• Title/Summary/Keyword: 목재 시스템

Search Result 165, Processing Time 0.028 seconds

A Study on the Effect of Inflammable Materials on the Control Characteristics of Thermal and Smoke Fluid of Water Curtain System (가연성 물질에 따른 워터커튼 시스템의 열 및 연기유동 제어특성에 관한 연구)

  • You, Woo-Jun;Nam, Jun-Seok;Kim, Dong-Joon;Lee, Jeong-Kyoon;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.53-58
    • /
    • 2012
  • In this study fire control characteristics for inflammable materials of water curtain system are experimentally analyzed. Heat release rate for pinewood and gasoline was calculated using Room Corner Tester (RCT) and fire test apparatus for water curtain system is manufactured. Nozzles (180 degree of injection angle, 8.2 mm of orifice diameter) are installed at the nearby ceiling of place at 5 m distance from fire originate and temperature profile as well as transmission are obtained from the fire experiment of pinewood and gasoline in the water curtain system. Based on the results, parameters of engineering importance for fire control characteristics of water curtain system such as generation of high temperature smoke and thermal phenomena of fluid flow by injection nozzle are identified.

Pressure Drop of Integrated Hybrid System and Microbe-population Distribution of Biofilter-media (통합 하이브리드시스템의 압력강하 거동 및 바이오필터 담체의 미생물 population 분포)

  • Lee, Eun Ju;Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.60 no.1
    • /
    • pp.116-124
    • /
    • 2022
  • In this study, waste air containing ethanol and hydrogen sulfide, was treated by an integrated hybrid system composed of two alternatively-operating UV/photocatalytic reactor-process and biofilter processes of a biofilter system having two units with an improved design (R reactor) and a conventional biofilter (L reactor). Both a pressure drop (△p) per unit process of the integrated hybrid system and a microbe-population-distribution of each biofilter process were observed. The △p of the UV/photocatalytic reactor process turned out very negligible. The △p of the L reactor was observed to increase continuously to 4.0~5.0 mmH2O (i.e., 5.0~6.25 mmH2O/m). In case of R reactor, its △p showed the one below ca. 16~20% of the △p of the L reactor. Adopting such microbes-carrying biofilter media with high porosity as waste-tire crumb media, and the improved biofilter design, contributed to △p of this study, reduced by ca. 37~50% and 40~53%, respectively, from the reported △p of conventional biofilter packed with biofilter media of the mixture (50:50) of wood chip and wood bark. In addition, the △p of R reactor in this study, reduced by ca. 80% from the reported △p of conventional biofilter packed with biofilter media of the mixture (75:25) of scoria with high porosity and compost, was mainly attributed to adopting the improved biofilter design. On the other hand, in case of L reactor, the CFU counts in its lowest column was analyzed double as much as those in any other columns. However, in case of R reactor, its CFU counts were bigger by 50% than the one of L reactor and its microbes were evenly distributed at its higher and lower columns of Rdn reactor and Rup reactor. This phenomena was attributed to an even moisture distribution of 50~55% of R reactor at its higher and lower columns. Therefore, R reactor showed superb characteristics in terms of both △p and microbe-population-distribution, compared to L reactor.

An Analysis of the Operational Productivity and Cost for the Utilization of Forest-biomass(I) - the Operational time and Productivity - (산림바이오매스 이용을 위한 산림작업 공정 및 비용 분석(I) -작업시간 및 공정 -)

  • Mun, Ho-Seong;Cho, Koo-Hyun;Park, Sang-Jun
    • Journal of Korean Society of Forest Science
    • /
    • v.103 no.4
    • /
    • pp.583-592
    • /
    • 2014
  • This study was carried out to investigate the operational time and productivity of logging operation by chain saw, yarder attached on tractor, tower-yarder, mini-truck, mini-forwarder, and chipping operations by mini-chipper, large-chipper in order to develop the efficient logging operation system for utilization of forest-biomass. As a result, the average felling and bucking time using chain saw at the site 1 and 2 was observed to be 182.7 sec/cycle and 518.5 sec/cycle respectively. The average yarding time was 202.5 sec/cycle using yarder attached on tractor and 295.1 sec/cycle using tower-yarder. The average forwarding time was 2,073 sec/cycle using mini-truck and 2,248.4 sec/cycle using mini-forwarder. The operational time of felling and bucking using chain-saw can be delayed according to the direction of fallen trees. The selection of felling direction is very important to yarding operation because the direction between width-yarding and felling are interrelated. Productivity can be improved through educating and training operators in the yarding operations. Mini-forwarder is needed to use because of higher productivity and lower cost than mini-truck. The operational productivity of felling and bucking by chain saw was $66.96m^3/man{\cdot}day$ and $43.86m^3/man{\cdot}day$ at site 1 and 2 respectively. The yarding productivity was $5.68m^3/man{\cdot}day$ by yarder attached on tractor, $10.74m^3/man{\cdot}day$ by tower-yarder. The forwarding productivity was $21.29m^3/man{\cdot}day$ by mini-truck, $28.57m^3/man{\cdot}day$ by mini-forwarder. The chipping productivity was $4.42m^3/man{\cdot}day$ by mini-chipper, $21.87m^3/man{\cdot}day$ by large-chipper.

