• 제목/요약/키워드: 미세전류

검색결과 441건 처리시간 0.027초

급성 외측 상과염 치료를 위한 휴대용 미세전류자극기 개발 및 효과 검증 (Development and Evaluation of a Portable Micro-Current Stimulator for Acute Lateral Epicondylitis)

  • 권혁찬;이현주;태기식
    • 대한의용생체공학회:의공학회지
    • /
    • 제40권2호
    • /
    • pp.68-74
    • /
    • 2019
  • Lateral epicondylitis is caused by repeated use of the wrist, which causes inflammation and pain in the wrist extensor and tendon of the humerus. Delayed onset muscle soreness (DOMS) caused by repetitive resistance exercise affects the tendons connected in series with the muscle, leading to lateral epicondylitis. Although micro-current stimulation has been suggested as a possible treatment for tendinitis, there are insufficient studies on specific variables such as frequency. In this study, 15 healthy adult males and females developed DOMS in the wrist extensor and tendon in the humerus. The experimental group consisted of a low frequency group applying 20 Hz and a high frequency group applying 100 Hz according to the micro-current frequency. Each subject underwent an experiment for 5 days after DOMS, and the recovery rates were compared by measuring AROM, GPT, MST, PPT, and VAS. As a result, the 20 Hz group showed significant changes in AROM, MST, and VAS compared to the control group on the 4th day, and the recovery rate was also higher than that of the 100 Hz group. On the 5th day, recovery rate of 100 Hz group was higher than 20 Hz in AROM and PPT, and MST showed higher recovery rate than 20 Hz group, but there was no significant difference. These results indicate that microcurrent stimulation is effective for the treatment of delayed myalgia and tendon inflammation and that the 100 Hz group has faster recovery than the 20 Hz group.

미세 전류 자극에 따른 복부 체지방 감소 및 다이어트 효과에 대한 임상 시험 연구 (Potential Effects of Micro-Current Stimulation for Reduction of Abdominal Fat and Weight Loss: Clinical Study)

  • 조승관;김성국;김동현;김서현;이한아;황동현;김용민;신태민;김한성
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권6호
    • /
    • pp.284-296
    • /
    • 2018
  • Obesity is considered as a primary health problem over the past century in line with life environmental changes. It is mainly associated with increased risk of numerous chronic diseases which may significantly reduce health-related quality of life. Therefore, efforts to reduce weight should be performed. This study suggested a novel approach to reduce body fat by applying external stimulation which is micro-current stimulation (MCS). In this clinical study, we evaluated the potential effects of MCS for reduction of abdominal fat and weight loss. Prior to the clinical test, computational simulation was conducted to find the proper MCS conditions that allow externally applied stimulation to reach the internal fat section from the external skin. Particularly, the clinical study evaluated the unilateral effects of MCS for body fat loss and lipolysis without any additional limitations such as physical exercise and dietary therapy. The results showed that whole body fat, waist circumferences, and abdominal fat are gradually decreased after intervention in proportion to the time. From the results, we can estimate that MCS can be effective on the body fat loss by activation of lipolysis in human adipose.

펄스전류 활성 소결에 의해 제조된 나노크기의 TiAl계 금속간화합물의 미세구조와 기계적 특성에 미치는 고에너지 기계적 밀링시간의 영향 (Effect of High-Energy Mechanical Milling Time on Microstructure and Mechanical Properties of the Nano-sized TiAl Intermetallic Compounds Fabricated by Pulse Current Activated Sintering)

  • 김지영;우기도;강덕수;김상혁;박상훈
    • 대한금속재료학회지
    • /
    • 제49권2호
    • /
    • pp.161-166
    • /
    • 2011
  • The aim of this study was to determine the effect of high-energy mechanical milling (HEMM) time and sintering temperature on microstructure and mechanical properties of the TiAl composite fabricated by pulse current activated sintering. TiAl intermetallic powders were milled by HEMM for 1h, 4h, and 8h respectively. Thermal analysis was used to observe the phase transformation of the milled TiAl powders. The sintering time decreased with increase of milling time. The hardness and fracture toughness of the sintered specimens also was improved with increasing milling time. The grain size of the sintered specimens which was milled for 4h was in the range of 50~100 nm.

