• Title/Summary/Keyword: 발열성능

Search Result 328, Processing Time 0.024 seconds

Effects of CNG Heating Value on Combustion Characteristics of a Diesel-CNG Dual-Fuel Engine (디젤-CNG 혼소엔진에서 CNG 발열량 변화가 연소 특성에 미치는 영향)

  • Kim, Yongrae;Jang, Hyeongjun;Lee, Janghee;Kim, Changgi
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.6
    • /
    • pp.28-33
    • /
    • 2015
  • In this study, a dual fuel engine fueled with natural gas and diesel was tested to investigate the effects of heating value variation of CNG fuel. CNG substitution rate which is defined as the ratio of CNG and diesel supplied in a heating value basis was fixed at 80%. The higher heating value was varied from $10,400kcal/Nm^3$ to $9,400kcal/Nm^3$ by mixing nitrogen gas with pure CNG and diesel fuel was injected at a fixed injection timing. The engine test results showed that thermal efficiency and power output were decreased as the heating value of mixed CNG fuel was decreased. And the peak cylinder pressure was also decreased but the ignition delay time and the combustion duration and timing were almost same.

A Study on the Evaluation Method of Lap Shear Strength for Induction Welding of Thermoplastic Composites using Tensile Test (인장 시험을 이용한 열가소성 복합재료 유도용접 전단강도 평가방법에 대한 고찰)

  • Baek, Inseok;Lee, Seoksoon
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.1
    • /
    • pp.12-16
    • /
    • 2022
  • Currently, Induction welding is attracting attention as a non-contact, clean and fast welding process. However, since thermoplastic resins are not affected by electromagnetic fields, induction welding requires a heating element called a susceptor. Researches are being conducted with the aim of achieving high-quality bonding, however, the factor of a heating element is an issue, hence the need to set a standard. Specimen fabrication and testing are conducted according to ASTM D5868. In this study, we propose that the evaluation criteria be judged on the basis of three factors; the condition of the welded joint surface, void content, and lap shear strength. Since the adhesive surface to be welded melts and solidifies as it cools, rapid temperature changes can generate pores. In addition, if the heating is not uniform, it is difficult to expect the desire performance. Using PA6 (CF 30%) thermoplastic, susceptor fabrication, induction welding and performance verification were conducted.

A Study on Total Fire Risk Assessment of Wallpapers (벽지의 종합적 화재 위험성 평가에 관한 연구)

  • 박미라;김광일;김태구
    • Fire Science and Engineering
    • /
    • v.17 no.1
    • /
    • pp.33-39
    • /
    • 2003
  • The purpose of this study is to evaluate flame retardant performance, thermal stability and toxicity of combustion gases for some commercial wallpapers. ID evaluate flame retardant performance 45 degree combustion experiment method was used and thermal stability was evaluated using DSC and TGA apparatus (OSC-50/Shimadzu, TGA2050/TA Instruments Inc) . Concentrations of CO, $CO_2$, HCN and HCI were measured with (GASTEC/Japan, MSA400 Gas Monitor/Infitron Inc) and toxicity indices using NIST N-Gas Model were applied to evaluate the toxicity of combustion gases. The evaluation produced the following results : First, paper cork and PVC wallpaper treated with flame retardants were found to be suitable for flame retardant performance standards. Second, paper, cork and PVC wallpaper non-treated with flame retardants were shown to be relatively more hazardous because they had greater calorific values and a faster decomposition time than the flame retardant treated wallpapers. Third, the toxicity indices of non-treated wallpapers were found to be higher than those of treated wallpapers, and the toxicity index of PVC wallpapers was higher than those of paper and cork wallpapers.

A Study on Operating Characteristics and Development of Woven-Wired Wick Heat Pipe (편조 윅 히트파이프의 개발과 작동특성에 관한 연구)

  • Moon, Seok-Hwan;Choi, Choon-Gi;Hwang, Gunn;Choy, Tae-Goo
    • Journal of Energy Engineering
    • /
    • v.9 no.1
    • /
    • pp.54-59
    • /
    • 2000
  • 전자부품 및 시스템의 고속/고밀도화 추세에 따라 발열밀도가 계속증가하고 있다. 최근 팬티엄 II 급이상의 노트북 컴퓨터의 CPU에서는 칩당 발열량이 10W 이상으로 증가하고 있고 패키징 공간의 제한 때문에 소형히트파이프를 이용한 냉각이 많이 적용되고 있다. 본 연구에서는 모세압구동력이 크고 생산성등이 고려된 편조 형태의 새로운 윅을 개발하였으며 , 노트북 컴퓨터의 CPU 등 소형 전자부품냉ㄱ가에 적용가능한 직경 3, 4 mm 히트파이프를 설계 및 제작하였다. 직경 3, 4 mm Miniature Heat Pipe (이하 MHP) 의 작동특성은 일반적인 중형히트파이프와 다르므로 MHP 의 열전달 특성 및 작동성능에 미치는 각종 인자들의 영향을 파악하고자 성능시험을 수행하였다. 고려된 작동인자로는 작동유체 충전률, 전체 파이프길이 및 증발부, 응축부길이, 설치 경사각, 윅의 가닥수, 열부하 등이다. 작동인자의 영향과 관련된 연구결과는 향후 패키징을 위한 응용연구의 기초자료로 활용할 수 있을 것이다.