The Comparison of the Ultra-Violet Radiation of Summer Outdoor Screened by the Landscaping Shade Facilities and Tree (조경용 차양시설과 수목에 의한 하절기 옥외공간의 자외선 차단율 비교)

  • Lee, Chun-Seok;Ryu, Nam-Hyong
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.6
    • /
    • pp.20-28
    • /
    • 2013
  • The purpose of this study was to compare the ultra-violet(UV) radiation under the landscaping shade facilities and tree with natural solar UV of the outdoor space at summer middays. The UVA+B and UVB were recorded every minute from the $20^{th}$ of June to the $26^{th}$ of September 2012 at a height of 1.1m above in the four different shading conditions, with fours same measuring system consisting of two couple of analog UVA+B sensor(220~370nm, Genicom's GUVA-T21GH) and UVB sensor(220~320nm, Genicom's GUVA-T21GH) and data acquisition systems(Comfile Tech.'s Moacon). Four different shading conditions were under an wooden shelter($W4.2m{\times}L4.2m{\times}H2.5m$), a polyester membrane structure ($W4.9m{\times}L4.9m{\times}H2.6m$), a Salix koreensis($H11{\times}B30$), and a brick-paved plot without any shading material. Based on the 648 records of 17 sunny days, the time serial difference of natural solar UVA+B and UVB for midday periods were analysed and compared, and statistical analysis about the difference between the four shading conditions was done based on the 2,052 records of daytime period from 10 A.M. to 4 P.M.. The major findings were as follows; 1. The average UVA+B under the wooden shelter, the membrane and the tree were $39{\mu}W/cm^2$(3.4%), $74{\mu}W/cm^2$(6.4%), $87{\mu}W/cm^2$(7.6%) respectively, while the solar UVA+B was $1.148{\mu}W/cm^2$. Which means those facilities and tree screened at least 93% of solar UV+B. 2. The average UVB under the wooden shelter, the membrane and the tree were $12{\mu}W/cm^2$(5.8%), $26{\mu}W/cm^2$(13%), $17{\mu}W/cm^2$(8.2%) respectively, while the solar UVB was $207{\mu}W/cm^2$. The membrane showed the highest level and the wooden shelter lowest. 3. According to the results of time serial analysis, the difference between the three shaded conditions around noon was very small, but the differences of early morning and late afternoon were apparently big. Which seems caused by the matter of the formal and structural characteristics of the shading facilities and tree, not by the shading materials itself. In summary, the performance of the four landscaping shade facilities and tree were very good at screening the solar UV at outdoor of summer middays, but poor at screening the lateral UV during early morning and late afternoon. Therefore, it can be apparently said that the more delicate design of shading facilities and big tree or forest to block the additional lateral UV, the more effective in conditioning the outdoor space reducing the useless or even harmful radiation for human activities.

Partial Composite Action of Gypsum-Sheathed Cold-Formed Steel Wall Stud Panels (석고보드와 결합된 강재 샛기둥 패널의 부분 합성거동)

  • Lee, Young Ki
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.4
    • /
    • pp.373-380
    • /
    • 2001
  • The problem addressed in this study is how to analytically treat the partial composite action for wall panels. An equation, derived for wood-joist floor systems, which determines deflections for beams with partial composite action is introduced. The equation is applied to the calculation of the mid-span deflection for gypsum-sheathed, cold-formed steel was stud panels. The objective of this study is to properly reflect the influence of the following factors in the calculation of mid-span deflection for the panel: connection slip, local buckling, perforations in the stud web, and effects from joints in the sheathing. Predicted deflections based on an upper bound for connection rigidity were closest to experimental deflections.

  • PDF

A Study on Cycle and Flow Analysis for Improvement of Energy Efficiency of a Heat Pump Dryer with Hot Bypass Gas and Air Dampers During Warm-up Stage (고온 우회가스 및 에어댐퍼 사용을 통한 히트펌프 건조기 승온단계 에너지 효율 향상을 위한 사이클 및 유동해석 연구)

  • Park, Sang-Jun;Hwang, Il-Sun;Lee, Young-Lim
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.3827-3834
    • /
    • 2012
  • Recently, instead of hot air type dryers that require a lot of heat, energy-efficient heat pump dryers have been used in various fields such as paper, textile, wood, food, etc. In this paper, the characteristics of heat pump cycle were theoretically evaluated with hot-gas bypass system to further improve the energy efficiency by minimizing the use of electric heaters in early warm-up stage of the dryers for frozen agricultural products. In addition, damper system that leads outside air to flow into the dryer were optimized to obtain extra heat for higher energy efficiency.

