• Title/Summary/Keyword: 모드 선택기

Search Result 168, Processing Time 0.022 seconds

A Study on the Construction method to improve the fuzzy controllers using language variable and coefficient selecting method (언어변수 및 계수선택방법을 이용한 퍼지제어기 설계에 관한 연구)

  • 박승용;변기녕;황종학;김흥수
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2000.05a
    • /
    • pp.125-134
    • /
    • 2000
  • In this paper, we proposed a new circuit construction method that reduced the number of CMOS devices of singleton fuzzy controller(SFC) through the proposing a new membership function circuit(MFC) which uses the language variable selecting and the coefficient selecting circuit. According to the range of input values, we can choose the language variables beforehand which will be used in the inference. So we proposed the new MFC which generates the only necessary language variables. Also, we removed all rules of which adapting degree of their antecedents is zero through proposing the coefficient selecting circuit which beforehand selects the coefficients which will influence the inference result. Though this method, we simplified the structure of SFC and reduced the size of hardware. And to solve the problem in the current mode with respect to the restriction of the fan-out number, voltage-input and current-out membership function circuits are constituted of operational transconductance amplifiers. A membership function circuit which includes the language variable selecting circuit, a minimum operation circuit we implemented by current mode CMOS devices. As a result of applying proposed method, total numbers of blocks and devices wave decreased. If the number of variables and antecedents are getting larger, this method is more efficient.

  • PDF

A Study on the Construction method to improve the fuzzy controllers using language variable and coefficient selecting method (언어변수 및 계수선택방법을 이용한 퍼지제어기 설계에 관한 연구)

  • 박승용;변기녕;황종학;김흥수
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2000.11a
    • /
    • pp.357-365
    • /
    • 2000
  • In this paper, we proposed a new circuit construction method that reduced the number of CMOS devices of singleton fuzzy controller(SFC) through the proposing a new membership function circuit(MFC) which uses the language variable selecting and the coefficient selecting circuit. According to the range of input values, we can choose the language variables beforehand which will be used in the inference. So we proposed the new MFC which generates the only necessary language variables. Also, we removed all rules of which adapting degree of their antecedents is zero through proposing the coefficient selecting circuit which beforehand selects the coefficients which will influence the inference result. Though this method, we simplified the structure of SFC and reduced the size of hardware. And to solve the problem in the current mode with respect to the restriction of the fan-out number, voltage-input and current-out membership function circuits are constituted of operational transconductance amplifiers. A membership function circuit which includes the language variable selecting circuit, a minimum operation circuit we implemented by current mode CMOS devices. As a result of applying proposed method, total numbers of blocks and devices wave decreased. If the number of variables and antecedents are getting larger, this method is more efficient.

  • PDF

Development of an Externally Amplitude-and-Delay Equalized Narrow-Bandpass Filter for the Engineering Model Level Ka-band Input Demultiplexer (Engineering Model 급 Ka 대역 입력 Demultiplexer 용의 진폭 및 군지연 등화된 협대역 여파기의 개발)

  • 강승택;엄만석;이주섭;염인복;이성팔
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2002.11a
    • /
    • pp.347-351
    • /
    • 2002
  • 본 논문에서는, 위성 중계기 Engineering Model(EM)급 Ka 대역 입력 Demultiplexer (IMUX)의 진폭 및 군지연 등화된 채널 협대역 여파기의 개발/결과가 제시된다. 여파기는 큰 선택성(selectivity)과 작은 대역내 손실로써 동작하기 위해, 8차의 타원적분형 응답특성의 이중모드 결합구조의 특성을 가진다. 그리고 여파기 출력이 가지는 급한 변화의 군지연과 대역내 진폭은 2극(Pole) 등화기에 의해 평탄하게 된다. 튜닝 및 측정 결과는 요구규격사항을 잘 만족함을 보여준다.

