• Title/Summary/Keyword: 면적 비저항

Search Result 222, Processing Time 0.029 seconds

Gene Manipulation of Pin 2(Proteinase Inhibitor II) to the Cottonwood Leaf Beetle(Coleoptera : Chrysomelidae) in Transgenic Poplar(Populus deltodies × P. nigra) (형질전환(形質轉換)된 포플러의 딱정벌레에 대한 저항성(抵抗性) 유전자(遺傳子)(Proteinase Inhibitor II) 발현(發現))

  • Kang, Hoduck
    • Journal of Korean Society of Forest Science
    • /
    • v.86 no.4
    • /
    • pp.407-414
    • /
    • 1997
  • The resistance of a non-transgenic poplar clone, 'Ogy' and three transgenic poplar lines to the cottonwood leaf beetle, Chrysomela scripta F., was evaluated by in vitro feeding. The lines were transformed with neomycin phosphotransferase II(NPT II) as a selectable marker, proteinase inhibitor II(pin2) as a resistance gene, and CaMV 35S as a promoter. An efficient method of sterilizing the beetle eggs and introducing them into plant tissue cultures was developed. The resistance of the transgenic lines was investigated in terms of effects tin leaf area consumed, insect weight, insect developmental stages, and plantlet root dry weight after feeding. Also, leaf area consumed was examined by leaf age as measured through leaf plastochron index(LPI). The leaf area consumed and insect weight were highly significant between transformants and control, and insect development in vitro was significant among the transgenic lines. Larval infestation was the most severe around LPI 4 to 5 which were young leaves. The system provided a quick, highly controlled method to screen developing transgenic plantlets directly.

  • PDF

Cathode side protection coating for Planar-type SOFC interconnect (평판형 SOFC 분리판 보호코팅 개발)

  • Lee, Jaemyung;Jun, Jaeho;Sung, ByungGeun;Kim, Dohyung;Jun, Junghwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.83.2-83.2
    • /
    • 2010
  • 평판형 고체산화물 연료전지(planar SOFC : Solid oxide Fuelcell)는 높은 전류 효율 및 출력밀도를 가지는 중,대형 발전용 전기소자이다. SOFC 스택을 600~800도에서 작동할 경우, 금속 분리판에서 휘발된 크롬에 의한 열화현상과 금속의 산화에 의한 표면 저항의 증가가 큰 문제점으로 알려져 있으며, 이를 개선하기 위한 많은 연구가 진행되고 있다. 본 연구에서는 금속 분리판의 열화를 억제하기 위한 여러 보호코팅의 특성을 밝히고, 특성차이의 원인을 분석하고자 하였다. 모재는 상용 STS444합금 (Nisshin steel 생산) 2.0mmt 박판을 사용하였으며, 표면 상태를 균일하게 하기 위하여 표면은 동일한 #1200 번 사포로 연마후 코팅하였다. 적용한 코팅은 전기도금 Ni 코팅, (MnCo)3O4 wet powder spray 코팅, (MnCo)3O4 ADM코팅 3종이었으며, 코팅층의 두께는 최적 공정조건에 따라 달리 하였다. 산화후 형성되는 표면 산화물의 전기적 특성을 평가하기 위하여 시험편의 비면적 저항 (ASR : area specific resistance)을 장시간 측정하였다. 측정편의 크기는 가로 4cm ${\times}$ 세로 4cm였으며, 100시간 공기중 산화후 측정하였다. 표면 접촉을 높이기 위하여 Pt paste를 40~50um도포하였으며, 1~0.1A인가된 전류에 대한 저항을 4전극법 (4-probe)으로 측정하였다. 표면 코팅층이 크롬 휘발을 억제하는 정도를 평가하기 위하여 크롬 휘발량을 측정하였다. 시편은 가로 1.5cm ${\times}$ 세로 1cm 였으며, 공급된 공기와 수분의 혼합가스와 응축기 표면에 흡착된 크롬의 양을 ICP-MASS법으로 측정하였다.

  • PDF

A Study on the Improvement of Fore-Body Shape Considering Breaking Wave Phenomena (쇄파현상을 고려한 선수형상개량법에 관한 연구)

  • K.J.,Kang;E.C.,Kim
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.26 no.2
    • /
    • pp.1-12
    • /
    • 1989
  • This paper presents a method of minimizing the wave resistance components, due to the linear wave propagating to the far field and the breaking wave in the vicinity of the hull. This method consists of the linear optimization method for the linear wave resistance and the statistical optimization method for the breaking wave resistance through the analysis of the experimental data. For the purpose of the application, a wall-sided model with parabolic waterplane shape was selected as a basic hull form, and two modified hull forms with varied $C_p-curve$ of the fore-body were derived from the linear wave optimization method and the empirical method. The correlation between the linear wave resistance and the breaking wave resistance according to the $C_p-curve$ variation of the fore-body was investigated through the experimental and analytical results for the three hull forms. The fore-body shape optimized by the present method shows the reduction of the wave resistance by 47% comparing to the basic hull form at the design speed($F_n=0.26$).

