• Title/Summary/Keyword: 발생능력

Search Result 3,275, Processing Time 0.041 seconds

The difference of image quality using other radioactive isotope in uniformity correction map of myocardial perfusion SPECT (심근 관류 SPECT에서 핵종에 따른 Uniformity correction map 설정을 통한 영상의 질 비교)

  • Song, Jae hyuk;Kim, Kyeong Sik;Lee, Dong Hoon;Kim, Sung Hwan;Park, Jang Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.87-92
    • /
    • 2015
  • Purpose When the patients takes myocardial perfusion SPECT using $^{201}Tl$, the operator gives the patients an injection of $^{201}Tl$. But the uniformity correction map in SPECT uses $^{99m}Tc$ uniformity correction map. Thus, we want to compare the image quality when it uses $^{99m}Tc$ uniformity correction map and when it uses $^{201}Tl$ uniformity correction map. Materials and Methods Phantom study is performed. We take the data by Asan medical center daily QC condition with flood phantom including $^{201}Tl$ 21.3 kBq/mL. After postprocessing with this data, we analyze CFOV integral uniformity(I.U) and differential uniformity(D.U). And we take the data with Jaszczak ECT Phantom by American college of radiology accreditation program instruction including $^{201}Tl$ 33.4 kBq/mL. After post processing with this data, we analyze spatial Resolution, Integral Uniformity(I.U), coefficient of variation(C.V) and Contrast with Interactive data language program. Results In the flood phantom test, when it uses $^{99m}Tc$ uniformity correction map, Flood I.U is 3.6% and D.U is 3.0%. When it uses $^{201}Tl$ uniformity correction map, Flood I.U is 3.8% and D.U is 2.1%. The flood I.U is worsen about 5%, but the D.U is improved about 30% inversely. In the Jaszczak ECT phantom test, when it uses $^{99m}Tc$ uniformity correction map, SPECT I.U, C.V and contrast is 13.99%, 4.89% and 0.69. When it uses $^{201}Tl$ uniformity correction map, SPECT I.U, C.V and contrast is 11.37%, 4.79% and 0.78. All of data are improved about 18%, 2%, 13% The spatial resolution was no significant changes. Conclusion In the flood phantom test, Flood I.U is worsen but Flood D.U is improved. Therefore, it's uncertain that an image quality is improved with flood phantom test. On the other hand, SPECT I.U, C.V, Contrast are improved about 18%, 2%, 13% in the Jaszczak ECT phantom test. This study has limitations that we can't take all variables into account and study with two phantoms. We need think about things that it has a good effect when doctors decipher the nuclear medicine image and it's possible to improve the image quality using the uniformity correction map of other radionuclides other than $^{99m}Tc$, $^{201}Tl$ when we make other nuclear medicine examinations.

  • PDF

Ecological Characteristics of Local Collections of Cyperus serotinus Rottb. and Their Geographical Differentiation (너도방동산이 지방수집종(地方蒐集種)들의 생태적(生態的) 특성(特性) 및 그의 생리적(生理的) 분화(分化)에 관한 연구(硏究))

  • Seong, Ki-Yeong;Kwon, Yong-Woong
    • Korean Journal of Weed Science
    • /
    • v.3 no.1
    • /
    • pp.14-22
    • /
    • 1983
  • To study ecological characteristics of Cyperus serotinus occuring in Korea its propagules were collected from 6 locations from the northern part to the southern part of Korea (Chuncheon, Suweon, Iri, Jeonju, Gwangju, Milyang) in 1981, cultured and replanted 4 times (May 20, June 5, June 20, July 5) in 1982. They flowered from August 10 to August 29 in the plants planted on May 20 and from August 22 to September 4 in the plants planted on July 5. Plant height, number of tillers and top fresh weight were 85-100cm, 375-1,500 tillers/$m^2$ and 500-1,750g/$m^2$, respectively, when they were planted on May 20, and 58-67cm, 300-625 tillers/ $m^2$ and 125-250g/$m^2$, respectively, when they were planted on July S. Weight of seeds and number of rhizomes per plant were 20-50g/$m^2$ and 20.75-61, respectively, whey, they were planted on May 20, and 5-17.5g/$m^2$ and 51.5-80.25 when they were planted on July 5. Local collections showed. the same morphological characteristics at the level of species identification, but there existed variations among the local collections. Cyperus serotinus from Chuncheon and Suweon were longer in the length of inflorescence, than those from Gwangju and Milyang and rhizomes from Chuncheon and Suweon were thicker than the others. Each of local collections may be regarded as different ecotype based on the above mentioned differences in morphology, growth and flowering response to the planting date. The results appear to imply that Cyperus serotinus weeds occuring in various locations of Korea are different one another in competitive ability with rice crop.

