• Title/Summary/Keyword: 모델 제어

Search Result 5,472, Processing Time 0.04 seconds

T-S Fuzzy Formation Controlling Phugoid Model-Based Multi-Agent Systems in Discrete Time (이산시간에서의 장주기모델에 관한 다개체시스템의 T-S 퍼지 군집제어)

  • Moon, Ji Hyun;Lee, Jaejun;Lee, Ho Jae;Kim, Moon Hwan
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.4
    • /
    • pp.308-315
    • /
    • 2016
  • This paper addresses a formation control problem for a phugoid model-based multi-agent system in discrete time by using a Takagi-Sugeno (T-S) fuzzy model-based controller design technique. The concerned discrete-time model is obtained by Euler's method. A T-S fuzzy model is constructed through a feedback linearization. A fuzzy controller is then designed to stabilize the T-S fuzzy model. Design condition is presented in the linear matrix inequality format.

Design and Implementation of A UPnP Security Model (UPnP보안 모델의 설계 및 구현)

  • Lee Dong-Gun;Lim Kyeng-Sik;Park Kwang-Ro
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.1 no.2
    • /
    • pp.30-42
    • /
    • 2002
  • UPnP(Universal Plug and Play) is commercial product for the first time in home network middlewares, but it has problem that it has no security standards in UPnP specification. In this paper, we present UPnP security model. It is based on XML Signature of XML Security. It provides UPnP with secure services which are device control message authentication and user access level control. It is independent of UPnP modules and has mobility of secure service modules for non secure ability user part. We conclude this paper with an example of applying UPnP Security model to the UPnP audio device control and an test example.

  • PDF

Modeling of Distance Localization by Using an Extended Auditory Parallax Model (확장된 음향적 시차 모델을 이용한 음상 거리정위의 모델화)

  • 김해영
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.1
    • /
    • pp.30-39
    • /
    • 2004
  • This study aims at establishing a digital signal processing technique to control 3-D sound localization, especially focusing our ores on the role of information provided by Head-Related Transfer Function (HRTF). In order to clarify the cues to control the auditory distance perception, two conventional models named Hirsch-Tahara model and auditory parallax model were examined. As a result, it was shown that both models have limitations to universally explain the auditory distance perception. Hence, the auditory parallax model was extended so as to apply in broader cases of auditory distance perception. The results of the experiment by simulating HRTFs based on the extended parallax model showed that the cues provided by the new model were almost sufficient to control the perception of auditory distance from an actual sound source located within about 2m.

Experimental Study of System Identification for Seismic Response of Building Structure (건축구조물의 지진응답제어를 위한 시스템 식별의 실험적 연구)

  • 주석준;박지훈;민경원;홍성목
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.4
    • /
    • pp.47-60
    • /
    • 1999
  • The stability and efficiency of structural control systems depend on the accuracy of mathematical model of the system to be controlled. In this study, state equation models of a small scale test structure and an AMD(active mass damper) are obtained separately using OKID(observer/Kalman filter identification) which is a time domain system identification method. The test structure with each floor acceleration as outputs is identified for two inputs - the ground acceleration and the acceleration of the moving mass of AMD relative to the installation floor - individually and the two identified state equation models are integrated into one by model reduction method. The AMD is identified with the motor control signal as an input and the relative acceleration of the moving mass as an output, and it is shown that the identified model has large damping ratio and phase shift. The transfer functions and the time histories reconstructed from the identified models of the test model and the AMD match well with those measured from the experiment.

  • PDF

Development of Power Plant Simulator for Control System Verification & Validation (제어 검증용 발전소 시뮬레이터 개발)

  • Byun, Seung-Hyun;Hwang, Do-Hyun
    • Journal of the Korea Society for Simulation
    • /
    • v.19 no.1
    • /
    • pp.41-51
    • /
    • 2010
  • A control system has been being developed by korean engineers for 500MW korean standard type fossil power plant with the advent of retrofit of old control system. Simulators have been used for digital I&C system pre-tests and validation tests in nuclear power plants. In this paper, the power plant simulator for control system V&V was developed in order to verify the developed control system prior to application to a power plant. The control models were developed using plant control system data, translator programs, and vendor manuals. The developed simulator was verified by steady-state test, load swing test, transient test and so on.

