• Title/Summary/Keyword: 물질전달 계수

Search Result 187, Processing Time 0.022 seconds

A Study on Proliferation and Phenotypical Stability of Schwann Cell on Keratin/PLGA Film (케라틴이 첨가된 PLGA 필름에서 케라틴 함량별 SC세포의 증식 및 형태유지에 관한 연구)

  • Oh, A-Young;Kim, Soon-Hee;Kim, Yun-Tae;Jeon, Na-Ri;Yang, Jae-Chan;Lee, Sang-Jin;Yoo, James-J.;Van Dyke, Mark;Shin, Hyung-Sik;Rhee, John-M.;Khang, Gil-Son
    • Polymer(Korea)
    • /
    • v.33 no.2
    • /
    • pp.118-123
    • /
    • 2009
  • Keratin contains regulatory molecules that can enhance neuronal cell activity. We fabricated keratin/ PLGA films using 0, 10, 20, and 50 wt% of keratin using solvent casting method. We measured the contact angle of each film and cell proliferation was assayed by counting the cells attached on the film. Adhered cell morphology was confirmed by scanning electron microscope. RT-PCR was conducted to evaluate the gene expression of NF, NSE, and S-100, the Schwann cell markers. The keratin content of 20 and 50 wt% provided higher wettability than PLGA. The 20 wt% keratin was better in cell adhesion and proliferation of SCs than other keratin/PLGA films. The phenotypic stability of SC was maintained with the keratin content of 10 and 20 wt%.

Comparative and Feasibility Evaluation of Detection Ability of Relative Dosimeters using CsPbI2Br and CsPbIBr2 Materials in Brachytherapy QA (근접방사선치료 QA에서 CsPbI2Br과 CsPbIBr2를 이용한 상대 선량계들의 검출 능력 비교 및 적용가능성 평가)

  • Seung-Woo Yang;Sung-Kwang Park
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.433-440
    • /
    • 2023
  • High dose rate brachytherapy is a cancer treatment that intensively irradiates radiation to tumors by inserting isotopes with high dose rates into the body. For such a treatment, it is necessary to deliver an accurate dose to the tumor tissue through an accurate treatment plan while delivering only a minimum dose to the normal tissue. Therefore, it is very important to check the location accuracy of the source through accurate Quality Assurance (QA) in clinical practice. However, since the source position is determined using a ruler, automatic radiographer, video monitor, etc. in clinical practice, it yields inaccurate results. In this study, a semiconductor dosimeter using CsPbI2Br and CsPbIBr2 was fabricated. And, in order to analyze whether it is more suitable for the relative QA dosimeter for brachytherapy device among the two materials, the radiation detection ability of each was compared and evaluated. In order to evaluate the radiation detection ability in brachytherapy, the reproducibility and linearity of the two materials were evaluated in 192IR. In the reproducibility evaluation, CsPbI2Br presented a Relative Standard Deviatio(RSD) of 0.98% and CsPbIBr2 presented an RSD of 3.45%. In the linearity evaluation, the coefficient of determination (R2) of CsPbI2Br was presented as 0.9998, and the R2 of CsPbIBr2 was presented as 0.9994. As a result of the evaluation, it was found that CsPbI2Br was more stable in radiation detection while satisfying the evaluation criteria in the dosimeter manufactured in this experiment. Therefore, CsPbI2Br material is suitable for application as a relative dosimeter for radiation detection in brachytherapy devices.

A Review Study on Major Factors Influencing Chlorine Disappearances in Water Storage Tanks (저수조 내 잔류염소 감소에 미치는 주요 영향 인자에 관한 문헌연구)