SM490-TMC 후판(40 mm) 강재의 SAW 용접을 통한 기계적 특성 연구 (A Study on Mechanical Properties of SM490-TMC Back Plate(40 mm) Steel by SAW Welding)

  • 이성준
    • 한국산학기술학회논문지
    • /
    • 제22권3호
    • /
    • pp.88-93
    • /
    • 2021
  • 선박의 건조과정이나 압력용기의 몸체 부분을 용접할 경우 많이 사용되는 SAW(Submerged Arc Welding)는, 용접 부위에 분말 형태의 용제(Flux)를 일정 두께로 살포하고 그 속에 전극 와이어를 연속적으로 공급하여 용접이 이루어지는 방법으로 용접 시 발생되는 아크열이 외부로 노출되지 않는 특징이 있으며, 잠호용접으로 불리기도 한다. 또한 1,500~3,000A의 전류까지 통전 할 수 있는 고전류 용접이 가능하며 아크효율이 95% 이상, 미세한 금속 산화물 입자인 Welding Fume 발생량이 적고 아크광선이 외부로 노출되지 않아 청정한 작업이 가능하며 용입이 깊고 결함이 잘 발생하지 않아 용접 이음부의 신뢰도가 높다. 본 연구에서는 SM490C-TMC 후판을 서브머지드 아크용접(SAW)을 이용하여 이종 용접한 후 용접부의 기계적 특성을 인장, 경도, 매크로, 자분탐상 검사 결과를 분석하여 다음과 같은 결론을 도출하였다. 굽힘 시험 결과 시료에서 표면의 터짐 현장이 발생하지 않았고 기타 결점의 유무를 확인할 수 없었으며, 이는 용접 이후 소성변형 과정에서도 충분한 인성을 발휘하고 있는 것으로 나타났으며, 1F 용접 방법이 굽힘 성능에 문제가 없는 것으로 판단되었다.

초박형 미세전류패치 적용이 만성 허리통증 환자의 통증과 허리 가동성에 미치는 영향 (Effects of ultra-thin microcurrent patch application on pain and mobility in patients with chronic low back pain)

  • 황태연;박재철
    • 대한물리치료과학회지
    • /
    • 제29권4호
    • /
    • pp.86-95
    • /
    • 2022
  • Background: The purpose of this study is to investigate the effect of ultra-thin microcurrent patch application on pain, tenderness, trunk flexion, and trunk extension in patients with back pain. Design: pretest-posttest design: single blind. Methods: Thirty men and women diagnosed with chronic back pain were classified into 15 microcurrent application groups and 15 placebo groups. Changes in pain were observed on a visual analog scale, tenderness was observed with a digital tenderness meter, and changes in trunk flexion and trunk extension angles were evaluated with a posture analyzer. The paired t-test was used to see the changes within each group before and one week after the experiment, and the independent t-test was used to see the change in the difference between the groups, and the significance level was 0.05. Results: In both the experimental group and the control group, there was a significant difference in pain within and between groups(p<0.05). In the experimental group, there were significant differences in the intra- and inter-group changes in the erector spinae muscle tenderness and low back pain disorder index(p<0.05). In the experimental group, there was a significant difference in the change in trunk flexion and extension within the group(p<0.05). Conclusion: In this study, it was confirmed that the application of ultra-thin microcurrent was effective for pain, tenderness, and movement of back extension in patients with low back pain. It is expected that it will be used as a basic data for microcurrent therapy and as a treatment method for improving the function of patients with back pain in the future.

산화그래핀 기능화에 의한 시멘트 복합체의 전기전도 특성 개선 (Enhanced Electric Conductivity of Cement Composites by Functionalizing Graphene Oxide)

  • 한중근;전재현;김영호;김진;이종영
    • 한국지반신소재학회논문집
    • /
    • 제22권1호
    • /
    • pp.1-7
    • /
    • 2023
  • 본 연구에서는 화학적 박리를 통해 흑연분말로부터 분리한 산화그래핀의 전기적특성을 개선시키기 위해 자가조립단층막 기술을 활용하였다. 반응물질로는 황산알루미늄(Al2(SO4)3)을 적용하였으며, 시멘트를 기반으로 한 건설구조물의 자가센싱에 적용하기 위한 기초연구를 수행하였다. 전기저항 측정결과 대조군인 표준공시체와 대비할 때 GO 및 Al-GO가 함유된 공시체에서 각각 10.2%, 15.9% 개선되어 도체로서의 활용 가능성을 확인하였다. 미세구조분석 결과 Al-GO의 첨가에 따라 Al(OH)3 gel형성을 확인하였으며, 이로 인해 공시체의 밀도를 향상시켜 전류의 흐름을 원활하게 개선시킨 것으로 판단된다. 이는, 단순 구조물이 아닌 구조물 자체로서 활용성을 지닐 수 있음을 시사하며, 스마트 건설자재로서의 가능성을 확인하였다.