Fire Safety Administration Way of Tradition Buddhist Temple Cultural Heritage (전통사찰 문화재의 화재안전 관리방안에 관한 고찰)

  • Shin, Min-Seob;Kong, Ha-Sung
    • Journal of Conservation Science
    • /
    • v.23
    • /
    • pp.119-124
    • /
    • 2008
  • Have difficult controversial point to suppress fire effectively by geographical special quality that fire is transmitted and is during the mountain with the fast speed if our country's tradition Buddhist temple makes of most wood and most of construction structure of country importance tradition Buddhist temple are ignited once because combustibility is high as wood. By fire safety supervision improvement way of tradition Buddhist temple cultural heritage in this treatise law and systematic side, Side that is construction room robbers, disaster and prevention of disasters basis system construction and stream tube engine combination check, training courtesy call activity reinforcement present.

  • PDF

Review of Intermodal System of AGT and Bus (AGT와 버스의 혼용시스템에 대한 고찰)

  • MOK Jai Kyun;Chang Se Ky;Yoon Hee Taek;Woo Yoon Seuk
    • Proceedings of the KSR Conference
    • /
    • 2003.10b
    • /
    • pp.58-63
    • /
    • 2003
  • This study shows the functional contribution into the public transportation system for congestion area. And there is a introduction for the rapid bus transit developed in Europe community. It can be classified the public transportation as urban transit, subway and bus. For a few years, it has been introduced the AGT system as a role of the alternative and lengthening system of subway line. Recently, there is going on construction of AGT system in some regional cities. The AGT system has advantages in terms of accessibility and cost-effective rather than subway. But the bus system is advantageous at the points rather than AGT system. It is obvious that the bus system is most cost-effective for infrastructure and system rather than any other public transports. If the bus system has punctuality and precise docking, that becomes best choice for public transportation scheme. There are tries to develop new systems by means of the f1les up the advantages in bus and AGT system, which can be classified as BRT(Bus Rapid Transit}. The idea is simple; 'Thirik rail, use advanced buses.' It is introduced the IRISBUS system at this article, which was developed in Europe community. And it is introduced the project architecture to develop the similar system to IRISBUS in KRRI through National Transportation Key Technology R&D Project

  • PDF

A Simulation Study of the Performance of a Propulsion Equipment for Bimodal Tram (바이모달 트램의 추진장치 성능 모의)

  • Bae, Chang-Han;Mok, Jai-Kyun;Chang, Se-Ky;Lee, Kang-Won
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.1
    • /
    • pp.122-128
    • /
    • 2009
  • A bimodal low-floor tram is designed to provide the flexibility of bus and the punctuality of trains together to the passengers. The propulsion equipment of the bimodal tram is a series hybrid type using a set of CNG engine generator and Li-polymer battery. The present paper describes the specifications of the propulsion system in the bimodal tram which was drawn by a desirable driving cycle. In addition, it shows how the propulsion system of the bimodal tram can be controlled. With using a computer simulation tool of hybrid vehicles, ADVISOR, the performance of the bimodal tram was verified.

Thermal Performance Analysis of Renewable Hybrid heat Supply System for Zero Carbon Green Home of Apartment (공동주택의 제로카본 그린홈을 위한 신재생에너지 하이브리드 열공급 시스템의 열성능 분석)

  • Joo, Hong-Jin;Lee, Kyoung-Ho;Kwak, Hee-Youl
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.451-456
    • /
    • 2012
  • This study was carried out to evaluate thermal performance of the renewable hybrid heat supply system with solar thermal system and wood pellet boiler for Zero Carbon Green home of apartment houses. The hybrid heat supply system was set up at Korea Institute Energy Research in 2011. The system was comprised of the wood pellet boiler unit with heat capacity designed as 20,000 kacal/hr, a evacuated tubular solar collector 3.74 $m^2$ of aperture area at the $20^{\circ}$ install angle, a 0.3 $m^3$ hot water storage tank, a 0.15 $m^3$ hot water storage tank for space heating. Thermal performance tests for one-house of apartment house were carried out by hot water load and heating load in winter season through the hybrid heat supply system. As a result, hot water energy supplied by the hybrid heat supply system was 11kWh in a day. Solar thermal energy portion was 2.99kWh which is 27% of the total hot water energy supply. wood pellet boiler supply portion was 8.017kWh which is 73% of the total hot water energy supply.

  • PDF