일반엑스선영상검사의 인자에 따른 산란방사선량 평가 및 분석 (Evaluation and Analysis of Scattered Radiation Dose according to Factors in General X-ray Examination)

  • 정동경;박명환;서정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권1호
    • /
    • pp.13-19
    • /
    • 2024
  • Control of scattered radiation is one of very important factors in the use of medical radiation. In general X-ray exam, the causes, measurement methods, and the kind of detectors of scattered rays within the radiation area are diverse. In this study, the dose of scattered ray was measured by changing the thickness of the polycarbonate phantom and the tube voltage. As a result of measurement of scattered radiation, the results show that the scattered dose significantly(p<.05) increased with growing of thickness of phantom in the tube voltage 40, 50 and 60 kVp(F(p)<.05, R2>64%). As tube voltage increased at all phantom thicknesses, the scattered dose also significantly(p<.05) increased(F(p)<.05, R2>69%). In cases where a significant correlation was shown, the coefficient of determination of more than 60% was shown in regression analysis. The results of this study can be used as data on scattered radiation dose according to the tube voltage and the object thickness in general X-ray imaging exam.

방사선 종양학과 방사선사의 조직문화가 조직 유효성에 미치는 영향 (The effects of organizational culture on organizational effectiveness in radiation therapy technologist)

  • 심재구;정홍량
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2012년도 춘계 종합학술대회 논문집
    • /
    • pp.183-184
    • /
    • 2012
  • 방사선 종양학과에 근무하는 방사선사는 암 환자 치료를 위해 의학의 전문적인 지식 습득, 고도로 향상된 의료 기술 그리고 방사선 치료 시 환자 응대에 대한 부담감으로 전문직인으로서 많은 스트레스를 받게 된다. 이에 본 연구는 서울, 경기에 근무하는 방사선 종양학과 방사선사를 대상으로 배경 변인에 따라 조직 효과성과 직무 스트레스를 파악하고,부서안에서 파트별 직무 분석을 통해 감정 노동에 대해 어느 정도 영향을 미치는지 알아보고 향 후 방사선 종양학과 방사선사의 직무에 따라 조직 문화를 관리할 수 있는 기초 자료를 제공하여 직무 스트레스가 조직 유효성에 미치는 영향의 정도를 규명함으로써 효율적인 인력 관리 및 조직 관리 방안을 모색하기 위함이다.

  • PDF

고 에너지 방사선치료 시 GEANT4-DICOM과 TPS간 선량비교 연구 (A Comparative Study on the Dose of GEANT4-DICOM to TPS for High-Energy Radiation Treatment)

  • 곽근탁;김양수;권형철;김정수;이선영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.567-572
    • /
    • 2018
  • Radiation therapy is one of the beneficial choices in the treatment of cancer. This is a comparison of TPS(Treatment Planning System) and GEANT4-DICOM, which should be preceded by the best radiation therapy. A treatment plan for prostate cancer was established with Eclipse and the point doses 366.1 cGy, 189.1 cGy, 213.4 cGy, 127 cGy, 105.7 cGy of any five prostate, bladder, rectum, right femoral head and left femoral head were identified. GEANT4-DICOM simulation showed that the results of Eclipse and ${\pm}2%$ dose error were confirmed. The monthly X-ray output agreement management value recommended by TG-142 is ${\pm}2%$, which means that the experimental results can be meaningful. In conclusion, GEANT4-DICOM is an infinite way to obtain more extended dose information once the time constraints are overcome in the simulation.

척추 방사선수술 시 다엽콜리메이터 위치 오차의 임상적 위험성 평가 (Evaluation of Clinical Risk according to Multi-Leaf Collimator Positioning Error in Spinal Radiosurgery)

  • 강동진;오건;신영주;강진규;정재용;이보람
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권6호
    • /
    • pp.527-533
    • /
    • 2023
  • The purpose of this study is to evaluate the clinical risk of spinal radiosurgery by calculating the dose difference due to dose calculation algorithm and multi-leaf collimator positioning error. The images acquired by the CT simulator were recalculated by correcting the multi-leaf collimator position in the dose verification program created using MATLAB and applying stoichiometric calibration and Monte Carlo algorithm. With multi-leaf collimator positioning error, the clinical target volume (CTV) showed a dose difference of up to 13% in the dose delivered to the 95% volume, while the gross tumor volume (GTV) showed a dose difference of 9%. The average dose delivered to the total volume showed dose variation from -8.9% to 9% and -10.1% to 10.2% for GTV and CTV, respectively. The maximum dose delivered to the total volume of the spinal cord showed a dose difference from -14.2% to 19.6%, and the dose delivered to the 0.35 ㎤ volume showed a dose difference from -15.5% to 19.4%. In future research, automating the linkage between treatment planning systems and dose verification programs would be useful for spinal radiosurgery.

