A Study on the Regeneration of SCR Catalyst Deactivated by Unburned Carbon Deposition (탄소침적으로 피독된 탈질 촉매의 재생에 관한 연구)

  • Moon, Seung-Hyun;Lee, Seung-Jae;Ryu, In-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.10
    • /
    • pp.928-935
    • /
    • 2010
  • A bag filter system was partially burnt down during a trial run of waste wood incineration boiler. This brought about unburned hydrocarbon which caused a rapid deactivation of low temperature SCR catalyst set up in two stage after the bag filter. The deactivated catalyst was investigated in order to trace the origin by several characterization methods such as XRD, EDX, BET, TGA, SEM. The deactivated catalyst was regenerated by different methods such as acid washing, water washing in ultrasonication, and calcination treatment under air condition. It is found the calcination treatment under air condition at $450^{\circ}C$ for 2 hours to be the best regeneration method. The catalytic activity was measured in the form of 2 cm ${\times}$ 2 cm ${\times}$ 10 cm (catalyst weight 10 g) honeycomb type. A deNOx efficiency of the regenerated catalyst showed 100% at $180^{\circ}C$ which is the same level of fresh one.

Performance of Low NOx Coal Burner in Industrial Coal Fired Boiler (산업용 보일러에 적용된 저 NOx 미분탄버너의 연소성능 평가)

  • Kim, Sang-Hyeun;Kim, Hyuk-Je;Kim, Hyeuk-Pill;Song, Si-Hong;Lee, Ik-Hyung
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1751-1755
    • /
    • 2004
  • Increasing environmental pressures to reduce NOx emission are being placed on coal-fired boilers. To meet the environmental requirements, Doosan Heavy Industries & Construction Co., Ltd.(Doosan) has developed low NOx pulverized coal burner. Low NOx pulverized coal burner has already delivered, and it's combustion performance was evaluated to the NOx and Unburned Carbon(UBC) during the commissioning tests. The test results are shown that the strong relationship is existed between NOx and OFA flow rate, and also fuel-N fraction of coal has effected on NOx emission.

  • PDF

A Study on the Flame Monitoring System Development (화염감시 시스템 개발에 관한 연구)

  • 백운보;황이철;이승종
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.2
    • /
    • pp.60-66
    • /
    • 2004
  • Increased energy costs have placed demands for improved combustion efficiency, high equipment availability, low maintenance and safe operation. Simultaneously low NOx modification, installed due to stricter environmental legislations, require very careful combustion management. The flame diagnostics system has been developed specially to meet these requirements. We aimed at gaining the relationship between burner flame image and emissions such as NOx and unburned carbon in furnace by utilizing the image processing method. For the first step of development, its possibility test was undertaken with bench furnace. The test proceeded to the second step with pilot furnace, the system was observed to be effective for evaluating the combustion conditions.

정전선별법을 이용한 석탄회로부터 미연탄소분 제거에 관한 연구

  • 최우진;염영길
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.97-105
    • /
    • 1998
  • The goal of this study is to investigate the potential application of triboelectrostatic separation process for removing unburned carbon from fly ash. The process utilizes the difference in electrical charging characteristics between the organic material (carbon) and the mineral matter (fly ash). In the present work, dry separation tests have been conducted on Samchunpo fly ash samples using a bench - scale analytic separator. The test variables studied include air rate, feed rate, electric field strength, particle size, charger material and length, etc. The best separation results were obtained at the air rate 501/min, feed rate 15 g/min and voltage 15 ㎸. The fly ash with carbon content below 1 % was obtained with over 65% recovery.

  • PDF

Flame Image Analysis Systems for Combustion Conditions Monitoring (연소상태 감시용 화염 영상분석 시스템)

  • 백운보;한성현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.499-502
    • /
    • 2003
  • Increase energy costs have placed demands for improved combustion efficiency, high equipment availability, low maintenance and safe operation. Simultaneously low NOx modification, installed due to stricter environmental legislation, require very careful combustion management. We aimed at gaining the relationship between burner flame image and emissions such as NOx and unburned carbon in furnace by utilizing the image processing method. For the first step of development, its possibility test was undertaken with bench furnace. The test proceeded to the second step with pilot furnace, the system was observed to be effective for evaluating the combustion conditions. By using this technology, it is possible to perform continuous monitoring of the combustion conditions and instant detection of individual changes for each burner to prevent future loss of ignition.