  • PDF

High-sensitivity temperature sensor using the side polished single mode fiber and polymer planar waveguide coupler (측면연마된 단일모드 광섬유와 폴리머 평면도파로 결합기를 이용한 고감도 온도센서)

  • Jeong, Ung-Gyu;Kim, Sang-U;Kim, Gwang-Taek;Kim, Eung-Su;Yu, Yun-Sik;Gang, Sin-Won
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.1
    • /
    • pp.39-46
    • /
    • 2002
  • High-senstivity temperature sensor based on the wavelength selectivity of single mode fiber-to-planar waveguide coupler, was demonstrated. The resonant wavelength of the coupler was shifted with large rate of -3.43nm/$^{\circ}C$ owing to good thermo-optic effects of polymer planar waveguide. The device design technique to reduce the polarization dependent properties and increase the temperature sensitivity was presented.

Design of a Readout Circuit of Pulse Rate and Pulse Waveform for a U-Health System Using a Dual-Mode ADC (이중 모드 ADC를 이용한 U-Health 시스템용 맥박수와 맥박파형 검출 회로 설계)

  • Shin, Young-San;Wee, Jae-Kyung;Song, Inchae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.9
    • /
    • pp.68-73
    • /
    • 2013
  • In this paper, we proposed a readout circuit of pulse waveform and rate for a U-health system to monitor health condition. For long-time operation without replacing or charging a battery, either pulse waveform or pulse rate is selected as the output data of the proposed readout circuit according to health condition of a user. The proposed readout circuit consists of a simple digital logic discriminator and a dual-mode ADC which operates in the ADC mode or in the count mode. Firstly, the readout circuit counts pulse rate for 4 seconds in the count mode using the dual-mode ADC. Health condition is examined after the counted pulse rate is accumulated for 1 minute in the discriminator. If the pulse rate is out of the preset normal range, the dual-mode ADC operates in the ADC mode where pulse waveform is converted into 10-bit digital data with the sampling frequency of 1 kHz. These data are stored in a buffer and transmitted by 620 kbps to an external monitor through a RF transmitter. The data transmission period of the RF transmitter depends on the operation mode. It is generally 1 minute in the normal situation or 1 ms in the emergency situation. The proposed readout circuit was designed with $0.11{\mu}m$ process technology. The chip area is $460{\times}800{\mu}m^2$. According to measurement, the power consumption is $161.8{\mu}W$ in the count mode and $507.3{\mu}W$ in the ADC mode with the operating voltage of 1 V.

Experimental study on cooling performance characteristics of hybrid refrigeration system in a heavy duty vehicle (상용차 하이브리드 냉방시스템 냉방 성능 특성 연구)

  • Lee, Ho-Seong;Jeon, Hanbyeol;Kim, Jung-Il;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.419-425
    • /
    • 2019
  • The objective of this study was to investigate the cooling performance characteristics of a hybrid refrigeration system in a heavy duty vehicle. The tested hybrid refrigeration system had additionally an electric compressor besides the present mechanical compressor for selective use according to the operating conditions. The applied electric compressor was a scroll type and with 18.0 cc displacement. In order to analyze the performance characteristics of the hybrid refrigeration system with respect to the cooling capacity and Coefficient of Performance (COP), other components, including two different types of compressors, were installed and tested under various operating conditions such as compressor speed and air flow rate of the evaporator. When the electric compressor was operated at 4,500 rev/min, the cooling capacity was about 4.0kW and COP was 3.5. When the mechanical compressor was operated, whereas the cooling capacity was higher than the electric controlled compressor, COP was lower due to the larger displacement and higher power consumption. To analyze the hybrid system operating characteristics due to reasonable cooling capacity with electric compressor operation, the mechanical compressor and electric compressor were operated by turns every 10 minutes under certain system operating conditions. Because surge pressure occurred when both compressors were switched on, the operating strategy required some time to balance the system pressure.

