• Title/Summary/Keyword: 방사선노출

Search Result 455, Processing Time 0.023 seconds

Absorbed and effective dose for periapical radiography using portable and wall type dental X-ray machines (이동형 구내방사선촬영기와 벽걸이 구내방사선촬영기로 촬영한 치근단 방사선촬영에서 환자의 흡수선량과 유효선량 평가)

  • Han, Won-Jeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.184-190
    • /
    • 2012
  • Purpose: The purpose of this study was to measure the absorbed dose and to calculate the effective dose for one periapical radiography using the portable and wall type dental X-ray machines. Materials and methods: Thermoluminescent chips were placed at 25 sites throughout the layers of the head and neck of a tissue-equivalent human skull phantom. The man phantom was exposed with the portable and wall type dental X-ray machines. For one periapical radiography taken by portable dental X-ray machine, the exposure setting was 60 kVp, 2 mA and 0.2 seconds, while for one periapical radiography taken by wall type dental X-ray machine, exposure setting was 70 kVp, 8 mA and 0.074 seconds. Absorbed dose measurements were performed and equivalent doses to individual organs were summed using ICRP 103 to calculate effective dose. Results: In the upper anterior periapical radiography using portable dental X-ray machine and in the lower posterior periapical radiography using both machines, the highest absorbed dose was recorded at the mandible body. The effective dose in upper anterior periapical radiography using portable and wall type dental X-ray machines was $4{\mu}Sv$, $2{\mu}Sv$, respectively. In the lower posterior periapical radiography, the effective dose for each portable and wall type dental X-ray machines was $6{\mu}Sv$, $2{\mu}Sv$. Conclusion: It was recommended that the operator use prudently potable dental X-ray machine because that the effective dose in the periapical radiography using wall type dental X-ray machine was lower than that in the periapical radiography using portable dental X-ray machine.

Study on the Radiation Dose about Skin Thickness of Rat (For Radiation Damage Tissue Engineering) (쥐의 피부두께에 따른 선량연구)

  • Jung, Hongmoon;Won, Doyeon;Kim, Hyeongyun;Jung, Jaeeun;Choi, hyeun-woo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.375-379
    • /
    • 2016
  • A rat is the most common experimental animal used for the realization of the radiation injury model. The certain thickness of rat skin was prepared by peeling off a rat skin. Radiation level was measured by using this rat skin. Also, The schematic of the formula was made that can predict the radiation absorbed dose (RAD) as a function of the thickness of the rat skin. Consequently, we will provide the RAD information in the realization of in-vitro experimental model regarding the rat's skin thickness by applying the formulas. Moreover, the results from this study can be effectively used for the in-vitro experiment of the rat subcutaneous tissue which was exposed to radiation.

A Study on Reduction of Radiation Exposure by Nuclear Medicine Radiation Workers (핵의학 방사선 작업종사자 피폭 감소 방안에 대한 연구)

  • Lee, Wanghui;Ahn, Sungmin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.271-281
    • /
    • 2019
  • This study investigated the shielding efficiency of various types of shielding materials and measured the dose by organ using the phantom. Results of Shielding Efficiency Measurement Using Personal Radiation Meter. Among the various shielding materials, 1.1 mm RNS-TX composed of nano tungsten showed the highest shielding efficiency and 0.2 mm lead shielding showed the lowest shielding efficiency. 99mTc 30 mCi was exposed to the phantom for 120 minutes and the result of the measurement of the organs. 20.53 mSv without radiation protective clothing, 8.75 mSv when wearing 0.25 mm Pb protective clothing, 6.03 mSv when wearing 0.5 mm Pb protective clothing. 131I 2 mCi mCi was exposed to the phantom for 120 minutes and the result of the measurement of the organs. 7.71 mSv without radiation protective clothing, 4.88 mSv when wearing 0.25 mm Pb protective clothing, 2.79 mSv when wearing 0.5 mm Pb protective clothing. 18F 5 mCi was exposed to the phantom for 120 minutes and the result of the measurement of the organs. 16.39 mSv without radiation protective clothing, 15.84 mSv when wearing 0.25 mm Pb protective clothing, 12.52 mSv when wearing 0.5 mm Pb protective clothing. None of the radiation workers working in the nuclear medicine department exceeded the dose limit. However, when compared with other workers in the hospital, they showed a relatively high dose. Therefore, it is necessary to prepare measures to reduce and manage the dose of radiation workers in the nuclear medicine department through the wearing of radiation protective clothing made of lightweight, shielding material with good shielding efficiency, circulation task, task sharing, and substitution equipment such as auto dispenser.

