• Title/Summary/Keyword: 반전법

Search Result 115, Processing Time 0.037 seconds

A Study on Magnetoresistance Uniformity of NiFE/CoFe/AlO/CoFe/Ta TMR Devices Prepared by ICP Sputtering (ICP 스퍼터를 이용한 NiFe/CoFe/AlO/CoFe/Ta TMR 소자 제작에 있어서의 자기저항 균일성 연구)

  • 이영민;송오성
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.5
    • /
    • pp.189-195
    • /
    • 2001
  • We prepared TMR junctions of NiFe(170 )/CoFe(48 )/Al(13 )-O/CoFe(500 )/Ta(50 ) structure on 2.5$\times$2.5 $\textrm{cm}^2$ area Si/SiO$_2$ substrates in order to investigate the uniformity of magnetoresistance(MR) value using a ICP magnetron sputter. Each layer was deposited by the ICP magnetron sputter and tunnel barrier was formed by the plasma oxidation method. We measured MR ratio and resistance of TMR devices with four-terminal probe system by applying external magnetic field. Although we used ICP sputter which is known as superior to make uniform films, the standard variation of MR ratio was 2.72. The variation was not dependent on the TMR devices location of a substrate. We found that MR ratio and spin-flip field (H's) increased as the resistance increased, which may be caused by local interface irregularity of the insulating layer. The variation of resistance value was 64.19 and MR ratio was 2.72, respectively. Our results imply that to improve the insulating layer fabrication process including annealing process to lessen interface modulation in order to mass produce the TMR devices.

  • PDF

Source finding in reflection and refraction environment using based on ray tracing method TRM (음선 추적법 기반 TRM을 이용한 반사 및 굴절 환경 속의 소음원 탐색에 대한 연구)

  • Moon, Sang Il;Lee, Jae Hyung;Choi, Jong Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.727-732
    • /
    • 2014
  • The goal is to find the position of the sound source with the TRM at reflections and refractions environment. The Fermat's principle applied to the ray tracing method are expected to follow the acoustic path in order to obtain acoustic distance and transmittance to. Utilizing them in the TRM was confirmed rear reflectance affect on estimated position, resolution and side lobe. And the TRM performance were superior to one of the beam forming techniques.

  • PDF

Analysis of the Deductive Inference in Engineering Education through the Experiment of Elliptical Trainers (Elliptical Trainer의 실험 분석을 통한 공학교육에 적용되는 귀납법적 추론 분석)

  • Hwang, Un Hak
    • The Journal of Korean Institute for Practical Engineering Education
    • /
    • v.5 no.1
    • /
    • pp.1-13
    • /
    • 2013
  • For a basic engineering education the confirmation and verification of the deductive Inference was studied and the principle of probability inference was applied. The background of introduction of deductive Inference and its test method was mentioned, and historic arguments on the compatibility of deductive statistical inference was summarized and analyzed. Philosophical arguments on the deductive confirmation for engineering experiments was introduced. Premise, procedure, and control of the experiments are studied. As an example of the deductive probability inference three groups of experimental data were used in order to find successful inferences respectively.

  • PDF

Molecular and Crystal Structure of' Metalaxyl, $C_{15}H_{21}NO_4$ (Metalaxyl, $C_{15}H_{21}NO_4$의 분자 및 결정구조)

  • Keun Il Park;Young Kie Kim;Sung Il Cho;Man Hyung Yoo
    • Korean Journal of Crystallography
    • /
    • v.13 no.3_4
    • /
    • pp.148-151
    • /
    • 2002
  • The molecular and crystal structure of metalaxyl C/sub15/H/sub21/NO₄, was determined by single crystal x-ray diffraction study. Crystallographic data for, title compound P2₁/c, a=7.849(4) Å, b=13.081(5) Å, c=15.100(3) Å, β=101.8(2)°, V= 1517.6(3) ų, Z=4. The molecular. Structure model was solved by direct method and refined by full-matrix least- squares. The final reliable factor, R, is 0.067 for 1694 independent reflections (F/sub o//sup 2/>4σ(F/sub o//sup 2/)). The molecular structure of title compound shows an intramolecular hydrogen bond: Cl2-Hl2A…O1.

Measurement of Five DOF Motion Errors in the Ultra Precision Feed Tables (초정밀 이송테이블의 5 자유도 운동오차 측정)

  • Oh Yoon Jin;Park Chun Hong;Hwang Joo Ho;Lee Deug Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.11 s.176
    • /
    • pp.135-141
    • /
    • 2005
  • Measurement of five DOF motion errors in a ultra precision feed table was attempted in this study. Yaw and pitch error were measured by using a laser interferometer and roll error was measured by using the reversal method. Linear motion errors in the vertical and horizontal directions were measured by using the sequential two point method. In this case, influence of angular motion errors was compensated by using the previously measured ones by the laser interferometer and the reversal method. The capacitive type sensors and an optical straight edge were used in the reversal method and the sequential two point method. Influence of thermal deformation on sensor jig was investgated and minimized by the periodic measurement according to the variation of room temperature. Deviation of gain between sensors was also compensated using the step response data. 5 DOF motion errors of a hydrostatic table driven by the linear motor werer tested using the measurement method. In the horizontal direction, measuring accuracies for the linear and angular motion were within ${\pm}0.02\;{\mu}m$ and ${\pm}0.04$ arcsec, respectively. In the vertical direction, they were within ${\pm}0.02{\mu}m$ and ${\pm}0.05$ arcsec. From these results, it was found that the introduced measurement method was very effective to measure 5 DOF motion errors of the ultra precision feed tables.

