• Title/Summary/Keyword: 바닥구조

Search Result 948, Processing Time 0.025 seconds

Analysis of the Cause of Waterleakage in Residential Apartment Underground Parking Ground and the Review of the Repare Methods (공동주택 지하주차장의 누수원인 분석 및 보수방안 검토)

  • Oh, Sang-Keun;Choi, Sung-Min;Song, Je-Young
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.3
    • /
    • pp.255-264
    • /
    • 2014
  • This study analyzes the cause and the repairing method of water leak by parts of basement parking lot which is recorded to have a high defect frequency in apartment buildings. It has been assessed that the cause of water leakage on the first floor upper substrate is due to such factors as landscaping and weights. During construction or through other cases, it has been determined that cracks were produced in the apartment structure because the structure was weak and exposed to the effects of the substrate movement. The base floor and underground external walls are areas that are exposed to water pressure (uplife pressure), thus in normal cases the rear surface repair of the structure using sythetic rubberized polymer gel should be considered as an effective method. However, in cases where application of waterproofing layer is required in the structure due to high water pressure, using asystolic cement milk grout to form the waterproofing layer and applying water-swelling acrylic material into the cracked areas is considered to be highly effective.

Field Tests and Analysis of Groundwater System for Stabilization of Slope in Large Open-Pit Coal Mine (대규모 노천 석탄광산의 사면 안정화를 위한 지하수 유동 체계 분석)

  • Ryu, D.W.;Kim, H.M.;Oh, J.H.;Sunwoo, C.;Jung, Y.B.
    • Tunnel and Underground Space
    • /
    • v.19 no.3
    • /
    • pp.248-260
    • /
    • 2009
  • With regard to oversea mineral resources development, recent trend has been changed from a simple capital investment to a direct development of the resources. In relation to the stability of a slope in large open-pit coal mine, groundwater system was investigated and the validity of horizontal drainage hole was evaluated in Pasir coal mine, Indonesia. In this work, various field tests were carried out for a characterization of groundwater system, which included in-situ permeability measurement, tracer test and monitoring of groundwater levels. Especially, the influence of SM river on the characteristics of the groundwater flow system was mainly inspected. For the permeability measurement, Guelph permeameter was employed, and was found that sandstone was more permeable than mudstone and coal seam. From a comparison of lithological structure and the results of groundwater level monitoring, sandstone and thin coal seam with fractures were found to be a main channel for groundwater flow. In the results of tracer tests, the effect of SM river on the groundwater system depends on the geological structure of its base. To identify the effect of horizontal drainage holes, 2-D groundwater modeling was performed. Four different cases were tested, which are different from the length of drainage hole and the existence of pond on top of the slope. To enhance the drainage effect and slope stability, the drainage hole should be drilled to the depth of coal seam layer, which provides a main pathway of groundwater flow and embedded by sandstone. For this purpose, correct identification of surrounding geology should be preceded.

Rare Metal Chemistry, Microstructures, and Mineralogy of Coal Ash from Thermal Power Plants of Korea (화력발전소 석탄회의 희유금속화학, 미세구조, 광물학적 특성)

  • Jeong, Gi Young;Kim, Seok-Hwi;Kim, Kangjoo
    • Journal of the Mineralogical Society of Korea
    • /
    • v.28 no.2
    • /
    • pp.147-163
    • /
    • 2015
  • Chemical and mineralogical properties of coal ash samples from the nine thermal power plants of Korea were investigated to acquire basic data for estimating the potential of rare metal recovery. Chemical compositions of coal ash were consistent with those of average shale and foreign coal ashes. However, there were small differences between the metal contents of domestic anthracitic and imported bituminous coal ashes. Unburned coal particles were much abundant in the ash of domestic anthracitic coal. Chalcophile elements were relatively enriched in the fly ash compared to bottom ash. Silicate glass was the major component of coal ash with minor minerals such as quartz, illite (muscovite), mullite, magnetite, lime, and anhydrite. Al and Si were the major components of the glass with varying contents of Ca, Fe, K, and Mg. Glass occurred in a form of porous sphere and irregular pumace-like grain often fused with iron oxide spheres or other glass grains. Iron oxide spheres were fine intergrowth of fast-grown iron oxide crystals in the matrix of silicate glass. Chemical, microstructural, and mineralogical properties would guide successful rare metal recovery from coal ash.

