 159 patients did not use the roadmap. When DCR was used, total dose area product (34.57 uGy/m2 : 69.15 uGy/m2), total air kerma dose (688.47 mGy : 1640.4 mGy), fluoroscopy dose (23.87 uGy/m2 : 49.91 uGy/m2) and fluoroscopy time (723.55 s : 366.03 s), total number of images (17 : 26) showed lower values and were statistically significant than those not used. The use of DCR function in single vessel coronary intervention is thought to be radiologically safer as single vessel coronary intervention using dynamic cardiovascular DCR showed lower perspective time and perspective dose than procedures performed without the DCR.

The Clinical Comparative Investigation of Endovascular Treatment Using GDC and Neurosurgical Operation's Decision for Intracranial Aneurysm (뇌동맥류에 대한 방사선학적 중재적 시술과 신경외과학적 수술 선택의 임상적 비교 고찰)

  • Kim Sang Jin;Go Jung Seok;You Sang Jae;Kim Gyeong Sul;Choi Kwang Nam;Lee Yong Woo
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.28 no.1
    • /
    • pp.90-96
    • /
    • 2002
  • Purpose : The purpose of this study is to compare and analyze matters related to procedure such as characteristics and conditions etc. of intracranial aneurysm of patients who were treated GDC(Guglielmi Detachable Coil : Endovascular Treatment) and patien

  • PDF

Dose Assessment of the Eye of the Operator in the Field of Angiography and Interventional Radiography (혈관조영 및 중재적 시술 분야 내 종사자의 눈에 대한 선량평가)

  • Kim, Jung-hoon;Cho, Yong-In
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.209-216
    • /
    • 2018
  • In the field of angiography and interventional radiology, it is said that the risk of radiation exposure to the eyes is high due to the characteristics of work, but currently divided dose assessment and management are not carried out in reality. Therefore, in this study, in order to evaluate the dose of the operator in the surgical environment and to analyze the shields, firstly, we selected the point where the operator is mainly located, evaluated the exposure dose of the eye after attaching the pocket dosimeter to the lateral angle point of the head and neck phantom, and evaluate shielding effect when wearing lead glasses that is currently commercialized. Secondly, we evaluated the tendency of the exposure dose of the eye and the shielding effect through simulation in the same geometric structure as the actual measurement. As a result, in the case of measurement using a dosimeter, the cumulative dose increased with the increase of the fluoroscopic time, and the tendency was different according to the position of the operator. Simulation results show that the dose distribution of the eye lens in the mathematical phantom is about 1.1 ~ 1.3 times higher than that of the cornea. Also, The protective effect of the lead glasses showed a shielding effect of at least 3.7 ~ 21.4% in each eye.

Surgical Treatment of Superior Vena Cava Syndrome Caused by Hemodialysis Catheter - Report of 2 cases- (혈액 투석용 카테터에 의한 상대정맥증후군의 수술적 치료 -2예 보고-)

  • Cho Yang Hyun;Ryu Se Min;Kim Hyun Koo;Sim Jae Hoon;Kim Hark Jar;Choi Young Ho;Sohn Young-Sang
    • Journal of Chest Surgery
    • /
    • v.38 no.1 s.246
    • /
    • pp.67-71
    • /
    • 2005
  • The major etiology of superior vena cava (SVC) syndrome is malignancy. Radiologic endovascular intervention is the treatment of choice for patients with SVC syndrome due to malignant disease, which is unresponsive to radiation therapy and chemotherapy. However, it is not clear whether endovascular intervention can replace open surgery as the primary method of management of benign SVC syndrome. We report two cases of benign SVC syndrome resulting from dialysis catheters placed in the central veins. One patient underwent bypass surgery between innominate vein and right atrium by expanded polytetrafluoroethylene. Another patient had large thrombi in SVC and other central veins. We removed them under cardiopulmonary bypass to prevent pulmonary embolism, and SVC was repaired and augmented by autologous pericardium. Prompt symptomatic relief and angiographic improvements of collateral flow were achieved in both patients.

Musculoskeletal Ultrasound Intervention: Principles & Cautions (초음파를 이용한 침습적 치료: 원칙과 주의점)

  • Oh, Gun-Myung;Lee, Kyung Jae;Min, Byung-Woo;Kim, Dong-Wan
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.1
    • /
    • pp.38-44
    • /
    • 2013
  • The ultrasound can be used primarily to guide exact needle placement for aspirations of fluids, injections of steroid, and biopsies in musculoskeletal field. Recently, ultrasound-guided intervention is widely used because of several advantages such as real-time performance, relatively inexpensiveness, and getting multiple images without additional radiations. However, the modality is operator dependent and requires detailed knowledge of the relevant anatomy and there have been also reported serious complications related to the procedure. So, authors will discuss about the basic techniques, principles and cautions for the use of ultrasound-guided intervention in musculoskeletal field.