  • PDF

The Content of Minerals and Vitamins in Commercial Beverages and Liquid Teas (유통음료 및 액상차 중의 비타민과 미네랄 함량)

  • Shin, Young;Kim, Sung-Dan;Kim, Bog-Soon;Yun, Eun-Sun;Chang, Min-Su;Jung, Sun-Ok;Lee, Yong-Cheol;Kim, Jung-Hun;Chae, Young-Zoo
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.4
    • /
    • pp.322-329
    • /
    • 2011
  • This study was done to analyze the contents of minerals and vitamins to compare the measured values of minerals, vitamins with labeled values of them in food labeling and to investigate the ratio of measured values to labeled values in 437 specimen with minerals and vitamins - fortified commercial beverages and liquid teas. Content of calcium and sodium in samples after microwave digestion was analyzed with an ICP-OES (Inductively Coupled Plasma Optical Emission Spectrometer) and vitamins were determined using by HPLC (High Performance Liquid Chromatography). The measured values of calcium were ranged 80.3~142.6% of the labeled values in 21 samples composed calcium - fortified commercial beverages and liquid teas. In case of sodium, measured values were investigated 33.9~48.5% of the labeled values in 21 sports beverages. The measured values of vitamin C, vitamin $B_2$ and niacin were ranged 99.7~2003.6, 81.1~336.7, 90.7~393.2% of the labeled values in vitamins - fortified commercial beverages and liquid teas, 57, 12, 11 samples. To support achievement of the accurate nutrition label, there must be program and initiatives for better understanding and guidances on food labelling and nutrition for food manufacture.

Edge to Edge Model and Delay Performance Evaluation for Autonomous Driving (자율 주행을 위한 Edge to Edge 모델 및 지연 성능 평가)

  • Cho, Moon Ki;Bae, Kyoung Yul
    • Journal of Intelligence and Information Systems
    • /
    • v.27 no.1
    • /
    • pp.191-207
    • /
    • 2021
  • Up to this day, mobile communications have evolved rapidly over the decades, mainly focusing on speed-up to meet the growing data demands of 2G to 5G. And with the start of the 5G era, efforts are being made to provide such various services to customers, as IoT, V2X, robots, artificial intelligence, augmented virtual reality, and smart cities, which are expected to change the environment of our lives and industries as a whole. In a bid to provide those services, on top of high speed data, reduced latency and reliability are critical for real-time services. Thus, 5G has paved the way for service delivery through maximum speed of 20Gbps, a delay of 1ms, and a connecting device of 106/㎢ In particular, in intelligent traffic control systems and services using various vehicle-based Vehicle to X (V2X), such as traffic control, in addition to high-speed data speed, reduction of delay and reliability for real-time services are very important. 5G communication uses high frequencies of 3.5Ghz and 28Ghz. These high-frequency waves can go with high-speed thanks to their straightness while their short wavelength and small diffraction angle limit their reach to distance and prevent them from penetrating walls, causing restrictions on their use indoors. Therefore, under existing networks it's difficult to overcome these constraints. The underlying centralized SDN also has a limited capability in offering delay-sensitive services because communication with many nodes creates overload in its processing. Basically, SDN, which means a structure that separates signals from the control plane from packets in the data plane, requires control of the delay-related tree structure available in the event of an emergency during autonomous driving. In these scenarios, the network architecture that handles in-vehicle information is a major variable of delay. Since SDNs in general centralized structures are difficult to meet the desired delay level, studies on the optimal size of SDNs for information processing should be conducted. Thus, SDNs need to be separated on a certain scale and construct a new type of network, which can efficiently respond to dynamically changing traffic and provide high-quality, flexible services. Moreover, the structure of these networks is closely related to ultra-low latency, high confidence, and hyper-connectivity and should be based on a new form of split SDN rather than an existing centralized SDN structure, even in the case of the worst condition. And in these SDN structural networks, where automobiles pass through small 5G cells very quickly, the information change cycle, round trip delay (RTD), and the data processing time of SDN are highly correlated with the delay. Of these, RDT is not a significant factor because it has sufficient speed and less than 1 ms of delay, but the information change cycle and data processing time of SDN are factors that greatly affect the delay. Especially, in an emergency of self-driving environment linked to an ITS(Intelligent Traffic System) that requires low latency and high reliability, information should be transmitted and processed very quickly. That is a case in point where delay plays a very sensitive role. In this paper, we study the SDN architecture in emergencies during autonomous driving and conduct analysis through simulation of the correlation with the cell layer in which the vehicle should request relevant information according to the information flow. For simulation: As the Data Rate of 5G is high enough, we can assume the information for neighbor vehicle support to the car without errors. Furthermore, we assumed 5G small cells within 50 ~ 250 m in cell radius, and the maximum speed of the vehicle was considered as a 30km ~ 200 km/hour in order to examine the network architecture to minimize the delay.