  • PDF

Pullout Test Results of Geosynthetics using Granite Soil and Standard sand (화강토와 표준사를 이용한 토목섬유의 인발시험결과 비교)

  • Ju, Jae-Woo;Park, Jong-Beom;Kim, Jang-Heung;Song, Chun Seok;Baek, Kyung-Jong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.4 no.2
    • /
    • pp.39-45
    • /
    • 2005
  • New concept called the pullout resistance angle has been used to express the friction, cohesion and passive resistance by pullout test at geosynthetics reinforced soil. And also in order to calculate the pullout area, the distribution area method has been used, which is a method of using the curve of tensile force exerted in geogrid. The distribution area ratio showed nearly the same result in the two kind of soils, the granite soil and the standard soil. The pullout resistance angle showed the greater value than friction angle of soil in case of low confining stress of $0.2kg/cm^2$, while it showed the smaller angle than friction of soil in case of high confining stress of $0.8kg/cm^2$.

  • PDF

Detection of Sea-water Intrusion Caused by Tidal Action Using DC Resistivity Monitoring (전기비저항 모니터링을 이용한 해수침투 파악)

  • Hwang, Hak-Soo;Lee, Sang-Kyu;Ko, Dong-Chan;Kim, Yang-Soo;Park, In-Hwa
    • Geophysics and Geophysical Exploration
    • /
    • v.3 no.1
    • /
    • pp.1-6
    • /
    • 2000
  • The 1 $km^2$ area studied is located in Sukchun-ri, Hwasung-koon, the southern part of Kyeonggi-do. Even though this site has been known as a contaminated area caused by seawater intrusions, geophysical and geochemical surveys have never been carried out at the site to determine the extent of the seawater contamination and to investigate whether the seawater intrusion is in progress. The purpose of this study is to determine the extent of seawater contamination and a preferred channel of the seawater intrusion using geophysical methods such as DC resistivity surveys with Schlumberger array and a dipole-dipole array. In order to determine whether the seawater intrusion is in progress in the area, DC resistivity monitoring with Schlumberger array was performed. According to the resistivity map obtained from the inversion of the resistivity data measured with Schlumberger array, the study area is divided into two districts as relatively lowly resistive (less than 30 ohm-m) and highly resistive (more than 30 ohm-m) areas. The distribution of the lowly resistive area is consistent with the distribution of the layer composed of clay minerals, and the resistivity of this layer decreases slowly as approaching to the old seashore. Hydrogeological analysis shows that the clay layer within a distance of about 200 m from the seashore has been already contaminated by sea-water and its electric conductivity is 8 times higher than that of the sand layer covered by the clay layer. According to the results of the 2-dimensional DC resistivity surveys with a dipole-dipole array, there are two preferred channels of the seawater intrusion in the site, and both the channels are in the NW-SE direction from the old seashore. The lowly resistive zone in the southern channel extends to a depth of 80 m. The DC resistivity monitoring with Schlumberger array was carried out along the preferred channel which has the low resistivity Bone (fracture zone) that extended to a depth of 80 m. The time series of apparent resistivity, measured at a distance of 260 m from the old coast line, fluctuates with a period of 12 hours. From these observations, it can be concluded that the seawater intrusion caused by tidal action is still in progress along the fractured zone interpreted by the DC resistivity surveys with a dipole-dipole array.

  • PDF

Flow Resistance of Plane Nettings for Net Cages (우리 그물용 평면 그물감의 유수저항)

  • KIM Tae-Ho;KIM Dae-An;RYU Cheong-Ro
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.34 no.3
    • /
    • pp.254-259
    • /
    • 2001
  • In order to make clear the resistance of plane nettings u,sed widely in constructing net cages, the resistance R taken by $R=kSU^2$, where S was the wall area of nettings, U the flow velocity, and k the resistance coefficient, was measured in a circulating water channel by using nylon Raschel nettings and PE trawler-knotted nettings coated with anti-fouling paint or not and then the properties of coefficient k were investigated. The mesh size L and the angle $\phi$ between two adjacent bars was given by the function of Reynolds number ${\lambda}U/v$ in the region of ${\lambda}U/v<180$, i. e., $$k=350(\frac{\lambda U}{v})^{-0.25}$$.where $\lambda$ was the representative size of nettings expressed as $$\lambda=\frac{{\pi}d^2}{2L\;sin\;2{\phi}}$$On the other hand, the coefficient k was almost fixed between 92 and 102 ($kg{\cdot}s^2/m^4$) in the region of ${\lambda}U/v{\geq}180$ and varied according to the ratio $S_n/S$ of the total area $S_n$ of nettings projected to the plane perpendicular to the water flow to the wall area S of nettings, i.e., it was given by $$k=98.6(\frac{S_n}{S})^{1.19}$$ regardless of the coating of paint.