Vibration Control for Building Structures usign Active Mass Driver(I) : System Design (능동 제어장치를 이용한 건물의 진동제어 (I): 시스템 설계)

  • 민경원;김두훈;이성경;황재승
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.4
    • /
    • pp.87-94
    • /
    • 1998
  • Increasing flexibility and lightness of recently built high-rise buildings make the structures susceptible to loads such as earthquakes and winds. Therefore, higher performance vibration control systems to reduce the vibration levels are demanded more than any time in the past. One of the typical active vibration control systems is the active mass driver (AMD). In this paper, an active vibration control system consisting of small shaking table, building model, sensors, signal processing board and AMD is constructed. The dynamic characteristics of these individual systems are investigated through the experimental study. The performance of the active vibration control system is verified through the El Centro earthquake(1940,NS) on the building model.

  • PDF

Observer Kalman Filter Identification of a Three-story Structure installed with Active Mass Driver (OKID를 이용한 실험 건물모델의 시스템 식별 실험)

  • 주석준;이상현;민경원
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.17 no.2
    • /
    • pp.161-169
    • /
    • 2004
  • This paper deals with system identification of a three-story building model with active mass damper (MID) for the controller design. Observer Kalman filter identification (OKID) technique is applied to find the relationship between the experimental results of the input and output. The inputs to the building model with MID are ground accelerations and motor command signal, which are, respectively, simulated earthquake and equivalent control force. The outputs are each floor acceleration and MID acceleration. The MID controller is designed based on the experimentally identified building system. Finally it is shown that experimental results agree accurately with simulated results.

Robust Stability Analysis and Design of Fuzzy Model Based Feedback Linearization Control Systems (퍼지 모델 기반 피드백 선형화 제어 시스템의 강인 안정성 해석과 설계)

  • 박창우;이종배;김영욱;성하경
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.41 no.3
    • /
    • pp.79-90
    • /
    • 2004
  • Systematical robust stability analysis and design scheme for the feedback linearization control systems via fuzzy modeling are proposed. It is considered that uncertainty and disturbances are included in the Takagi-Sugeno fuzzy models representing the nonlinear plants. Robust stability of the closed system is analyzed by casting the systems into the diagonal norm bounded linear differential inclusions and by converting the analysis and design problems into the linear matrix inequality optimization, a numerical method for finding the maximum stable ranges of the fuzzy feedback linearization control gains is also proposed. To verify the effectiveness of the proposed scheme, the robust stability analysis and control design examples are given.

Modeling of SVPWM and Control Method for Driving Systems of High-speed Trains by using Multi-level Power Converters (고속전철 추진시스템을 위한 멀티레벨 전력변환기의 제어기법 및 SVPWM 모델링)

  • Lee, Dong-Myung;Hong, Chan-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.136-145
    • /
    • 2009
  • This paper proposes control methods and simulation models of a driving system, which consists of converters and inverters, for high speed trains employing multi-level power converters. The control method of a single phase three-level converter for high-speed trains is designed to use DC values instead of instantaneous current values which are usually used in single-phase application, so that it results in a fast and robust voltage control response. In addition, simulation models of Space Vector Pulse Width Modulation (SVPWM) for single phase three-level converters as well as three level inverters are proposed. Experimental results demonstrate the validity of the simulation model for three-level inverters.

A Study on the Tension Control for Catenary′s cable (현수형 가선케이블의 일정 장력유지 제어에 관한 연구)

  • Hong S. I;Yoon J. H
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.1 no.2
    • /
    • pp.153-159
    • /
    • 2000
  • The cable installed will have catenary's type that is nonlinear and variable time system. Because it has a close relation to the catenary's type to determine command value of tension for the tension control of this cable, we need to study it. The purpose of this study is automated the installation equipment (or a catenary's cable. This study shows control system that the tension of a catenary's cable is keep constant. 'rho control method is adopted the fuzzy control that is robust because the model of a control object is nonlinear and variable time system and feed-forward control to suppress overshoot as a shift begins to move. On the basis of the dynamic modeling of a catenary's cable we compose the control system with adopting fuzzy and feed-forward control has recognized the effectiveness in simulation results.

  • PDF