• 제목/요약/키워드: 미끄럼계수

검색결과 107건 처리시간 0.022초

O-Y·PSM에 의한 CSR과 보행분석에 의한 RCOF와의 관계 (Relationship between RCOF Calculated from the Results of Gait Analysis and CSR Measured Using O-Y·PSM)

  • 노용운;최수경
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.59-61
    • /
    • 2013
  • The purpose of this study was to present the necessary data concerning the selection and development of floor-coverings in view of slipperiness by comparing the relationship between CSR measured with O-Y·PSM and RCOF calculated from the result of gait analysis. CSR was calculated from maximum tensile load(Pmax) divided by perpendicular load(785N) when pulled 18 degrees upward the moment the bottom of the slip piece contacted the surface of the test piece. RCOF was calculated based on Fy/Fz from when horizontal load reached the maximum point within the sections from the moment the front of outsole touched the test piece to when pulled off the test piece. The results from the research were as follows: (1) Range of CSR was 0.15-1.02, which meant the differences of slipperiness of the test pieces definitely showed up. (2) RCOF are inadequate to express the characteristic about the slipperiness of the floors, since there were no differences between the test pieces.

  • PDF

$AL_{2}O_{3}$ 세라믹의 순도에 따른 마찰 마모 특성 연구 (A Study on the Friction and Wear Characteristics with Purity on $AL_{2}O_{3}$ Ceramic)

  • 전찬열;오성모
    • 한국산학기술학회논문지
    • /
    • 제6권5호
    • /
    • pp.439-445
    • /
    • 2005
  • 세라믹을 실링, 펌프부품, 미터계 부품 등에 이용할 때 마찰마모 특성은 매우 중요하다. 본 연구에서는 알루미나를 기계적 및 마찰마모의 특성에 미치는 영향을 고찰 하였다. 미끄럼거리와 미끄럼 속도, 그리고 마모량과 마찰계수 등을 서로 다른 순도에 따라 측정하고, 결정상 분석과 미세구조는 각각 XRD와 SEM으로 조사하였다. 알루미나의 순도 95$\%$가 상대적으로 마모량이 가장 크고, 순도 99.7$\%$가 마찰계수와 마찰마모 저항성이 우수하였다.

  • PDF

마찰시험기의 하중부와 방법과 강성 변화에 따른 미끄럼 마찰특성 평가 (Evaluation of the Sliding Frictional Characteristics at the Different Loading Mechanisms and Dynamic Stiffness)

  • 윤의성;공호성;권오관;오재응
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1996년도 제23회 춘계학술대회
    • /
    • pp.108-116
    • /
    • 1996
  • 본 논문에서는 하중부와 방법을 추(dead weight)와 공압(pneumatic)을 이용한 방법에서 스프링을 이용한 방법을 추가하였으며, 압축형 스프링을 선택적으로 사용하여 마찰시험기 수직방향에서의 강성을 큰 변화 폭으로 변화시켰다. 또한 선행된 연구를 통하여 수직하중의 변동량에 크게 영향을 미치는 것으로 알려진 바 있는 디스크 시편의 misaligment 효과를 상사하고 극대화 하기 위하여 본 논문에서는 경사진 디스크 시편을 추가로 사용하였다. 상기조건으로 마찰시험기 시스템의 각 하중부과 방법과 수직강성 변화가 마찰특성에 미치는 영향을 실험적으로 측정 평가하였으며, 마찰시험기 동특성계 모델의 이론적 해석을 통하여 마찰특성 변화를 고찰하였다. 또한, 미끄럼 접촉 시의 수직력과 마찰력을 측정하고, 데이터의 통계적 처리방법에 따른 마찰계수의 변화 특성도 평가하였다.

  • PDF

저소음 고효율 시로코 홴 개발에 관한 연구 (A study on Low-Noise and High-Efficiency Sirocco Fan Development)

  • 박광진;이상환;손병진
    • 한국유체기계학회 논문집
    • /
    • 제2권2호
    • /
    • pp.46-56
    • /
    • 1999
  • This study is on the performance prediction and design of a sirocco fan. Slip coefficient is very important factor for the performance analysis of a centrifugal-type fan. Because generally used slip coefficient equations of backward curved centrifugal fan are not appropriate for forward curved sirocco fan, in this study a proper slip coefficient equation for a sirocco fan is suggested. Using this equation performance prediction program for sirocco fan is composed of and also included the total noise prediction that include the turbulent noise at the fan inlet and boundary layer noise. A comparison between the values obtained from performance prediction program and experimental values shows that the program predicts the sirocco fan performance in a practical rate.

  • PDF

양정곡선 기울기를 고려한 원자로 냉각재 펌프의 수력설계 (Hydraulic Design of Reactor Coolant Pump Considering Head Curve Slope at Design Point)

  • 유일수;박무룡;윤의수
    • 한국유체기계학회 논문집
    • /
    • 제14권1호
    • /
    • pp.18-23
    • /
    • 2011
  • The hydraulic part in reactor coolant pump consists of suction nozzle, impeller, diffuser, and discharge nozzle. Among them, impeller is required to be designed to satisfy performance requirements such as head, NPSHR, and head curve slope at design point. Present study is intended to suggest the preliminary design method sizing the impeller size to satisfy the design requirement particularly including head curve slope at design point. On a basis of preliminary design result, hydraulic components have been designed in detail by CFD and then manufactured in a reduced scale. Experiment in parallel with computational analysis has been executed in order to confirm the hydraulic performance. Comparison results show good agreement with design result, confirming the validity of design method suggested in this study.