계획된 행위이론을 적용한 방사선학과 대학생들의 방사선 방어용 보호장구 착용에 대한 분석 (Analysis of Radiology Students' Behavior in Wearing Radiation Protection Equipment - based on the Theory of Planned Behavior)

  • 노지숙;이병훈;배상열;박형수;류소연;박종
    • 한국콘텐츠학회논문지
    • /
    • 제11권9호
    • /
    • pp.443-452
    • /
    • 2011
  • 본 연구는 의료기관에서의 임상실습을 마친 방사선학과 대학생들을 대상으로 방사선 방어용 보호 장구 착용행위에 어떠한 영향을 미치는지에 대하여 알아보고자 연구되었다. 계획된 행동이론에서 제시하는 '태도' '주관적 규범' '지각된 행위통제' 및 '의도'를 연구 틀에 적용하여 보호 장구 착용행위와 관련된 요인을 측정하였다. 대상자는 광주, 전남지역의 방사선학과가 있는 대학의 방사선학과 대학생 중, 임상실습을 마친 총230명에게 자기기입식 설문조사를 실시하여 192부를 최종 대상으로 하였다. 로지스틱 회귀분석을 통하여 분석한 결과 보호 장구 착용은 학년(비차비: 11.60, 95%신뢰구간: 2.473-54.415)이 낮을수록, 실습병원의 규모(비차비: 2.80, 95% 신뢰구간: 1.337-5.886)가 작을수록, 태도 점수(비차비: 0.957, 95%신뢰구간: 0.933-0.98)가 낮을수록, 지각된 행위통제의 점수(비차비: 1.063, 95%신뢰구간:1.02-1.10)가 높을수록 통계적으로 유의하였다. 이상의 결과를 통해 계획된 행동이론과 관련하여 방사선학과 대학생들의 임상실습에서 방사선 방어용 보호 장구의 착용률을 높이기 위해서는 태도와 지각된 행위 통제와 같은 요인들을 고려한 교육 프로그램의 개발이 필요할 것으로 생각된다.

일부지역 방사선(학)과 학생들의 학과만족도 및 진로인식 (Department satisfaction and Course awareness of Radiological science student in some regions)

  • 배석환;이희주;이재영;김용권;이무식;홍지영
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2011년도 춘계학술논문집 2부
    • /
    • pp.667-670
    • /
    • 2011
  • 본 연구는 일부지역 방사선(학)과 학생들을 대상으로 학과만족도 및 진로인식을 성별, 연령, 학년, 출신고교, 병역관계, 교육과정에 따른 차이를 분석하고자, 3년제 대학 방사선과 4곳과 4년제 대학교 방사선학과 3곳의 학생424명을 대상으로 하였으며, 결과는 다음과 같다. 방사선(학)과 학생들의 학년별 학과만족도는 1, 4학년이 다소 높았고 입학동기에 따른 학과 만족도는 본인의 관심, 적성으로 입학했을 시 만족도가 가장 높았다. 교과 만족도는 남자가 여자보다 높았으며 병역 미필이 군필보다 높은 것으로 나타났다. 진로선택 및 취업준비과정에 필요한 정보획득 경로로는 교수를 통해서가 가장 많았으며 선배, 친구가 그 뒤를 이었고, 취업을 위해 가장 중요하다고 생각하는 것으로서 외국어가 1순위였고 학점, 국가고시 성적이 그 뒤를 이었다. 교육과정에 따라 취업을 위해 가장 중요하다고 생각하는 사항에 대한 결과로는 외국어는 3년제, 4년제 순으로 인간관계는 4년제, 3년제 순 이었으며, 취업을 위해 가장 많은 시간을 할애하고 있는 것은 성적관리가 가장 많았고 어학, 자격증이 그 뒤를 이었다. 방사선(학)과 학생들의 희망 진로(취업)방향에 대한 결과로는 의료기관이 가장 많았으며 보건직 공무원이 그뒤를 이었다. 취업 시 고려사항으로는 적성이 가장 높았으며 급여, 안정성이 그 뒤를 이었다. 결론적으로 방사선(학)과 학생들의 학과만족도 및 진로인식은 성별, 연령, 학년, 출신고교, 병역관계, 교육과정에 따라 다소 차이가 있는 것으로 나타났다.

  • PDF

이동형 방사선검사에서 영상의 왜곡과 선량에 관한 연구 (A Study on Distortion and Dose of Images in Mobile Radiography)

  • 송현석;임청환;정홍량;김종성;김영란;정성훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권4호
    • /
    • pp.305-312
    • /
    • 2022
  • The proportion and testing of portable radiation tests, which are limited at the request of the doctor, are gradually increasing only for patients in emergency situations and difficulties in moving. However, as there are many limiting factors compared to fixed devices, this study intends to measure and analyze the distortion of images according to the angle of the detector and the change in dose according to the position of the subject. For distortion experiments using a mobile radiation generator used in Hospital A, the SID was tilted by 110 cm, 14"×17" wireless FPD detector to 0°, -5°, -10°, -15°, -20°, and -35° to measure the change in area. The dose according to the location of the detector was analyzed on average by measuring the central dose at 110 cm of the SID and measuring the dose of 9 locations three times each. The analysis result of distortion by location according to the angle of the detector showed a statistically significant difference (f=58.74, p<0.000). Therefore, it can be seen that the angle of the detector and the tube is closely related to the distortion of the image. The difference in dose by location of the detector increased with respect to the center - pole, and decreased with the + pole. Tests using mobile radiation generators will require careful efforts by clinicians to position patients in the center of the detector for accurate diagnosis, and efforts will be made to level the angle between the mobile radiation generators and the detector.

