Comparison of Smart Phone Application Based Hearing Screening and Hearing Handicap Inventory (스마트 폰 애플리케이션 기반 청각선별과 설문 청각선별의 비교)

  • Heo, Seung-Deok;Park, Chan-Ho;Song, Byung-Seop
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.1
    • /
    • pp.73-79
    • /
    • 2017
  • It is difficult to detect the adult hearing loss after the language acquisition because of its slow progression, which can be evaluated voluntarily and actively when the appropriate tools are provided. Smartphones are one of useful tools, and they can utilize surveys and/or applications for hearing screening. This study aims to verify the possibility as a tool discovering delayed acquired hearing losses by comparing the pure tone screening application (app_PTS) which was recently developed by our research team and hearing handciap inventory (HHI). The subjects were 22 people whose age ranges from 10s to 80s. For pure tone averages (PTAs), hearing threshold level was selected the best one in same frequency, in both ears. Sensitivity and specificity of HHI were confirmed based on self awareness of hearing loss and PTAs at 1, 2, 4 kHz. Comparisons of two tests were measured by analyzing simple regression of correlation between PTAs of App_PTS and HHI scores. Sensitivity and specificity were 1.000 in both criteria. There was a statistically significant relationship between the PTAs_4 kHz and HHI (R-square = .951, p = .000). Hearing screening by questionnaire showed high correlation with smart phones based on application. Therefore, it can be useful as a hearing screening tool for individual life cycle using an user-friendly tool.

Complementarity between SDQ-SR and MMPI-A in Assessing Adolescents with Internalizing Disorder : A Preliminary Study (내재화장애 청소년의 평가에서 자기보고용 강점난점척도와 MMPI-A의 상호보완성 : 예비연구)

  • Shin, Kyo Jung;Ahn, Joung Sook;Lim, Jee Young;Lee, Jin Hee
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.26 no.1
    • /
    • pp.9-18
    • /
    • 2018
  • Objectives : The aims of this study were to investigate the psychopathology in adolescents with internalizing disorder using the self-report version of Strengths and Difficulties Questionnaire (SDQ-SR) and the Minnesota Multiphasic Personality Inventory for adolescents (MMPI-A), and to explore the complementarity between these two inventories for diagnostic assessment. Methods : Ninety-one patients aged 13-17 were divided into two groups by clinical diagnosis, 44 with internalizing disorder and 47 comparison group with other disorders. The data of SDQ-SR and MMPI-A completed by them were analyzed for the ability to predict internalizing disorder. Results : The logistic regression analysis revealed that diagnostic predictability increased by 2.27 times with every 1 point of SDQ-SR emotional symptom score increment. Comparison of ROC curves for internalizing disorders showed that the SE and SP of SDQ-SR emotional symptom with score over 4 was 88.94 and 78.72, respectively. For A-anx of MMPI-A with score over 56, SE and SP was 77.27 and 74.47, respectively. However, combination of these scales could not enhance the predictability of diagnostic classification more than that of SDQ-SR emotional symptom alone. Conclusions : Emotional symptom scale of SDQ-SR and A-anx, A-aln, A and INTR of MMPI-A should be important subscales for diagnosing the internalizing disorder of adolescents, however, which needs to be examined further with a larger sample size including normal control group.

Usefulness of Automated PCR Test for the Detection of Mycobacterium Tuberculosis in Fresh Biopsy Tissues (신선조직 검체에서 결핵균 검출을 위한 자동화 중합효소연쇄반응 검사의 유용성)

  • Choi, Woo Soon;Shin, So Young;Kim, Jong Ok;Kim, Myung Sook;Lee, Hye Kyung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.1
    • /
    • pp.54-59
    • /
    • 2006
  • Background: Although there have been several studies regarding the clinical value of an automated TB-PCR study using sputum, bronchial washing, and other body fluid samples for the detection of pulmonary tuberculosis, there are only a few reports on the use of fresh tissue samples. Materials and methods: The acid-fast bacilli stain(AFB), tuberculosis culture, automated TB-PCR study, and histopathology examination were performed in 42 fresh tissue samples. Results: Among the 42 cases, 18 cases were diagnosed with tuberculosis based on the clinical findings. Sixteen of the 18 cases were TB-PCR positive and of these 16 cases, only 2 cases were positive in the AFB stain or culture study. However, all 18 cases showed the histopathology findings of chronic granulomatous inflammation that was compatible with tuberculosis. Based on the clinical findings, the sensitivity, specificity, positive predictability, and negative predictability of the automated TB-PCR study were 88.9%, 100%, 100%, and 92.3% respectively. Conclusion: An automated TB-PCR assay is an important diagnostic tool for diagnosing tuberculosis in fresh tissue samples.