  • PDF

An Experimental Study on the Quality of High Flowing Concrete according to Ignition Loss of Fly-ash (플라이애쉬의 미연탄소 함유량에 따른 고유동콘크리트의 품질에 관한 실험적 연구)

  • 신흥철;강희관;최세진;김규용;김진만;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.381-384
    • /
    • 1997
  • It is necessary for manufacturing the high flowing to use the fly-ash as binder of concrete, therefore, Quality of fly-ash is very important to the fluidity of high flowing concrete. In this study, it is comparing and investigating the fludity of high flowing concrete used some fly-ash which it's Ignition loss is 2.44, 4.90, 7.10%. As a result of this experimental study, Ignition loss of fly-ash effects the properties of high flowing concrete, such as air content, flowability, passability etc. but even if valve of ignition loss is upper the specification, properties of high flowing concrete such as setting and hardening time, compressive strength etc.

  • PDF

Effects of Carbon Content and Fineness of Fly Ash on Properties of Concrete (플라이애쉬의 미연탄소량 및 분말도가 콘크리트의 성질에 미치는 영향)

  • Kim, Hoo;Park, Yon-Dong;Shon, Myung-Soo;Kim, Ho-Young;Lee, Bok-Gi
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.174-179
    • /
    • 1997
  • In this study, effects of carbon content and fineness of fly-ash on the workability an the strength development of concrete and investigated experimentally. Carbon content with 6 levels (0, 2, 3, 4, 5, 7%) and fineness with 3 levels (4, 000, 5, 000, 6, 000 $\textrm{cm}^2$/g) are selected for test variables. Besides, the effect of fly-ash with variation of initial concrete temperature is tested. To measure slump and air losses, small laboratory agitator is used. As the results, the used AE admixture content to maintain constant initial air content is increased linearly with increasing carbon content in fly-ash. With increasing fineness of fly-ash, the strengths at 3 and 7 days are slightly increased, however, there is no clear difference among 28 day strengths within the scope of this study.

  • PDF

Effect on the Corrosion of Steel by Unburnt Carbon in Fly Ash Cement Mortar (미연탄소분이 플라이 애시 시멘트 모르타르 내 철근의 부식에 미치는 영향)

  • Ha, Tae-Hyun;Bae, Jeong-Hyo;Kim, Dae-Kyeong;Lee, Hyun-Goo;Ha, Yoon-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.2
    • /
    • pp.338-342
    • /
    • 2007
  • The increase of activated carbon contents in fly ashes accelerate the corrosion of steel embedded in ordinary portland cement(OPC) mortar. Cement losses its identity of colour when the % of carbon is increased. More than 60[%] area was rusted when carbon content is increased beyond 8[%] for the exposure period of one year. Comparable corrosion rate with OPC was obtained up to 6[%] carbon level only. The tolerable limit of replacement for various admixed carbon system under aggressive alternate wetting and drying condition with 3[%] NaCl was found to be 6 to 8[%].

The Misfire Detection by the Exhaust Pressure Ascent Rate (배기 압력 상승률에 의한 실화 검출)

  • 김세웅;최미호;심국상
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.2
    • /
    • pp.1-7
    • /
    • 2003
  • This paper proposes a method to detect misfired cylinders by the exhaust pressure ascent rate. The misfire is generated by faults of electric system or faults of fuel delivery system. It is one of the abnormal combustions. Therefore, it increases the unburned hydrocarbon and the carbon monoxide and affects a bad influence to the 3-way catalyst. The misfire causes to decrease the power of the engine and increase the consumption of the fuel. Early detection and correction of the misfired cylinders can prevent these unusual phenomena. The misfired cylinders can be detected by the comparison of exhaust pressure ascent rate during each cycle. The exhaust pressure ascent rate is defined as pressure rise per time. Our experimental results showed that the proposed method is effective in the detection of the misfired cylinders on a gasoline engine regardless loads and revolutions of the engine.

Hydration Properties of Cement Matrix using Surface Treatment Blast Furnace Slag by Arc Discharge (아크방전에 의해 표면개질 된 고로슬래그를 사용한 시멘트 경화체의 수화 특성)

  • Kim, Sun-A;Kim, Hyeon-Sung;Park, Sun-Gyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.91-92
    • /
    • 2018
  • A glassy thin film was formed on the surface of the blast furnace slag. When blast furnace slag is used as an admixture of concrete, addition of alkali activators were required. However, alkali activators are not only dangerous as chemical products, but they are also difficult to use as expensive materials. Therefore, it is necessary to study the way of removal of the glassy thin film of blast furnace slag without the risk and cost increase. In this study, to solve this problem, experiment was carried out to improve the hydration reactivity by treatment the surface of blast furnace slag using arc discharge. Experimental results show that when the surface of the blast furnace slag was tratmented by arc discharge, the glassy thin film was destroyed. And the hydration reactivity was improved, the compressive strength was increased.

  • PDF