• Title/Summary/Keyword: 밀봉(seal)

Search Result 80, Processing Time 0.025 seconds

Optimization of Pulsed Nd:YAG Laser Welding Conditions for Sealing of Lithium-ion Battery (리튬이온전지의 밀봉용접을 위한 펄스 Nd:YAG레이저 용접조건의 최적화)

  • Kim, Jong-Do;Yoo, Seung-Jo;Kim, Jang-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.5
    • /
    • pp.623-628
    • /
    • 2006
  • Laser material processing is a very fast advancing technology for various industrial applications. because of many advantages. Its major advantage of less and controlled heat input has been exploited successfully for the very critical application of aluminium alloy welding. This study suggested the occurrence source of weld-defects and its solution methods in a welding of lithium ion battery by pulsed Nd:YAG laser. In experiment. battery case has changed over joint geometry from welding of side position to flat one. In the case of a electrolyte injection hole in order to seal it. welding is carried out after pressing Al ball. At this time. an eccentric degree. contact length and gap are worked as a major parameters. As improving the method of Al ball pressing. it was able to reduce an eccentricity. increase the contact length and decrease gap. As a results of a experiment. a sound weld bead shape and crack-free weld bead can be obtained.

Optimization of Pulsed Nd:YAG Laser Welding Conditions for Sealing of Lithium-ion Battery (리튬이온전지의 밀봉용접을 위한 펄스 Nd:YAG레이저 용접조건의 최적화)

  • Kim, Jong-Do;Yoo, Seung-Jo
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.339-343
    • /
    • 2005
  • Laser material processing is a very fast growing technology for various industrial applications, because of many advantages. Its major advantage of less and controlled heat input has been exploited successfully for the very critical application of aluminium alloy welding. This study suggested the occurrence source of weld-defects and its solution methods in a welding of lithium ion battery by pulsed Nd:YAG laser. In experiment, battery case has changed over joint geometry from welding of side position to flat one. In case of a electrolyte injection hole in order to seal it, welding is carried out after pressing Al ball. At this time, an eccentric degree, contact length and gap are worked as a major parameters. As improving the method of Al ball pressing, it was able to reduce an eccentricity, increase the contact length and decrease gap. As a results of a experiment, a sound weld bead shape and crack-free weld bead can be obtained.

  • PDF

Studies on the Improvement of Packaging of Retorted Samgyetang (레토르트 삼계탕의 포장 개선을 위한 연구)

  • Lee, Jin-Hwan;Lee, Keun-Taik
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.15 no.2
    • /
    • pp.49-54
    • /
    • 2009
  • The effects of filling temperatures of broth and degassing method on the residual oxygen content and gas composition in the pouch and physical strength of packaging material for Samgyetang depending on the contamination of broth on the sealing layer and sterilization process were investigated. The residual oxygen content in the broth and the oxygen proportion in the headspace of package were decreased with the increase of broth temperature at filling into the pouch from 50 to 100. When the products were packaged as air-contained (Air), manually squeezed the upper side of package out to minimize the headspace (Degas) and flushed with nitrogen gas ($N_2$-Flushing) while maintaining the broth temperatures of Samgyetang at 50 or 85. The residual oxygen content and oxygen proportion were increased in the order of $N_2$-Flushing

  • PDF

A Study of in-vitro Performances of the Intracardiac Axial Flow Pump (심장내 이식형 축류 혈액펌프의 in-vitro특성에 관한 연구)

  • 김동욱;삼전부호희
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.1
    • /
    • pp.33-38
    • /
    • 1998
  • The intracardiac axial flow pump has been developed This device has several advantages: it fits well anatomically, its blood-contacting surface is small, and it is implanted as easily as an artificial heart valve replacement. The axial flow pump consists of an impeller and a motor, both of which are encased in a housing. Two types of impeller with 4 vanes and 6 vanes are used. Sealing of the motor shaft is achieved by means of a ferrofluidic seal. A flow of 5$\ell$/min was obtained at a differential pressure of 100mmHg with a motor speed of 7091rpm with the 4-vane impeller and 6402rpm with the 6-vane impeller. Sealing was kept against a pressure of 150mmHg at 7000rpm with the 4-vane impeller and 6402rpm with the 6-vane impeller. Sealing was kept against a pressure of 150mmHg at 7000rpm over 24 hours. The index of hemolysis was 0.056 with the 4-vane impeller and 0.214 with the 6-vane impeller. The intracardiac axial flow pump is a very promising circulatory support.