  • PDF

Considerations for Fluoroscopic Guided Intervention in Lumbar Spine (방사선 투시장치를 이용한 요추 중재술 시 고려점)

  • Kim, Dong-Hyun;Song, Kwang-Sup
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.3
    • /
    • pp.210-221
    • /
    • 2020
  • Spinal block procedures are useful methods that reduce the need for surgical treatment. In addition to their therapeutic aspects of pain relief, in many patients, they are also used for diagnostic purposes to distinguish from symptoms originating from extra-spinal areas. Therefore, these procedures are the most basic technique for orthopedic surgeons dealing with diseases from limbs and spine. On the other hand, despite the simplicity of the instruments and drugs used, the overall understanding of them and the lack of knowledge of the possible side effects and complications can cause serious harm to the patient at the beginning of the trial. Therefore, it is necessary to understand the types of drugs used in the spinal block procedures, pharmacokinetic properties, and the side effects of each drug. In addition, efforts should be made to identify their indications, as well as advantages and disadvantages of each procedure to avoid possible complications. The purpose of this review was to provide basic knowledge and skills necessary for lumbar spinal block procedures as well as provide the reader with the ability to perform themselves.

Reduction of Radiation Dose according to Geometric Parameters from Digital Coronary Angiography (디지털 심혈관조영장치의 기하학적 특성에 따른 선량 감소)

  • Kang, Yeonghan;Cho, PyongKon
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.4
    • /
    • pp.277-284
    • /
    • 2013
  • This study aims to find out geometric parameters which practitioner adjustable to reduce dose in coronary angiography. We take fluoroscopy and cine exposure by use of phantom, and got dose use the dose-area product(DAP) meter of angiography device, than convert DAP to effective dose. As results, Cine exposure shows higher dose measurement about 6-7 times than fluoroscopy. Dose in frame per second(FPS) mode could be decrease down to 70%, as lower FPS. In view of X-ray tube angle, LAO $45^{\circ}$+Caudal $30^{\circ}$ shows highest dose measurement. More use of Collimator, lower dose measurement. Source-image intensifier distance(SID) get longer to 10cm, dose of each fluoroscopy and cine exposure increase up to 25-30%. Image magnification of field of view(FOV) could increase dose up to 1.21-2 times. Also table-image intensifier distance get longer to 10cm, dose increased 1.11-1.25 times. Practitioner can adjust several geometric parameters, as FPS mode, tube angle, Collimation, SID, table-image intensifier distance, FOV. And each factors can reduce radiation dose in coronary angiography.

Radiation Dose and Estimate of Lifetime Attributable Risk of Cancer from Coronary Angiography and Percutaneous Coronary Intervention (관상동맥조영술과 경피적관상동맥중재술에서 환자 선량과 암 발생 생애귀속위험 평가)

  • Kang, Yeong-Han;Kim, Bu-Sun;Park, Jong-Sam
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.213-221
    • /
    • 2010
  • The Purpose of this study was to determine the effective dose to an average patient from Coronary Angiography (CA) and Percutaneous Coronary Intervention (PCI). And to estimate the lifetime attributable risk (LAR) of cancer associated with radiation exposure from CA and PCI. The dose-area product (DAP) values to the patient were recorded from 60 CA and 58 PCI. A Monte Carlo based program PCXMC was used to calculate the effective dose from DAP values for each patient. Lifetime attributable risks were estimated with models developed in the National Academies' Biological Effects of Ionizing Radiation VII report. The mean DAP values was $53.76\;Gy{\cdot}cm^2$ for CA and $165.82\;Gy{\cdot}cm^2$ for PCI. Mean effective dose were 1.28 mSv in CA, 3.94 mSv in PCI. Results of Calculate organ dose, lung doses was 2.17 mSv in CA and 6.71 mSv in PCI. Female breast doses was 5.45 mSv in CA and 16.82 mSv in PCI. LAR estimates for CA varied from 1 in 1,508 for man to 1 in 1,357 for women. In PCI procedure varied from 1 in 553 for man to 1 in 482 for women. DAP can be used as the dose indicator to calculate the organ dose and effective dose of patient based on Monte Carlo simulation. These dose estimates derived from our simulation models suggest that CA and PCI are associated with a nonnegligible LAR of cancer. This risk varies markedly and is considerably greater for women, PCI than for man, CA.