• Title/Summary/Keyword: 문제집

Search Result 998, Processing Time 0.023 seconds

A COMPARATIVE STUDY OF PARENTAL REARING BEHAVIORS BETWEEN CONDUCT DISORDER AND NORMAL ADOLESCENTS (청소년 품행장애와 부모양육행동과의 관계에 대한 연구)

  • Kim, Kyung-Bin;Lee, Jong-Il;Jhin, Hea-Kyung
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.9 no.1
    • /
    • pp.67-81
    • /
    • 1998
  • Objective:There is increasing interest in the developmental relationship of parental psychopathology and parenting behavior and conduct disorder in adolescence. The object of this study is to investigate the role of parental rearing behaviors in influencing conduct disorder in adolescence comparing with normal adolescents. Methods:The author assessed 52 conduct disorder who met the DSM-Ⅳ criteria, and 144 normal control subjects using self-report questionnaires, 'The Parental Rearing Behavior Scale'. Results:The results of study were as follows:1) There is significant correlation between the conduct disorder group and the control group in the father’s anxious emotion subscale, not mother’s. 2) There is no significant correlation between the conduct Disorder group and the control group in other subscales such as affection, hostility, rational guideline and consistent limitation subscales. Conclusion:The results suggest that father’s psychopathology including overanxious parenting style will predispose a risk factor for conduct disorder than mother’s psychopathology.

  • PDF

Test and Analysis on the Transverse Gusset Plate Connection to Circular Hollow Section(CHS) of High Strength (고강도 원형강관의 직각방향 거셋플레이트 접합부 실험 및 해석)

  • Lee, Swoo-Heon;Shin, Kyung-Jae;Lee, Hee-Du;Kim, Woo-Bum
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.2
    • /
    • pp.163-173
    • /
    • 2012
  • A connection composed of a circular hollow structural section (HSS) has complicated details, and exhibits a very complex local deformation when it reaches the yield stress. Given these circumstances, proposing a simple design equation considering local deformation is difficult. The design equations of the Korea Building Code (KBC 2009) for HSS joints are simple and are very similar to those of the AISC. These design equations limit the maximum yield stress up to 360MPa and yield ratio (yield strength/tensile strength) up to 0.8. This means that the material with yield strength exceeding 360MPa could be used after verification based on the test or rational analysis for the similar connection. This paper introduces an experimental program and finite element analysis (FEA) for the circular hollow section (CHS) with a transverse gusset plate made of high-strength steel (HSB600) or structural steel (SS400) when the joints are subjected to lateral force. Comparison of the design equations with the results of FEA and test may be used for the modification of the design equations.

Evaluation of the Structural Performance of Tetragonal Lattice Girders (사각 격자지보의 구조 성능 평가)

  • Kim, Seung-Jun;Han, Keum-Ho;Won, Deok-Hee;Baek, Jung-Sik;Kang, Young-Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.3
    • /
    • pp.267-278
    • /
    • 2012
  • In general, the H-shaped steel ribs or triangular lattice girders have been mostly used in constructing tunnels through the NATM construction method. The H-shaped steel rib has higher flexural and axial strength than the triangular lattice girder, but many unexpected gaps can occur in the concrete lining system after shotcreting if the H-shaped steel rib is used as the support system. To achieve better shotcreting quality, the triangular lattice girder was developed. However, in general, the triangle lattice girder has low flexural and axial strength. Likewise, the triangular lattice girder, which has circular sectional members, has so many fractures from welded points at the joints between the members. Finally, the new type of tetragonal lattice girder was developed to overcome those problems. In this study, the structural performance of the tetragonal lattice girders was evaluated through analytical and experimental studies. In the analytical studies, the four-point bending analysis, the traditional evaluation method to determine the flexural strength of the lattice girder, was performed. Moreover, the linear-elastic analysis and stability analysis of the arch structure made by the lattice girders were performed to measure structural performance. Experiments were likewise performed to compare the structural performances of the tetragonal girder with traditional triangular lattice girders.