방사선사면허 시험 대비 모의고사 중심으로 대면 교육과 비대면 교육비교 분석 (A Comparative Analysis of Face-to-face and Non-face-to-face Education Based on the Mock Test for a Radiologist)

  • 김용완;안병주;이준행;김주미;여화연
    • 한국방사선학회논문지
    • /
    • 제14권7호
    • /
    • pp.923-930
    • /
    • 2020
  • 2020년도는 COVID-19 위기 상황으로 인하여 불가피하게 전면 비대면 교육을 시행하게 되었다. 연구자는 방사선사면허대비 전국 보건 계열 방사선과 3학년, 방사선학과 4학년 학생들이 면허시험을 앞두고 실시한 대면 교육과 비대면 모의시험(2019년 1.2회, 2020년 1.2회)의 성적을 알아보기 위하여 전국 방사선학과 및 방사선과 48개 대학 중 5개의 대학을 선정하여 대면 교육과 비대면 교육(2019년 1,2회, 2020년 1,2회)의 성적을 1회 모의고사 시험에 대면 교육과 비대면 교육(2019년 1회, 2020년 1회)의 성적을 비교하여, 비모수 검정으로 통계를 분석한 결과, 이론(Z=-2.023, p<0.05), 응용(Z=-2.023, p<0.05), 실기(Z=-2.023, p<0.05) 모두 성적에 차이가 있는 것으로 나타났다. 2회 모의고사 시험에 대면 교육과 비대면 교육 (2019년 2회, 2020년 2회)의 성적을 비교하여, 비모수 검정으로 통계를 분석한 결과, 이론(Z=-2.023, p<0.05), 응용(Z=-2.023, p<0.05), 실기(Z=-1.753, p<0.05) 성적에 차이가 있는 것으로 나타났다. 모의고사 시험의 결과 비대면 교육이 대면교육에 비교해 성적이 저조함에 따라 강의 방법을 달리하거나, 학생들과 소통할 수 있는 다양한 교육 방법을 병행해야 할 것으로 사료된다.

방사선학과 대학생의 스마트폰 과의존이 대학교 생활적응에 미치는 영향 분석 (An Analysis on the Influence of Smartphone Addiction by University Students of Radiological Science on School Life)

  • 정홍량;황율흔;최지훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권5호
    • /
    • pp.387-392
    • /
    • 2019
  • This study analyzed the influence of smartphone addiction on adaptation to school life by using the questionnaire survey method of 431 students of radiological science in six regions. The results showed that 89.6% of students are the general user group, 6.3% the high risk group and 4.2% the potential risk group. Adaptability to school life was found to be social adaptability 3.71, righteous adaptability 3.17 and academic adaptability 2.95. Academic adaptability was 3.06 for male students and 2.79 for female students. And righteous adaptability was 3.26 for male students and 3.03 for female students. As a result, male students were more adaptable than female students in academic adaptability and righteous adaptability, which was statistically significant. And Social adaptability was 3.73 for female students and 3.68 for male students, but there was no significant difference(p<.001). Adaptability to school life by smartphone addiction level was found to be the general user group 3.19, the potential risk group 3.05 and the high risk group 2.81. The difference of righteous adaptability between the general user group and the high risk group was statistically significant. And social and academic adaptability of the general user group and the high risk group was no significant(p<.01).

Telometer를 이용한 슬관절 측부인대 Stress-radiogram의 재현성 비교평가 (Comparative Evaluation of Reproducibility of Knee Joint Collateral Ligament Stress-radiogram Using Telometer)

  • 정진만;정성빈;김상현;이정훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.539-543
    • /
    • 2018
  • Telometer is a supplementary filming device that improves the image quality and minimizes the motion unsharpness by enhancing the reproducibility of diagnostic images because it applies constant pressure (force) to the affected area. The stress-radiogram which is widely used to provide the o-bjective quantitative stability of knee ligament is reported in literature as the most suitable method to evaluate the stability of ligament and it is advised to use the Telometer. In order to evaluate the image reproducibility of the Telometer, the collateral ligament which is the most vulnerable among the ligaments consisting of the knee joint, the stress-radiogram was executed in the order of the Telometer, the push pull gauge and the conventional stress radiogram. Then, SPSS (Statistical Package for the Social Science) for Windows 22.0 was used for comparison and evaluation. According to the results of comparison and evaluation, the standard errors and standard deviations became smaller in the order of the Telometer, the push pull gauge, the conventional stress radiogram while the image reproducibility was higher in the order of the Telometer, the push pull gauge, the conventional stress radiogram. Therefore, it is considered that the use of the TELOS for stress-radiogram would enhance the quality of patient diagnostic images and the work performance of radiologists.