  • Noh, Yoorae;Kim, Sang-Hyo;Choi, Sung-Uk;Park, Joonhong
    • Journal of Korean Society of Disaster and Security
    • /
    • v.9 no.2
    • /
    • pp.63-75
    • /
    • 2016
  • For safe water supply, residual chlorine has to be maintained in tap-water above a certain level from drinking water treatment plants to the final tap-water end-point. However, according to the current literature, approximately 30-60% of residual chlorine is being lost during the whole water supply pathways. The losses of residual chlorine may have been attributed to the current tendency for water supply managers to reduce chlorine dosage in drinking water treatment plants, aqueous phase decomposition of residual chlorine in supply pipes, accelerated chlorine decomposition at a high temperature during summer, leakage or losses of residual chlorine from old water supply pipes, and disappearances of residual chlorine in water storage tanks. Because of these, it is difficult to rule out the possibility that residual chlorine concentrations become lower than a regulatory level. In addition, it is concerned that the regulatory satisfaction of residual chlorine in water storage tanks can not always be guaranteed by using the current design method in which only storage capacity and/or hydraulic retention time are simply used as design factors, without considering other physico-chemical processes involved in chlorine disappearances in water storage tank. To circumvent the limitations of the current design method, mathematical models for aqueous chlorine decomposition, sorption of chlorine into wall surface, and mass-transfer into air-phase via evaporation were selected from literature, and residual chlorine reduction behavior in water storage tanks was numerically simulated. The model simulation revealed that the major factors influencing residual chlorine disappearances in water storage tanks are the water quality (organic pollutant concentration) of tap-water entering into a storage tank, the hydraulic dispersion developed by inflow of tap-water into a water storage tank, and sorption capacity onto the wall of a water storage tank. The findings from his work provide useful information in developing novel design and technology for minimizing residual chlorine disappearances in water storage tanks.

Strain Improvement and Bioprocess Optimization for Enhanced Production of Haluronic Acid(HA) in Bioreactor Cultures of Streptococcus zooepidemicus (히알루론산 생산성 향상을 위한 Streptococcus zooepidemicus 균주 개량 및 발효조 배양공정 최적화)

  • Kim, Soo Yeon;Chun, Gie-Taek
    • Microbiology and Biotechnology Letters
    • /
    • v.48 no.3
    • /
    • pp.344-357
    • /
    • 2020
  • Strain improvement and bioprocess development were undertaken to enhance hyaluronic acid(HA) production by Streptococcus zooepidemicus cells. Using a high-yielding mutant strain, statistical medium optimization was carried out in shake flask cultures, resulting in 52% increase in HA production (5.38 g/l) at the optimal medium composition relative to the parallel control cultures. For sufficient supply of dissolved oxygen (DO), which turned out to be crucial for enhanced production of HA, agitation system and speed were intensively investigated in 5 L bioreactor cultures. Increase in oxygen mass transfer coefficient (kLa) through increment of agitation speed (rpm) and 35% expansion of diameter of the newly-designed impellers showed significantly positive effects on HA production. By installing an expanded Rushton-turbine impeller for efficient break-down of sparged air, and an extended marine impeller above the Rushton-turbine impeller for efficient mixing of the air-born viscous fermentation broth, maximum amount of HA (9.79 g/l) was obtained at 450 rpm, 1.8 times higher level than that of the corresponding flask culture. Subsequently, the possibility of bioprocess scale-up to a 50 L bioreactor was investigated. Despite almost identical maximum HA production (9.11 vs 9.25 g/l), the average HA volumetric productivity (rp) of the 50 L culture turned out only 74% compared to the corresponding 5 L culture during the exponential phase, possibly caused by shear damages imposed on the producing cells at the high stirring in the 50 L culture. The scale-up process could be successfully achieved if a scale-up criterion of constant oxygen mass transfer coefficient (kLa) is applied to the 50 L pilot-scale bioreactor system.

Evaluation of Image Quality & Absorbed Dose using MCNPX Simulation in the Digital Radiography System (디지털방사선영상시스템에서 MCNPX 시뮬레이션을 이용한 영상 품질 및 선량평가)