Flexural Tensile Strength of CJP Groove Welded Joints Connecting Thick HSA800 Plates (HSA800 후판재의 완전용입 맞댐용접부 휨-인장강도 실험)

  • Lee, Cheol Ho;Kim, Dae Kyung;Han, Kyu Hong;Park, Chang Hee;Kim, Jin Ho;Lee, Seung Eun;Kim, Do Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.5
    • /
    • pp.407-418
    • /
    • 2014
  • As a continuing work of previously conducted standard tension tests, full-scale flexural tests were conducted in this study to assess the structural performance the CJP groove welded joints connecting thick HSA800 plates. Two welding electrodes were available at the time of this experimental research; one was GMAW-based electrode A and the other FCAW-based electrode B. Three full-scale box-type beam specimens with single bevel- and V-groove CJP welded joints were fabricated from 60mm and 25mm thick HSA800 plates according to the AWS-prequalified groove welded joint details. In designing the specimens, all possible limit states like local and lateral torsional buckling were carefully controlled in order to induce flexural plastic yielding or eventual joint fracture. All the CJP joints made by both welding electrodes showed satisfactory performance and were able to transfer the tensile flange forces higher than that corresponding to the measured tensile strength of HSA800 flange plates. However, it should be noted that, during fabrication, serious concerns about the welding efficiency and workability of the GMAW-based electrode were raised by a certified welder. The fracture occurred at the unbeveled (or vertical) interface between the weldment and the base metal when the GMAW-based electrode was used in the single-bevel joint, implying the possibility of insufficient melting. Thus, the FCAW-based electrode B is again recommended as the choice of welding electrode for HSA800 plates. The limited test data of this study implies that the V-groove CJP joint should be used in favor of the single bevel CJP joint, if possible.

Effects of Composite Floor Slab on Seismic Performance of Welded Steel Moment Connections (철골모멘트 용접접합부의 내진성능에 미치는 합성슬래브의 영향)

  • Lee, Cheol Ho;Jung, Jong Hyun;Kim, Jeong Jae
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.5
    • /
    • pp.385-396
    • /
    • 2014
  • Traditionally, domestic steel design and construction practice has provided extra shear studs to moment frame beams even when they are designed as non-composite beams. In the 1994 Northridge earthquake, connection damage initiated from the beam bottom flange side was prevalent. The upward moving of the neutral axis due to the composite action between steel beam and floor deck was speculated to be one of the critical causes. In this study, full-scale seismic testing was conducted to investigate the side effects of the composite action in steel seismic moment frames. The specimen PN700-C, designed following the domestic connection and floor deck details, exhibited significant upward shift of the neutral axis under sagging (or positive) moment, thus producing high strain demand on the bottom flange, and showed a poor seismic performance because of brittle fracture of the beam bottom flange at 3% story drift. The specimen DB700-C, designed by using RBS connection and with the details of minimized floor composite action, exhibited superior seismic performance, without experiencing any fracture or concrete crushing, almost identical to the bare steel counterpart (specimen DB700-NC). The results of this study clearly indicate that the beams and connections in seismic steel moment frames should be constructed to minimize the composite action of a floor deck if possible.

A Study for Unsaturated-Character of Weathered Granite Soil in Korea (국내 화강풍화토의 불포화 특성에 관한 연구)

  • Lee, Hyoungkyu;Lee, In
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.3
    • /
    • pp.13-20
    • /
    • 2009
  • Generally, soil is regarded as fully saturated in Geotechnical Engineering and under ground structure design. Because it is in convenience and safety. But soils treated in field are almost in unsaturated state. Design in unsaturated state is difficult comparing with saturated soil. In unsaturated soil mechanics, parameters are usually not constant unlike saturated soil mechanics. Additionally lab or field tests in unsaturated soil mechanics are required more cost, time and theoretical difficulty. One of essential requisites for examination about unsaturated soil is Soil-Water Characteristic Curve (SWCC). It show the relation between soil suction and soil water content. Through many studies in and out of country, computation and testing methods for SWCC were introduced. But in this the country, most soil is granite soil that is widely spread in Korea. And the studies for granite soil's SWCC are not enough yet. In this paper, through studying for existing proposal methods about computation SWCC and collection data for domestic granite soils, It was determined the suitable method for domestic granite soils, and computed each granite soil's SWCC. The purpose of this paper is establishing database for domestic granite soil's SWCC as each region to convenience for applying to actual affairs. For this, studying about existing proposal methods for SWCC was performed and a computer program Soil-Vision is used. Furthermore for verification theoretical and testing methods were also performed.

  • PDF

A Comparative Analysis on Physico-Chemical Characteristics of MSW (Municipal Solid Waste) from Dwelling Site and Landfill Site - A Case Study of the Chungju City - (생활폐기물의 발생원과 최종 매립장에서 물리화학적 특성 비교 분석 - 충주시를 중심으로 -)

  • Cho, Byungyeol;Yeon, Ikjun;Lee, Byungchan
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.3
    • /
    • pp.47-52
    • /
    • 2009
  • The comparative analysis on physico-chemical characteristics of municipal solid waste from dwelling site and landfill site were performed to provide the fundamental information of waste management in Chungju city. It was analysed and evaluated the bulk density, physical component, three major component, chemical component, and heating value of MSW. The physical components depended on the sampling site in dwelling site and landfill site. But, by the ultimate analysis, the chemical composition was almost similar to result for municipal solid waste from dwelling site and landfill site. Therefore, it is necessary to investigate the physical components according to sampling site for the MBT to introduce for combustible municipal solid waste pre-treatment, but it needs the chemical composition from landfill site to design the incinerator. The physical composition showed that the combustible and the noncombustible occupied 87.4% and 12.6% respectively. In case of three component analysis, the moisture, the combustible, and the ash were 27.6, 60.5, 11.9% respectively. The chemical composition through the element analysis were C (50.1%), H (6%), O (39.5%), N (1.9%), S (0.5%), and Cl (1.3%).