Establishment of Embryonic Stem Cell Line from Isolated Blastomeres from Mouse Preimplantation Embryos (생쥐 초기 배아에서 분리한 할구를 이용한 배아줄기세포주 확립)

  • Lim, Chun Kyu;Sung, Ji Hye;Choi, Hye Won;Cho, Jae Won;Shin, Mi Ra;Jun, Jin Hyun
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.33 no.1
    • /
    • pp.25-33
    • /
    • 2006
  • Objective: The aim of this study was to investigate whether embryonic stem (ES) cells can be established from isolated blastomeres of mouse embryos. Methods: Blastomeres were separated from mouse (C57Bl/6J) 2- or 4-cell embryos. Isolated blastomeres or whole 4-cell embryos were co-cultured with mitosis-arrested STO feeder cells in DMEM supplemented with recombinant murine leukemia inhibitory factor and ES-qualified fetal bovine serum. After the tentative ES cell lines were maintained from isolated blastomeres or whole embryos, some of them were frozen and the others were sub-cultured continually. Characteristics of tentative ES cell lines as were evaluated for specific genes expressions with immunocytochemistry and RT-PCR. Results: One ES cell line (3.0%) was established from isolated blastomere of 2-cell embryo and one cell line (4.0%) from isolated two blastomeres of 4-cell embryo. And five cell lines (16.7%) were established from whole 4-cell embryos. Both cell lines from isolated blastomere and whole embryo expressed mouse ES cell specific markers such as SSEA-1, Oct-4 and alkaline phosphatase. Marker genes of three germ layers were expressed from embryoid bodies of both cell lines. Conclusion: This study suggests that mouse ES cells could be established from isolated blastomeres, although the efficiency is lower than whole embryos. This animal model could be applied to establishment of autologous human ES cells from biopsied blastomeres of preimplantation embryos in human IVF-ET program.

Effects of Aluminum Sulfate Addition on Six-Week-Old Broiler Performance and Nitrogen Contents in Litter at the Sixth Week (Aluminum Sulfate 처리가 6주령 육계생산 능력 및 깔짚 내의 질소 함량에 미치는 영향)

