• Title/Summary/Keyword: 미세 누출

Search Result 243, Processing Time 0.036 seconds

Comparison of microleakage after load cycling for nanofilled composite resin fillings with or without flowable resin lining (Nanofilled 복합레진으로 와동 충전 시 flowable 레진 사용 유무에 따른 피로시험 후의 미세 변연 누출 비교)

  • Han, Sun-Deok;Kim, Won;Choi, Ji-Young;Oh, Nam-Sik;Lee, Myung-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.342-347
    • /
    • 2009
  • Statement of problem: when using resin for class II restoration, micoleakage by instrumentation can be regarded as the primary negative characteristic. A review of the available literature suggests that using flowable resin as liner to decreased microleakage. Purpose: The aim of this study was to determine the influence of the nanofilled flowable resin lining on marginal microleakage after load cycling in class II composite restoration fillings using nanofiller resin. Material and methods: 24 extracted premolars were prepared with class II cavity. F group was restored the nanofilled resin with the nanofilled flowable resin as liner. NF group was restored the nanofilled resin only. After restoration, an experiment was performed on 2 groups using a 300N load at 104, 105 and 106 cycles. Prior to and before each load cycling, it was gauged length on total marginal microleakage, axial marginal microleakage and buccal, gingival, lingual marginal microleakage. Data were analyzed with the Mann-Whitney test & Kruskal-Wallis test. Results: There were statistically significant differences between 2 groups and between individual groups. (P <.05) The result showed less microleakage in teeth restored by the nanofilled resin, which was lined by the nanofilled flowable resin. Conclusion: There was significant reduction in microleakage when the nanofilled flowable resin lining was placed underneath the nanofilled resin in class II composite restoration fillings.

EFFECT OF RESIN SEALANTS ON THE REDUCTION OF MICROLEAKAGE IN COMPOSITE RESTORATIONS (복합레진 수복물의 미세누출 감소를 위한 레진 전색제의 효과)

  • Cho Young-Gon;Kim Mun-Hong;Lee Myung-Goo
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.4
    • /
    • pp.282-289
    • /
    • 2006
  • The purpose of this study was to compare the ability of three resin surface sealants to prevent microleakage in Class V composite resin restorations. Forty Class V cavities with the occlusal margin in enamel and gingival margin in dentin were prepared on the buccal surfaces of sound extracted molars, and restored with composite resin. Restorations were randomly assigned into one of four equal groups (n = 10): a control group, without resin sealing, and three experimental groups in which margins were sealed with Fortify Plus, Biscover and Permaseal, respectively. Specimens were thermocycled, immersed in a 2% methylene blue solution for 4 hours, sectioned longitudinally, and observed the leakage at the occlusal and gingival margins. The result was analyzed using Kruskal-Wallis test, Mann-Whitney test and Wilcoxon signed rank test. In conclusion, the ability to reduce microleakage at occlusal margins was similar in all of three sealants. However at gingival margin, it depended on the type of used resin surface sealant. At gingival margin. control and Fortify Plus group showed statistically higher microleakage than PermaSeal group. and Fortify Plus group also showed higher microleakage than BisCover group (p < 0.05).

EFFECT OF BISCOVER ON THE MARGINAL MICROLEAKAGE OF COMPOSITE RESIN RESTORATION (복합레진 수복물의 변연 미세누출에 관한 BiscoverTM 전색제의 효과)

  • Cho, Young-Gon;Choi, Hee-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.5
    • /
    • pp.355-362
    • /
    • 2005
  • The purpose of this study was to compare the effect on marginal leakage of a resin surface sealant (Biscover) applied before or after polymerization of composite resin to unsealed composite restorations. Thirty Class V cavities with the occlusal margin in enamel and cervical margin in dentin or cementum were prepared on the buccal surfaces of sound extracted molars and restored with a microfilled light-cured composite resin (Micronew). Restorations were randomly assigned into one of three equal groups (n = 10): a control group - no surface sealing, group 1 - applied Biscover after polymerization of the composite resin. and group 2 - applied Biscover before polymerization of the composite resin. Specimens were thermocycled, immersed in a $20\%$ methylene blue solution for 4 hoots, sectioned longitudinally, and analyzed for leakage at the occlusal and gingival margins. The results of this study were as follows 1. In sealed group, group 2 showed higher microleakage than group 1 at both occlusal and gingival margins. but there was no significant difference between two groups (p > 0.05). 2. Unsealed control group showed a little higher microleakage than sealed group at occlusal margins, and a little Higher or similar microleakage than sealed group at gingival margins (p > 0.05) 3. Control group and group 2 showed significantly less microleakage at the occlusal margins, but group 1 showed no significantly difference between microleakage at the occlusal and gingival margins.