  • PDF

Effect of Flame Retardants on Flame Retardancy of Rigid Polyurethane Foam (난연제 종류에 따른 경질 폴리우레탄 폼의 난연 특성)

  • Kim, Keunyoung;Seo, Wonjin;Lee, Ju-Chan;Seo, Jung-Seok;Kim, Sangbum
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.5
    • /
    • pp.75-80
    • /
    • 2013
  • In this study, the effect of phosphorus flame retardants on the flame retardancy of the rigid polyurethane foam(PUF) was studied. Tetramethylene bis(orthophos-phorylurea)[TBPU] and Tris(2-chloroethyl) phosphate[TCEP], Tris(2-chloropropyl)phosphate [TCPP], Triethyl phosphate[TEP] were used as flame retardant. It was found that TBPU added PUF exhibits low mean heat release rate(HRR), peak HRR, effective heat of combusion(EHC), mass loss rate (MLR), CO yield and $CO_2$ compared other flame retardants.

Performance Analysis of Heating Nonslip using Solar Power Energy (태양광 에너지를 이용한 발열논슬립의 성능분석)

  • Moon, Jong Wook;Choe, Jae Won;Yun, Seok Heon
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.6
    • /
    • pp.55-61
    • /
    • 2018
  • This study aims to analyze the performance of Heated-nonslip using renewable energy to prevent nonslip freezing during winter. For this purpose, power generation system and congratulatory devices using solar energy are designed, and it is designed to provide regular electricity to heat up nonslip through Electrical storage system(ESS). In this study, It is intended to analyze the level of electrical energy suitable for nonslip using 24V or 48V, and to measure the temperature changes and temperature distribution according to the location of the test object. As a result of the experiment, nonslip's frame temperature was measured at $-7.5{\sim}-5^{\circ}C$ on average, and $-1{\sim}-2^{\circ}C$ on the heating cable during the supply of 24V and this could not be the solution for defrosting freezing nonslip in the winter. As a result of heating nonslip by supplying 48V with an electrical power of 8W, the temperature of the nonslip was shown to be between $5^{\circ}C$ and $11^{\circ}C$ to $13^{\circ}C$. Even if the power supply was switched on and off every minute, the temperature did not drop below $4^{\circ}C$ and the frozen ice melted on the nonslip without freezing.

Numerical Analysis of Thermal Environment Control in High-Density Data Center (고밀도 데이터센터의 열환경제어를 위한 수치해석)

  • Kwon, Oh-Kyung;Kim, Hyeon-Joong;Cha, Dong-An
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.8
    • /
    • pp.821-828
    • /
    • 2012
  • Increasing heat generation in CPUs can hamper effective recirculation and by-pass because of the large temperature difference between the exhaust and the intake air through a server room. This increases the overall temperature inside a data center and decreases the efficiency of the data center's cooling system. The purpose of the data center's cooling system is to separate the intake and exhaust air by controlling the computer room air-conditioner(CRAC). In this study, ICEPAK is used to conduct a numerical analysis of a data center's cooling system. The temperature distribution and the entire room are analyzed for different volumetric flow rates. The optimized volumetric flow rate is found for each CPU power. The heat removal and temperature distribution for CPU powers of 100, 120, and 140 W are found to be the best for a volumetric flow rate of $0.15m^3/s$. The numerical analysis is verified through RTI indicators, and the results appear to be the most reliable when the RTI value is 81.

Analytical Estimation of the Performance of Marine Concrete with Mineral Admixture (광물질 혼화재를 혼합한 해양 콘크리트의 해석적 성능 평가)

  • Lee, Bang-Yeon;Kwon, Seung-Jun;Kang, Su-Tae
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.3 no.4
    • /
    • pp.301-306
    • /
    • 2015
  • For the purpose of developing high performance marine concrete with improved crack resistance and durability, this analytical study aimed to estimate strength, hydration heat characteristics, and chloride attack resistance of concrete with mineral admixture. Ground granulated furnace slag and fly ash were considered for mineral admixture. The replacement of ground granulated furnace slag and fly ash considered in the analysis was in the range of 0~70% and 0~40 %, respectively. The analysis results indicated that both ground granulated furnace slag and fly ash decreased compressive strength, and the effect of adding ground granulated furnace slag on mitigation of hydration heat was limited whereas fly ash had an noticeable influence on it. It was also found that the replacement with ground granulated furnace slag enhanced the chloride attack resistance but fly ash deteriorated the resistance. From the analytical studies, It could be expected that a ternary blended cement composition with proper amount of ground granulated furnace slag and fly ash might be effective to control crack resistance as well as chloride attack resistance of marine concrete.

Design of PI Controller for Heated-Glass Temperature Control System (4 [kW]급 발열유리 온도제어 시스템의 PI제어기 설계)

  • Lee, S.H;Lee, C.Y;Kim, J.Y;Kim, I.D;Nho, E.C;Choi, C.h
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.155-156
    • /
    • 2011
  • 겨울철 또는 온도가 낮은 지역에서는 선박과 건축용 등의 창유리에 결로, 결빙현상이 쉽게 발생하여 시야확보가 어렵다. 이 현상들은 창유리의 온도를 상승시킴으로써 방지가 가능하다. 하지만 창유리의 온도는 바람과 기온 및 기후 변화 등의 외란에 민감하므로 일정한 온도 유지가 어렵다. 따라서 민감한 창유리의 온도를 일정하게 유지하기 위한 제어기법이 필요하다. 본 연구에서는 산업현장에 많이 사용되고 있는 PI 제어 기법을 적용하여 4 [kW]급 발열유리 온도 제어 시스템의 제어기를 설계하고 실험을 통하여 제어기의 성능을 검증하였다.

  • PDF