Measuring Absorbed Dose from Medical X-ray Equipment Using Optically Stimulated Luminescence Dots (광자극선량계의 저에너지 엑스선 특성비교)

  • Jung, Sook Jin;Jin, Gye Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.79-83
    • /
    • 2018
  • In this paper, we measured and analyzed the dose correction factor, absorbed dose linearity, peak voltage X-ray response, angular dependence. Exposure dose correction factor, absorbed dose linearity, and peak voltage linearity using the medical X-ray generator were all in accordance with IEC-62387-1 (2007). The reference to the dosimetry direction at 0, 30, and 60 degrees relative to baseline radiation exposure was -29% (${\pm}30^{\circ}$) and + 67% (${\pm}60^{\circ}$). The values measured at $30^{\circ}$ were -8% lower than the standard and -18% lower than the standard at $60^{\circ}$. Therefore, the effect of direction should be corrected when using OSL dot dosimeter.

A Study on the Optimization of Image Quality and Dose in Chest PA Digital Radiography (디지털 흉부 방사선 검사의 화질과 선량의 최적화에 관한 연구)

  • Park, Han Sol;Kim, Myeong Seong;Jung, Hong-Moon;Lee, Jong Woong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.55-61
    • /
    • 2017
  • There are no recommended test conditions for digital photography in Chest PA examinations. However, each company recommends shooting examinations of the high voltage applied to the previous analog examination. The condition that satisfies the value of 200 ~ 800 which is the recommended Exposure Index value recommended by Philips was selected, and the dose was evaluated by Monte Carlo simulation, and the SNR and CNR were compared. As a result, it was possible to reduce the effective dose up to 77% by controlling the tube voltage, tube current, and additional filter, not the conventional high voltage imaging method. Although there were some differences according to the test conditions, the image evaluation results were similar to the images. We will compare the exposure dose according to changes in tube voltage, tube current, and additional filter at the digital chest radiograph and evaluate the image quality of the image to propose optimal conditions.

Calculation of Effective Dose on Domestic Chest PA X-ray Examinations (국내 흉부 X-선 검사에 따른 유효선량 계산)

  • Choi, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.827-832
    • /
    • 2018
  • Research on effective dose analysis of actual conditions of use based on large data is scarce. In this study, the exposure conditions of Chest X-Ray examinations used by 324 medical institutions in Korea were calculated and evaluated using computer simulations. As a result of the experiment, the effective dose in the low energy parameter bands was 0.024 mSv, followed by spleen, adrenal glands, and lung. The effective dose in the high-energy exposure parameter band was 0.123 mSv, followed by height, spleen and adrenal glands. The effective dose was 0.017 mSv when the optimal conditions considered the quality and exposure proposed in Park's study were used. The results of the study will be a reference for chest X-rays and will help reduce patient exposure.

Analysis and Evaluation of Computed Tomography Dose Index (CTDI) of Pediatric Brain by Hospital Size (병원규모별 소아 두부 CT 검사 선량지표 분석 평가)

  • Kim, Hyeonjin;Lee, Hyoyeong;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.503-510
    • /
    • 2016
  • Even though children are exposed to the same amount of radiation, their effective dose amount is higher than those of adults. Therefore, it is very important to reduce the amount of unnecessary radiation exposure because children have a higher radiosensitivity and a smaller body size than adults. In this study, the proposal to seek ways to reduce the amount of radiation is drawn by comparing and analyzing CT Dose Index(CTDI) on the pediatric head CT which was performed at the Busan regional hospitals, to the national diagnostic reference levels. For this, the pediatric head CT scan was conducted among the CT equipments that were installed in downtown Busan. From 2,043 children 10 years old or less who were referred to the pediatric head CT scan, targeting the 28 CT equipments in the 24 hospitals that transmit dose reports to PACS, were examined retrospectively. As a result, the average value of CTDIvol, computed tomography dose index (CTDI) of infant brain, across the hospital, was 31.18 mGy, with DLP of $444.73mGy{\cdot}cm$, which exceeded the diagnostic reference level. The lower the age, the more management is needed for radiation. However, the reality is that the CT examinations are being conducted with a dose that exceeds the reference level as the age of the aged is exceeded. For this purpose, the study seeks to determine the degree of doses of doses outside the diagnostic reference level and analyze the cause of the excess dose and devise measures to reduce the dose reduction.