Microleakage of class II posterior composite resin filling using various light curing methods (구치부 광중합 복합레진 수복시 여러 광조사 방법에 따른 미세변연누출에 관한 연구)

  • Jong-Uk Par;Byeong-Hoon Cho;Ho-Hyun Son;Chung-Moon Um;Hyuk-Choon Kwon
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.4
    • /
    • pp.326-331
    • /
    • 2001
  • 목적 - 최근 복합레진의 미세변연누출을 줄이기 위한 새로운 광중합 조사방법이 연구되고 있다. 또한 구치용 복합레진이 개발되면서 그 제조회사에서는 5mm 깊이까지 광중합이 가능하다고 소개하고 있다. 본 연구에서는 논리적 가설에 근거한 몇가지 광중합 조사방법이 구치부 class II 와동의 복합레진 충전시 미세변연누출에 어떠한 영향을 미치는지를 관찰하였다. 재료 및 방법 - 100개의 우식증이 없는 사람의 상하악 대구치를 사용했다. 각 치아에 교합-치은방향으로 4mm, 협설 4mm, 깊이 2mm의 class II 와동을 형성하여 인접치와 함께 베이스플레이트 왁스에 매몰하고 구치용 복합레진인 Surefil을 제조 회사의 지시대로 충전하였다. 이때 5가지의 광조사방법을 이용하여 5개의 군으로 나누어 중합하였다(Table 1). 수복된 치아들을 5$^{\circ}C$와 55$^{\circ}C$의 수조에서 번갈아 1분씩 총 500회의 온도변화를 주어 thermocycling을 실시한 후 근첨을 폐쇄하고 수복와동의 치은경계를 제외한 전 표면에 nail varnish를 2회 도포하였다. 2%의 methylene blue용액에 24시간 침적시키고 흐르는 물에 세척한 후 시편을 투명한 에폭시 레진에 매몰하였다. 매몰된 시편을 치아 장축에 평행하게 절단 연마하였다. 입체 현미경으로 미세변연누출을 관찰하고 Kruskal-Wallis One Way ANOVA 와 Dunn's Method로 통계처리 하였다. 결과 - 1. 미세누출은 1군, 4군과 5군, 2군 3군 순으로 증가였다. 이때 1군, 4군과 5군은 통계적 유의성이 없었다(P>0.05). 2. 2군의 경우 1군, 4군, 5군에 비교하여 유의성 있게 미세누출이 많았으며(P<0.05) 3군에 비하여 유의성 있게 적게 나타났다(P<0.05). 3. 3군의 경우 다른 방법들에 비교하여 통계적으로 유의성 있게 미세누출이 많았다(P<0.05).

  • PDF

Microleakage at the cervical margin of Class II composite restorations with different intermediate layer treatments (치경부변연에서 중간층 수복이 구치부 2급 복합레진의 미세누출에 미치는 영향에 관한 연구)