  • An, Hyeon;Lee, Dongyeon;Ko, Sungjin;Kim, Changsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.327-335
    • /
    • 2016
  • The study is enforce to study image quality evaluation of condition provide the IEC and combination of clinical conditions each quality of radiation that image quality to assess the conditions provided to IEC in the clinical environment to conduct image quality assessment of the digital radiography system in the detector have environmental limits. First, image quality evaluation was evaluated by measuring the MTF, NPS using four quality of radiation and Using MCNPX simulation lastly DQE make a image quality evaluation after calculating the particle fluence to analyze spectrum quality of radiation. Second, Using MCNPX simulation of four quality of radiation was evaluated absorbed dose rate about electronic 1 per unit air, water, muscle, bone by using Radiation flux density and energy, mass-energy absorption coefficient of matter. Results of evaluation of image quality, MTF of four quality of radiation was satisfied diagnosis frequency domain 1.0 ~ 3.0 lp/mm of general X-ray that indicated 1.13 ~ 2.91 lp/mm spatial frequency. The NPS has added filter, spatial frequency 0.5 lp/mm at standard NPS showed a tendency to decrease after increase. Unused added filter, spatial frequency 0.5 lp/mm at standard NPS showed a certain NPS result value after decrease. DQE in 70 kVp / unuesd added filter(21 mm Al) / SID 150 cm that patial frequency 1.5 lp/mm at standard showed a tendency to decrease after certain value showed. Patial frequency in the rest quality of radiation was showed a tendency to decrease after increase. Results of evaluation of absorbed dose, air < water < muscle < bone in the order showed a tendency to increase. Based on the results of this study provide to basic data that present for the image quality evaluation method of a digital radiation imaging system in various the clinical condition.

Treatment of Malodorous Waste Air by a Biofilter Process Equipped with a Humidifier Composed of Fluidized Aerobic and Anoxic Reactor (폐가스 가습조(유동상호기 및 무산소조)를 포함한 바이오필터공정을 이용한 악취폐가스의 처리)

  • Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.56 no.1
    • /
    • pp.85-95
    • /
    • 2018
  • In this research, a biofilter system equipped with a biofilter process and a humidifier composed of a fluidized aerobic and an anoxic reactor, was constructed to treat odorous waste air containing hydrogen sulfide, ammonia and VOC, frequently generated from pig and poultry housing facilities, compost manufacturing factories and publicly owned facilities. Its optimum operating condition was revealed and discussed. In the experiment of complex feed, the ammonia of fed-waste air was removed by ca. 75% and more than 20% at the stage of the humidifier and the biofilter, respectively. The toluene of the fed-waste air was removed by ca. 20% and more than 70% at the stage of the humidifier and the biofilter, respectively. Therefore the water-soluble ammonia and the water-insoluble toluene were treated mainly at the stage of the humidifier and the biofilter, respectively. In addition, hydrogen sulfide was almost absorbed at the stage of the humidifier so that it was not detected at the biofilter process. In the experiment of ammonia-containing feed, the ammonia of fed-waste air was removed by ca. 65% and 35% at the stage of the humidifier and the biofilter, respectively. Its removal efficiency of ammonia at the stage of the humidifier was 10% less than that in the experiment of complex feed, due to no supply of such carbon source as toluene required in the process of denitrification. In the experiments of complex feed, ammonia-containing feed with and without (instead, glucose) the addition of yeast extract, the absorption rates of ammonia-nitrogen were ca. 0.28 mg/min, 0.23 mg/min and 0.27 mg/min, respectively. The corresponding denitrification rates in the anoxic reactor were 0.42 mg/min, 0.55 mg/min and 0.27 mg/min, respectively. In addition, in the modeling of bubble column(the fluidized aerobic reactor of the humidifier) process, the value of specific surface area(a) of bubbles multiplied by enhanced mass transfer coefficient (E $K_y$) was evaluated to be 0.12/hr.

Studies on the Biological Effects of Chemosterilant, Hempa, on the Rice Weevil (Sitophilus oryzae 1.) and Transmission of Sterility (화학적 불임유기물질 Hempa가 쌀바구미(Sitophilus oryzae L.)에 미치는 생물학적 영향 및 불임성의 전달에 관한 연구)