Evaluation of Diagnostic Performance of a Polymerase Chain Reaction for Detection of Canine Dirofilaria immitis (개 심장사상충을 진단하기 위한 중합연쇄반응검사 (PCR)의 진단적 특성 평가)

  • Pak, Son-Il;Kim, Doo
    • Journal of Veterinary Clinics
    • /
    • v.24 no.2
    • /
    • pp.77-81
    • /
    • 2007
  • Diagnostic performance of polymerase chain reaction (PCR) for detecting Dirofilaria immitis in dogs was evaluated when no gold standard test was employed. An enzyme-linked immunosorbent assay test kit (SnapTM, IDEXX, USA) with unknown parameters was also employed. The sensitivity and specificity of the PCR from two-population model were estimated by using both maximum likelihood using expectation-maximization (EM) algorithm and Bayesian method, assuming conditional independence between the two tests. A total of 266 samples, 133 samples in each trial, were randomly retrieved from the heartworm database records during the year 2002-2004 in a university animal hospital. These data originated from the test results of military dogs which were brought for routine medical check-up or testing for heartworm infection. When combined 2 trials, sensitivity and specificity of the PCR was 96.4-96.7% and 97.6-98.8% in EM and 94.4-94.8% and 97.1-98% in Bayesian. There were no statistical differences between estimates. This finding indicates that the PCR assay could be useful screening tool for detecting heartworm antigen in dogs. This study was provided further evidences that Bayesian approach is an alternative approach to draw better inference about the performance of a new diagnostic test in case when either gold test is not available.

Evaluation on Medical Application of Survey meters in Convergence Perspective for the Efficient Disaster Responses in the Massive Radiological Disasters: A Simulation Study of Externally Contaminated Patients Using Two Representative type of Survey-Meters (융합적 관점에서 본 대량방사선 재난에서 효율적 재난반응을 위한 오염감시기의 의학적 적용에 대한 평가: 대표적 두가지 오염감시기를 이용한 방사선외부오염환자 시뮬레이션 연구)

  • Kim, Chu Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.3
    • /
    • pp.77-83
    • /
    • 2021
  • The purpose of the study is to evaluate the effect on medical application and convergence for the efficient disaster responses in the massive radiological events by comparison of two types of survey-meters(hand held survey-meter and transportable portal monitor). In the simulated radiation disaster drill, twelve participants randomly wore a personal protective equipments (PPE) with twelve check source. We measured participants to detect five real radioactive sources of the twelve check sources, using two types of survey meters. The primary outcome was the measuring time. The secondary outcome was the sensitivity and specificity of the detection of the real radioactive source. The average time by the hand held survey meter was 231.9 ± 116.6 seconds, and the time by transportable portal monitor was statistically shorter 8.690 ± 1.667 seconds. There was no difference in the sensitivity and specificity between two survey meters. The transportable portal monitor survey meter was considered to have medical application and play an important role in radiological disasters.

Preservation through Cloning of Superior Canine Scent Detection Ability for Cancer Screening (복제를 통한 우수한 암탐지 능력의 보존)

  • Kim, Min-Jung;Park, Jung-Eun;Oh, Hyun-Ju;Hong, So-Gun;Kang, Jung-Taek;Rhim, Sang-Hyun;Lee, Dong-Won;Ra, Jung-Chan;Lee, yeong-Chun
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.352-355
    • /
    • 2015
  • This study was conducted to ascertain whether the scent detection ability of a donor dog having extraordinary talent in cancer detection can be conserved through cloning. A specially trained dog for colorectal cancer detection was cloned, and she was trained and tested to detect breast cancers using breath samples collected from patients and healthy volunteers. Scent detection sensitivity of the clone was 93.3% and specificity was 99.5%, similar with those of donor (91% and 99%). Furthermore, the clone successfully detected early stage of breast cancers. Therefore, superior canine scent detection ability for cancer screening could be preserved through cloning.

Development and validation of a PCR method to discriminate between Branchiostegus japonicus and Branchiostegus albus (옥돔과 옥두어 판별을 위한 PCR 검사법 개발과 검증)

  • Kim, Na-Ye-Seul;Yang, Ji-Young;Kim, Jung-Beom
    • Korean Journal of Food Science and Technology
    • /
    • v.51 no.3
    • /
    • pp.295-299
    • /
    • 2019
  • We developed and validated species-specific primers for Branchiostegus japonicus and Branchiostegus albus to prevent the sale of B. albus as B. japonicus. Primers for B. japonicus and B. albus were designed against the cytochrome b gene. Multiplex PCR showed a 288 bp amplicon for B. japonicus, a 159 bp amplicon for B. albus, and a 502 bp amplicon for the internal control. The PCR product bands for B. japonicus, B. albus, and the internal control were present at 1 ng each. The specificity and sensitivity of the primers developed in this study were validated by testing 38 B. japonicus strains and 13 B. albus strains. Using this monitoring method, fake fish did not appear due to the agreement between the experimental results and the species. Therefore, the developed multiplex PCR method was suitable for differentiating B. japonicus and B. albus.