An Optimal Structure of a Novel Flat Panel Detector to Reduce Scatter Radiation for Clinical Usage: Performance Evaluation with Various Angle of Incident X-ray (산란선 제거를 위한 신개념 간접 평판형 검출기의 임상적용을 위한 최적 구조 : 입사 X선 각도에 따른 성능평가)

  • Yoon, Yongsu
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.533-542
    • /
    • 2017
  • In diagnostic radiology, the imaging system has been changed from film/screen to digital system. However, the method for removing scatter radiation such as anti-scatter grid has not kept pace with this change. Therefore, authors have devised the indirect flat panel detector (FPD) system with net-like lead in substrate layer which can remove the scattered radiation. In clinical context, there are many radiographic examinations with angulated incident X-ray. However, our proposed FPD has net-like lead foil so the vertical lead foil to the angulate incident X-ray would have bad effect on its performance. In this study, we identified the effect of vertical/horizontal lead foil component on the novel system's performance and improved the structure of novel system for clinical usage with angulated incident X-ray. Grid exposure factor and image contrast were calculated to investigate various structure of novel system using Monte Carlo simulation software when the incident X-ray was tilted ($0^{\circ}$, $15^{\circ}$, and $30^{\circ}$ from the detector plane). More photons were needed to obtain same image quality in the novel system with vertical lead foil only then the system with horizontal lead foil only. An optimal structure of novel system having different heights of its vertical and horizontal lead foil component showed improved performance compared with the novel system in a previous study. Therefore, the novel system will be useful in a clinical context with the angulated incident X-ray if the height and direction of lead foil in the substrate layer are optimized as the condition of conventional radiography.

Current status of dental intraoral imaging devices and radiographic safety management (치과 구내촬영 장비 현황과 방사선 안전 관리 실태 연구)

  • Kang, Eun-Ju;Hyeong, Ju-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.16 no.2
    • /
    • pp.205-214
    • /
    • 2016
  • Objectives: The purpose of the study is to investigate the current status and radiographic safety management in Korea. Methods: A self-reported questionnaire was completed by 200 dental hygienists in Jeonbuk province from September 1, 2014 and October 31, 2014. The questionnaire consisted of general characteristics of the subjects, radiation knowledge, radiation safety management, and radiation exposure anxiety. Data were analyzed using SPSS 18.0 program. Results: Duration of clinical experience(r=0.142) and number of daily radiation shot(r=0.145) showed a positive correlation to radiation safety management, and a nrgative correlation to use of intraoral films and digital devices(r=-0.587). A logistic regression analysis was performed in order to evaluate the influence on radiography knowledge. The results showed that the factors had significant influences on the age group over 41 years old(OR 7.25; 95% CI 1.30-40.43) and those who took a position above team leader(OR 0.23; 95% CI 0.59-0.90). Conclusions: It is very important to have the safety management toward dental intraoral imaging and radiograpgic shot in the dental hygienists. Continuous efforts should be emphasized on radiographic safety management and behavior.

Radiation Effects of Fiber Bragg Gratings on the High Temperature Annealing Condition (광섬유 브래그 격자의 고온 어닐링 조건에 따른 방사선 영향)

  • Kim, Jong-Yeol;Lee, Nam-Ho;Jung, Hyun-Kyu;Im, Don-Sun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.785-787
    • /
    • 2016
  • In this study, we studied the gamma-radiation effect of fiber Bragg gratings on the high temperature annealing condition. The fiber Bragg gratings were exposed to gamma-radiation up to a dose of 30.8 kGy at the dose rate of 115 Gy/min. According to the experimental data and analysis results, the gratings that were stabilized at different temperatures have clearly shown that exposure to higher temperatures increases their radiation sensitivity.

  • PDF