요추부 추간판 탈출증 환자에 대한 고전압 미세전류치료의 누적치료효과 (Cumulative Therapeutic Effect of High-Voltage Microcurrent Therapy in Patients with Herniated Lumbar Disc)

  • 윤왕현;박진영;김도영;박중현
    • Clinical Pain
    • /
    • 제18권2호
    • /
    • pp.65-69
    • /
    • 2019
  • Objective: This study aims to evaluate the efficacy of high-voltage microcurrent therapy in patients with herniated lumbar disc (HLD) presenting radicular or back pain. Method: This is a retrospective study with 33 patients who are complaining pain with HLD findings on magnetic resonance image. Microcurrent therapy was applied to leg or paralumbar area. Treatment was conducted for seven minutes with 250~1000 uA intensity as high as the patients could tolerate via stimulating probe with roller type and the frequency was 60 Hz with a sine wave pulse. The visual analogue scale (VAS) was measured just before and after the treatment. Results: The degree of pain reduction (△VAS) was 1.6 points after treatment on average. The △VAS according to the diagnosis, stenosis, dermatome area, medication, pain site and caudal epidural block was not statistically significant. However, the △VAS according to the number of treatments (< 3, ≥ 3 times) showed a statistically significant difference (p=0.04). Conclusion: High-voltage microcurrent therapy may help reduce lumbar or lumbosacral radiating pain after the procedure. The effect was better when microcurrent was applied three times or more. This result suggests that the microcurrent would have cumulative effect on reducing radicular or back pain in patients with HLD.

Clarke 변환을 응용한 3상 유도전동기의 Inter Turn Short Circuit 진단 (Diagnosis of Inter Turn Short Circuit in 3-Phase Induction Motors Using Applied Clarke Transformation)

  • 고영진;김경민
    • 전기전자학회논문지
    • /
    • 제27권4호
    • /
    • pp.518-523
    • /
    • 2023
  • 고정자 권선단락은 미세한 턴이 단락되어 급격히 고장이 심각해짐에 따라 ITSC의 진단이 중요시되고 있다. 그러나, 3상 유도전동기의 노이즈 및 손실등과 유사한 특징을 가짐에 따라 ITSC진단에 많은 어려움이 있다. 이를 효율적으로 진단하기 위해서 인공지능 기법으로 연구되고 있으나, 현장에서는 모델기반 기법이 두루 활용되고 있음에 따라 모델기반 기법에 대한 진단 성능개선 연구가 필요한 실정이다. 이에 본 논문에서는 회전하고 있는 자속에 변화를 무시하며, 전류 성분만을 이용할 수 있도록 Clarke변환 방법을 응용하여 진단방법을 제안하였다. 이에 30분간의 정상 및 ITSC 상태의 측정 결과, 정상상태를 ITSC 상태로 오인식하는 경우 0.2[%], ITSC상태를 정상상태로 오거부하는 경우 0.26[%]로 효율적인 진단 방법임을 실험을 통해 알 수 있었다.

선박용 강판의 수중 용접 최적화에 관한 연구 (Optimization for Underwater Welding of Marine Steel Plates)