Development of the Low Power Stand-Alone Smoke and Heat Detector for the Reliability Improvement (신뢰성 개선을 위한 저전력 열연 복합식 단독경보형 감지기 개발)

  • Jee, Seung-Wook;Kim, Si-Kuk;Lee, Jae-Jin;Kim, Pil-Young;Lee, Chun-Ha
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.74-79
    • /
    • 2012
  • This study is described for development of the stand-alone smoke and heat detector (SASHD) according to the revised in 2011 type approval and performance inspection code for detector. The main improvement of the revised regulation is source. CMOS microcontroller with nano watt technology is use for development of the workable SASHD over 10 years. The low-power SASHD is developed by using the power-saving sleep mode of microcontroller, by making the low-power source voltage checker, heat detector and smoke detector. The stand-alone detector is developed by smoke and heat detector type for reduce false fire alarm. User can choose type of work between the heat detection mode and smoke & heat detection mode. The SASHD can communicate with each them using RS-485 communication supported from microcontroller. So, this study can develop the SASHD that is able to alarm more wide area when fire occurs and reduce a flash fire alarm.

Implementation of Novel Bio-sensor Platform based on Optical Taper Coupler (광 테이퍼 결합기에 기초한 새로운 바이오-센서 플랫폼의 구현)

  • Kwang-Chun Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.5
    • /
    • pp.145-150
    • /
    • 2023
  • Non-uniform optical taper waveguides have been widely used as devices for high-efficiency mode coupling, as they are integrated with single-mode optical fibers or photonic crystal waveguides. In this paper, we present a new platform for chemical sensing and bio-sensing using optical taper waveguides with these characteristics. The principle of operation is based on the coupling efficiency and interference properties of optical directional coupler (DC) and multi-mode interference coupler (MMIC). First, the curvature characteristics of taper sections of DC and MMIC is explained, and the design specifications of optimized taper waveguide to increase waveguide sensitivity is selected. Next, the sensor response to the change in refractive index of sensing analyte is numerically analyzed. Numerical results show that as the length of couplers increases, the effective index per change in refractive index unit (RIU) of analyte increases, and that sensitivity can be tuned using taper DC and MMIC design techniques.

High Stability and High Efficiency Power Amplifier with Switchable Damper for Plasma Applications (플라즈마 응용을 위한 선택적 감쇠기를 사용한 고안정 고효율 전력증폭기)

  • Kim, Ji-Yeon;Lee, Dong-Heon;Chun, Sang-Hyun;Yoo, Ho-Joon;Kim, Jong-Heon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.1
    • /
    • pp.1-11
    • /
    • 2009
  • In this paper, a new 1 kW power amplifier with high efficiency and high stability in a RF generator is designed and fabricated for plasma applications. The efficiency of power amplifier is improved by using class-E amplifier that consists of one push-pull MOSFET and high current drive IC instead of class-C amplifier composed of several single ended MOSFET. Switchable damper that allows selecting three different modes of amplifiers for considering efficiency and stability is added into the amplifier for plasma applications. Stable region of an early electronic discharge section is extended to VSWR of 4.5:1 compared to conventional VSWR of 3.8:1 through using switchable damper. The dimension of the amplifier is also reduced to 30 % of conventional amplifier. The 80 % efficiency of power amplifier with switchable damper is obtained the output power of 1 kW in operating frequency of 13.56 MHz. In comparison of conventional power amplifier for plasma applications, 13 % efficiency is improved.

Microstrip Bandpass Filter Using of a T-Shaped Meander Loop Resonator (Microstrip Bandpass Filter을 이용한 향상된 T-Shaped Meander Loop 공진기)

  • 정주현;오인열;나극환
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2001.11a
    • /
    • pp.157-160
    • /
    • 2001
  • 본 논문에서 5.8GHz의 주파수 대역에서 사용할 수 있는 향상된 커플링 구조와 크기를 줄인 dual-mode microstrip bandpass filter를 설계하였다. 여기서 meander loop resonator를 쓰는 이유는 크기가 작고 방사 손실이 적으며 패턴이 간단하기 때문이다. 또한 이와 비슷한 특성을 갖는 ring, square patch, disk등은 불연속 성분을 가짐으로써 이중모드의 구현이 가능하다. 향상된 형태의 dual-mode microstrip bandpass filter의 변형된 T-shaped meander loop resonator를 소형으로 발전되고. 높은 선택도를 가지는 구조이다. 이 형태의 filter에서 150MHz의 bandwidth을 가지고 5.8GHz주파수를 가지는 구조로 설계하였다.

  • PDF