Contrast Improvement in Diagnostic Ultrasound Strain Imaging Using Globally Uniform Stretching (진단용 초음파 변형률 영상에서 전역 균일 신장에 의한 콘트라스트 향상)

  • Kwon, Sung-Jae;Jeong, Mok-Kun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.8
    • /
    • pp.504-508
    • /
    • 2010
  • In conventional diagnostic ultrasound strain imaging, when displaying strain image on a monitor, human visual characteristics are utilized such that hard regions are displayed as dark and soft regions are displayed as bright. Thus, hard regions representing tumor or cancer are displayed as dark, decreasing the contrast inside the lesion. Because the lesion area is stiff and thus displayed as dark, a method of inverting the image brightness and thereby increasing the contrast in the lesion for better diagnostic purposes is proposed wherein a postcompression signal is extended in the time domain by a factor corresponding to the reciprocal of the amount of the applied compression using a technique termed globally uniform stretching. Experiments were carried out to verify the proposed method on an ultrasound elasticity phantom with radio-frequency data acquired from a diagnostic ultrasound clinical scanner. It is found that the new method improves the contrast-to-noise ratio by a factor of up to about 1.8 compared to a conventional strain imaging method that employs a reversed gray color map without globally uniform stretching.

An Experimental Study on Relationship Between Half-Cell Potential and Corrosion Current Density of Chloride-Induced Corroded Steel in Concrete (염해에 따라 콘크리트 속에서 부식된 철근의 반전지전위와 부식전류밀도의 상관관계에 관한 실험적 연구)

  • Jo, Sang-Hyeon;Kim, Dong-Won;Kee, Seong-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.1-13
    • /
    • 2022
  • This study aims to investigate the feasibility of the half-cell potential (HCP) measurements on the concrete surface for evaluation of corrosion rate (or corrosion levels) of reinforcing steel in concrete. A series of experimental study is performed to measure HCP (or corrosion potential, Ecorr) and corrosion current density (icorr) of reinforcing steel in concrete cube specimens, with a side length of 200 mm. Various corrosion levels in a range of 0% to 20% of the test specimens are accelerated by impressing current to the reinforcing steel in concrete immersed in 3.0 % NaCl solution. HCP is measured in accordance with ASTM C876-15, and corrosion current density is determined by using the Stern-Geary equation and measured polarization resistance measured by electrochemical impedance spectroscopy (EIS). As a result, a numerical formula that relates HCP and icorr in the test specimen is established by a regression analysis of the measured data in this study. It is observed that HCP is linearly correlated with log(icorr) with a R2 greater than 0.87, which is less affected by the experimental variables such as concrete mixture proportion, diameter of reinforcing steel and the amount of applied current in this study. These results exhibit that HCP measurements could be effective for evaluation of corrosion rate (or corrosion levels) of reinforcing steel in concrete in the case of exposed to a certain consistent environment.

Analysis of the Radiation Pattern of a Microstrip Array Antenna on a Non-Planar Surface by using FOURIER TRANSFORM (FOURIER TRANSFORM을 이용한 비평면형 마이크로스트립 어레이 안테나의 복사패턴 해석)

  • 고광태;구연건
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.15 no.9
    • /
    • pp.785-795
    • /
    • 1990
  • For the far field radiation pattern of a microstrip array antenna which is conformed to a cylindrical surface and forms an arc array, an approximate analysis method using FOURIER TRANSFORM is presented. In this method, the conformal array antenna is projected on the effective aperture plane and assumed to be an aperiodic array with nonlinear phase tilt. The effective aperture plane includes four end-points of each arc on the cylindrical surface. When the effective aperture ratio which is normalized to the planar type is from 1.0 to 0.9, it is confirmed that this approximate method is valid. To the array on the effective aperture plane, it is assumed that the phase tilt is due to the distance between aperture plne and curvature surface. Specially, when the radius of arc is more than 5 times to its length, the FOURIER TRANSFORM METHOD could be used with only varying scale factors. The results of calculating by approximate method are good agreement with the results of COORDINATE TRANSFORM METHOD and experimentally measured value in the range of -40dB. And, the difference of half power angle is less than 5 degrees when the effective aperture ratio moer than 0.9.

  • PDF

Consideration the Writing and Reproducting Pattern of Isolated Transition of Magnetization in Perpendicular Magnetic Recording System by using F.E.M. (유한요소법에 의한 수직자기기록장치의 단일자화반전기록 및 재생에 관한 고찰)

  • Lee, Hyang-Beom;Park, Gwan-Soo;Hahn, Song-Yop
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.28-31
    • /
    • 1990
  • In perpendicular magnetic recording system, the magnetic recording and reproduction characteristics of isolated transition of magnetization is simulated in this paper. The recording system which is magneto-static system is analyzed using two-dimensional finite element method and the characteristics of hysteresis of recording media is considered. The results show that the optimizing current is exist in magnetic recording system.

  • PDF

Radial Density Distributions in the Positive Column of a Strongly Modulated Mercury-rare gas AC Discharge (변조된 수은-희유기체 교류방전의 양광주 내의 반경방향 입자분포)

  • 이진우;여인선
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.2
    • /
    • pp.31-35
    • /
    • 1993
  • The radial density distributions of the positive column of strongly modulated low -pressure gas discharges in mercury - rare gas mixtures at 10 tom pressure have been studied theoretically. The current was modulated inusoidally with a modulation depth of 50%. Calculations have shown that the radial profile of the excited atoms is ditferent form 0th Bessel function $J_0$(2.4r/R) and the invertion of the radial distribution of the excited atom can occur at some frequency. The hybrid method of FDM and 2nd order Runge-Kutta meth od is used for solving differenzial equations.

  • PDF