  • 최인학;남기홍
    • Korean Journal of Poultry Science
    • /
    • v.29 no.4
    • /
    • pp.265-270
    • /
    • 2002
  • This study was conducted to determine the effect of aluminum sulfate[Al$_2$(S0$_4$)$_3$$.$14H$_2$O], commonly referred to as ALUM, addition to broiler litter on 3 and 6 week old broiler performance and the nitrogen content of the litter at 6 weeks of age. The two treatment groups were 134 identical diets with the same protein levels, but one group(T$_1$) had ALUM added as a top dressing to the litter at a rate of 200 g ALUM / kg of rice bran, while T$_2$ did not have ALUM added to the litter. Feed consumption for T$_1$ was higher in the 22 to 42 day-old and 0 to 42 day-old periods (P<0.05). Body weight in T$_1$ was also higher in the 0 to 42 day -old period (P<0.0l). There was no difference, however, in the feed : gain ratio between T$_1$ and T$_2$ During the first 5 weeks, T$_1$ had significantly less(P<0.05 or 0.01) ammonia emission from the litter than T$_2$ but at 6 weeks there was no difference in ammonia concentration between the two groups. At 6 weeks, T$_1$ had a lower litter pH than Ta (P<0.05) and total Kjeldahl nitrogen(TKN) was higher far T$_1$ than T$_2$ (P<0.05). However,71 did not show any difference from T$_2$ in the content of NH4-N and NO3-N. In summary, the addition of ALUM to broiler litter improved broiler performance at 6 weeks, while increasing nitrogen content from the litter used as the nitrogen fertilizer although ammonia emission was increased in T$_1$ at 6 weeks.

Analysis of the Perception of Hospice and Narcotic Analgesics by Family Caregivers of Terminal Cancer Patient (말기 암 환자 보호자의 호스피스와 마약성 진통제에 대한 인식도 분석)

  • Kwak, Kyung-Sook;Chun, Sung-Ho;Ha, Jung-Ok;Lee, Kyung-Hee
    • Journal of Hospice and Palliative Care
    • /
    • v.9 no.2
    • /
    • pp.106-111
    • /
    • 2006
  • Purpose: In terminal cancer patients, pain control with narcotic analgesics and supportive care by hospice are very useful treatment modality. However, many patients and their caregivers are poorly compliant in using narcotic analgesics for fear of addiction and tolerance. And also many patients and family caregivers are reluctant to accept hospice, presuming that hospice means patient's condition is no longer reversible and progressively deteriorating. The purpose of this study was to evaluate and analyze the perception of using narcotic analgesics and hospice by family caregivers of terminal cancer patients who play a critical role in health care in Korean culture. Methods: A total of 54 terminal ranter patient's family caregivers participated in this study. Questionnaire consisted of 15 questions about narcotic analgesics and hospice. Results: The study revealed following results. 1) family caregivers who are not aware of hospice are more than half (56.7%). 2) 81.8% of family caregivers agreed that hospice care is beneficial to terminal cancer patients. 3) 85.1% of family caregivers were under financial burden. 4) 83.2% of patient complained pain in 24 hours. 3) while 88.5% of family caregivers believed that narcotic analgesics can control pair, 79.1% and 79.6% of them also believed that use of narcotic analgesics would result in addiction and tolerance, respectively. Conclusion: There still exist barriers to family caregivers in using narcotic analgesics for pain control. And also, terminal cancer patient's family caregivers have poor information about hospice. Therefore, educational intervention about narcotic analgesics by pharmacist and doctors are needed for proper pain control for terminal ranter patients. In addition, more precise information about hospice care should be provided for terminal cancer patients and their family caregivers.

  • PDF

The analyses of duplicated contents of 'Consumer Life' area in Technology & Home Economics and other subject textbooks for middle and high school students (중·고등학교 기술·가정 교과서와 타 교과 교과서의 '소비생활' 영역 중복 내용 분석)