A Study on the Standard Drawings of Seoul Middle School Architecture in 1975 (1975년 서울시 중학교 표준설계도에 관한 연구)

  • Lee, Jeong-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2497-2504
    • /
    • 2013
  • This study aims to analyze the 'Standard Drawings for School Facilities' issued by Seoul Education Committee in 1975 because it is the early example for middle school architecture. The results of this study are summarized as follows 1) In general trend of single-corridor type block plan, there are also changes in floor plan like no-corridor type block plan, $9.9{\times}6.6m$ classroom unit for the better daylight condition, built-in storage for students. 2) As for elevation design, it is characterized as daylight-oriented, functional exterior for without making full use of design elements. 3) Standardized dimensions are used as a rule in the height of story, ceiling, window sill and etc. Transitional characteristics of the early RC school architecture are found in exposed ceiling, incomplete insulation structure and mixed use of wood framed floor of earlier type. 4) Contrast to main school building, gymnasium shows the intend to express the symbolism of school architecture with diverse elevation design elements and the plasticity of building mass. 5) Separated plan of toilet and night-duty building also show the transitional characteristics. As conclusion, though showing the stereotyped school architecture, on the other hand, 'Standard Drawings for School Facilities' (1975) makes it possible to see the way of coping with the demands for school architecture in that time and the transition of school architecture. This is the main value of it as the material for the studies related to the history of educational facilities.

A Study on the Design Concept & Construction Method of Office Building with Stacks at Thermal Power Plant (화력발전소 연돌통합형 종합사무동의 설계개념과 시공공법 연구)

  • Kim, Si-Hyun;Choi, Jang-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.677-686
    • /
    • 2016
  • A thermal power plant is the first CFBC (Circulating Fluidized Bed Combustion) power plant consisting of 2 boilers-1 turbine. The optimal height of a stack needs to be approximately 156 meters in the case of this thermal power plant; however, the thermal power plant sites satisfy a function and reduce the construction cost by using mountains in the sites after cutting the ground and locating an integrated office and chimney at an altitude of 70 meters thereby lowering the height of the stack to 86 meters. In addition, the integrated office, which has a combined stack style with a unique design, is constructed by connecting with 2 stacks and disposing the office and an observatory in the space between them. Therefore, this study examined the design concept that fulfils the structural, functional, and aesthetic factors, harmoniously by joining the integrated office and the stack, which are disparate, and investigated special construction methods (Slip Form, Steel Inner Flue & Lift-up) through which heterogeneous architectures are structurally, functionally, and aesthetically constructed.

An Experimental Study for the Empirical Equation to Quantify the Subsidence of Riprap Scour Protection at Downstream of Vertical Drop Structures (연직낙차공 하류부 사석보호공 침하량 산정식에 관한 실험 연구)

  • Kim, Chang-Sung;Kang, Joon-Gu;Yeo, Hong-Koo;Yeo, Woon-Kwang
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.5
    • /
    • pp.433-443
    • /
    • 2010
  • Drop structures that span the entire width of channels are installed to alleviate channel grades and have been constructed widely in Korean rivers. Aprons are normally installed and integrated with drop structures and bed protections are added on the downstream part of aprons to protect both drop structures and aprons. Scour occurring on aprons is reported to provide various habitats such as ripples and pools in natural rivers. This study focuses on the scour characteristics on an apron integrated with a drop structure and the subsidence of a riprap protection. The scour depth on the downstream part of the drop structure is found to increase with the increase of unit discharge; however, to decrease as the tail water depth gets deeper. Based on the experimental measurements, the subsidence of the riprap scour protection is calculated with respect to the thickness of riprap. Finally, the dimensionless empirical equation to quantify the subsidence of the riprap scour protection without filters at downstream of the vertical drop is suggested.

Deflection Evaluation of the Constructing-load Carrying Capacity for Deep Decking Floor System Reinforced with Both Ends Cap Plates (캡 플레이트로 단부 보강한 춤이 깊은 데크의 시공중 처짐성능평가)

  • Jeon, Sang Hyun;Kyung, Jae Hwan;Kim, Young Ho;Choi, Sung Mo;Yang, Il Seung
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.2
    • /
    • pp.155-167
    • /
    • 2015
  • If of application of the deep deckting floor in long span more than 6m, the deflection caused by the construction load occurred high. Because the constructing-works and safety by this deflection, take actually supports to laborers working on the deck. However, installed supports are having difficultly such as the restricted passage, deficiency of working space, and lowering of efficiency. And toward-opening deck is seen as local buckling of web plate, flexural-torsional buckling, and gradually opening of corrugated decking. In this study, we will suggest a deep decking floor system that reinforced with both ends cap plates for toward-opneing decking change from opening to closing. The constructing deflection of a deep decking more than 6m must be satified 30mm and L/180 as proposed. Full-scale field tests loading by sand conducted a deep decking reinforced with and without cap plate. In conclusion, the specimen reinforced with cap plates have shown that to ensure the negative moment $wl^2/18$. And constructing-deflection of deep decking shown that to satisfy the evaluation value (L/180 or 30mm).

