• Title/Summary/Keyword: 모르타르 성능

Search Result 361, Processing Time 0.026 seconds

An Experimental Study on the Performance Evaluation of Repair Method of RC Structure Using Fire Resistance Engineered Cementitious Composites(FR-ECC) (고인성 내화·보수 모르타르를 활용한 RC구조물 보수공법의 성능평가에 관한 실험적 연구)

  • Kim, Jeong-Hee;Kim, Jae-Whan;Park, Sun-Gyu;Kwon, Young-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.6 s.58
    • /
    • pp.88-96
    • /
    • 2009
  • In this Study, FR-ECC(Fire Resistance Engineered Cementitious Composites) in which at same time it can improve the endurance and fire-resistance efficiency of a Structure was developed, and the experimental study such as thermal characteristic, Fire-resistance efficiency, and etc was performed for using FR-ECC as the repair materials for building and civil Structure. Moreover, it was evaluated about the field applicability of FR-ECC. As a result, FR-ECC is superior to the existence fire resistance repair mortar in strength and durability property. Also, FR-ECC was exposed to have the characteristic of being excellent than existence fire resistance mortar in the field applicability.

Evaluation on the Sulfate Attack Resistance of Cement Mortars with Different Exposure Conditions (노출조건에 따른 시멘트 모르타르의 황산염침식 저항성 평가)

  • Lee, Seung Tae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.6A
    • /
    • pp.427-435
    • /
    • 2012
  • In order to evaluate the effects of exposure conditions on the resistance to sulfate attack of normal and blended cement mortars, several mechanical characteristics of the mortars such as expansion, strength and bulk density were regularly monitored for 52 cycles under sodium sulfate attack. The mortar specimens were exposed to 3 different types of exposure conditions; 1) continuous full immersion(Exposure A), continuous half-immersion(Exposure B) and cyclic wetting-drying(Exposure C). Experimental results indicated that the maximum deterioration was noted in OPC mortar specimens subjected to Exposure B, showing the wide cracks in the portions where attacking solution is adjacent to air. Additionally, the beneficial effect of ground granulated blast-furnace slag and silica fume was clearly observed showing a superior resistance against sodium sulfate attack, because of its lower permeability and densified structure. Thus, it is suggested that when concrete made with normal cement is exposed to sulfate environment, proper considerations on the exposure conditions should be taken.

Analysis of Heat-generating Performance, Flexural Strength and Microstructure of Conductive Mortar Mixed with Micro Steel Fiber and MWCNT (마이크로 강섬유와 MWCNT를 혼입한 전도성 모르타르의 발열성능, 휨강도 및 미세구조 분석 )

  • Beom-gyun Choi;Gwang-hee Heo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.3
    • /
    • pp.47-58
    • /
    • 2024
  • This study were conduced experimentally to analyze the heat-generating performance, flexural strength, and microstructure of conductive mortar mixed with micro steel fiber and multi-wall carbon nanotube (MWCNT). In the conductive mortar heat-generating performance and flexural strength tests, the mixing concentration of MWCNT was selected as 0.0wt%, 0.5wt%, and 1.0wt% relative to the weight of cement, and micro steel fibers were mixed at 2.0vol% relative to the volume. The performance experiments were conducted with various applied voltages (DC 10V, 30V, 60V) and different electrode spacings (40 mm, 120 mm) as parameters, and the flexural strength was measured at the curing age of 28 days and compared and analyzed with the normal mortar. Furthermore, the surface shape and microstructure of conductive mortar were analyzed using a field emission scanning electron microscope (FE-SEM). The results showed that the heat-generating performance improved as the mixing concentration of MWCNT and the applied voltage increased, and it further improved as the electrode spacing became narrower. However, even if the mixing concentration of MWCNT was added up to 1.0 wt%, the heat-generating performance was not significantly improved. As a result of the flexural strength test, the average flexural strength of all specimens except the PM specimen and the MWCNT mixed specimens was 4.5 MPa or more, showing high flexural strength due to the incorporation of micro steel fibers. Through FE-SEM image analysis, Through FE-SEM image analysis, it was confirmed that a conductive network was formed between micro steel fibers and MWCNT particles in the cement matrix.

Fundamental Study on Improvement of Fire-Resistance and Field Application of Refractory Mortar of Tunnel Structures (터널의 내화성능 향상 및 내화모르타르 현장적용을 위한 기초 연구)

  • Kim, Min-Jeong;Kim, Dong-Jin;Lee, Sang-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.537-540
    • /
    • 2008
  • Tunnel structures are constructed even longer and more extensive these days than they were in the past. Because of this reason, breaking out a large scale of fire in tunnel structures is frequently. Recently, a noticeable event is reported that the temperature of inside of tunnel rises significantly when an oil car detonated in the tunnel and it reached 1,350$^{\circ}$C. It did damage to people who used the tunnel at that time and caused many demaged parts of tunnel to recover. To improve a fire resistance of tunnel, many methods are studied focused refractory concrete and mortar. This study deals with refractory mortar and is a part of initial basic step. In this study mechanical properties are considered before fire resistance test. As result of test for examination of mechanical properties, it is considered that a consistency and strength of refractory mortar in this study are suitable to construct.