  • Lee, Jung Yoon;Yu, Nan Sook
    • Journal of Korean Home Economics Education Association
    • /
    • v.27 no.4
    • /
    • pp.121-140
    • /
    • 2015
  • The purposes of this study were to analyze the duplicated contents of 'Consumer life' area of Technology & Home Economics and other subject textbooks for the middle and high school students. It focused on textbooks compiled following the 2009 revised curriculum. To achieve the purposes of this study, "Technology & Home Economics I II", "Social studies I II", and "Ethics I II"textbooks for middle school and "Technology & Home Economics", "Social studies", and "Life & Ethics" textbooks for high school were analyzed based on the criteria for analyses of 'Consumer life' area. The results were as follows. First, the analysis of duplicated contents in Technology & Home Economics and other subjects (Ethics, Social studies) for middle school revealed that Technology & Home Economics textbook had the most proportion of 'Consumer Life' area, followed by Social studies and Ethics. The duplicated content elements in Technology & Home Economics, Ethics, and Social studies textbooks for middle school were 'consumer decision making', 'consumer information', 'economic impact of consumption', 'food life and sustainability', and 'consumption and sustainability'. Secondly, as a result of the content analysis of textbooks for high school Technology & Home Economics, Social studies, and Life & Ethics according to the criteria of analysis, it was found that Technology & Home Economics textbook had the most proportion of 'Consumer Life' area, followed by Life & Ethics and Social studies. The "content elements" 'food life management and consumption environment', 'desire of consumption', 'economic impact of consumption', 'changing factors and characteristics of consumer culture', and 'consumption and sustainability' were commonly found in all three textbooks. In this way, the 'Consumer life' area of Technology & Home Economics is thought to play a central role in teaching the 'Consumer Life' area because of its strength that contains detailed contents about consumer life for adolescent consumers who will apply it to everyday life. Based on the result of this research, it is needed to consider articulation of 'Consumer life' area of secondary schools for the future curriculum development of Technology & Home Economics to reduce the duplicated contents and to help the adolescents develop the ability to solve consumption problems they may encounter in real life and grow up to be rational adult consumers.

A study on the school health education curriculum development focused on the health education course in primary school (국민학교 보건교육 교과과정의 개선방안에 대한 연구)

  • Kim, Hwa-Joong;Lee, In-Sook
    • Journal of the Korean Society of School Health
    • /
    • v.5 no.1
    • /
    • pp.36-63
    • /
    • 1992
  • The purpose of this study was development of school health education curriculum in primary school based on analysis of the textbooks published in 1991. 1) The health education curriculum in primary school consisted of four major components such as health education aspects of the healthful school environments, health education aspects of school health services, health education course, and health instruction in related subjects. However, health instruction taught by physical education, biology, and other health related subjects was not systematic organization for health care. 2) A considerable amount of health knowledge and attitude, and some health practices was learned as the result of experiences in other courses, where there was little or no reference to health. It must be developed health edcation course separated from health related subjects. 3) Direct health insruction was represented by the health education course. The health education courses must be considered to be heart of the school health education curriculum. 4) The health education course developed by this study was consisted of eight health units and problems in the early elementary grade or health classes in the higher years. 5) The health education course developed by this study provided the opportunity for acquring new knowledge, attitude, and practice, for discarding the unhealtful attitude and strengthening the healthful attitude and practices of primary school students.

  • PDF

Evaluation of the reconstruction of image acquired from CT simulator to reduce metal artifact (Metal artifact 감소를 위한 CT simulator 영상 재구성의 유용성 평가)

  • Choi, Ji Hun;Park, Jin Hong;Choi, Byung Don;Won, Hui Su;Chang, Nam Jun;Goo, Jang Hyun;Hong, Joo Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.191-197
    • /
    • 2014
  • Purpose : This study presents the usefulness assessment of metal artifact reduction for orthopedic implants(O-MAR) to decrease metal artifacts from materials with high density when acquired CT images. Materials and Methods : By CT simulator, original CT images were acquired from Gammex and Rando phantom and those phantoms inserted with high density materials were scanned for other CT images with metal artifacts and then O-MAR was applied to those images, respectively. To evaluate CT images using Gammex phantom, 5 regions of interest(ROIs) were placed at 5 organs and 3 ROIs were set up at points affected by artifacts. The averages of standard deviation(SD) and CT numbers were compared with a plan using original image. For assessment of variations in dose of tissue around materials with high density, the volume of a cylindrical shape was designed at 3 places in images acquired from Rando phantom by Eclipse. With 6 MV, 7-fields, $15{\time}15cm2$ and 100 cGy per fraction, treatment planning was created and the mean dose were compared with a plan using original image. Results : In the test with the Gammex phantom, CT numbers had a few difference at established points and especially 3 points affected by artifacts had most of the same figures. In the case of O-MAR image, the more reduction in SD appeared at all of 8 points than non O-MAR image. In the test using the Rando Phantom, the variations in dose of tissue around high density materials had a few difference between original CT image and CT image with O-MAR. Conclusion : The CT images using O-MAR were acquired clearly at the boundary of tissue around high density materials and applying O-MAR was useful for correcting CT numbers.