遠心 임펠러의 相對 渦流 크기 모델에 根據한 이론적인 미끄럼 係數 (An Analytical Slip Factor Based on a Relative Eddy Size Model for Centrifugal Impellers)

  • 팽기석;정명균
    • 대한기계학회논문집B
    • /
    • 제24권3호
    • /
    • pp.411-418
    • /
    • 2000
  • By calculating the location and size of the relative eddy formed in the rotating impellers with the logarithmic spiral vanes, a new simple but accurate slip factor is analytically derived. The proposed slip factor depends on only one parameter that is a function of the number of vanes and the vane exit angle. Predicted slip factor for various cases are compared with those estimated by a number of previous slip factors as well as a recent theoretical calculation by Visser et al. ( JFM, Vol. 268, pp. 107-141, 1994). It is found that the present slip factor yields almost similar results to Wiesner's which has been empirically formulated based on the theoretical calculation of Busemann.

저소음 고효율 시로코 팬 개발에 관한 연구 (A study on low-noise and high-efficiency sirocco fan development)

  • 박광진;이상환;손병진
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1998년도 강연회 및 연구개발 발표회 논문집
    • /
    • pp.63-72
    • /
    • 1998
  • This study Is on the performance prediction and design of sirocco fan. Slip coefficient is very important factor for the performance analysis of centrifugal-type fan. Because generally used slip coefficient equations of backward curved centrifugal fan are not appropriate for forward curved sirocco fan, in this study a proper slip coefficient equation for sirocco fan is suggested. Using this equation performance prediction program for sirocco fan is composed and also included the total noise prediction that include turbulent noise at the fan Inlet and boundary layer noise. A comparison between the values obtained from performance prediction program and experimental values shows that the program predicts the sirocco fan performance in a practical rate.

  • PDF

미끄럼 방지 제동장치용 유압모듈레이터의 압력 특성 해석에 관한 연구 (A Study on the Analysis of Pressure Characteristics of Hydraulic Modulator for Anti-Lock Brake System)

  • 송창섭;양해정
    • 한국정밀공학회지
    • /
    • 제13권8호
    • /
    • pp.120-127
    • /
    • 1996
  • Anti-lock Brake System has been developed to reduce tendency for wheel lock and improve vehicle control during sudden braking on slippery road surfaces. This is achieved by controlling the braking pressure, avoiding wheel lock, while retaining handling and brake performance. This paper is concerned about pressurecharacteristics of hydraulic modulator. Experimental sets which is consists of hydraulic modulator, duty controller, pressure regulator, pressure senset is consuructed. System modelling and computer simulation are performed for comparison with experimental results. Brake wheel pressure are measured under various driving pulse. The result of experiment show fairly agreement with the simulation. As a result, it is known that wheel pressure is affected by duty ratio, orifice diameter through computer simulation.

  • PDF

휨을 받는 고장력볼트 체결부에서 과대공에 따른 사용성에 관한 연구 (A Study on Serviceability of Oversized Bolt Hole in High-Tension Bolt Joint Subjected to Bending)

  • 박정웅;양승현;장석인
    • 한국산학기술학회논문지
    • /
    • 제10권10호
    • /
    • pp.2831-2836
    • /
    • 2009
  • 고장력볼트를 이용한 강부재의 연결부에서 마찰력을 초과하는 설계하중이 작용하여 미끄럼이 발생하는 점을 기점으로 볼트와 모재의 전단강도 및 지압강도에 의해 설계하중을 지지하게 된다. 미끄럼량은 볼트의 장력, 접촉면의 마찰계수, 모재구멍내에서 볼트의 위치에 따라 결정되어 질 수 있다. 본 연구에서는 모재 및 덮개판에 대하여 볼트구멍의 크기를 변화시켜 제작된 고장력볼트 체결부에 순수굽힘과 인장력이 작용하는 경우 표준공과 과대공에 따른 미끄럼을 측정하고 비교분석하였다. 표준공을 가지는 경우보다 과대공을 가지는 경우에 $74\sim94%$ 작은 하중에서 미끄럼이 발생하였다. 인장력을 받는 부재에서는 과대공치수가 클수록 미끄럼 하중비가 작게 나타났으며 모재의 과대공치수가 덮개판의 과대공치수보다 미끄럼하중변화와 연관성이 많은 것으로 나타났다.

볼트 구멍 크기에 따른 TS 고력볼트 접합부 거동 평가 (Evaluation on the Behavior of Slip Critical Joints with TS High Strength Bolts Subjected to a Size of Bolt Holes)

  • 이현주;김강석;나환선;이강민;김현철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권2호
    • /
    • pp.136-143
    • /
    • 2011
  • 고력볼트의 현장 조립시 볼트 구멍 간의 불일치로 인하여 볼트 구멍을 확장하는 경우가 빈번하게 발생하고 있으며, 이를 위해서 외국 기준에서는 볼트 구멍 크기, 형태, 하중 방향에 따라 미끄럼하중에 대한 규정을 따로 두고 있다. 그러나 우리나라의 경우 과대구멍에 대한 시방규정이나 이에 대한 접합부 특성에 관한 연구는 미흡한 실정이다. 따라서, 접합부재 표면처리와 볼트구멍 크기의 변화가 접합부 내력에 어떠한 영향을 미치는 지를 실험을 통해 정량적으로 평가할 필요가 있다. 본 연구에서는 볼트 구멍 크기 및 형태에 따른 접합부의 미끄럼하중의 변화와 체결 후, 장기축력이완의 경향을 분석하기 위하여 160시간 및 800시간 동안 고력볼트의 축력의 변화를 측정하였다. 본 실험대상 고력볼트로 KS B 2819에 규정된 TS(Torque Shear)형 고력볼트를 사용하였다. 표준 볼트구멍 대비 그 외 볼트구멍의 미끄럼하중의 변화는 10% 미만으로 나타났으며, 장기축력이완은 직경 2.5배의 슬롯구멍에서, 2.66%로 가장 높게 나타났다.