  • PDF

Seismic Performance Evaluation of Reinforced Concrete Columns by Applying Steel Fiber-Reinforced Mortar at Plastic Hinge Region (소성힌지부 강섬유 혼입 모르타르 적용 철근콘크리트 기둥의 내진성능평가)

  • Cho, Chang-Geun;Han, Sung-Jin;Kwon, Min-Ho;Lim, Cheong-Kweon
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.3
    • /
    • pp.241-248
    • /
    • 2012
  • This paper presents a reinforced concrete composite column method in order to improve seismic performance of reinforced concrete column specimens by selectively applying steel fiber-reinforced mortars at the column plastic hinge region. In order to evaluate seismic improvement of the newly developed column method, a series of cyclic load test of column specimens under a constant axial load was investigated by manufacturing three specimens, two reinforced concrete composite columns by applying steel fiber-reinforced mortars at the column plastic hinge region and one conventional reinforced concrete column. Both concrete and steel fiber-reinforced mortar was cast-in placed type. From cyclic load test, it was found that the newly developed steel fiber-reinforced columns showed improved seismic performances than conventional reinforced concrete column in controlling bending and shear cracks as well as improving seismic lateral load-carrying capacities and lateral deformation capacities.

Evaluation of Fire Resistance Performance of Polymer Modified Cement Mortar Using Polypropylene Fiber (폴리프로필렌 섬유를 혼입한 폴리머 시멘트 모르타르의 내화성능 평가)

  • Jeon, Ki-Soo;Sim, Sang-Rak;Lee, Young-Do
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.2
    • /
    • pp.133-142
    • /
    • 2023
  • In this study, the fire resistance capabilities of polypropylene fiber-reinforced polymer-modified cement mortar were assessed to guarantee the fire resistance fo this materials, commonly employed in the repair of concrete structures. Experimental outcomes revealed that an increased water and polymer content heightened the likelihood of spalling, while longer polypropylene fibers and elevated polymer concentrations proved more effective in mitigating spalling.

Pullout capacity Evaluation of anchor and anchor system development to prevent release of anchors in expansion joint (신축이음장치의 앵커 인발성능 평가 및 나사 풀림 방지를 위한 앵커시스템 개발)

  • Ha, Sang-Su
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.1
    • /
    • pp.65-72
    • /
    • 2010
  • The failure of expansion joints for bridges generally occurs in non-shrinkage mortar another problem is the release of anchors in expansion joints due to the impact and vibration that occurs when cars are driving over a bridge. In this study, to overcome the failure of expansion joints that is related to the failure of non-shrinkage mortar, an elastomeric mortar has been developed. The elastomeric mortar has a highly developed pull-out capacity compared with that of non-shrinkage mortar. Moreover, an anchor system that can be changed easily and prevent the fracture of expansion joints has been developed.

A Study on The Air Pollution Reduction Performance of Mortar Coated with Photocatalyst (광촉매를 코팅한 모르타르의 미세먼지 저감 성능 연구)

  • Seung-Jin Lee;Min-Ki Jeon;Seung-Tae Jeong;In-Hwan Yang
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.12 no.1
    • /
    • pp.94-101
    • /
    • 2024
  • In this paper, the performance of air pollution reduction by coating the photocatalyst solution on the mortar surface was analyzed to ensure the possibility of applying the photocatalyst to structures with a large specific surface area. The photocatalytic concentrations of the coating solution were set to 1.5 % and 3.0 %, and the types of binders were considered as experimental variables, such as ultra-high performance concrete (UHPC), ordinary portland cement (OPC), and blast furnace slag. As the photocatalyst concentration increases, the air pollution reduction performance increases. In addition, as a result of the air pollution reduction performance, the NOx concentration reduction rate was the highest for UHPC, and the air pollution reduction performance increased as the blast furnace slag was replaced. Therefore, the amount of TiO2 remaining on the surface varies depending on the density of the tissue due to the difference in particles caused by the difference in the amount of TiO2 remaining on the surface.

Evaluation on Performance of Repair Mortar Used for Pre-wetting Spray Method (프리웨팅 스프레이 공법용 모르타르의 성능평가)

  • Nam, Yong-Hyuk;Chung, Young-Jun;Jang, Suk-Hwan;An, Young-Ki;Kim, Sung Chil
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.4
    • /
    • pp.235-242
    • /
    • 2005
  • This study is on the evaluation of performance of polymer cement mortar which is used for pre-wetting spray method. Pre-wetting spray method is an epoch-making method to repair concrete structures damaged, which is added a small quantity water preciously to dry mortar to reduce dust and rebound and spray mortar mixed with fixed quantity water at nozzle before spray. The result showed that physical performance such like compressive, flexural and adhesive strength of polymer cement mortar, TS 100 used for pre-wetting spray method was superior to other repair mortar. Also durable performance such as resistance on permeability of chloride ion, carbonation, chemical and freezing-thawing was excellent.

Evaluation of Crack Resistant Performance in Cement Mortar with Steel Fiber and CSA Expansion Admixture (CSA 팽창재를 혼입한 강섬유 보강 모르타르의 균열 저항성능 평가)

  • Ahn, Jung-Kil;Park, Ki-Tae;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.125-132
    • /
    • 2014
  • Steel fiber is a effective composite for crack resistance and improve structural performance under tensile loading. This study presents an evaluation of crack resistance and structural performance in cement mortar with steel fiber and expansion agent through internal chemical prestressing. For this work, cement mortar samples with 10% replacement of cement binder with CSA (Calcium-Sulfo-Aluminate) expansion agent and 1% volume ratio of steel fiber are prepared. Including basic mechanical properties, initial cracking load and fracture energy are evaluated in cement mortar beam with notch. Initial cracking load and fracture energy in cement mortar with CSA and steel fiber increase by 1.75 and 1.41~1.53 times compared with those in cement mortar with steel fiber. With optimum mix design for steel fiber and CSA expansive agent, the composite with chemical prestressing can be applied to various members and effectively improve crack resistance to external loading.