  • Kim, Ki-Ok
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.6
    • /
    • pp.467-474
    • /
    • 2003
  • 복합레진에 의한 구치부 2급 와동의 수복에서 치은부 변연이 법랑-백아 경계 하방에 위치하는 경우 복합레진의 중합 수축에 의한 응력은 변연부의 폐쇄능력을 저하시키고 이로인한 미세누출은 2차적인 우식이나 술후과민증을 일으켜 임상에서의 성공을 위협한다. 본 연구에서는 2급 와동에서 복합레진으로 수복하기 전에 치은 변연부를 중합수축에 의한 응력을 완화시킬 수 있는 것으로 알려진 몇가지 재료들을 중간층으로 먼저 충전한 후 충전용 복합레진으로 충전한 뒤 치은부 변연에서 이들 중간층과 치질 사이의 미세누출의 정도를 비교하였다. 20개의 발거된 구치의 근, 원심면에 각각 상자 모양의 2급 와동을 형성하고 40개의 와동을 무작위로 10개씩, 4개의군으로 나누었다. 1군은 중간층의 수복없이 Clearfil SE Bond과 Clearfil AP-X로 충전하였으며 2, 3 및 4군은 중간층으로 각각 Revolution, Dyract그리고 FujiII LG를 먼저 충전한 후 1군과 동일한 방법으로 복합레진을 충전하였다. 충전된 시편은 열순환후 2% methylene blue 용액에 12시간 침잠시킨 후 색소의 침투도를 stereomicroscope로 관찰하였으며 실험결과는 Kruskal-Wallis non-parametric independent analysis 및 Mann-Whitney U test로 통계분석하여 다음의 결론을 얻었다. 1. 레진강화형 글라스아이오노머를 중간층으로 먼저 수복하고 복합레진으로 충전한 경우에서 더 적은 미세누출을 보였다(p<0.05). 2. 유동성 레진과 콤포머를 중간층으로 수복한 경우와 복합레진만으로 수복한 경우는 미세누출에 있어서 유의한 차이를 나타내지 않았다(p>0.05).

An Experimental Study on Microleakage in Light-activated Temporary Filling Materials (광중합형 임시충전재의 미세누출에 관한 실험연구)

  • Hwang, Su-Hyun;Yu, Ji-Su;Kim, Sun-Ju
    • Journal of dental hygiene science
    • /
    • v.11 no.4
    • /
    • pp.333-337
    • /
    • 2011
  • The purpose of this experiment was to examine possibility of microleakage by water, temperature change, and bite force inside the mouth during the period of using light-activated temporary filling materials. 2 kinds of light-activated temporary filling materials were used in order to measure weight and compressive strength and to evaluate microleakage between filling material and cavity wall according to frequency of thermal circulation. First, Light-activated temporary filling material was increased the weight, which was measured according to the period of using. As for the result of comparing between products, the weight of Quicks was indicated to be higher. Second, Compressive strength of Spacer had significant difference depending on period of using. However, significant difference wasn't shown in the compressive strength of Quicks. In Spacer that showed significant difference, the compressive strength increased greatly in the difference of 3 days. Third. As for micro-leakage according to frequency of thermal circulation, the microleakage was indicated to be the highest in the group that carried out 7,000 times. The group with operation of 1,000 times and the group with operation of 3,000 times were indicated the statistically lower micro-leakage than the group with operation of 7,000 times. This study brought about a rise in micro-leakage depending on the passage in the period of using. However, it is obvious fact that micro-leakage increases according to the passage of time after restoration.

AN IN VITRO STUDY OF MICROLEAKAGE OF COMPOSITE RESINS (복합레진의 미세누출에 관한 연구)

  • Lee, Sun-Young;Yang, Yeon-Mi;Baik, Byeong-Ju;Jeon, Cheol-Wan;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.4
    • /
    • pp.593-599
    • /
    • 2003
  • The purposes of this study were to evaluate the microleakage of class V composite resin restorations utilizing the different curing lights, to assess the flowable resin, $Filtek^{TM}Flow$(3M Dental Products, USA) and composite resin, $Filtek^{TM}Z250$(3M Dental Products, USA) which need 20s curing time for halogen light could replace $Z100^{TM}$ Restorative(3M Dental Products, USA) for the microleakage, and to evaluate the effect of adhesive resin on marginal microleakage. Light curing units used in this study were conventional halogen light, XL3000(3M Dental Products, USA) and plasma arc light, Flipo(Lokki, France). Class V cavities were prepared and each cavity was filled with each composite resin. After being filled, the teeth were stored in distilled water, polished, thermocycled and soaked in 1% methylene blue solution. Following results were obtained from evaluation of the sectioned surface. 1. There was no statistically significant difference in microleakage of $Filtek^{TM}Flow$ and $Filk^{TM}Z250$ between two kinds of curing units(p>0.05). 2. Flowable resin, $Filtek^{TM}Flow$ showed more microleakage than Z100 and $Filtek^{TM}Z250$ regardless of curing units(p<0.05). 3. Adhesive resin reduced the microleakage of composite resin in both halogen light and plasma arc light(p<0.05).