Influence of red mud additive on lightening of artificial aggregates containing coal bottom ash (석탄바닥재가 포함된 인공골재의 경량화에 미치는 적니 영향)

  • Kang, Min-A;Kang, Seung-Gu
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.21 no.1
    • /
    • pp.41-46
    • /
    • 2011
  • The artificial aggregates (AAs) composing of 2 wastes, coal bottom ash and dredged soil (7 : 3, weight ratio) were fabricated as a function of red mud contents,0~30 wt% using direct sintering method at $1050{\sim}1250^{\circ}C$ for 10 min, and those physical properties were evaluated. Especially, in order to analyze the red mud addition effect on the bloating phenomenon of AAs manufactured, the specific gravity and water absorption were measured and studied linked with the microstructural observation results. The lightening of AAs was enhanced due to increased bloating with increasing temperature and red mud contents. The AAS sintered at $1050{\sim}1150^{\circ}C$ showed well-developed black-coring structure, but for the specimens containing red mud sintered over $1200^{\circ}C$ generated excessive liquid and gas caused by reduction of $Fe_2O_3$, thus the black-coring part was gradually burst open out of shell of AAs. Particularly, all specimens containing 30 wt% red mud was burst up when sintered over $1100^{\circ}C$. The AAs containing no red mud sintered at $1200^{\circ}C$ had a specific gravity of about 1.2 and those containing 20 wt% had below 1.0 which are characters of lightweight aggregate.

Investigation on the Hydrodynamic Behaviors of the Clarifier with an Interior Baffle in WWTP by using of Radiotracer $^{99m}Tc$ ($^{99m}Tc$ 추적자를 이용한 하수처리 시설 내 침전조의 정류벽 설치 유무에 따른 유체거동 변화측정)

  • Kim, Jin-Seop;Kim, Jong-Bum;Kim, Jae-Ho;Jung, Sung-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.3
    • /
    • pp.117-122
    • /
    • 2007
  • The hydrodynamic behaviors of the clarifier with an interior baffle in a wastewater treatment plant was investigated by using a radiotracer $^{99m}Tc$(30 40 mCi) to verify the results of CFD(computational fluid dynamics) modelling in the previous study. The clarifier model was manufactured with consideration to the hydraulic similarity(1/21) of a real plant($L{\times}W{\times}H:2.6{\times}0.4{\times}0.2m$). By installation of an interior baffle to the clarifier, the strong density current at the bottom of the clarifier decreased substantially and increased the area of sludge settling zone, which were visualized successfully from the radiotracer experiment. Also the portion of short circuit stream changed from 48 % to 32 % and the mean residence time of sludge decreased from 940 sec to 810 sec, which corresponds to the results of CFD modelling. As a result, it is anticipated that radiotracer technology can be used as an important tool for designing new wastewater treatment plants and verifying their performances after structural modifications.

The Strength and Applications of OSB Gusset Trusses for Field Assembly (현장조립용 OSB 덧댐판 트러스의 강도 및 활용방안)

  • Kim, Tae-Woo;Ha, Bin;Jang, Sang-Sik
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.6
    • /
    • pp.708-713
    • /
    • 2014
  • Trusses are widely used for wooden houses in the areas where wood construction in generalized for residential housings such as North America, Australian, New Zealand. In Korea, joist and rafter system is generally used because of the production cost, transportation cost and lack of experience required for truss manufacturing. In this study, roof trusses and flat trusses were manufactured by using oriented strand board (OSB) gusset plates for field assembly and tested under bending load to obtain the allowable loads. The allowable load and the actual load of 6m span roof trusses were 10.60 kN and 5.26 kN, respectively, which is regarded to be sufficient for use in construction. The allowable load and the actual load of 6m span floor flat trusses were 7.18 kN and 7.43 kN, respectively. For flat trusses, the allowable load is slightly lower than the actual load but the difference in very small, and it is thought that flat trusses can be used for construction by applying small change of structures and members.