  • PDF

Physicochemical Characteristics and Estimation of H2S Emission Rate from Municipal Solid Waste at the Environmental Facilities in Busan City (부산지역 환경기초시설에서 발생하는 폐기물의 물리, 화학적 특성 규명 및 황화수소 발생량 예측에 관한 연구)

  • Lee, Taeyoon;Kim, Doyong;Kim, Jaejin;Lee, Junki
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.2
    • /
    • pp.13-20
    • /
    • 2009
  • There have been increasing interests in the odor generation problems as concerns about the quality of life has been increased recently. Especially, approximately 67% of the odor complaints from environmental facilities are those from sewage treatment facilities and food waste treatment facilities. Moreover, sewage ocean dumping will be prohibited from 2012 by the international and domestic ocean laws, and thus, demand for alternative management plans is increasing. Therefore, it was first selected 5 sewage treatment facilities and 5 food waste treatment facilities where the amounts of waste are relatively immense in Busan, and collect their sludge samples. Then it was investigated the samples' physical and chemical characteristics through proximate analysis, elemental analysis, XRF analysis, and calorific value analysis. Finally, estimate the $H_2S$ emission rates were estimated in order to apply the results as the basic data for providing the fundamental solution for the oder complaints. As a result, the concentration of $H_2S$ in sewage sludge and in food waste treatment facility were 57.3 mg/kg and 19.7 mg/kg in average, respectively. Finally, the units of $H_2S$ in wastes stored in total 10 waste treatment facilities was estimated 16,017,910.0 mg/d.

  • PDF

Determination of Major Reduced Sulfur Gases Emitted from Wastes Stored in Environmental Facility Using GC/FPD (GC/FPD를 이용한 환경기초시설 폐기물의 대기중 황계열 악취물질 배출특성에 관한 연구)

  • Lee, Taeyoon;Lee, Jeakeun;Lee, Junki
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.2
    • /
    • pp.37-43
    • /
    • 2009
  • With the economic development of Korea, sewage treatment facilities and waste food treatment facilities have been steadily increased. These facilities have positive effects such as the conservation of the water resources quality and waste food recycling while they also affect the neighborhood life with severe odor problems. Therefore, it was first collected sludge samples from 5 sewage treatment facilities and 5 waste food treatment facilities where the amounts of waste produced from above sites are relatively immense in Busan and estimate the $H_2S$ emission rates. Then it was selected 1 sample which has the highest emission rate of $H_2S$. Using flux chamber and GC/FPD analyses, it was tried to quantify the emitted amount of sulfonic gas concentration under anoxic condition. The sludge sample obtained from Noksan sewage treatment facility has the highest emission rate of $H_2S$. This sample contained 156.18 mg/kg $H_2S$. The odor compounds were analyzed using GC/FPD and the concentrations were converted to odor quotient. Among odor compounds the ratio of $CH_3SH$ (methylmercaptan) for the total odor quotient was 47.3% and considered to be the main odor compound in the sample.

  • PDF

Correlation Analysis of Sewer Integrity and Ground Subsidence (하수관로 건전도와 도로함몰 발생 상관관계 분석)

  • Kim, Jinyoung;Kang, Jaemo;Choi, Changho;Park, Duhee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.6
    • /
    • pp.31-37
    • /
    • 2017
  • In recent years, the increasing trend of ground subsidence in major cities has caused social problems. Aged sewer pipeline as a main attribute for the subsidence is simply replaced and maintained according to a survey result with related to its buried period. However, other attributes and risk analysis for the subsidence have not been well studied yet. In this point, this study proposed various environmental and structural attributes with related to sewer pipelines and, then, a method of ground subsidence risk evaluation with a certain level of reliability. In order to find effective attributes to ground subsidence near to sewer, the nearest sewerage data were extracted at the location of subsidence in the City of Seoul, and a level of correlation was analyzed between subsidence and individual attribute. The effective weight factors for the proposed attributes was estimated through AHP analysis and its applicability was verified by comparing the actual subsidence data to the risk evaluation in the pilot study district of Seoul.