  • PDF

A Technology of Micro-leak Detection (미세 누출 탐지 기술)

  • Choi, Yourak;Lee, Jaecheol;Cho, Jaewan
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2021.07a
    • /
    • pp.685-687
    • /
    • 2021
  • 본 논문에서는 플랜트 배관의 기체 누출 탐지방안에 대하여 기술한다. 배관 누출 발생 시 배관 내부 압력과 누출부 크기의 조합에 따라 누출 초음파 발생 여부가 결정되는데, 누출 시 초음파가 발생하는 경우와 그렇지 않은 경우에 대하여 배관 누출을 탐지하는 방안과 보온재 배관의 누출탐지 방안에 대하여 설명한다. 또한 배관 파단을 상시감시하기 위한 대량의 무선센서 운용에 따른 대량 누출탐지신호의 실시간 처리를 위한 쿠버네티스 기반의 분산처리형 진단 시스템 구현 방안에 대하여 기술한다.

  • PDF

Comparison of Mechanical Properties between Bulk-fill and Conventional Composite Resin (Bulk-fill과 Conventional 복합레진의 물성비교)

  • Seok, Ujeong;Kim, Jongbin;Kim, Kiseob;Kim, Jongsoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.4
    • /
    • pp.427-434
    • /
    • 2016
  • The aim of this study was to compare the mechanical properties of high viscosity bulk-fill resin composites, $Filtek^{TM}$ Bulk Fill Posterior Restorative (FBF) and $Tetric^{(R)}$ N-Ceram Bulk Fill (TBF), with conventional composite ($Filtek^{TM}$ Z-350 XT, Z-350). The Vickers hardness test which indicates the degree of conversion was performed and the dye penetration test was performed to measure the microleakage which indicates polymerization shrinkage amount. To minimize experimental error, the standardized 3D-printed molds and the bovine teeth were used. Obtained data were analyzed by the Kruskal-Wallis test and Mann-Whitney test with the confidence interval of 95%. In the microhardness test within 1 hour of polymerization, lower surface of FBF and TBF showed significantly lower value than that of Z-350 (p < 0.05). But after 24 hours, the microhardness of FBF had increased and showed no significant difference with Z-350 (p > 0.05). In top and 2 mm depth surface, mean microhardness values were in the following order: Z-350 > FBF > TBF (p < 0.05). The mean microleakage value of TBF was significantly lower than others (p < 0.05). For clinical application of bulk-fill resin composites, caution for applying masticatory forces during 24 hours after polymerization is advised and further studies to decrease microleakage should be conducted.

INFLUENCE OF FLOWABLE COMPOSITE LINING THICKNESS ON CERVICAL MICROLEAKAGE OF PROXIMAL BOX (구치부 인접면 와동에서 유동성 복합레진 이장재의 두께가 치은 변연부 미세누출에 미치는 영향)

  • Cho, Yun-Jung;Kim, Tae-Wan;Kim, Hyun-Jung;Kim, Young-Jin;Nam, Soon-Hyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.2
    • /
    • pp.259-267
    • /
    • 2008
  • This in vitro study aimed to investigate the influence of flowable composite lining with different thicknesses on the marginal quality. One hundred twenty cavities, each preparated with proximal boxtype( 3mm of bucco-lingual width, 2mm of mesio-distal depth and gingival margin of 1mm supra-CEJ) were randomly dived into four groups. group I : Tetric ceram filling alone(control group) group II: 0.5mm thickness Tetric flow + Tetric ceram filling group III: 1.5mm thickness Tetric flow + Tetric ceram filling group IV: 2.5mm thickness Tetric flow + Tetric ceram filling The followings are the results: 1. Group II showed significantly less microleakage compared to group I(control group)(p<0.05). 2. There was no statistically significant difference between group III, IV and group I(p>0.05). 3. Group II showed significantly less microleakage compared to group III, IV(p<0.05). 4. There was microleakage more or less in all group. It was concluded that 0.5mm flowable composite lining improved cavity adaptation and marginal sealing.

  • PDF