  • PDF

Magnetic exchange coupled NiFe/TbCo thin films for thin film magnetoresistive heads (박막 자기 저항 헤드용 자기교환 결합 NiFe/TbCo박막)

  • 오장근;조순철;안동훈
    • Journal of the Korean Magnetics Society
    • /
    • v.3 no.4
    • /
    • pp.293-297
    • /
    • 1993
  • Exchange coupled $NiFe/TbCo/Sio_{2}$ thin films for magnetoresistive heads were sputter deposited using RF diode sputtering method, and their magnetic characteristics were measured. TbCo films were deposited using a composite target, which is composed of Tb chips epoxied on a Co target. NiFe($400\AA$)/TbCo($1500\AA$)/$SiO_{2}$($500\AA$) films were deposited using a TbCo target having 30 % of Tb area ratio, which showed 25 Oe of the exchange field without substrate bias and 12 Oe with -55 V of substrate bias. The effective in-plane coercivities of the three layer films fabricated with less than -55 V of substrate bias were approximately proportional to the perpendicular coercivities of the TbCo layer only. The films fabricated with a Theo target of 28 % area ratio showed the same trend. However, the exchange field decreased to 4 Oe without the substrate bias and 7 Oe with -55 V of substrate bias. In the films fabricated with 1000 W of power and the target of 36 % area ratio exhibited 100 Oe of exchange field and 3 Oe of coercivity. As the thickness of NiFe layer increased, the exchange field decreased.

  • PDF

Performance degradation of SOFC caused by increase of polarization resistance for the cathode during long-term test (공기극 분극 저항 증가에 따른 SOFC 단전지 성능 감소에 관한 연구)

  • Park, Kwang-Jin;Bae, Joong-Myeon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.349-352
    • /
    • 2009
  • In this study, the relation between the performance degradation of SOFC single cell and the increase of polarization resistance for the cathode is investigated. $Pr_{0.3}Sr_{0.7}Co_{0.3}Fe_{0.7}O_3$(PSCF3737, $19.4{\times}10^{-6}K^{-1}$) and $Gd_{0.1}Ce_{0.9}O_2$ (CGO91, $12{\times}10^{-6}K^{-1}$) are used as a cathode and an electrolyte, respectively. The polarization resistance of cathode is increased due to the delamination caused by thermal expansion coefficient difference. The voltage drop with 10%/1000h decline rate occurs during long-term, when the interface between the cathode and the electrolyte is delaminated due to TEC difference.

  • PDF

An effect of the shape of cutting blade on cutting resistance of rice stalk (콤바인 예취날의 형상이 볏짚절단저항에 미치는 영향)

  • Choi, Woo-Young;Kim, Tae-Han
    • Current Research on Agriculture and Life Sciences
    • /
    • v.22
    • /
    • pp.41-48
    • /
    • 2004
  • This study is performed in order to provide the basic information needed for the development of cutting blade for combine. By comparing the developed cutting blade of which were made groove of the surface with the common cutting blade. Friction force and cutting resistance by the cutter bar speed ratio and moisture content of rice stalk were shown as follows: 1. The friction force of the developed cutting blade is shown at the average value $0.12kg{\cdot}m$ as 25% lower than one of the common blade at the average value $0.16kg{\cdot}m$. 2. The cutting resistance of the developed cutting blade is shown as respectively 12%, 15% and 20% lower than one of the common blade at the moisture content of rice stalk of 14.2%, 55.3% and 84.2%. 3. The cutting resistance of cutting blade by two different driving types is shown that the one by double driving type is $0.2kg{\cdot}m$, and the one by single driving type is $0.24kg{\cdot}m$. 4. Optimum cutter bar speed ratio of cutting blade is shown as different according to the moisture content of rice stalk.

  • PDF

A Study on The Corrosion Resistance of Concrete Containing Copper Slag (동제련 슬래그 혼입 콘크리트의 부식 저항성에 관한 연구)

  • Lee, Dong-Un;Jung, Yoo-Jin;Kim, Young-Su
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.5
    • /
    • pp.189-196
    • /
    • 2007
  • The purpose of this study was to analyze steel corrosion resistance of concrete containing copper slag. The specimens were made with normal portland cement and pozzolan materials with various replacement ratio and with W/B ratio ranging from 35% to 55%. Compressive strength, coefficient of chloride diffusion, corrosion area ratio and weight reduction ratio were determinated for the test. The results show that the concrete with pozzolan materials is superior resistant to chloride ions compared to the concrete without pozzolan materials. It was observed that blast furnace slag replacement ratio of 20% gives the best results with respect to chloride ion penetration and corrosion tests and observed that copper slag replacement ratio of 10% gives the seperior resistance compared to normal concrete.