  • PDF

Thermocompression bonding for wafer level hermetic packaging of RF-MEMS devices (RF-MEMS 소자의 웨이퍼 레벨 밀봉 패키징을 위한 열압축 본딩)

  • Park, Gil-Soo;Seo, Sang-Won;Choi, Woo-Beom;Kim, Jin-Sang;Nahm, Sahn;Lee, Jong-Heun;Ju, Byeong-Kwon
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.58-64
    • /
    • 2006
  • In this study, we describe a low-temperature wafer-level thermocompression bonding using electroplated gold seal line and bonding pads by electroplating method for RF-MEMS devices. Silicon wafers, electroplated with gold (Au), were completely bonded at $320^{\circ}C$ for 30 min at a pressure of 2.5 MPa. The through-hole interconnection between the packaged devices and external terminal did not need metal filling process and was made by gold films deposited on the sidewall of the throughhole. This process was low-cost and short in duration. Helium leak rate, which is measured to evaluate the reliability of bonded wafers, was $2.7{\pm}0.614{\times}10^{-10}Pam^{3}/s$. The insertion loss of the CPW packaged was $-0.069{\sim}-0.085\;dB$. The difference of the insertion loss between the unpackaged and packaged CPW was less than -0.03. These values show very good RF characteristics of the packaging. Therefore, gold thermocompression bonding can be applied to high quality hermetic wafer level packaging of RF-MEMS devices.

Effect of Gas Composition in Polyethylene Film Bags on Storability of 'Fuyu' (Diospyros kaki Thunb.) Persimmon Fruit (PE Film 봉지 내 가스조성이 '부유(富有)' 단감의 저장성에 미치는 영향)

  • An, Ji-Hyun;Kang, Sung-Mo;Cho, Jeoung-Lai;Lim, Jong-Min
    • Horticultural Science & Technology
    • /
    • v.19 no.4
    • /
    • pp.550-554
    • /
    • 2001
  • 'Fuyu' persimmon fruits (Diospyros kaki Thunb.) were seal-packaged in $60{\mu}m$ polyethylene (PE) film bags with various $O_2$ and $CO_2$ combinations (0% $O_2$+5% $CO_2$, 2% $O_2$+5% $CO_2$, 2% $O_2$+8% $CO_2$, 5% $O_2$+5% $CO_2$, 5% $O_2$+10% $CO_2$), and in vacuum and air. They were then stored at $-0.5^{\circ}C$ for 95 days. Changes in fruit weight, firmness, soluble solids, Hunter L and a values, $CO_2$ concentrations, and marketability were investigated at 20-day intervals. A combination of 2% $O_2$ and 5% $CO_2$ as well as the vacuum treatment were effective in maintaining firmness, soluble solids, marketability, and Hunter a value of 'Fuyu' fruits. On the other hand, the treatment of 2% $O_2$ combined with 8% $CO_2$ and vacuum treatment were effective in maintaining fresh weight and Hunter L and a values. The highest marketable quality was maintained when the fruits were vacuum-sealed, although fruits softened severely in the area where two fruits contacted with each other.

  • PDF

Modified Atmosphere Storage of 'Shingo' Pears Packages with Polyethlene Film (폴리에틸렌 필름을 사용한 '신고'배의 Modified Atmosphere 저장)

  • Kim, Young-Myung;Han, Dae-Suk;Oh, Tae-Kwang;Park, Kwan-Hwa;Shin, Hyun-Kyung
    • Korean Journal of Food Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.130-136
    • /
    • 1986
  • 'Shingo' pears were seal-packaged in polyethylene (PE) film with different thickness of 0.04. 0.06, 0.07, and 0.08mm and stored for five months in an experimental storehouse with the temperature varyine 0 to $7^{\circ}C$ and relative humidity varying 86 to 89%. The atmosphere in PE film bags was modified to 5-l4% oxygen with 3-5% carbon dioxide depending on the film thickness and the storage period. Packaging of pears with PE film effectively reduced the weight loss, which resulted in good appearance after 5 months' storage, while non-packaged pears showed a slight wilt. Decay occurrence was not significantly different among the treatments. but role browning occurred a little more in packaged lots than in non-packaged lot. The sensory panel rated the pears front 0.07mm-thick bag highest in flavor, texture, and juiciness, which might be due to the high sugar content and low titratable acidity. The firmness of pear flesh decreased with the stogare time and its change was found to be highly correlated with that of cellulase activity (correlation coefficient= -0.946). Thisresult indicated that cellulase might be one of the enzymes responsible for the softening of pear fruit during storage.