  • 오세규
    • 수산해양기술연구
    • /
    • 제20권1호
    • /
    • pp.49-59
    • /
    • 1984
  • 선박용 강판(KR Grade A-1, SWS41A, SWS41B)의 수중용접 최적화에 관한 연구결과를 요약하면 다음과 같다. 1. 국산 라임티타니아계 용접봉 피복제의 흡수속도는 약 60분에서 일정하게 되고, 침수시간 8분까지의 흡수속도는 약 0.15%/min 였으므로 40cm 용접기간중의 정미 흡수량은 약 0.22%미만에 불과하였다. 2. 위의 이유와 건조, 직접, 침수용접봉에 의한 대기중, 수상, 수중용접과 모재의 인장강도 및 미시조직 비교실험결과에 의하면, 수중용접시간이 8분이내의 충분히 짧은 때에는 강도상 건조된 직접용접봉의 사용이 가능할 것이다. 3. 용접조건이 수중용접비이드에 미치는 영향을 KR Grade A-1강판에 대하여 조사한 결과, 용접각도는 60$^{\circ}$, 용접전류는 160A정도, 용접봉지름은 4mm인 경우가 적합하며, 또한 비이드외관과 X-선검사에 의하면 일미나이트, 라임티타니아, 고산화티탄계 용접봉이 가장 적합하였다. 4. 위의 용접봉 종류와 각 지름에 대해 비이드외 관검사에 의한 적정 수중용접전류의 범위는 어느 일정 범위내에 제한되며, 용접봉지름의 증가에 따라 전류는 증가하는 경향이다. 5. 수중용접부의 용착금속부에 관한 기계적특성조사에 의하면, 인장강도와 항복강도는 입열량과 이차함수적 관계가 성립되고, 이음효율이 100% 이상의 범위가 존재하며, 충격치와 스트레인은 모재의 경우보다 낮으나 그 증가현상이 고입열량 범위에서 존재하므로, SWS41A에 대한 수중용접 최적입열량범위는 약 13~15KJ/cm이다. 한편, 인장-인장 편진 피로한도가 모재의 경우보다 높고, 충격치와 연신율을 고려하여 구한 최적입열량의 범위는 약 16~19KJ/cm로서, 피로강도를 높이기 위한 입열량은 정적 인장강도때보다 고입열량으로 수중용접해야 한다. 이때 모든 실험식의 신뢰성은 95%수준이다. 6. 수중용접부에 대한 X-선검사와 미시조직검사 및 경도분포조사에 의하면 용접결함은 발견되지 않았으며, 특히, 깊이 1mm 표층부의 모재측 열영향부와 본드(bond)와의 경계부근에 경도 Hv400 max으로서 미세 마르텐사이트, 베이나이트, 퍼얼라이트와 소량의 조대한 입계페라이트 조직이며 그 외의 부위는 퍼얼라이트와 페라이트 조직으로서, 수소취성영향의 극심한 경도증가 및 조직은 발견되지 않았다. 7. 위에서 구한 입열량의 최적범위 내에서의 제어에 의하여 수중용접 할 경우, 신뢰성 있는 용접품질의 최적화가 가능할 것이다.

  • PDF

RF 마그네트론 스퍼터링법에 의한 $SrTiO_3$박막제조와 유전특성 (Preparation of $SrTiO_3$ Thin Film by RF Magnetron Sputtering and Its Dielectric Properties)

  • 김병구;손봉균;최승철
    • 한국재료학회지
    • /
    • 제5권6호
    • /
    • pp.754-762
    • /
    • 1995
  • 차세대 LSI용 유전체 박막으로서의 응용을 목적으로 RF 마그네트론 스퍼터링법으로 Si기판위에 SrTiO$_3$박막을 제조하였다. Ar과 $O_2$혼합가스 비, 바이어스 전압변화, 열처리 온도등의 증착조건을 다양하게 변화시키며 SrTiO$_3$박막을 제조하여 최적의 증착조건을 조사하였다. 박막의 결정성을 XRD로, 박막과 Si 사이의 계면의 조성분포를 AES로 각각 분석하였다. Ar과 $O_2$의 혼합가스를 스퍼터링 가스로 사용함으로써 결정성이 좋은 박막을 얻었다. 그리고 보다 치밀한 박막을 얻고자 바이어스 전압을 걸어주며 증착시켰다. 본 실험결과에서는 스퍼터링 가스는 Ar+20% $O_2$혼합가스, 바이어스 전압은 100V에서 좋은 결정성을 얻었다. 또한 하부전극으로 Pt, 완충층으로 Ti를 사용함으로써 SrTiO$_3$막과 Si 기판과의 계면에서 SiO$_2$층의 형성을 억제할 수 있었으며, Si의 확산을 막을 수 있었다. 전류 및 유전특성을 측정하기 위해 Au/SrTiO$_3$/Pt/Ti/SiO$_2$/Si로 구성된 다층구조의 시편을 제작하였다. Pt/Ti층은 RF 스퍼터링으로, Au 전극은 DC 마그네트론 스퍼터링법으로 증착시켰다 $600^{\circ}C$로 열처리함에 의해 미세하던 결정림들이 균일하게 성장하였으며, 이에 따라 유전율이 증가하고 누설전류가 감소하였다. $600^{\circ}C$에서 열처리한 두께 300nm의 막에서 유전율은 6.4fF/$\mu\textrm{m}$$^2$이고, 비유전상수는 217이었으며, 누설전류밀도는 2.0$\times$$10^{-8}$ A/$\textrm{cm}^2$로 양질의 SrTiO$_3$박막을 제조하였다.

  • PDF