Comparison of $^{18}F$ FDG-PET and CT/MRI for the Diagnosis of Cervical Lymph Node Metastasis in Head and Neck Cancer: A Level-by-Level Based Study (두경부암 환자에서 경부 림프절 전이에 대한 $^{18}F$ FDG-PET과 CT/MRI의 진단적 정확도 비교: 림프절군에 따른 연구)

  • Yang, Yoo-Jung;Kim, Jae-Seung;Kim, Sang-Yun;Lee, Ho-Gyu;Nam, Soon-Yul;Choi, Seung-Ho;Ryu, Jin-Sook;Yeo, Jeong-Seok;Moon, Dae-Hyuk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.1
    • /
    • pp.52-61
    • /
    • 2004
  • Purpose: Cervical lymph node metastasis is the most important factor of the prognosis and therapeutic planning in head and neck cancer. With increasing interest of minimally invasive neck surgery, more accurate preoperative assessment of cervical lymph node becomes more essential. We evaluated the diagnostic accuracy of $^{18}F$ FDG-PET in the assessment of lymph node metastasis in patients with primary head and neck cancer and compared the results with those of CT/MRI. Materials and Methods: Thirty-two patients (M/F=27/5, $56{\pm}10yr$) with biopsy proven head and neck cancer (16 supraglottic cancer, 9 tongue cancer, 7 others) underwent FDG-PET and CT/MRI (25/7) within 1 month before neck dissection. Based on lymph node level, the diagnostic sensitivity and specificity of FDG PET and CT/MRI for the metastasis of cervical lymph node were compared. Results: Of 153 lymph node levels dissected in 32 patients, 32 lymph node levels of 19 patients were positive for metastasis by histopatholologic examination. The overall sensitivity and specificity of FDG-PET were 88% (28/32) and 93% (113/121), whereas those of CT/MRI were 56% (18/32) (p=0.002) and 92% (112/121), respectively. The diagnostic sensitivity and specificity of FDG-PET were different according to location of lymph node levels, and those of ipsilateral level 11 were lower than those of other levels. Conclusion: FDG-PET is more sensitive in detecting metastatic cervical lymph node in head and neck cancer than CT/MRI. FDG-PET might be useful in guiding the extent of neck dissection.

Validity of the New Caries Activity Test using Real-Time Polymerase Chain Reaction (실시간 중합효소연쇄반응 방법을 이용한 새로운 치아우식 활성 검사법의 유효성)

  • Kwon, Doyoun;Kim, Heejin;Nam, Okhyung;Kim, Misun;Choi, Sungchul;Kim, Kwangchul;Lee, Hyoseol
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.3
    • /
    • pp.354-362
    • /
    • 2018
  • Periogen is a new caries activity test using real-time polymerase chain reaction. The aim of this study was to assess the validity of Periogen by evaluating the correlation with dmft, dmfts indices and comparing with Cariview and caries risk assessment tool (CAT). 83 children under 6 participated in this study. Dmft, dmfts indices and CAT were collected through an examination of oral health status. Plaque samples for Periogen and Cariview were collected and manipulated according to the manufactures' instructions. The correlation coefficient of Periogen, Cariview and CAT with the dmfts index were 0.38, 0.56 and 0.66 in each (p < 0.01). The sensitivity of Periogen, Cariview and CAT were 43%, 76% and 95% and specificity were 80%, 72% and 74% respectively. Area under curve under the receiver operating characteristic curves in each method indicated 0.69, 0.81 and 0.85. CAT and Cariview were more effective in evaluation the risk of dental caries than Periogen so far. To be used Periogen clinically, more improvements for higher validity were needed.

Single step purification of potent antigenic protein from sparganum by gelatin-affinity chromatography (젤라틴 친화성 크로마토그래피를 이용한 스파르가눔 성분단백질의 순수분리)

  • Yoon Kong;Shin-Yong Kang;Seung-Yull Cho
    • Parasites, Hosts and Diseases
    • /
    • v.29 no.1
    • /
    • pp.1-8
    • /
    • 1991
  • Out of many component proteins in crude saline extract of Spirometra mansoni plerocercoid (sparganum) , 36 kDa and 29 kDa proteins were found to be the most antigenic and were already purified by immunoaffinity chromatography using monoclonal antibody as a ligand. In this study, a single step purification of these potent antigenic proteins of sparganum extract was investigated. When the crude saline extract was charged to gelatin-Sepharose 4B affinity column, 36 kDa and 29 kDa protein fractions were bound. SDS-polyacrylamide gel electrophoresis (PAGE) and SDS-PAGE/immunoblot confirmed that the bound protein to gelatin was serologically pure. When evaluated by ELISA with patients sera, the purified protein of 36 and 29 kDa also showed improved antigenicity.

  • PDF