  • PDF

Perforation Adjustment of Unit Package for 'Fuji' Apples during Short-term Cold Storage and Export Simulation ('후지' 사과의 단기 저온저장 및 모의수출 과정에서 소포장의 천공도 조절 효과)

  • Kim, Su-Jeong;Park, Youn-Moon;Yoon, Tae-Myung
    • Horticultural Science & Technology
    • /
    • v.32 no.2
    • /
    • pp.184-192
    • /
    • 2014
  • Various types of unit packaging methods were applied for 'Fuji' apples during short-term cold storage and export simulation. Gas tightness of the package was controlled stepwise in the successive two-year experiments using different perforation treatments (none, punch hole, or pinhole) and sealing methods (tie v s. heat seal). Risk of tight packaging and effectiveness of macroperforation on weight loss and quality maintenance were analyzed as related to changes in gas concentration inside the packages. Immediately after harvest, each 5 apple units were packaged in $40{\mu}m$ polypropylene (PP) film bags, stored 4 weeks at $0^{\circ}C$, and then put on the shelf for one week at ambient temperature in the preliminary experiment, In the main experiment, export process was imposed after storage simulating 2 week refrigerated container shipment at $0^{\circ}C$ plus one week local marketing at ambient temperature. Non-perforated film packaging with relatively high gas tightness induced flesh browning caused by carbon dioxide accumulation regardless of the sealing methods. Among perforated film packaging, in contrast, atmospheric modification was partly established only in the pinhole treatment and flesh browning symptom was not observed in all the treatments. Even the punch hole perforated film packaging without gas tightness effectively reduced the weight loss, whereas had slight benefits for quality maintenance. Reduced perforation using pinhole treatment seemed to improve sensory texture, while effects on physicochemical quality were insignificant. Overall results suggest the need of more minute perforation treatments on the packaging film to ensure modified atmosphere effects on quality maintenance.

Sensory Evaluation and Changes in Physicochemical Properties of Gochujang Powder with Different Drying Methods (건조방법에 따른 분말 고추장의 성분변화와 관능적 특성)

  • Kim Cheong-Gyu;Lee Jung-Suk;Oh Kyung-Keun;Yi Sang-Duk;Oh Man-Jin
    • Food Science and Preservation
    • /
    • v.13 no.1
    • /
    • pp.24-29
    • /
    • 2006
  • This study was carried out to promote aspects of preservation and convenience of red pepper paste (r.p.p.). Sample was prepared with spray drying (s.d), vacuum drying (v.d) and freeze drying (f.d) methods. The prepared powdered samples were stored for 90 days at $35^{\circ}C$ in seal condition. After powdered samples were hydrated, the samples were used for analysis such as a sensory test, texture, color and changes of component According to sensory test, quality of dried red pepper paste were better in order to f.d.r.p.p. < s.d.r.p.p. < v.d.r.p.p. Changes of pH, reducing sugar, amino nitrogen and NaCl of dried r.p.p. were not observed compared to control but viscosity decreased by about $15\%$ During the storage, acidity decreased by about $15\%$ and reducing sugar, amino nitrogen and ethanol decreased slightly. Hunter L, a and b values decreased from 24.8-27.3 to 23.6-24.4, from 10.8-12.0 to 8.3-9.3 and from 7.1-7.9 to 4.4-5.5, respectively.

Tightness of specimen sealing box in 20 L test chamber to evaluate building materials emitting pollutants (건축자재에서 방출되는 오염물질 평가 시 사용되는 20 L 시험챔버 시편홀더의 기밀성 개선)

  • Shin, Woo Jin;Lee, Chul Won;Kim, Man Goo
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.261-267
    • /
    • 2007
  • The 20 L small chamber test method is to evaluate pollutants such as TVOC, formaldehyde emitted from building materials. This method was only designed to evaluate the surface emission of sample exposed in the chamber. In this method, building materials cut with a fixed standard size are fixed in a sample sealing box. The sample sealing box is put into the 20 L test chamber. This chamber is ventilated at a standard air change rate with purified air for 7 days then the sample from the chamber is collected and analyzed to measure the emission rate of TVOC and formaldehyde. In this method, however, if the sealing box does not guarantee airtightness, accurate evaluation for the building materials can not be achieved due to the pollutants emitted from edge of the sample so called, edge effect. This edge effect can be much greater when evaluating panels such as plywood, flooring due to their surface treatment. In this study, flooring was tested to check airtightness of the sample sealing box with analytic results between 1L and 20 L test chamber. Furniture materials like LPM coated one side surface treatment and MDF coated both sides surface treatment with LPM were tested to identify whether the improvement of the sample sealing box airtightness is possible with the comparison between existing and improved test method that low VOC emission tape was used to seal the sample edge. After 7 days, MDF TVOC emission rate was different according to the existence and nonexistence of tape. The emission rate of the existing test method was $0.009mg/m^2h$ and that of improved test method was $0.003mg/m^2h$. Relative standard deviation for the existing test method was $0.004mg/m^2h$ and relative standard deviation for the improved test method was $0.002mg/m^2h$ when the same sample was analyzed three times. The improved test method in this study using low VOC emission tape was effective and able to reduce the heterogeneous effect of the edge from the sample sealing box.