  • Shim Jai Wook
    • Korean journal of applied entomology
    • /
    • v.12 no.1
    • /
    • pp.1-21
    • /
    • 1973
  • Some experiments were conducted to investigate the effects of the chemosterilant, hempa, on the biology of the rice weevil, Sitophilus oryzae L., and the transmission of the lethal factors in the progeny. One to three days old adult males were fed on the wheat grains treated with concentrations of 0.0625, 0.125, 0.25, and $0.5\%$ of hempa water solution. The effects of the treatment on the mortality, longevity, and the performance of oviposition were examined for the Pl generation, and the hatchability and mortality in the postembryonic development were also tested in the $F_1,\;F_2,\;BC_1,\;F_3,\;and\;BC_2$ generations to analyze the inheritance of the lethal factors. The results obtained were summarized as follows. (1) The average longevity of the treated males were ranged from 26.6 to 30.4 days, and indicated no statistical differences. (2) The mortality of the treated males were ranged between $3.3\%\;and\;13.3\%$ and showed no statistical significance. (3) The overall mean number of eggs laid by a female mated to a treated male with concentrations of 0.0625, 0.125, 0.26 and $0.5\%$ were 3.78, 4.05, 3.75 and 3.61 for the respective treatments, and they were not differ significantly from those of control which were 3.60 per female per 3 day period. The unmated female laid 1.91 in the same period, and significantly differ from those in other experimental groups. (4) The overall mean hatchability of the eggs laid by the females mated with males that had been treated with various concentrations of hempa were 86.82, 64.77, 53.47, 40.33 and $24.78\%$ for the respective concentrations of 0, 0.0625, 0.125, 0.25 and $0.5\%$. The hatchability decreased with the increasing concentrations. (5) The minimum hatchabilities were obtained from the eggs laid in the period of 10-12 days after treatment, then the hatchability increased showing some recovery. The recovery seemed to be very much delayed for the males which had been treated with the greater concentrations. Such a difference in hatchability might be related with the sensitivity of the developmental stages of the sperms, and broader spectrum in the stages and severer effects seemed to be associated with the increased concentrations. (6) The overall mean of larval mortality in the $F_l$ generation were 6.55, 17.89, 27.40, 35.42 and $52.17\%$ for the respective concentrations of 0,0.0625, 0.125,0.25 and $0.5\%$. And there was a tendency to increase in the mortality with the increase of concentrations. (7) The correlation coefficients between per cent sterile eggs and larval mortality for the experimental plots of 0.125, 0.25 and $0.5\%$ treatments showed r=+0.83 and +0.85, respectively, and it seemed to be close correlation between the lethal effects on the embryonic and post-embryonic developments. (8) Since the $SC_{50}$ of the sterile eggs was $0.133\%$ and $SC_{50}$ of the larval mortality was $0.565\%$, it was considered that tile lethal factors expressed more in the egg stages than the larval stages. (9) The ratio of female to male in the $F_l$ adults showed 100 : 125, 100 : 108 and 100 : 124 for the plots of 0.125, 0.25 and $0.5\%$ treatments, respectively. And it n·as considered that the sex ratio distortions might occur with the higher concentrations. (10) When the F, males originated 1.on the eggs had been laid by p, in the period of 16-18 days after treatment, were crossed to normal females $(BC_1)$ and made sib matings $(F_2)$, the per cent sterile eggs of the $BC_1$ generation were 13.88 and $33.04\%$ , and were 31.01 and $38.73\%$ for the $F_2$generation with the plots of 0.0625 and $0.125\%$ treatment, respectively. And these seemed to be a results of the $F_1$ individuals are carrying some chromosomal aberrations (11) The larval mortality was the highest in the $F_2$ plot and followed the female backcross plot, and the least in the male backcrosses. (12) The proportions of 1st and 2nd instar larvae among the larval development at tile 17th day after oviposition were 10.98, 27.26, 32.98 and $15.73\%$ in the normal female $\times$ normal male, $F_1$ female$\times$normal male, normal $female \;\times F_1$ male and $female \;\times F_1$ male plots, respectively. It was considered that the larval development might be delayed by the treatment in the 2nd generation. (13) Per cent larval mortality and sterile eggs were greater in the $F_2$ sib mating plots $(F_3)$ than both of $F_2$ backcrosses. Therefore, it seemed that some of the recessive lethal mutations might affect in the further generations. (14) The sterility, induced by the treatment of chemosterilant, hempa, was considered as the result of the dominant lethal mutations due to chromosomal aberrations such as translocation and/or deletion. The effects of these lethal factors seemed to be inherited tip to 3rd generation after treatment.

  • PDF